May 2011 Mai 2011 IEC 61010 1 (3rd edition – 2010) Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 1 General requirements CEI 61010 1 (3ème édition – 2[.]

Trang 1

May 2011 Mai 2011

IEC 61010-1 (3rd edition – 2010) Safety requirements for electrical equipment for

measurement, control, and laboratory use –

Part 1: General requirements

CEI 61010-1 (3ème édition – 2010) Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire – Partie 1: Exigences générales

C O R R I G E N D U M 1

French corrections follow English text

Table 6 – CLEARANCES and test voltages for secondary circuits derived from MAINS

CIRCUITS of OVERVOLTAGE CATEGORY II up to 300 V

Replace Table 6 with the following table:

Trang 2

May 2011 Mai 2011

Table 6 – CLEARANCES and test voltages for secondary circuits derived from MAINS

CIRCUITS of OVERVOLTAGE CATEGORY II up to 300 V

Secondary

W ORKING VOLTAGE

MAINS voltage, line-to-neutral, OVERVOLTAGE CATEGORY II

150 V a.c r.m.s

> 150 V ≤ 300 V a.c r.m.s

a.c r.m.s

V

d.c or a.c peak

V

C LEARANCE

mm

Test voltage

V a.c r.m.s

C LEARANCE

mm

Test voltage

V a.c r.m.s

16

33

50

100

150

300

600

1 000

1 250

1 600

2 000

2 500

3 200

4 000

5 000

6 300

8 000

10 000

12 500

16 000

20 000

25 000

32 000

40 000

50 000

63 000

22,6 46,7

70

140

210

420

840

1 400

1 750

2 240

2 800

3 500

4 480

5 600

7 000

8 820

11 200

14 000

17 500

22 400

28 000

35 000

44 800

56 000

70 000

88 200

0,10 0,11 0,12 0,13 0,16 0,39 1,01 1,92 2,50 3,39 4,49 6,02 8,37 10,9 14,0 18,2 23,9 30,7 39,6 52,5 67,9 87,9

117

151

196

258

500

510

520

540

580

770

1 070

1 630

1 960

2 390

2 890

3 520

4 390

5 320

6 590

8 270

10 400

12 900

16 100

20 400

25 300

31 600

40 400

50 300

62 800

79 400

0,50 0,52 0,53 0,61 0,69 0,94 1,61 2,52 3,16 4,11 5,30 6,91 9,16 11,6 14,9 19,1 24,7 31,6 40,5 53,5 68,9 89,0

118

153

198

260

840

850

860

900

940

1 040

1 450

1 970

2 280

2 730

3 230

3 850

4 660

5 610

6 960

8 620

10 700

13 300

16 400

20 700

25 600

32 000

40 700

50 800

63 400

80 000 Linear interpolation is allowed

Trang 3

May 2011 Mai 2011

Table K.9 – Minimum values for distance or thickness of solid insulation

Replace Table K.9 with the following table:

Table K.9 – Minimum values for distance or thickness of solid insulation

Line-to-neutral voltage Minimum thickness

a

Minimum distance L (see Figure K.2)

a, b

a These values are independent of the OVERVOLTAGE CATEGORY

b These values apply for BASIC INSULATION, SUPPLEMENTARY INSULATION and REINFORCED INSULATION

Trang 4

May 2011 Mai 2011

French text :

Tableau 6 – DISTANCES D’ISOLEMENT et tensions d’essai des circuits secondaires dérivés

des CIRCUITS RÉSEAU en CATÉGORIE DE SURTENSION II jusqu’à 300 V

Remplacer le Tableau 6 existant par le suivant:

Trang 5

May 2011 Mai 2011

des CIRCUITS RÉSEAU en CATÉGORIE DE SURTENSION II jusqu’à 300 V

T ENSION DE SERVICE

au secondaire

Tension RÉSEAU , phase-neutre, CATÉGORIE DE SURTENSION II

150 V alternatif efficace alternatif efficace > 150 ≤ 300 V Alternatif

efficace alternatif crête Continu ou D ’ D ISOLEMENT ISTANCE Tension d’essai D ’ D ISOLEMENT ISTANCE Tension d’essai

16

33

50

100

150

300

600

1 000

1 250

1 600

2 000

2 500

3 200

4 000

5 000

6 300

8 000

10 000

12 500

16 000

20 000

25 000

32 000

40 000

50 000

63 000

22,6 46,7

70

140

210

420

840

1 400

1 750

2 240

2 800

3 500

4 480

5 600

7 000

8 820

11 200

14 000

17 500

22 400

28 000

35 000

44 800

56 000

70 000

88 200

0,10 0,11 0,12 0,13 0,16 0,39 1,01 1,92 2,50 3,39 4,49 6,02 8,37 10,9 14,0 18,2 23,9 30,7 39,6 52,5 67,9 87,9

117

151

196

258

500

510

520

540

580

770

1 070

1 630

1 960

2 390

2 890

3 520

4 390

5 320

6 590

8 270

10 400

12 900

16 100

20 400

25 300

31 600

40 400

50 300

62 800

79 400

0,50 0,52 0,53 0,61 0,69 0,94 1,61 2,52 3,16 4,11 5,30 6,91 9,16 11,6 14,9 19,1 24,7 31,6 40,5 53,5 68,9 89,0

118

153

198

260

840

850

860

900

940

1 040

1 450

1 970

2 280

2 730

3 230

3 850

4 660

5 610

6 960

8 620

10 700

13 300

16 400

20 700

25 600

32 000

40 700

50 800

63 400

80 000 L'interpolation linéaire est permise

Trang 6

May 2011 Mai 2011

Tableau K.9 – Valeurs minimum de la distance ou de l’épaisseur de l’isolation solide

Remplacer le Tableau K.9 existant par le suivant:

Tableau K.9 – Valeurs minimum de la distance ou de l’épaisseur de l’isolation solide

Tension phase-neutre alternative efficace

ou continue

Epaisseur minimale

a

Distance minimale L (voir la Figure K.2)

a, b

a Ces valeurs ne dépendent pas de la CATÉGORIE DE SURTENSION

b Ces valeurs s’appliquent pour l’ISOLATION PRINCIPALE, l’ISOLATION SUPPLÉMENTAIRE

et l’ISOLATION RENFORCÉE