1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Kết nối WinCC với PLC s7 1200 và 1500

18 3,3K 5

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 18
Dung lượng 1,06 MB

Các công cụ chuyển đổi và chỉnh sửa cho tài liệu này

Nội dung

Warranty and LiabilityWinCC S7-1200/ S7-1500 Warranty and Liability Note The Application Examples are not binding and do not claim to be complete regarding the circuits shown, equipping

Trang 1

Configuration Example Ÿ 10/2014

WinCC Connection to

S7-1200 and S7-1500

WinCC V7.3

Trang 2

Warranty and Liability

WinCC S7-1200/ S7-1500

Warranty and Liability

Note The Application Examples are not binding and do not claim to be complete

regarding the circuits shown, equipping and any eventuality The Application Examples do not represent customer-specific solutions They are only intended

to provide support for typical applications You are responsible for ensuring that the described products are used correctly These Application Examples do not relieve you of the responsibility to use sound practices in application, installation, operation and maintenance When using these Application Examples, you recognize that we cannot be made liable for any damage/claims beyond the liability clause described We reserve the right to make changes to these Application Examples at any time and without prior notice If there are any deviations between the recommendations provided in these Application Examples and other Siemens publications – e.g Catalogs – the contents of the other documents have priority

We do not accept any liability for the information contained in this document Any claims against us – based on whatever legal reason – resulting from the use of the examples, information, programs, engineering and performance data etc., described in this Application Example shall be excluded Such an exclusion shall not apply in the case of mandatory liability, e.g under the German Product Liability Act (“Produkthaftungsgesetz”), in case of intent, gross negligence, or injury of life, body or health, guarantee for the quality of a product, fraudulent concealment of a deficiency or breach of a condition which goes to the root of the contract

(“wesentliche Vertragspflichten”) The damages for a breach of a substantial contractual obligation are, however, limited to the foreseeable damage, typical for the type of contract, except in the event of intent or gross negligence or injury to life, body or health The above provisions do not imply a change of the burden of proof to your detriment

Any form of duplication or distribution of these Application Examples or excerpts hereof is prohibited without the expressed consent of Siemens Industry Sector

Security

informa-tion

Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks They are important components in a holistic industrial security concept With this in mind, Siemens’ products and solutions undergo continuous development Siemens recommends strongly that you regularly check for product updates

For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g., cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept Third-party products that may be in use should also be considered For more information about industrial security, visithttp://www.siemens.com/industrialsecurity

To stay informed about product updates as they occur, sign up for a product-specific newsletter For more information, visit

http://support.automation.siemens.com

Trang 3

Table of Contents

Table of Contents

Warranty and Liability 2

1 Task 4

2 Solution 5

2.1 Overview 5

2.2 Hardware and software components 7

2.2.1 Validity 7

2.2.2 Components used 7

3 Configuration and Settings 9

3.1 Loading AS symbols from an existing S7-1500 program 9

3.2 Loading AS messages from an existing S7-1500 program 15

4 References 18

5 History 18

Trang 4

1 Task

WinCC S7-1200/ S7-1500

Figure 1-1

S7-1500

S7-1200

WinCC V7.3 Encrypted

process connection

Process connection

Introduction

The task is to provide process tags and AS messages of S7-1200 and S7-1500 in WinCC V7.3

It is to be possible to establish a protected HMI connection to S7-1500

Trang 5

2 Solution

2.1 Overview

2.1 Overview

Setup

The following scheme shows the most important components of the solution:

Figure 2-1

S7-1500

S7-1200

PROFINET IE

WinCC V7.3

SIMATIC S-1200, S7-1500 Channel

Description

WinCC V7.3 provides the communication channel "SIMATIC S7-1200, S7-1500 Channel" for communication with S7-1200 and S7-1500 CPUs

Communication to S7-1200 and S7-1500 can be realized with absolute addressing and since WinCC V7.3 also with symbolic addressing

Between WinCC V7.3 and S7-1500, a protected communication connection can be established

Characteristic features

· Access to the symbolic addresses and CPU alarming is effected via the online connection to the CPU only

· Offline configuration is only possible for the absolute addresses

Note Currently, no raw data tags can be used via the

"SIMATIC S7-1200, S7-1500 Channel"

Trang 6

2 Solution

2.1 Overview

WinCC S7-1200/ S7-1500

Features of the communication to S7-1200 and S7-1500

· Cyclic reading of tags

· Chronological reporting (program alarm)

· Loading of AS messages (S7-1500)

· Password protection

· Time synchronization

· Use of S7-1200/S7-1500 tags in WinCC – Export/Import function

1) Export of the tags from TIA Portal (only absolute addressing) 2) Import to WinCC via the WinCC Configuration Studio

· Loading of AS symbols

Delimitation

This application does not contain a description of:

· Configuration of S7-1500 in TIA Portal

· Installation of SIMATIC TIA Portal and WinCC V7.3 Basic knowledge of these topics is assumed

Assumed knowledge

Basic knowledge of WinCC V7.3 and SIMATIC TIA Portal is assumed

Trang 7

2 Solution

2.2 Hardware and software components

2.2 Hardware and software components

2.2.1 Validity

This application is valid for

· STEP 7 from V13

· WinCC V7.3

· S7-1200 (from firmware V2.2)

· S7-1500

2.2.2 Components used

The application was created with the following components:

Hardware components

Table 2-1

S7-1516-3 PN/DP 1 6AG1516-3AN00-7AB0 Alternatively, any other

S7-1500 or S7-1200 can be used Development

system

1 PC for configuration of

controller and WinCC.

The hardware requirements for STEP 7 and WinCC apply.

Software components

Table 2-2

WinCC V7.3 1 6AV63.1- 7-3

TIA Portal STEP 7 V13 Professional

1 6ES7822-1 03- Alternatively, TIA Portal

STEP 7 V13 Basic can be used for S7-1200.

NOTE Use the SIMATIC NET V12 installation being enclosed to WinCC V7.3 if no

STEP 7 or TIA Portal is installed on the computer (With it the communication drivers are installed.)

Sample files and projects

The following list includes all files and projects that are used in this example

Trang 8

2 Solution

2.2 Hardware and software components

WinCC S7-1200/ S7-1500

Table 2-3

color_filling_station.zip Getting Started

S7-1500 101908495_WinCC_S71200_S71500_Chanel_de.pdf This document.

Trang 9

3 Configuration and Settings

3.1 Loading AS symbols from an existing S7-1500 program

3.1 Loading AS symbols from an existing S7-1500 program

This section describes the configuration of tags in WinCC with optimized block access to the address range in the S7-1500 automation system

Table 3-1

Create a new WinCC project or open an existing one.

Open Tag Management.

Enter the IP address, access point, and product family.

3 Add a SIMATIC S7-1200, S7-1500 Channel.

Trang 10

3 Configuration and Settings

3.1 Loading AS symbols from an existing S7-1500 program

WinCC S7-1200/ S7-1500

4 Right-click and add a "New Connection".

5 Right-click and open the "Connection parameters".

Enter the new IP address of your S7-1500 or S7-1200 here.

Trang 11

3 Configuration and Settings

3.1 Loading AS symbols from an existing S7-1500 program

6 Optional: Realize a protected connection to S7-1500 by entering a password.

Note

Password protection is only provided by S7-1500 CPUs Further information is available in the manual:

"SIMATIC S7-1500 Automation System > Protection > Configuring access protection for the CPU " \3\

Start WinCC Runtime.

Trang 12

3 Configuration and Settings

3.1 Loading AS symbols from an existing S7-1500 program

WinCC S7-1200/ S7-1500

Right-click on the connection and go to "AS Symbols -> Read from AS" to read out the symbols of the S7-1500.

These are read now.

Confirm the message with OK.

Trang 13

3 Configuration and Settings

3.1 Loading AS symbols from an existing S7-1500 program

9 The symbols of the S7-1500 are now listed under "AS Symbols":

10 By checking the "Access" check box, the tags with symbolic addressing are

automatically created.

11 These are now displayed on the "Tags" tab together with their properties.

Trang 14

3 Configuration and Settings

3.1 Loading AS symbols from an existing S7-1500 program

WinCC S7-1200/ S7-1500

12 You can change the tag name on the "Tags" and "AS Symbols" tabs.

Note If modifications are made to the controller, it is necessary to execute the

"Read from AS" command again

Note If WinCC Runtime is stopped and Tag Management is closed, neither the

symbolic addressing nor the "AS Symbols" tab is displayed any longer Both can be displayed in Tag Management again with the "Read from AS" command

Trang 15

3 Configuration and Settings

3.2 Loading AS messages from an existing S7-1500 program

3.2 Loading AS messages from an existing S7-1500

program

Table 3-2

1 Open the "Alarm logging" editor.

Trang 16

3 Configuration and Settings

3.2 Loading AS messages from an existing S7-1500 program

WinCC S7-1200/ S7-1500

2 Under "AS Messages", right-click on the connection "NewConnection_1" to

open the context menu.

3 Click on "Load from AS" to import the system messages.

Trang 17

3 Configuration and Settings

3.2 Loading AS messages from an existing S7-1500 program

4 Now the tabs "AS Messages" and "AS Text lists" are available.

Note Loading the AS messages is only possible with an S7-1500

Trang 18

4 References

WinCC S7-1200/ S7-1500

Table 4-1

\1\ Siemens Industry Online Support

http://support.automation.siemens.com

\2\ Download page of the entry

http://support.automation.siemens.com/WW/view/en/101908495

\3\ S7-1500 Manual;

Access Protection

https://www.automation.siemens.com/mdm/default.aspx?DocVersionI d=63956397195&TopicId=62467847691

Table 5-1

V1.0 10/2014 First version