Errors related to the component gases

Một phần của tài liệu Tiêu chuẩn iso 06142 2001 (Trang 36 - 42)

Sources of error related to the component gases are as follows:

ắ residual gas in cylinder;

ắ leakage resulting from:

ắ leakage of air into the cylinder after evacuation;

ắ leakage of gas from the cylinder valve during filling;

ắ leakage of gas from the cylinder after filling;

ắ escape of gas from cylinder into transport lines;

ắ gas remaining in transfer system when mass loss method is used;

ắ adsorption/reaction of components on internal cylinder surface;

ắ reaction between components;

ắ impurities in the parent gases used;

ắ insufficient homogenization;

ắ uncertainty of molecular mass.

Copyright International Organization for Standardization Provided by IHS under license with ISO

--`,,```,,,,````-`-`,,`,,`,`,,`---

© ISO 2001 – All rights reserved 33

Annex F (informative)

Estimation of corrections and correction uncertainty

Often uncertainty contributions are estimated in terms of error bounds. If such estimates are available, they can be used to derive

ắ corrections, to be applied to the target quantity under consideration, and

ắ correction uncertainties, to be included in the list of contributions to uncertainty,

according to the type B approach specified in theGuide to the expression of uncertainty in measurement[17]. In the following, the cases of bounds for relative errors and for absolute errors are considered separately.

a) The source of error under consideration is estimated to contribute a relative error betweenAminandAmax. Thus the effect due to the source of error is described by a numerical factor fsomewhere between fmin=+Aminand fmax= 1+Amax. Most oftenAmin<0,Amax>0 and |Amin| = |Amax|, but other cases also occur in practice.

The recommended procedure, based on a rectangular distribution, is to use the average factor given by:

min max

av 1

f = +A +2A (F.1)

as a correction factor, and to include the relative standard uncertainty on this correction, given by:

max min

rel 2 3

u =A -A (F.2)

in the list of contributions to uncertainty of the quantity under consideration.

If the error bounds are symmetric, Amin =-A, Amax = A with a positive relative error A, the correction factor is unity, i.e. no correction is necessary. Nevertheless, this factor unity comes with an uncertainty, urel=A 3 which has to be taken into account.

b) The source of error under consideration is estimated to contribute an absolute error betweeneminandemax. As in a), most oftenemin<0,emax>0 and |emin| = |emax|, but other cases also occur in practice.

The recommended procedure, based on rectangular distribution, is to use the average, given by:

min max

av 2

e e

e = + (F.3)

as an additive correction, and to include the (absolute) standard uncertainty for this correction, given by:

max min

2 3

e e

u= - (F.4)

to the list of contributions to uncertainty of the quantity under consideration.

Copyright International Organization for Standardization Provided by IHS under license with ISO

--`,,```,,,,````-`-`,,`,,`,`,,`---

34 © ISO 2001 – All rights reserved

If the error bounds are symmetric, emin = -e, emax = e with a positive error e, the correction is zero, i.e. no correction is necessary. Nevertheless this term zero comes with an uncertainty, u=e 3 which has to be taken into account.

Often the available error bounds do not directly refer to the target quantity, x, under consideration, but to another quantity, y, having an effect on x. In this case, the calculated correction and correction uncertainty have to be transferred to the quantity targeted by using rigorous or approximate sensitivity coefficients,ảx/ảyorDx/Dy.

Copyright International Organization for Standardization Provided by IHS under license with ISO

--`,,```,,,,````-`-`,,`,,`,`,,`---

© ISO 2001 – All rights reserved 35

Annex G (informative)

Computer implementation of recommended methods

A validated computer program implementing the recommended methods of calculating mixture composition and uncertainties as described in this International Standard is available from the following address:

NEN

Secretariat of ISO/TC 158 P.O. Box 5059

2600 GB Delft The Netherlands

Tel.+31 15 2690330

fax.+31 15 2690190

This program will normally be supplied on a 3,5-inch double-sided high density diskette, but other formats are possible. A specification and the price per copy is available upon request.

The program has been written for use with IBM-compatible personal computers and the MS-Windows 95 operating system.

The program consists of the following:

ắ “purity table”, for input and editing of purity tables of parent gases containing a fixed number of gaseous components;

ắ “mixture data”, for input and editing of weighing results and accompanying uncertainties.

Calculation of the mixture composition is made in accordance with the method described in this International Standard. Resulting purity tables can be printed on a laser or inkjet printer.

The program has been validated by a large series of tests using real data sets and has been extensively tested and validated by experts of ISO/TC 158.

To a large extent, the program is self-explanatory. A number of help files are available within the program.

However, users are strongly recommended to study this International Standard before working with the program, and to refer to the description for all information about installation, input/output file formats, and usage of the program modules. The description is contained in a read-me file on the program diskette.

NOTE Although the program and the associated test data files will be made available in good faith, there is no implied warranty for their use in contractual or other commercial applications, and no guarantee that they are all error-free. However, they have undergone testing and contain no known errors at the time of going to press.

Copyright International Organization for Standardization Provided by IHS under license with ISO

--`,,```,,,,````-`-`,,`,,`,`,,`---

36 © ISO 2001 – All rights reserved

Bibliography

List on vapour pressures at given temperature for condensable components

[1] API Research project 44, Selected Values of Properties of Hydrocarbons. Government Printing Office, Washington DC, 1947.

[2] API, Technical Data Book. New York, 1970.

[3] Encyclopédie des Gaz (Gas Encyclopaedia). L’Air Liquide, Elsevier Science Publ., Amsterdam, ISBN 0-444-41492-4.

[4] GALLANTR.W. and YAWSC.L. Physical Properties of Hydrocarbons. 4 Volumes, Gulf Publishing Company, Houston, ISBN 0-88415-067-4, 0-88415-175-1, 0-88415-176-X, 0-88415-272-3.

[5] BAUMER D. and RIEDEL E. Gase-Handbuch. (Messer GRIESHEIM, ed.) C. Adelmann Publ., Frankfurt, Germany.

[6] HILSENRATH J. et al. Tables of Thermodynamic and Transport Properties, Pergamon Press, New York, 1960.

[7] CRC Handbook of Chemistry and Physics. (LIDED.R., ed.). CRC Press, Inc., Florida, ISBN 0-8493-0475-X.

[8] LANDOLT- BệRNSTEIN. Vol II, Springer Verlag, 6th ed.

[9] REIDR.C., PRAUSNITZ J.M. and SHERWOOD T.K. The properties of gases and liquids. Mc Graw-Hill, 1977, ISBN 0-07-051790-8.

[10] TRC Thermodynamic Tables. Thermodynamics Research Center, Texas A & M University.

[11] YAWS C.L. Handbook of Vapor Pressure, 3 Volumes, C1 to C28 Compounds. Gulf Publishing Company, Houston, ISBN 0-88415-189-1, 0-88415-190-5, 0-88415-191-3.

Bibliographic list

[12] GIACOMO P. Equation for the determination of the density of moist air (1981). Metrologia, 18, 1982, pp. 33-40.

[13] DAVIS R.S. Equation for the determination of the density of moist air (1981,91). Metrologia, 29, 1992, pp. 67-70.

[14] SCHWARTZR. Guide to mass determination with high accuracy. PTB-Bericht PTB-MA-40, April 1995, ISBN 3-89429-635-6.

[15] GLÄSERM. Response of apparent mass to thermal gradients. Metrologia, 27, 1990, pp. 95-100.

Informative references

[16] ISO 141674), Gas analysis — General quality assurance aspects in the use and preparation of reference gas mixtures — Guidelines.

[17] Guide to the expression of uncertainty in measurement (GUM). BIPM, IEC, IFCC, ISO, IUPAC, IUPAP, OIML, 1st ed., corrected and reprinted in 1995.

[18] DIN 51896-1, Gas analysis — Quantities of composition, compressibility factor — Basis.

4) In preparation.

Copyright International Organization for Standardization Provided by IHS under license with ISO

--`,,```,,,,````-`-`,,`,,`,`,,`---

© ISO 2001 – All rights reserved 37 [19] ISO 6145 (all parts), Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric

methods