When CON_02 Application of Control (CON) Group is selected as “WEB Control”, you can select the following function in addition. For further detail, please refer to WEB group function explanation.
Functio nCode
Loader Display
Definition of Function
Unit Explanation of Function Name Setting Range
DIO_41 AX1 Define
Web Break
Detection WEB Break % Detects and outputs the short of Web Up to Speed
Detection Up to Spd % Detects and outputs the deviation between line speed command and actual line speed False Core
Detection False Core % Outputs if the diameter is less than the set value in WEB_16
The rest of the multi-function output terminal has the same function. In the standard input/output board, however, AX1 and AX2 are relay output while OC1 is open collector output.
7.5.3 Analog Input/Output Group (AIO_[][])
If you select “WEB Control” at CON_02 Application, you can select following functions more. The function description is simple, so refer to WEB Group function description for more details.
Functio n Code
Loader Display
Definition of Function
Unit Explanation of Function Name Setting Range
AIO_01 Ai1 Define
Line Speed Command Line SPD Ref %
The set value of WEB_08 MaxMotor SPD is maximum line speed command 0 ~ 100% where the input is 0 ~ 10V. In case of ±10V input, it recognizes 0 ~ 10V.
Tension Command Tension Ref % I
t means the maximum tension command value is ±10 where the inpu Dancer Position
Command Dancer Ref % It means dancer command value is ±100% where the input is ±10V
Taper Command Taper Ref % It means taper command value is ±100% where the input is ±10V
Tension Feedback Tension F/B % It means the amount of tension feedback is
±100% where the input is ±10V
Diameter Input Diameter % In case of using the diameter sensor, it means the diameter is ±100% where the input is ±10V Diameter Initialization Diam Preset %
In case of using diameter initialization by analog input, it means the diameter is ±100% where the input is ±10V
AIO_74 AO1 Define
Final Line Speed
Command Line Speed % Outputs the final line speed command that is the sum of line speed command and PID controller
output Final Tension
Command Tension Out % Outputs the final tension command after computing Taper, Boost, and Stall Diameter Diameter % Outputs the current diameter
7-15
7. WEB Control
7.5.4 Function Group (FUN_[][])
If CON_02 Application of Control (CON) Group is selected as “WEB Control”, you may select the following function in addition. For further detail, please refer to the explanation on WEB group function.
Functio nCode
Loader Display
Definition of Function
Unit Explanation of Function Name Setting Range
FUN_02 Spd Ref Sel Speed Setting Method
Line SPD Ref It is set when conducting line speed command with analog input at the time of Web control.
Line SPD Opt It is set when conducting line speed command with communication at the time of Web control..
Note) In case of setting FUN_02 Spd Ref Sel to the other value than “Line SPD Ref” or “Line SPD Opt”, you cannot make exact Web control. Therefore, please set “Line SPD Ref” or “Line SPD Opt” without fail.
7.5.5 Control Group (CON_[][])
CON_02 Application allows you the setting of general vector control mode and WEB control mode. In case of conducting Web control, please set “WEB Control” without fail. Only when setting “WEB Control”, you can confirm all the function and Web group necessary for WEB control in the keypad.
Functio nCode
Loader Display
Definition of Function
Unit Explanation of Function Name Setting Range
CON_02 Application application control General Vect It is set when using the general vector function.
WEB Control It is set when using Web control function.
7. WEB Control
7.6 Function Code of WEB Application Group (WEB_[][])
Code
No. Comm.
Addr Code Name LCD DISPLAY Setting Data Adjustment
During Run PAGE Range Unit Default
WEB_00 - Selection of Function Code Jump Code 1 ~ 59 Yes
WEB_01 - Diameter Size Display Diameter 5.0 ~ 100.0 % 10.0 No 7-18
WEB_02 - Selected Initial Diameter Current Core (Display Only)
0 (Diam Preset 1) 1 (Diam Preset 2) 2 (Diam Preset 3) 3 (Diam Preset 4) 4 (Analog) 5 (Option)
0 (Diam Preset 1) No 7-19
WEB_03 7C03 Setting of the Type of
Diameter Initialization DiaPresetSrc
0 (Keypad) 1 (Analog) 2 (Option)
0 (Keypad) No 7-19
WEB_04 7C04 1st Diameter Initial Value Diam Preset 1 WEB_10 ~ 100.0 % 10.0 No 7-20 WEB_05 7C05 2nd Diameter Initial Value Diam Preset 2 WEB_10 ~ 100.0 % 15.0 No 7-20 WEB_06 7C06 3rd Diameter Initial Value Diam Preset 3 WEB_10 ~ 100.0 % 20.0 No 7-20 WEB_07 7C07 4th Diameter Initial Value Diam Preset 4 WEB_10 ~ 100.0 % 25.0 No 7-20 WEB_08 7C08
Motor Maximum Rotating
Speed with Min. Diameter MaxMotor SPD 75.0 ~ 3600.0 rpm 300.0 Yes 7-21 WEB_09 7C09 Minimum Effective Line
Speed MinLine SPD 0.0 ~ 100.0 % 5.0 No 7-21
WEB_10 7C0A Minimum Diameter Min Diameter 5.0 ~ 100.0 % 10.0 No 7-22
WEB_11 7C0B
Selection of Acceleration/Deceleration
Time Setting in case of WEB Control
AccDecWeb 0 (No) / 1 (Yes) 1 (Yes) No 7-22
WEB_12 7C0C Acceleration Time in case of
WEB Control Acc TimeWeb 0.00 ~ 6000.0 sec 0.50 Yes 7-22
WEB_13 7C0D deceleration Time in case of
WEB Control Dec TimeWeb 0.00 ~ 6000.0 sec 0.50 Yes 7-22
WEB_14 7C0E Setting of the Type of
Diameter Computation Diameter Src 0 (Internal)
1 (Exernal) 0 (Internal) No 7-22
WEB_15 7C0F Time Constant of Diameter
Computation LPF Diameter LPF 0.01 ~ 300.00 sec 5.00 Yes 7-23
WEB_16 7C10 False Core Value False Core 0.0 ~ 50.0 % 5.0 Yes 7-23
WEB_17 7C11 Rewind/Unwind Setting Re/Un Wind 0 (Rewind)
1 (Unwind) 0 (Rewind) No 7-23
WEB_18 7C12 Overwind /Underwind
Setting O/U Wind 0 (Overwind)
1 (Underwind) 0 (Overwind) No 7-24
WEB_19 7C13 Tension Reference Input
Setting TensionInput -100.0 ~ 100.0 % 0.0 Yes 7-26
WEB_20 7C14 Taper Type Setting Taper Type
0 (None) 1 (Hyperbolic) 2 (Linear)
0 (None) No 7-26
WEB_21 7C15 Taper Input Value Setting Taper Input -100.0 ~ 100.0 % 0.0 No 7-26 WEB_22 7C16 Boost Type Setting Boost Type 0 (Proportional)
1 (Fixed) 0 (Proportional) No 7-27
WEB_23 7C17 Boost Input Value Setting Boost Input 0.0 ~ 50.0 % 0.0 No 7-27 WEB_24 7C18 Stall Type Setting Stall Type 0 (Proportional)
1 (Fixed) 0 (Proportional) No 7-28
WEB_25 7C19 Stall Input Value Setting Stall Input 0.0 ~ 50.0 % 0.0 No 7-28 WEB_26 7C1A
Ramp Time Setting of Tension Reference Input Value
Tension Ramp 0.00 ~ 600.00 sec 5.00 Yes 7-29
WEB_27 7C1B Tension Control Enable
Setting Tension Enb 0 (Disable)
1 (Enable) 1 (Enable) No 7-30
WEB_28 7C1C PID Reference Type Setting PIDRef Sel 0 (Dancer Pos)
1 (Taper Out) 1 (Taper Out) No 7-30 WEB_29 7C1D Dancer Reference position
Setting Dancer Pos -100.0 ~ 100.0 % 0.0 Yes 7-31
WEB_30 7C1E Process PID P1 Gain
Setting ProcPID Kp1 0.0 ~ 999.9 % 10.0 Yes 7-31
WEB_31 7C1F Process PID P2 Gain
Setting ProcPID Kp2 0.0 ~ 999.9 % 0.0 Yes 7-31
WEB_32 7C20 Process PID I1 Gain
Setting ProcPID Ki1 0.0 ~ 100.0 sec 5.0 Yes 7-31
WEB_33 7C21 Process PID I2 Gain
Setting ProcPID Ki2 0.0 ~ 100.0 sec 0.0 Yes 7-31
WEB_34 7C22 PID Gain Ramp Time
Setting PIDGain RAMP 0.1 ~ 100.0 sec 1.0 Yes 7-32
7-17
7. WEB Control
Code
No. Comm.
Addr Code Name LCD DISPLAY Setting Data Adjustment
During Run PAGE Range Unit Default
WEB_35 7C23 Process PID P Gain Profiler
Type Setting P Profiler
0 (Linear) 1 (Square) 2 (Cubed) 3 (Quadratic)
0 (Linear) No 7-32
WEB_36 7C24 Process PID P Gain Profiler
Gain Setting P Apt Gain -1.00 ~ 10.00 0.00 No 7-32
WEB_37 7C25 Process PID D Gain Setting ProcPID Kd 0.0 ~ 100.0 % 0.0 Yes 7-33 WEB_38 7C26 Process PID D Gain LPF ProcKd LPF 0.0 ~ 100.0 sec 2.0 Yes 7-33 WEB_39 7C27 Process PID Positive Limit Proc Pos Lmt -100.0 ~ 100.0 % 100.0 Yes 7-33 WEB_40 7C28 Process PID Negative Limit Proc Neg Lmt -100.0 ~ 100.0 % -100.0 Yes 7-33 WEB_41 7C29 Process PID Output LPF
Time Constant PID Out LPF 0.00 ~ 100.00 sec 1.00 Yes 7-34
WEB_42 7C2A Rewind-Use Process PID
Output Gain PIDOGainRe -250.0 ~ 250.0 % 0.0 Yes 7-34
WEB_43 7C2B Unwind-Use Process PID
Output Gain PIDOGainUn -250.0 ~ 250.0 % 0.0 Yes 7-34
WEB_44 7C2C PID Controller Type Setting PID Type 0 (Proportional)
1 (Fixed) 0 (Proportional) No 7-34
WEB_45 7C2D Minimum PID Controller
Output Setting Min FPID 0.0 ~ 50.0 % 10.0 No 7-34
WEB_46 7C2E Time of Maintenance of PID
Controller After Break PIDHoldTime 0.0 ~ 100.0 sec 5.0 Yes 7-36 WEB_47 7C2F Process PID Feedback Type
Setting PID F/B Src 0 (Analog)
1 (Option) 0 (Analog) No 7-36
WEB_48 7C30 WEB Break Detection
Function Setting WB Enable 0 (No) / 1 (Yes) 0 (No) Yes 7-38
WEB_49 7C31 Setting of Time Delayed until Web Break Detection after
Inverter Operation INV WB Delay 0.1 ~ 600.0 sec 1.0 Yes 7-38
WEB_50 7C32 Time
Delayed for WEB Break
Detection WB Delay 0.1 ~ 600.0 sec 1.0 Yes 7-38
WEB_51 7C33 WEB Break Detection Level WB Level 0.0 ~ 100.0 % 0.0 Yes 7-38 WEB_52 7C34 Up to Speed Judgment
Setting UTS Enable 0 (No) / 1 (Yes) 0 (No) Yes 7-39
WEB_53 7C35 Up to Speed Level UTS Level 0.0 ~ 100.0 % 0.0 Yes 7-39
WEB_54 7C36 Quick Stop time Setting Quick Stop 0.0 ~ 100.0 sec 1.0 Yes 7-39
WEB_55 7C37 Jog Speed Setting JogSpd Web 0.0 ~ 100.0 % 10.0 Yes 7-40
WEB_56 7C38 Jog
Acceleration/Deceleration
Time Setting Select JogTime Sel 0 (No) / 1 (Yes) 1 (Yes) No 7-40 WEB_57 7C39 Jog Acceleration Time
Setting JogAcc Time 0.00 ~ 6000.0 sec 5.00 Yes 7-40
WEB_58 7C3A Jog deceleration time Setting JogDec Time 0.00 ~ 6000.0 sec 5.00 Yes 7-40 WEB_59 7C3B Splicing Level Setting Splice Level 0.0 ~ 100.0 % 0.0 Yes 7-41
7. WEB Control
7.7 WEB Group Function 7.71 Jump code(WEB_00)
You may directly jump into the code desired using WEB_00.
(Example) If you want to move to WEB_03;
Press [PROG] key, and then press [SHIFT/ESC] / [▲UP] / [▼DOWN] keys to set 3.
Then you may move to the following mode by pressing [ENT] key.
After jump movement, you can move to the other code using [▲UP] / [▼DOWN] key.
7.7.2 Diameter Display