It can be classified as either: a closed as described in 3.1.2 or; b open as described in 3.1.3 3.1.2 closed barbecue appliance designed for cooking outdoors by means of radiant and con
Trang 1BSI Standards Publication
Appliances, solid fuels and firelighters for
barbecueing
Part 1: Barbecues burning solid fuels — Requirements and test methods
Trang 2This British Standard is the UK implementation of EN 1860-1:2013 It supersedes BS EN 1860-1:2003 which is withdrawn.
The UK participation in its preparation was entrusted by Technical Committee RHE/28, Domestic solid mineral fuel appliances, to Subcommittee RHE/28/1, Appliances, solid fuels and firestarters for barbecuing
The UK committee voted against approval of this European Standard due to the absence of a product labelling requirement that adequately highlights the risk of fatal carbon monoxide poisoning that can be posed by use of these products EN 1860-1 will shortly be amended by CEN to address this and it has been requested by the committee to issue similar amendments to EN 1860-2, EN 1860-3 and EN 1860-4 However in regard to concerns in the UK relating to incidences of carbon monoxide poisoning please refer to the National Annex for best practice guidance.National Annex NA (informative), found at the end of this document, offers recommendations for the marking of products made in
accordance with 1860-1
A list of organizations represented on this subcommittee can be obtained on request to its secretary
This publication does not purport to include all the necessary provisions
of a contract Users are responsible for its correct application
© The British Standards Institution 2014
Published by BSI Standards Limited 2014ISBN 978 0 580 77058 6
Amendments/corrigenda issued since publication
Date Text affected
Trang 3NORME EUROPÉENNE
English Version
Appliances, solid fuels and firelighters for barbecueing - Part 1:
Barbecues burning solid fuels - Requirements and test methods
Appareils, combustibles solides et allume-feu pour la
cuisson au barbecue - Partie 1: Barbecues utilisant les
combustibles solides - Exigences et méthodes d'essai
Geräte, feste Brennstoffe und Anzündhilfen zum Grillen - Teil 1: Grillgeräte für feste Brennstoffe - Anforderungen und
Prüfverfahren
This European Standard was approved by CEN on 16 September 2012
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member
This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom
EUROPEAN COMMITTEE FOR STANDARDIZATION
C O M IT É E U R O P É E N D E N O R M A LIS A T IO N EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2013 CEN All rights of exploitation in any form and by any means reserved Ref No EN 1860-1:2013: E
Trang 4Contents
PageForeword 3
Introduction 4
1 Scope 5
2 Normative references 5
3 Terms and definitions 5
4 Requirements 7
4.1 General requirements 7
4.2 Requirements for parts 8
4.2.1 Cooking grid 8
4.2.2 Rotisserie spit 9
4.2.3 Fuel compartment 9
4.2.4 Ash compartment or catcher 11
4.2.5 Gravy tray or drip pan 12
4.2.6 Stand 12
4.2.7 Handles or gripping devices 12
4.2.8 Motor 14
5 Test methods 14
5.1 General 14
5.2 Thermal test 14
5.2.1 General 14
5.2.2 Thermal test of use 14
5.2.3 Safety test 17
5.3 Combustibility 18
5.4 Stability 18
5.4.1 Barbecues and suitcase barbecues 18
5.4.2 Permanent barbecues 18
5.5 Handling 20
5.6 Cooking grid 20
5.7 Perforation test 21
6 Marking 23
7 Instructions for use 23
Annex A (informative) Mandatory sentences 25
Bibliography 31
Trang 5Contents
PageForeword 3
Introduction 4
1 Scope 5
2 Normative references 5
3 Terms and definitions 5
4 Requirements 7
4.1 General requirements 7
4.2 Requirements for parts 8
4.2.1 Cooking grid 8
4.2.2 Rotisserie spit 9
4.2.3 Fuel compartment 9
4.2.4 Ash compartment or catcher 11
4.2.5 Gravy tray or drip pan 12
4.2.6 Stand 12
4.2.7 Handles or gripping devices 12
4.2.8 Motor 14
5 Test methods 14
5.1 General 14
5.2 Thermal test 14
5.2.1 General 14
5.2.2 Thermal test of use 14
5.2.3 Safety test 17
5.3 Combustibility 18
5.4 Stability 18
5.4.1 Barbecues and suitcase barbecues 18
5.4.2 Permanent barbecues 18
5.5 Handling 20
5.6 Cooking grid 20
5.7 Perforation test 21
6 Marking 23
7 Instructions for use 23
Annex A (informative) Mandatory sentences 25
Bibliography 31
Foreword
This document (EN 1860-1:2013) has been prepared by Technical Committee CEN/TC 281 “Appliances, solid fuels and firelighters for barbecuing”, the secretariat of which is held by AENOR
This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by July 2013, and conflicting national standards shall be withdrawn at the latest by January 2014
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights This document supersedes EN 1860-1:2003
The main technical modifications are the following:
a Clause 3, Terms and definitions: definition of BBQ modified to introduce Close and Open barbecues;
b 4.2.3.1: measurement of thickness added;
c New 4.2.4, Ash compartment or catcher;
d 4.2.7: Table 3 modified;
e Clause 5, Test Methods: Test methods modified A thermal test of use and a safety test were added;
f New Annex A
This European Standard on appliances, solid fuels and firelighters for barbecuing consists of the following
parts:
Part 1: Barbecues burning solid fuels — Requirements and test methods Part 2: Barbecue charcoal and barbecue charcoal briquettes — Requirements and test methods Part 3: Firelighters for igniting solid fuels for use in barbecue appliances — Requirements and test methods Part 4: Single use barbecues burning solid fuels — Requirements and test methods
According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom
Trang 7Introduction
This standard is part 1 of the European Standard for appliances, solid fuels and firelighters for barbecuing,
which is intended to reduce the risks which can occur during and through barbecuing with solid fuels
This part should be read in conjunction with parts 2 and 3
EN 1860-2, Appliances, solid fuels and firelighters for barbecuing — Part 2: Barbecue charcoal and barbecue
charcoal briquettes — Requirements and test methods
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply
3.1 barbecue
appliance designed for outdoor cooking in the open air which is divided into the following categories
3.1.1 suitcase barbecue or portable barbecue
appliance that can be carried with one hand without parts falling of when dismantled or folded It can be classified as either:
a) closed as described in 3.1.2 or;
b) open as described in 3.1.3
3.1.2 closed barbecue
appliance designed for cooking outdoors by means of radiant and convection heat consisting at least of a fuel compartment, a lid which may have air vents, a cooking grid and/or a rotisserie
3.1.3 open barbecue
appliance designed for cooking outdoors by means of radiant heat consisting at least of a fuel compartment, a cooking grid and/or a rotisserie
Trang 83.1.4
permanent barbecue
outdoor barbecue designed to be permanently installed It may consist of pre-fabricated elements fitted together and may include a pre-fabricated hood It may have removable parts, and be classified as either: a) closed as described in 3.1.2 or;
ash compartment or catcher
part of the barbecue intended to catch any ash or embers which may fall from the fuel compartment or fuel grate
rotisserie meat forks
clamping devices on the rotisserie spit that can be slid onto and fixed in any position on which the food to be cooked can be secured
Trang 93.1.4
permanent barbecue
outdoor barbecue designed to be permanently installed It may consist of pre-fabricated elements fitted
together and may include a pre-fabricated hood It may have removable parts, and be classified as either:
a) closed as described in 3.1.2 or;
b) open as described in 3.1.3
3.2
fuel compartment
part of the barbecue where the fuel is burnt; it may have, or be a fuel grate and may have air vents In closed
barbecues the fuel compartment is the fuel grate or the fuel grate with fuel rails or baskets or a fuel tray
3.3
fuel grate
perforated part of the barbecue on which the fuel is placed
3.4
ash compartment or catcher
part of the barbecue intended to catch any ash or embers which may fall from the fuel compartment or fuel
metal rod suitable for skewering the food to be cooked via the truncated cone on one side and which can be
rotated by hand and/or via a motor in a suitable support
3.5.3
rotisserie meat forks
clamping devices on the rotisserie spit that can be slid onto and fixed in any position on which the food to be
cooked can be secured
any area of a barbecue component and accessories, as described in 3.5 through 3.5.4,intended to come into
contact with the food to be barbecued during cooking is regarded as being usable
3.8
drip pan
device to collect waste drippings not to be consumed
3.9 stand
support structure of a barbecue onto which the functional parts of the barbecue are located
3.10 silk paper
thin, soft, relatively hard to tear paper with a weight between 12 g/m2 and 25 g/m2 usually used to wrap delicate objects
3.11 windshield
component of the barbecue used to minimise undesirable effect of the wind during the use of the barbecue
4 Requirements 4.1 General requirements
When testing as described in 5.2, the coatings of the barbecue accessories shall not liberate any solid substance nor ignite Also any solid substance coming from other parts of the barbecue shall not ignite nor fall into the usable area
NOTE For surfaces of and coatings on parts of the barbecue coming into contact with the food to be barbecued, cooking grid, rotisserie spit, rotisserie meat forks and gravy trays, see Regulation (EC) No 1935/2004 (see Bibliography) Differing legal requirements may exist in non-EU-countries
It shall be possible to assemble and dismantle suitcase or portable barbecues as described in the instructions for use either without the aid of a tool or using the tool that is supplied Components shall be fixed in such a way that they cannot fall off during transportation
When assembling, operating and manipulating the barbecue, accessible edges and corners shall be free from burr Rough surfaces, sharp edges and corners, which can cause injury, are not allowed
In case of doubt to determine whether rough surface, sharp edges or corners can cause an injury a test according to EN 71-1:2009, 8.11 is mandatory
All accessible parts of the barbecue components made of metal sheet or tubes of thickness less than 0,7 mm (– 0,02 mm) coating excluded shall be as shown in Figures 1, 2, 3 and 4
Figure 1 — Fully edged
Figure 2 — Folded and flattened
Trang 10Figure 3 — Rolled and closed
Figure 4 — Rolled and half closed
The construction of the barbecue shall be such that when placed horizontally the change of the fuel compartment position, according to the instruction for use and the insertion and removal of barbecue accessories with the cooking grid and/or rotisserie spit loaded as described in 5.5, shall be possible without the barbecue tipping over or components becoming detached or moved in such a way that they are no longer capable of fulfilling their functions These requirements also apply when testing the barbecue as described
in 5.2
After testing in accordance with Clause 5, a barbecue fails if it does not meet the following requirements: a) any deformation of a component that compromises the use and safety of the barbecue;
b) any component showing cracks and/or fractures;
NOTE A permanent barbecue may show cracks and/or fractures which do not influence the safety
c) any component falls off;
d) the temperature and safety requirements mentioned in the test descriptions are not met
4.2 Requirements for parts
4.2.1 Cooking grid
The clear distance between the bars of the cooking grid shall not exceed 20 mm before, during and after testing according to 5.2 and 5.6 This requirement relates to the usable area of the grid, which shall be at least 80 % of the horizontal area of the fuel compartment, vertically projected
If the cooking grid has the function of a grate, the clear distance between the bars of the grate and also, in the case of vertical fuel compartment, of those between the grate and the edges of the fuel container shall not exceed 20 mm before, during and after testing according to 5.2 and 5.6
Trang 11Figure 3 — Rolled and closed
Figure 4 — Rolled and half closed
The construction of the barbecue shall be such that when placed horizontally the change of the fuel
compartment position, according to the instruction for use and the insertion and removal of barbecue
accessories with the cooking grid and/or rotisserie spit loaded as described in 5.5, shall be possible without
the barbecue tipping over or components becoming detached or moved in such a way that they are no longer
capable of fulfilling their functions These requirements also apply when testing the barbecue as described
in 5.2
After testing in accordance with Clause 5, a barbecue fails if it does not meet the following requirements:
a) any deformation of a component that compromises the use and safety of the barbecue;
b) any component showing cracks and/or fractures;
NOTE A permanent barbecue may show cracks and/or fractures which do not influence the safety
c) any component falls off;
d) the temperature and safety requirements mentioned in the test descriptions are not met
4.2 Requirements for parts
4.2.1 Cooking grid
The clear distance between the bars of the cooking grid shall not exceed 20 mm before, during and after
testing according to 5.2 and 5.6 This requirement relates to the usable area of the grid, which shall be at
least 80 % of the horizontal area of the fuel compartment, vertically projected
If the cooking grid has the function of a grate, the clear distance between the bars of the grate and also, in the
case of vertical fuel compartment, of those between the grate and the edges of the fuel container shall not
exceed 20 mm before, during and after testing according to 5.2 and 5.6
The cooking grid shall rest on its supporting points in the most unfavourable position when loaded as described in 5.5 When the load has been removed the deformation of each grid bar shall not exceed 5 % relative to the length of the bar when tested according to 5.6
Manually adjustable cooking grids up to 400 mm diameter or longest side measurement shall be fitted with one handle minimum, cooking grids over 400 mm diameter or longest side measurement shall be fitted with two handles If the cooking grid position is adjustable, this adjustment shall be possible without the operator's hand coming into direct contact with the cooking grid
Removable or movable handles shall be attached to the cooking grid in such a way that tipping to the side or forwards when loaded as described in 5.5 shall be impossible
Handle is not required when the height of the cooking grid can be adjusted through a mechanical device The barbecue shall be designed in such a way that when the fuel compartment is uniformly loaded to 75 % of its capacity, the cooking grid in its most unfavourable position shall not come into contact with the fuel
4.2.2 Rotisserie spit
The end of the rotisserie spit shall have the shape of a truncated cone of minimum diameter not less than 1,5 mm and not exceeding 3 mm and a taper angle between 60° and 90°
The rotisserie spit shall have a permanent or removable handle of at least 100 mm usable length
The handle for any motor supplied with it shall be 80 mm minimum length
If the distance between the support points of the rotisserie spit exceeds 800 mm a second handle shall be provided unless the motor has the function of a handle
The handle (or handles) shall be fitted to the rotisserie spit in such a way that when tested in accordance with 5.2.2 the surface temperatures shall not exceed the values specified in Table 3
The rotisserie spit shall have a minimum of two adjustable and fixable rotisserie meat forks
When loading the rotisserie spit with 0,5 kg per 100 mm usable length it shall rest on all its supporting points The other components of the barbecue or the fuel load following the instructions for use shall not come into contact with a cylinder 200 mm in diameter and of a length equivalent to at least 60 % of the usable rotisserie spit length placed centrally around the rotisserie spit and in the centre of the rotisserie spit If several rotisserie spit positions are possible, this requirement shall be met for at least one position
4.2.3 Fuel compartment 4.2.3.1 General
Fuel compartments made of steel sheet require a minimum thickness (coating excluded) as specified in Table 1
The thickness shall be measured in three different points:
one to be in the centre of the bottom;
two on the opposite sides at minimum 150 mm from each other;
If one side of the fuel compartment is a grate, only two sides are measured
Trang 12The thickness shall be considered the average of the measurements
NOTE On finished products ready to be commercialised:
1) Measure the total thickness “Tt” in the three points of the fuel compartment
2) Measure at these same points on both sides the thickness of the coating Cext and Cint
3) Calculate by subtraction the thickness of the uncoated steel sheet in each T = Tt – (Cext + Cint)
4) Calculate the average from them
Table 1 — Minimum thickness of steel sheet for fuel compartments Grid size diameter or longest side
≤ 400 mm
> 400 mm
0,7 mm 0,8 mm
For fuel compartments with a grid size diameter or longest side measurement ≤ 400 mm, a thickness (coating excluded) between 0,5 mm and 0,7 mm is acceptable, provided they are glass or porcelain enamelled on both sides and withstand the tests according to:
a) 5.2.2 one time and 5.2.3 two times consecutively; and
b) 5.7
Fuel compartments made of cast metal require a minimum thickness coating excluded of 2,5 mm
Fuel compartments made of materials other than steel sheet or cast material (excluding permanent barbecues) shall withstand the tests according to:
a) 5.2.2 one time and 5.2.3 two times consecutively; and
Other openings, other than in the flat base, if circular should have a diameter not exceeding 8 mm, or, if a different shape, their area shall not exceed 50 mm2
With larger openings the barbecue shall be equipped with an ash catcher or the barbecue shall be designed
so that it is impossible for any embers or fuel to fall out or roll off when tested as described in 5.2 and 5.3
4.2.3.3 Depth of the fuel compartment
The minimum depth of the fuel compartment shall be as indicated in Table 2 The minimum depth shall be available over 80 % of the usable area of the fuel compartment
Trang 13The thickness shall be considered the average of the measurements
NOTE On finished products ready to be commercialised:
1) Measure the total thickness “Tt” in the three points of the fuel compartment
2) Measure at these same points on both sides the thickness of the coating Cext and Cint
3) Calculate by subtraction the thickness of the uncoated steel sheet in each T = Tt – (Cext + Cint)
4) Calculate the average from them
Table 1 — Minimum thickness of steel sheet for fuel compartments Grid size diameter or longest side
≤ 400 mm
> 400 mm
0,7 mm 0,8 mm
For fuel compartments with a grid size diameter or longest side measurement ≤ 400 mm, a thickness (coating
excluded) between 0,5 mm and 0,7 mm is acceptable, provided they are glass or porcelain enamelled on both
sides and withstand the tests according to:
a) 5.2.2 one time and 5.2.3 two times consecutively; and
b) 5.7
Fuel compartments made of cast metal require a minimum thickness coating excluded of 2,5 mm
Fuel compartments made of materials other than steel sheet or cast material (excluding permanent
barbecues) shall withstand the tests according to:
a) 5.2.2 one time and 5.2.3 two times consecutively; and
b) 5.7
4.2.3.2 Openings
If the fuel compartment after assembly has openings, these shall meet the following requirements when tested
as described in 5.2 and 5.3
The number of openings in the flat base of the fuel compartment shall not exceed four and shall be
dimensioned so that a sphere of 3 mm in diameter will not fall through them, their area shall not
exceed 50 mm2
Other openings, other than in the flat base, if circular should have a diameter not exceeding 8 mm, or, if a
different shape, their area shall not exceed 50 mm2
With larger openings the barbecue shall be equipped with an ash catcher or the barbecue shall be designed
so that it is impossible for any embers or fuel to fall out or roll off when tested as described in 5.2 and 5.3
4.2.3.3 Depth of the fuel compartment
The minimum depth of the fuel compartment shall be as indicated in Table 2 The minimum depth shall be
available over 80 % of the usable area of the fuel compartment
Table 2 — Minimum depth of the fuel compartment Grid size diameter or longest side
≤ 400 mm
> 400 mm
50 mm
60 mm
If the fuel compartment is a grate Table 2 shall not be taken into account but it shall have an ash catcher
If the fuel compartment has several possible positions, stops shall be provided to secure it in each of these positions
For permanent barbecues part of the structure can be used as the fuel compartment when calculating the minimum depth shown in Table 2
For the permanent barbecue the front side of the fuel compartment can be open if it’s protected by a flat protection plane minimum 130 mm deep to prevent embers from falling to the ground as shown in Figure 5
Dimensions in millimetres
Keys
A fuel compartment
B flat protection plane
Figure 5 — Top view of flat protection plane for permanent barbecue 4.2.4 Ash compartment or catcher
Ash compartments or catcher made of sheet metal require a minimum thickness (coating excluded) of 0,7
mm
For ash compartments or catchers with a diameter or longest side measurement ≤ 400 mm, a thickness (coating excluded) between 0,5 mm and 0,7 mm is acceptable, provided they are glass or porcelain enamelled on both sides
Trang 144.2.5 Gravy tray or drip pan
If the barbecue has a gravy tray or drip pan with the barbecue in the horizontal position it shall either be arranged in such a way that its contents flow away from the fuel compartment or have a recess at least 5 mm deep and the horizontal distance between the grate and the beginning of the recess shall be at least 30 mm, when the base of the gravy tray or drip pan is horizontal
If the stand or barbecue has wheels or castors to enable it to be moved:
a) no parts or accessories shall fall off during movement;
b) means shall be provided to prevent accidental movement of the stand or barbecue during normal use; This requirement is satisfied if:
at least one of the wheels or castors is fitted with a brake or a blocking system; or
at least one of the support points of the barbecue is not made of a wheel or a castor;
c) a gripping device shall be provided to move the barbecue safely while cold
4.2.7 Handles or gripping devices
Lid and adjustable cooking grid handles shall have a usable length of minimum 80 mm Separate requirements apply for rotisserie spit handles (see 4.2.2)
The temperature shall be taken only of lid and adjustable cooking grid handles which are needed during operation of the barbecue
The temperature of all other handles or gripping devices (e.g air control of lid, ash tray or non adjustable cooking grid) shall not be taken if the manufacturer clearly states the use of mitts, gloves or a tool in the instructions for use (e.g pictogram or a sentence)
The surface temperatures over the full usable part of the handle or gripping device shall not exceed the values specified in Table 3 when tested in accordance with 5.2.2 In case of handles uniform in shape and longer than 80 mm, temperatures shall be measured as shown in Figures 6 and 7
Table 3 — Surface temperatures over ambient temperature
Trang 154.2.5 Gravy tray or drip pan
If the barbecue has a gravy tray or drip pan with the barbecue in the horizontal position it shall either be
arranged in such a way that its contents flow away from the fuel compartment or have a recess at least 5 mm
deep and the horizontal distance between the grate and the beginning of the recess shall be at least 30 mm,
when the base of the gravy tray or drip pan is horizontal
4.2.6 Stand
If the stand is foldable, the folding elements shall be capable of being locked in the operating position of the
barbecue A locking and/or unlocking device shall not operate unintentionally
The stand shall support the barbecue when tested in any position as described in 5.4 The barbecue shall not
tip over and when used in accordance with the instructions for use no components shall fall off
If the stand or barbecue has wheels or castors to enable it to be moved:
a) no parts or accessories shall fall off during movement;
b) means shall be provided to prevent accidental movement of the stand or barbecue during normal use;
This requirement is satisfied if:
at least one of the wheels or castors is fitted with a brake or a blocking system; or
at least one of the support points of the barbecue is not made of a wheel or a castor;
c) a gripping device shall be provided to move the barbecue safely while cold
4.2.7 Handles or gripping devices
Lid and adjustable cooking grid handles shall have a usable length of minimum 80 mm Separate
requirements apply for rotisserie spit handles (see 4.2.2)
The temperature shall be taken only of lid and adjustable cooking grid handles which are needed during
operation of the barbecue
The temperature of all other handles or gripping devices (e.g air control of lid, ash tray or non adjustable
cooking grid) shall not be taken if the manufacturer clearly states the use of mitts, gloves or a tool in the
instructions for use (e.g pictogram or a sentence)
The surface temperatures over the full usable part of the handle or gripping device shall not exceed the values
specified in Table 3 when tested in accordance with 5.2.2 In case of handles uniform in shape and longer
than 80 mm, temperatures shall be measured as shown in Figures 6 and 7
Table 3 — Surface temperatures over ambient temperature
Trang 164.2.8 Motor
For a barbecue supplied with a motor with spring winding or battery operated, or if the use of a specific motor
is permitted by the instructions for use, the following shall apply:
the motor shall operate the rotisserie spit for at least 30 min without having to rewind the motor or replace the batteries;
there shall be no risk, when rewinding the motor or replacing the batteries of the operators hand coming into contact with other part of the barbecue with surface temperatures exceeding the values specified
in Table 3
This requirement applies for the rotisserie spit loaded as described in 4.2.2
The motors supplied shall still be capable of moving the rotisserie spit loaded as described in 4.2.2 after testing in accordance with 5.2
5 Test methods
5.1 General
The requirements given in Clause 4 shall be verified by visual examination, linear measurement, function testing and/or calculation, unless otherwise specified
Testing shall be carried out with charcoal/charcoal briquettes as defined in EN 1860-2
Testing shall be carried out at an ambient temperature of (20 ± 5) °C, in still air (airspeed less than 0,5 m/s) For testing purposes each individual weight shall not exceed 0,5 kg and 100 mm in any dimension
5.2 Thermal test
5.2.1 General
The thermal test shall be performed in two parts
For barbecues with several fuel compartments which may be operated separately or simultaneously, the test shall be carried out in the most unfavourable combination
If the fuel compartment or the compartments have several positions the testing shall be carried out in each position
After thermal tests verify whether the marking as specified in Clause 6 is still legible or has not come away
5.2.2 Thermal test of use
Trang 174.2.8 Motor
For a barbecue supplied with a motor with spring winding or battery operated, or if the use of a specific motor
is permitted by the instructions for use, the following shall apply:
the motor shall operate the rotisserie spit for at least 30 min without having to rewind the motor or replace
the batteries;
there shall be no risk, when rewinding the motor or replacing the batteries of the operators hand coming
into contact with other part of the barbecue with surface temperatures exceeding the values specified
in Table 3
This requirement applies for the rotisserie spit loaded as described in 4.2.2
The motors supplied shall still be capable of moving the rotisserie spit loaded as described in 4.2.2 after
testing in accordance with 5.2
5 Test methods
5.1 General
The requirements given in Clause 4 shall be verified by visual examination, linear measurement, function
testing and/or calculation, unless otherwise specified
Testing shall be carried out with charcoal/charcoal briquettes as defined in EN 1860-2
Testing shall be carried out at an ambient temperature of (20 ± 5) °C, in still air (airspeed less than 0,5 m/s)
For testing purposes each individual weight shall not exceed 0,5 kg and 100 mm in any dimension
5.2 Thermal test
5.2.1 General
The thermal test shall be performed in two parts
For barbecues with several fuel compartments which may be operated separately or simultaneously, the test
shall be carried out in the most unfavourable combination
If the fuel compartment or the compartments have several positions the testing shall be carried out in each
position
After thermal tests verify whether the marking as specified in Clause 6 is still legible or has not come away
5.2.2 Thermal test of use
5.2.2.1 General
The appliance, positioned is placed on a 25 mm thick wooden horizontal panel with the surface coated with
matt black paint as shown in Figures 8 and 9
Thermocouple sensors are located in the panel at the centre of 200 mm squares, 3 mm from the surface of
the panel
Dimensions in millimetres
Figure 8 — View of alternative thermocouple sensors positioning
Dimensions in millimetres
Figure 9 — Top view of thermocouple sensors positioning in a matt black painted surface
For permanent barbecues the temperature on the floor temperature measurement is not required and the combustibility test shall be carried out as described in 5.3
Trang 185.2.2.2 Closed barbecues
The barbecue shall be loaded with fuel according to manufacturers' instructions (quantity and kind of fuel) If, there are several fuel load recommendations, the fuel load shall be done in the most unfavourable condition for the heating of the handles of the cooking grid (which can be handled during cooking) and the horizontal plane
The fuel load shall produce an average temperature of 200 °C for a duration of 20 min (starting when the centre has reached 200 °C) measured in one central point by thermocouple
In this case the lid shall be closed according to manufacturer’s instruction
In the case of utilisation of a rotisserie spit only, the temperature will be measured in three points centred on the rotisserie spit and distant of 100 mm
Handles temperature shall be taken by contact sensor only
This measurement shall be taken as soon as the temperature of the cooking grid (previously described in this subclause) will be at its maximum temperature
Thermal tests shall comply:
with requirements of 4.2.7 for the handles;
the temperature of the horizontal plane, on which the barbecue is placed shall not exceed the ambient temperature by more than 50 K
5.2.2.3 Open barbecues
The fuel compartment of the barbecue shall be completely filled with lump charcoal according to EN 1860-2
up to the cooking grid in its lowest position
This filling is removed from the fuel compartment and weighed
Then 75 % of the weight is refilled into the fuel compartment and ignited
Handles temperature shall be taken by contact sensor only
Thermal tests shall comply:
with requirements of 4.2.7 for the handles;
the temperature of the horizontal plane, on which the barbecue is placed shall not exceed the ambient temperature by more than 50 K
5.2.2.4 Permanent barbecues
The barbecue shall be loaded with fuel according to manufacturers' instructions (quantity and kind of fuel)
If, there are several fuel load recommendations, the fuel load shall be done in the most unfavourable condition for the heating of the handles of the cooking grid (which can be handled during cooking) and the horizontal plane
If wood and charcoal are both allowed the test shall be performed with charcoal
Handles temperature shall be taken by contact sensor only