Primitives exchanged between AP-Context and FSPMM1

Một phần của tài liệu Iec 61158 6 3 2014 (Trang 136 - 141)

Table 46 shows the service primitives including their associated parameters issued by the AP- Context and received by the FSPMM1.

Table 46 – Primitives issued by AP-Context to FSPMM1

Primitive name Source Associated

parameters Functions

Init DP master Cl1.req AP-Context Bus Para Refer to FAL Service Definition in IEC 61158-5-3 and in IEC 61158-3-3 Reset DP master Cl1.req AP-Context (none) Refer to FAL Service Definition in

IEC 61158-5-3 Load ARL DP master Cl1.req AP-Context Alarm Max,

List of ARL Entries Get ARL DP master Cl1.req AP-Context (none)

Load CRL DP master Cl1.req AP-Context Update,

List of CRL Entries Get CRL DP master Cl1.req AP-Context (none)

CRL Slave Activate.req AP-Context Activate CRL New Prm.req AP-Context New Prm CRL New Prm Data.req AP-Context Prm Data Abort DP master Cl1.req AP-Context AREP Mark DP master Cl1.req AP-Context AREP Set Mode DP master Cl1.req AP-Context AREP,

USIF State Load Bus Par DP master

Cl1.req AP-Context Bus Para

Delete SC DP master Cl1.req AP-Context Address Read Value DP master Cl1.req AP-Context Variable Get Slave Diag.req AP-Context AREP,

CREP Set Output.req AP-Context AREP,

CREP, Slot Number, Output Data, Final

Get Input.req AP-Context AREP,

CREP, Slot Number Global Control.req AP-Context AREP,

Sync Command, Freeze Command, Group Select

Read.req AP-Context AREP,

Slot Number, Index, Length

Write.req AP-Context AREP,

Slot Number, Index, Length, Data

Primitive name Source Associated

parameters Functions

Alarm Ack.req(+) AP-Context AREP, Slot Number, Alarm Type, Seq Nr Get Master Diag.rsp(+) AP-Context AREP,

Diagnosis Data Get Master Diag.rsp(-) AP-Context AREP,

Status Start Seq.rsp(+) AP-Context AREP,

Max Len Data Unit Start Seq.rsp(-) AP-Context AREP,

Status Download.rsp(+) AP-Context AREP Download.rsp(-) AP-Context AREP,

Status

Upload.rsp(+) AP-Context AREP,

Data

Upload.rsp(-) AP-Context AREP,

Status End Seq.rsp(+) AP-Context AREP End Seq.rsp(-) AP-Context AREP,

Status Act Param.rsp(+) AP-Context AREP Act Param.rsp(-) AP-Context AREP,

Status

Set Time.req AP-Context AREP,

Time Value Local Time Diff Summertime Accuracy Synchronisation Active

Announcement Hour Initiate Load.req AP-Context AREP,

Slot Number, LR Index, Load Type, Load Image Size, Intersegment Request, Timeout User_Specific Pull Segment.req AP-Context AREP,

Slot Number, LR Index, Segment Length Push Segment.req AP-Context AREP,

Slot Number LR Index, Segment Length Segment Number, More Follows, Data

Terminate Load.req AP-Context AREP Slot Number LR Index

Start.req AP-Context AREP

Slot Number FI Index

Execution Argument

Primitive name Source Associated

parameters Functions

Stop.req AP-Context AREP

Slot Number FI Index

Resume.req AP-Context AREP

Slot Number FI Index

Execution Argument

Reset.req AP-Context AREP

Slot Number FI Index

Call.req FSPMS AREP

Slot Number Entity Number FI Index

Execution Argument

Get_FI_State.req FSPMS AREP

Slot Number FI Index

Table 47 shows the service primitives including their associated parameters issued by the FSPMM1 and received by the AP-Context.

Table 47 – Primitives issued by FSPMM1 to AP-Context

Primitive name Source Associated parameters Functions

Init DP master Cl1.cnf FSPMM1 (none) Refer to FAL Service Definition in IEC 61158-5-3

Reset DP master Cl1.cnf FSPMM1 (none) Load ARL DP master

Cl1.cnf(+) FSPMM1 (none)

Load ARL DP master Cl1.cnf(-) FSPMM1 Status Get ARL DP master Cl1.cnf(+) FSPMM1 Alarm Max,

List of ARL Entries Get ARL DP master Cl1.cnf(-) FSPMM1 Status

Load CRL DP master

Cl1.cnf(+) FSPMM1 (none)

Load CRL DP master Cl1.cnf(-) FSPMM1 Status

Get CRL DP master Cl1.cnf(+) FSPMM1 List of CRL Entries Get CRL DP master Cl1.cnf(-) FSPMM1 Status

CRL Slave Activate.cnf(+) FSPMM1

CRL Slave Activate.cnf(-) FSPMM1 Status CRL New Prm.cnf(+) FSPMM1

CRL New Prm.cnf(-) FSPMM1 Status CRL New Prm Data.cnf(+) FSPMM1

CRL New Prm Data.cnf(-) FSPMM1 Status Mark DP master Cl1.cnf(+) FSPMM1 AREP,

Dia Mark DP master Cl1.cnf(-) FSPMM1 AREP,

Status Set Mode DP master Cl1.cnf(+) FSPMM1 AREP,

Bus Accessible Set Mode DP master Cl1.cnf(-) FSPMM1 AREP,

Bus Accessible

Primitive name Source Associated parameters Functions Load Bus Par DP master

Cl1.cnf FSPMM1 Status

Delete SC DP master Cl1.cnf FSPMM1 Status Read Value DP master Cl1.cnf FSPMM1 Value, Status Get Slave Diag.cnf(+) FSPMM1 AREP,

CREP, Diag Data Get Slave Diag.cnf(-) FSPMM1 AREP,

CREP Set Output.cnf(+) FSPMM1 AREP,

CREP, Slot Number Set Output.cnf(-) FSPMM1 AREP,

CREP, Slot Number, Status

Get Input.cnf(+) FSPMM1 AREP,

CREP, Slot Number, Input Data

Get Input.cnf(-) FSPMM1 AREP,

CREP, Slot Number, Status Global Control.cnf(+) FSPMM1 AREP Global Control.cnf(-) FSPMM1 AREP,

Status

Read.cnf(+) FSPMM1 AREP,

Length, Data

Read.cnf(-) FSPMM1 AREP,

Error Decode, Error Code 1 Error Code 2

Write.cnf(+) FSPMM1 AREP,

Length

Write.cnf(-) FSPMM1 AREP,

Error Decode, Error Code 1 Error Code 2

Alarm Ack.cnf(+) FSPMM1 AREP,

Slot Number, Alarm Type, Seq Nr

Alarm Ack.cnf(-) FSPMM1 AREP

Slot Number, Alarm Type, Seq Nr Get Master Diag.ind FSPMM1 AREP,

Mdiag Identifier

Start Seq.ind FSPMM1 AREP,

Area Code, Timeout

Download.ind FSPMM1 AREP,

Area Code, Add Offset, Data

Primitive name Source Associated parameters Functions

Upload.ind FSPMM1 AREP,

Area Code, Add Offset, Data Len

End Seq.ind FSPMM1 AREP

Act Param.ind FSPMM1 AREP,

Area Code, Activate Act Para Brct.ind FSPMM1 AREP,

Area Code New Slave Diag.ind FSPMM1 AREP,

CREP

New Input.ind FSPMM1 AREP

Alarm Notification.ind FSPMM1 AREP, Slot Number, Alarm Type, Seq Nr, Add Ack, Alarm Specifier, Alarm Data DP master Cl1 Mode

Changed.ind FSPMM1 AREP,

USIF State

DP master Cl1 Event.ind Event,

Add Info DP master Cl1 Started.ind FSPMM1 AREP DP master Cl1 Stopped.ind FSPMM1 AREP

Abort.ind FSPMM1 AREP

DP master Cl1 Reject.ind FSPMM1 AREP, Reason DP master Cl1 Fault.ind FSPMM1 ( none )

SYNCH.ind FSPMM1 AREP

SYNCH Delayed.ind FSPMM1 AREP, TSH

DX Finished.ind FSPMM1 AREP

Set Time.ind FSPMM1 AREP,

Time Value, Local Time Diff, Summertime, Accuracy,

Synchronisation Active, Announcement Hour

Set Time.cnf FSPMM1 AREP,

Status Sync Interval Violation.ind FSPMM1 AREP Initiate Load.cnf(+) FSPMM1 AREP,

Actual LR Size, Max Response Delay, Max Segment Length User Specific Initiate Load.cnf(-) FSPMM1 AREP,

Error Code Pull Segment.cnf(+) FSPMM1 AREP,

Segment Length, Segment Number, More Follows, Data

Pull Segment.cnf(-) FSPMM1 AREP, Error Code

Primitive name Source Associated parameters Functions Push Segment.cnf(+) FSPMM1 AREP

Push Segment.cnf(-) FSPMM1 AREP, Error Code Terminate Load.cnf(+) FSPMM1 AREP Terminate Load.cnf(-) FSPMM1 AREP,

Error Code

Start.cnf(+) FSPMM1 AREP

Start.cnf(-) FSPMM1 AREP

Error Code

Stop.cnf(+) FSPMM1 AREP

Stop.cnf(-) FSPMM1 AREP

Error Code

Resume.cnf(+) FSPMM1 AREP

Resume.cnf(-) FSPMM1 AREP

Error Code

Reset.cnf(+) FSPMM1 AREP

Reset.cnf(-) FSPMM1 AREP

Error Code

Call.cnf(+) FSPMM1 AREP

Result Argument

Call.cnf(-) FSPMM1 AREP

Error Code Get FI State.cnf(+) FSPMM1 AREP

FI State Get FI State.cnf(-) FSPMM1 AREP

Error Code

Một phần của tài liệu Iec 61158 6 3 2014 (Trang 136 - 141)

Tải bản đầy đủ (PDF)

(744 trang)