Tiêu đề Optical multiservice edge 6500 fault management customer visible logs
Trường học Nortel Networks
Chuyên ngành Fault Management
Thể loại Báo cáo
Năm xuất bản 2009
Thành phố Canada
Định dạng
Số trang 182
Dung lượng 1,99 MB

Các công cụ chuyển đổi và chỉnh sửa cho tài liệu này

Nội dung

thiết bị ome

Trang 1

Fault Management-

Customer Visible Logs

Standard Release 6.0 Issue 1 September 2009

What’s inside

Introduction to customer visible logs

Domain Optical Controller (DOC) logs

Trang 2

Networks, the holder is granted no rights to use the information contained herein and this document shall not be published, copied, produced or reproduced, modified, translated, compiled, distributed, displayed or transmitted, in whole or part, in any form or media.

This information is provided “as is”, and Nortel Networks does not make or provide any warranty of any kind, expressed or implied, including any implied warranties of merchantability, non-infringement of third party intellectual property rights, and fitness for a

Trang 3

Optical Multiservice Edge 6500 Fault Management - Customer Visible Logs

Release 6.0 Sep 2009

Copyright  2004-2009, Nortel Networks

Trang 5

Optical Multiservice Edge 6500 Fault Management - Customer Visible Logs

Release 6.0 Sep 2009

Copyright  2004-2009, Nortel Networks

The following sections detail what’s new in Fault Management - Customer Visible Logs, 323-1851-840 Standard Issue 1 for Release 6.0

New features

No new logs have been added in this issue

Trang 7

Optical Multiservice Edge 6500 Fault Management - Customer Visible Logs

Release 6.0 Sep 2009

Copyright  2004-2009, Nortel Networks

1-This section provides an introduction to the use of customer visible logs in troubleshooting failures related to the Domain Optical Controller

Trang 8

alarms to signal fault conditions These alarms include:

Faults that result in one of these alarms prevent DOC from continuing a re-optimization as this could result in worse performance conditions for surviving traffic

DOC maintains logs detailing any failure of previously executed commands that can result in the above listed alarms The DOC Customer Visible Logs are retrievable from the Site Manager DOC application and the “Logs” button.The DOC logs are used to determine the fault responsible for the DOC alarm

on the network element The procedures contained in this guide outline the steps required to clear the faults based on the content of the logs Once the fault is cleared DOC can re-attempt the channel action

DOC Log Description

The DOC logs are displayed by opening the Configuration -> Photonic Services -> Domain Optical Controller (DOC) tab in Site Manager for a network element containing a DOC site Once a DOC instance is selected the user can Click the "Logs" button to view the CVLs

In the case of any DOC Failure the DOC Logs should be retrieved and saved for investigation before any troubleshooting steps are taken DOC logs are updated when a DOC action failure occurs The logs remain until either the next failure or when the "Clear DOC Logs" button is selected in Site Manager.DOC Logs report details for 5 sections:

Trang 9

Optical Multiservice Edge 6500 Fault Management - Customer Visible Logs

Release 6.0 Sep 2009

Copyright  2004-2009, Nortel Networks

The topology logs outline the system and channel topologies for the DOC, Network and Section The Command logs outline the steps taken, and the faults detected, that resulted in the alarm being raised

For details on Domain and Sections see the Photonic services - Photonic advanced optical control section of the OME 6500 Planning Guide (Part 2 of 3)

DOC Log Format

An example of the DOC Log window is shown below The format of the DOC logs are also described in this section

***************************************************************************************

***************************************************************************************

Trang 10

Logs for <TID-SHELF>

***************************************************************************************

* Domain Optical Control Topology Log

*

***************************************************************************************DOC topology at <YYYY-MM-DD> <hh:mm:ss>

DOC Site <TID>-<SHELF>

Configuration: <Configuration>

List of SOC SitesTID-Shelf

========

<TID>-<SHELF>-<PATH ID> (repeated for all SOC Sites)

Network Channel AID Optimization State SHELF (Add & Drop)NC-<SHELF>-<SITEID>-<Remote Shelf>-<Remote Path>-<Wavelength>

<Optimization State of Channel> <TID of Add Shelf>-<SHELF>-<PATH ID>

<TID of Drop Shelf>-<SHELF>-<PATH ID> (repeated for all defined channels)

***************************************************************************************

* Domain Optical Control Command Log

*

***************************************************************************************

Trang 11

Optical Multiservice Edge 6500 Fault Management - Customer Visible Logs

<YYYY-MM-DD> <hh:mm:ss> Section Topology log (repeated for all logs)

DOC Log Troubleshooting Documents

The procedures contained in this guide contain details on how to troubleshoot failures based on the contents of the DOC Logs The procedures are presented in the following format:

Log text - The text presented to the user in the DOC LogDescription/Probable cause - Outlines the cause of the faultTroubleshooting information - Details on resolving the fault

Trang 12

describing directions in the photonic network:

Upstream: Components that exists prior to the current point in the optical traffic path

Downstream: Components that exists after the current point in the optical traffic path

Example

TX -CMD44(1) WSS(1) -MLA(1) MLA(2) -WSS(2) CMD44(2) RXThe TX is upstream of CMD44(1)

CMD44(2) is downstream of WSS(2)

Trang 13

Optical Multiservice Edge 6500 Fault Management - Customer Visible Logs

Release 6.0 Sep 2009

Copyright  2004-2009, Nortel Networks

2-This section provides detailed information on DOC logs That information is to

be used for troubleshooting purposes

Trang 14

Topology Routing Failure - Routing message failed to sent to:

<TID>-<SHELF>, rem_path <PATH>

A failure occurred while trying to send Routing message to the next node with

<TID>-<SHELF> and rem_path <PATH> The probable cause is a communication error between network elements in the section

A retry mechanism will ensure that routing message is eventually sent once the error condition is resolved

Troubleshooting information

available, a condition might exists on the network which is preventing normal communication between network elements This should be addressed using network troubleshooting techniques

clearing procedures

any NE is running an older release, proceed with the appropriate upgrade procedure to upgrade all NEs to the same software release

nodes in the network

Visualization tool (Network View) If the Visualization tool is not available issue the command RTRV-TOPO-OST and verify that all nodes in the network are listed as expected

—end—

Trang 15

Optical Multiservice Edge 6500 Fault Management - Customer Visible Logs

Release 6.0 Sep 2009

Copyright  2004-2009, Nortel Networks

Update remote section routing request to <TID>-<SHELF> timed out, rem_path <PATH>

If that is the case then the probable cause is a communication error between network elements in the section

A retry mechanism will ensure that routing message is eventually sent once the error condition is resolved

Troubleshooting information

available, a condition might exists on the network which is preventing normal communication between network elements This should be addressed using network troubleshooting techniques

clearing procedures

any NE is running an older release, proceed with the appropriate upgrade procedure to upgrade all NEs to the same software release

nodes in the network

Visualization tool (Network View) If the Visualization tool is not available issue the command RTRV-TOPO-OST and verify that all nodes in the network are listed as expected

—end—

Additional information

CVL 65549, 65581 might be seen after this one is generated

Trang 16

"Network Topology Build Failure - ""DOC incorrectly provisioned - Consult

Description/Probable cause

The provisioning data for the Optical Domain is incorrect The following rules must be observed when provisioning an Optical Domain:

for linear systems

network path is valid when the OTSs’ Tx path values in a direction have the same parity, i.e all odd or all even values

Troubleshooting information

Site Manager

• Click on "Overlays " and select the "DOC indicator" and the "OSID indicator" options Click Ok

if it is a linear configuration

Trang 17

Optical Multiservice Edge 6500 Fault Management - Customer Visible Logs

Release 6.0 Sep 2009

Copyright  2004-2009, Nortel Networks

Topology" tab in the Visualization application

an OTS instance" procedure to change the "DOC Indicator" parameter value in the OTS

re-provisioned with the correct value

TL1

OTS parameters:

RTRV-OTS::OTS-<SHELF>-<INSTANCE>:CTAG;

value in the OTS:

ED-OTS::OTS-<SHELF>-<INSTANCE>:CTAG:::DOCIND=<docind>;

<docind>: Y to set as a DOC instance, N to not site as a DOC instance

delete the OTS and re-provision it with the correct Tx path value

—end—

Additional information

None

Trang 18

Network Topology Build Failure - Refer to Section Logs at <TID>-<SHELF>.

communication issue or a provisioning error

Troubleshooting information

Site Manager

Login to the node hosting the DOC for which this log was generated

Launch the Configuration -> Domain Optical Controller (DOC) application, and select the DOC instance from the list that is managing the optical section starting at TID-SHELF

Click on the "DOC Logs" button In the DOC Logs window, scroll domain to the

"Section Topology Logs" section and examine the detailed logs for the section TID-SHELF

Refer to the troubleshooting section of the detailed logs for more information

on how to resolve the problem

TL1

Login to the node hosting the DOC for which this log was generated

Use the RTRV-DOC-LOG command to retrieve the DOC logs and examine the detailed logs for the section TID-SHELF

Refer to the troubleshooting section of the detailed logs for more information

on how to resolve the problem

Trang 19

Optical Multiservice Edge 6500 Fault Management - Customer Visible Logs

Release 6.0 Sep 2009

Copyright  2004-2009, Nortel Networks

Network Topology Build Failure - Number of sections in network exceeds the

<Maximum number of sections allowed in a network> allowed

Troubleshooting information

exceed the maximum limit

—end—

Additional information

None

Trang 20

Network Topology Build Failure

A failure occurred while trying to build the network topology

A retry mechanism will ensure that the channel topology is eventually discovered once the error condition is resolved

Troubleshooting information

available, a condition might exists on the network which is preventing normal communication between network elements This should be addressed using network troubleshooting techniques

clearing procedures

any NE is running an older release, proceed with the appropriate upgrade procedure to upgrade all NEs to the same software release

nodes in the network

Visualization tool (Network View) If the Visualization tool is not available issue the command RTRV-TOPO-OST and verify that all nodes in the network are listed as expected

—end—

Additional information

Trang 21

Optical Multiservice Edge 6500 Fault Management - Customer Visible Logs

Release 6.0 Sep 2009

Copyright  2004-2009, Nortel Networks

Network Topology Build Failure - Timeout of RoutingSet due to Invalid Path - OP_NECHT

Description/Probable cause

The topology application failed to set the routing information on one or more nodes in the optical domain This log can be generated when there is a problem with inter-node communication or when the domain is not provisioned incorrectly

Troubleshooting information

Site Manager

might exist on the network which is preventing normal communication between network elements This should be addressed using network troubleshooting techniques

are alarms that indicate a communication failure, such as "OSC Loss of Signal" or "Adjacency Far End Not Discovered" Refer to the alarm troubleshooting section for details on clearing any alarm present

release which is running all nodes in the network If any node is running

an older release, proceed with the appropriate upgrade procedure to ensure all nodes are running the same release

equipment and facilities are present and in-service for all nodes in the network

more than two DOC sites present in each domain

Trang 22

are alarms that indicate a communication failure, such as "OSC Loss of Signal" or "Adjacency Far End Not Discovered" Refer to the alarm troubleshooting section for details on clearing any alarm present

is running all nodes in the network If any node is running an older release, proceed with the appropriate upgrade procedure to ensure all nodes are running the same release

equipment and facilities are present and in-service for all nodes in the domain

domain are listed as expected

DOC sites present in each domain

Additional information

None

Trang 23

Optical Multiservice Edge 6500 Fault Management - Customer Visible Logs

Release 6.0 Sep 2009

Copyright  2004-2009, Nortel Networks

Network Topology Build Failure - Timeout of RoutingSet due to Invalid Path - OP_OSCT

Description/Probable cause

The topology application failed to set the routing information on one or more nodes in the optical domain This log can be generated when:

Troubleshooting information

Site Manager

might exist on the network which is preventing normal communication between network elements This should be addressed using network troubleshooting techniques

are alarms that indicate a communication failure, such as "OSC Loss of Signal" or "Adjacency Far End Not Discovered" Refer to the alarm troubleshooting section for details on clearing any alarm present

release which is running all nodes in the network If any node is running

an older release, proceed with the appropriate upgrade procedure to ensure all nodes are running the same release

Trang 24

more than two DOC sites present in each domain

displayed as expected

TL1

are alarms that indicate a communication failure, such as "OSC Loss of Signal" or "Adjacency Far End Not Discovered" Refer to the alarm troubleshooting section for details on clearing any alarm present

is running all nodes in the network If any node is running an older release, proceed with the appropriate upgrade procedure to ensure all nodes are running the same release

equipment and facilities are present and in-service for all nodes in the domain

domain are listed as expected

DOC sites present in each domain

Additional information

None

Trang 25

Optical Multiservice Edge 6500 Fault Management - Customer Visible Logs

Release 6.0 Sep 2009

Copyright  2004-2009, Nortel Networks

Network Topology Build Failure - Local section data is invalid or unavailable

available, a condition might exists on the network which is preventing normal communication between network elements This should be addressed using network troubleshooting techniques

clearing procedures

any NE is running an older release, proceed with the appropriate upgrade procedure to upgrade all NEs to the same software release

nodes in the network

Visualization tool (Network View) If the Visualization tool is not available issue the command RTRV-TOPO-OST and verify that all nodes in the network are listed as expected

—end—

Additional information

CVL 65541 might be seen along with this one

Trang 26

Network Topology Build Failure - Network Path could not be resolved by NCT

at <TID>-<SHELF> rem_path <PATH> Consult logs and Network Viewer

A retry mechanism will ensure that the channel topology is eventually discovered once the error condition is resolved

Troubleshooting information

available, a condition might exists on the network which is preventing normal communication between network elements This should be addressed using network troubleshooting techniques

clearing procedures

any NE is running an older release, proceed with the appropriate upgrade procedure to upgrade all NEs to the same software release

nodes in the network

Visualization tool (Network View) If the Visualization tool is not available issue the command RTRV-TOPO-OST and verify that all nodes in the network are listed as expected

—end—

Trang 27

Optical Multiservice Edge 6500 Fault Management - Customer Visible Logs

Release 6.0 Sep 2009

Copyright  2004-2009, Nortel Networks

Network Topology Build Failure - Network Path could not be resolved by NCT

at <TID>-<SHELF> Consult logs and Network Viewer

A retry mechanism will ensure that the channel topology is eventually discovered once the error condition is resolved

Troubleshooting information

available, a condition might exists on the network which is preventing normal communication between network elements This should be addressed using network troubleshooting techniques

clearing procedures

any NE is running an older release, proceed with the appropriate upgrade procedure to upgrade all NEs to the same software release

nodes in the network

Visualization tool (Network View) If the Visualization tool is not available issue the command RTRV-TOPO-OST and verify that all nodes in the network are listed as expected

—end—

Additional information

CVL 65540 might be seen before this one is generated

Trang 28

Sectional Topology Build Failure - Local shelf wavelength data is invalid or unavailable at <TID>-<SHELF>

available, a condition might exists on the network which is preventing normal communication between network elements This should be addressed using network troubleshooting techniques

clearing procedures

any NE is running an older release, proceed with the appropriate upgrade procedure to upgrade all NEs to the same software release

nodes in the network

Visualization tool (Network View) If the Visualization tool is not available issue the command RTRV-TOPO-OST and verify that all nodes in the network are listed as expected

—end—

Trang 29

Optical Multiservice Edge 6500 Fault Management - Customer Visible Logs

Release 6.0 Sep 2009

Copyright  2004-2009, Nortel Networks

Sectional Topology Build Failure - Number of shelves in section starting with

<TID>-<SHELF> exceeds <Maximum number of shelves allowed in a section>

Troubleshooting information

number of shelves in it does not exceed the maximum limit

—end—

Additional information

None

Trang 30

Sectional Topology Build Failure - Sectional Path could not be resolved by OSCT at <TID>-<SHELF> rem_path <PATH> Consult section logs.

A retry mechanism will ensure that the channel topology is eventually discovered once the error condition is resolved

Troubleshooting information

available, a condition might exist on the network which is preventing normal communication between network elements This should be addressed using network troubleshooting techniques

clearing procedures

any NE is running an older release, proceed with the appropriate upgrade procedure to upgrade all NEs to the same software release

nodes in the network

Visualization tool (Network View) If the Visualization tool is not available issue the command RTRV-TOPO-OST and verify that all nodes in the network are listed as expected

Trang 31

Optical Multiservice Edge 6500 Fault Management - Customer Visible Logs

Release 6.0 Sep 2009

Copyright  2004-2009, Nortel Networks

Sectional Topology Build Failure - Sectional Path could not be resolved by OSCT at <TID>-<SHELF> Consult section logs

A retry mechanism will ensure that the channel topology is eventually discovered once the error condition is resolved

Troubleshooting information

available, a condition might exist on the network which is preventing normal communication between network elements This should be addressed using network troubleshooting techniques

clearing procedures

any NE is running an older release, proceed with the appropriate upgrade procedure to upgrade all NEs to the same software release

nodes in the network

Visualization tool (Network View) If the Visualization tool is not available issue the command RTRV-TOPO-OST and verify that all nodes in the network are listed as expected

—end—

Additional information

None

Trang 32

Topology Build Failure - Comms failure receiving from <TID>-<SHELF> rem_path <PATH>.

communication problem between network elements in the section

A retry mechanism will ensure that the channel topology is eventually discovered once the error condition is resolved

Troubleshooting information

available, a condition might exist on the network which is preventing normal communication between network elements This should be addressed using network troubleshooting techniques

clearing procedures

any NE is running an older release, proceed with the appropriate upgrade procedure to upgrade all NEs to the same software release

nodes in the network

Visualization tool (Network View) If the Visualization tool is not available issue the command RTRV-TOPO-OST and verify that all nodes in the network are listed as expected

Trang 33

Optical Multiservice Edge 6500 Fault Management - Customer Visible Logs

Release 6.0 Sep 2009

Copyright  2004-2009, Nortel Networks

Topology Build Failure - Comms failure receiving from <TID>-<SHELF>, rem_path <PATH>

communication problem between network elements in the section

A retry mechanism will ensure that the channel topology is eventually discovered once the error condition is resolved

Troubleshooting information

available, a condition might exist on the network which is preventing normal communication between network elements This should be addressed using network troubleshooting techniques

clearing procedures

any NE is running an older release, proceed with the appropriate upgrade procedure to upgrade all NEs to the same software release

nodes in the network

Visualization tool (Network View) If the Visualization tool is not available issue the command RTRV-TOPO-OST and verify that all nodes in the network are listed as expected

—end—

Additional information

None

Trang 34

Topology Build Failure - Failed to open TCP connection with <TID>-<SHELF> send_path <PATH>.

A retry mechanism will ensure that the channel topology is eventually discovered once the error condition is resolved

Troubleshooting information

available, a condition might exist on the network which is preventing normal communication between network elements This should be addressed using network troubleshooting techniques

clearing procedures

any NE is running an older release, proceed with the appropriate upgrade procedure to upgrade all NEs to the same software release

nodes in the network

Visualization tool (Network View) If the Visualization tool is not available issue the command RTRV-TOPO-OST and verify that all nodes in the network are listed as expected

Trang 35

Optical Multiservice Edge 6500 Fault Management - Customer Visible Logs

Release 6.0 Sep 2009

Copyright  2004-2009, Nortel Networks

Topology Build Failure - Failed to receive TCP data response from

<TID>-<SHELF>, rem_path <PATH>

A retry mechanism will ensure that the channel topology is eventually discovered once the error condition is resolved

Troubleshooting information

available, a condition might exist on the network which is preventing normal communication between network elements This should be addressed using network troubleshooting techniques

clearing procedures

any NE is running an older release, proceed with the appropriate upgrade procedure to upgrade all NEs to the same software release

nodes in the network

Visualization tool (Network View) If the Visualization tool is not available issue the command RTRV-TOPO-OST and verify that all nodes in the network are listed as expected

—end—

Additional information

None

Trang 36

Topology Build Failure - Failed to send TCP data request from

<TID1>-<SHELF1> to <TID2>-<SHELF2>, rem_path <PATH>

A retry mechanism will ensure that the channel topology is eventually discovered once the error condition is resolved

Troubleshooting information

available, a condition might exist on the network which is preventing normal communication between network elements This should be addressed using network troubleshooting techniques

clearing procedures

any NE is running an older release, proceed with the appropriate upgrade procedure to upgrade all NEs to the same software release

nodes in the network

Visualization tool (Network View) If the Visualization tool is not available issue the command RTRV-TOPO-OST and verify that all nodes in the network are listed as expected

Trang 37

Optical Multiservice Edge 6500 Fault Management - Customer Visible Logs

Release 6.0 Sep 2009

Copyright  2004-2009, Nortel Networks

Topology Build Failure - Invalid TCP message data from <TID>-SHELF> rem_path <PATH>

communication problem between network elements in the section

A retry mechanism will ensure that the channel topology is eventually discovered once the error condition is resolved

Troubleshooting information

available, a condition might exist on the network which is preventing normal communication between network elements This should be addressed using network troubleshooting techniques

clearing procedures

any NE is running an older release, proceed with the appropriate upgrade procedure to upgrade all NEs to the same software release

nodes in the network

Visualization tool (Network View) If the Visualization tool is not available issue the command RTRV-TOPO-OST and verify that all nodes in the network are listed as expected

—end—

Additional information

None

Trang 38

Topology Build Failure - Invalid TCP message data from <TID>-<SHELF>.

A retry mechanism will ensure that the channel topology is eventually discovered once the error condition is resolved

Troubleshooting information

available, a condition might exist on the network which is preventing normal communication between network elements This should be addressed using network troubleshooting techniques

clearing procedures

any NE is running an older release, proceed with the appropriate upgrade procedure to upgrade all NEs to the same software release

nodes in the network

Visualization tool (Network View) If the Visualization tool is not available issue the command RTRV-TOPO-OST and verify that all nodes in the network are listed as expected

—end—

Trang 39

Optical Multiservice Edge 6500 Fault Management - Customer Visible Logs

Release 6.0 Sep 2009

Copyright  2004-2009, Nortel Networks

Topology Build Failure - TCP/UDP message version mismatch detected by

<TID>-<SHELF> rem_path <PATH>

A retry mechanism will ensure that the channel topology is eventually discovered once the error condition is resolved

Troubleshooting information

available, a condition might exist on the network which is preventing normal communication between network elements This should be addressed using network troubleshooting techniques

clearing procedures

any NE is running an older release, proceed with the appropriate upgrade procedure to upgrade all NEs to the same software release

nodes in the network

Visualization tool (Network View) If the Visualization tool is not available issue the command RTRV-TOPO-OST and verify that all nodes in the network are listed as expected

—end—

Additional information

None

Trang 40

Topology Build Failure - TCP/UDP message version mismatch detected by

<TID>-<SHELF>, rem_path <PATH>