... Trang 1Chapter 52Heating and Air-Conditioning Trang 2• The interior fan circulates air within compartment when the vehicle is stopped Trang 4Automotive Heating Systems• Works with ... blower runs but no air comes out, inspect airflow control or blend door • Blend and vent selection controls can be cable, vacuum, or electrically controlled Trang 11Theory of Air-Conditioning• Heat ... temperature of heater inlet and outlet hoses • Check heater control valve for sticking open/closed and the valve’s controls Trang 8Blower Motor Service• Check power and Trang 9Heater and Defroster Duct
Ngày tải lên: 01/02/2021, 11:09
... Trang 1Chapter 53Air-Conditioning Diagnosis and Service Trang 2Service Precautions• Wipe away any oil or dirt before disconnecting a connection • Keep tools clean and dry • Refrigerant oil ... Purge each gauge set hose to remove air trapped in the hoses and gauges Trang 14Testing Procedures• Run engine between 1500 and 2000 rpm • Close all vehicle windows and doors • Set A/C to maximum ... Check operation at full heat and full cold • Pay attention to smells and noises • Inspect the compressor drive belt • Look for a film of oil leakage • Check for condenser airflow restrictions Trang
Ngày tải lên: 01/02/2021, 11:09
Heating, ventilation, and air conditioning
... OF HEATING, VENTILATION, AND AIR CONDITIONING Air, Return (Recirculated). Air that leaves a conditioned spaced and is returned to the air conditioning equipment for treatment Air, Saturated. Air ... temper-ature.Air Conditioning, Comfort. Use of air conditioning solely for human comfort, as compared with conditioning for industrial processes or manufacturing Air Conditioning, Industrial. Use of air conditioning ... (100% humidity),with the air and water vapor at the same temperature Air, Standard. Air at 70⬚F (21⬚C) and standard atmospheric pressure [29.92 in(101.3 kPa) of mercury] and weighing about 0.075
Ngày tải lên: 30/04/2018, 19:28
SUBCOURSE OD1750EDITION AREFRIGERATION AND AIR CONDITIONING IV potx
... REFRIGERATION AND AIR CONDITIONING IV (EQUIPMENT COOLING) EDITION A REFRIGERATION AND AIR CONDITIONING IV (EQUIPMENT COOLING) Subcourse OD1750 Edition A United States Army Combined Arms Support Command ... direct expansion (D/X), and (3) reheat We will discuss the application of these coils, their use and control, and the valves and dampers which control the flow of water and air D/X Coil In equipment ... refrigeration and air conditioning The scope of this subcourse takes in unit components of the absorption system, including their functions and maintenance; water treatment methods and their relationship
Ngày tải lên: 05/03/2014, 19:20
Refrigeration and Air Conditioning 3 E Part 6 pdf
... compressor and drive only, forsite connection to a remote air-cooled condenser As such, they arecorrectly termed compressor units Compressor and condensingunits will be site connected to evaporators, and ... system and will be factory tested in the complete state There are four basic types: Trang 15158 Refrigeration and Air-ConditioningTable 13.1 Capacity, in kW, of water-cooled Air cooling, air cooled ... Refrigeration and Air-ConditioningFigure 13.2 Packaged water chillers (a) Air cooled (b) Water cooled(Courtesy of APV Baker Ltd) From table, rating at – 20 to + 25°C is 18.6 kW Since compressor and condensing
Ngày tải lên: 12/08/2014, 00:20
Refrigeration and Air Conditioning 3 E Part 7 pps
... slaughter and dressing Cooling of meat-handling rooms such as butcheries Chilled water and brine for cooling poultry Chill storage of edible meats and offal Chilling of brine and pickling vats Meat and ... structuralfloor slab and then protected within a 50 mm thickness of cementand sand to give a suitable surface on which the floor vapourbarrier can be laid The heating is thermostatically controlled,and it ... blocks, commonly 50, 75 and 100 mm thick 2 Expanded polystyrene The plastic is formed into beads containing an expanding agent When placed in a mould and heated theyswell and stick together The
Ngày tải lên: 12/08/2014, 00:20
Refrigeration and Air Conditioning 3 E Part 8 pot
... inside and outside air, and the usage of the doors The latter is affected by the existence of airlocks and curtains [49] Standard textbooks give data on which to base an estimate, and this ... Suction from air-conditioning Suction from chill display and storage Compressors Suction from frozen display and storage Compressors Compressors Refrigerated transport, handling and distribution ... vegetables and flowers need to be protected from freezing, and produce will usually be in insulated containers. A feature of this traffic is the prompt and speedy handling at the airports. Coldrooms
Ngày tải lên: 12/08/2014, 00:20
Refrigeration and Air Conditioning 3 E Part 9 doc
... 24.1 Sensible heating of air5 0 ulb temper ature ( 68 × 7.35 ~ 500 kW Air entering the conditioning plant will probably be a mixture ofreturn air from the conditioned space and outside air Since ... Refrigeration and Air-Conditioningwill take place and the water will draw its latent heat from the air,reducing the sensible heat and therefore the dry bulb temperature of the air (Figure 24.4) ... every 1 kg air What is the water temperature rise? Trang 15248 Refrigeration and Air-ConditioningFigure 24.7 Air washer with chilled water Figure 24.8 Chilled water spray Enthalpy of air before
Ngày tải lên: 12/08/2014, 00:20
Refrigeration and Air Conditioning 3 E Part 10 pps
... fresh air supply or stale air extract) or by accident (infiltration through window and door gaps, and dooropenings) Since a building for human occupation must have somefresh air supply and some ... and ASHRAE 16-83 Total pressures required for air-conditioning systems and apparatusare rarely in excess of 2 kPa, and so can be obtained with dynamicair-moving machinery rather than positive-displacement ... to the entering airand the resulting centrifugal force is converted to pressure andvelocity in a suitable outlet scroll Air leaving the tips of the bladeswill have both radial and tangential velocities,
Ngày tải lên: 12/08/2014, 00:20
Refrigeration and Air Conditioning 3 E Part 11 pptx
... of dust and fluff in the air is inlarge particles and so is fairly easy to trap Filters for general air-conditioning duty comprise a felt of glass or other fibres, used in adry state and termed ... saturation, and has an internal load of 14 kW sensible and1.5 kW latent heat gain The inlet grille system is suitable for aninlet air temperature of 12°C What are the inlet air conditions andthe mass air ... acceptable to a majority of the occupants Such standards of air-conditioning are generally termed comfort cooling. 28.3 Central station system All air The centralization of all plant away from the conditioned
Ngày tải lên: 12/08/2014, 00:20
Refrigeration and Air Conditioning 3 E Part 12 pps
... control diagram for small air-conditioningsystem 31.7 Commissioning of control systems The setting up, testing and recording of all control functions of arefrigeration or air-conditioning system must ... ingoing and outgoing temperatures 3 The required limits of control 4 A realistic ambient condition for condenser water or air, andfor fresh air supply – 10°C in a coldroom measuring X × Y × Z and ... fluid flows, temperatures, and pump, fan and filter pressures 3 Refrigerant pressures and temperatures at expansion valve inlet,evaporator outlet, and compressor suction and discharge 4 Settings
Ngày tải lên: 12/08/2014, 00:20
Refrigeration and Air Conditioning 3 E Part 13 ppsx
... fresh air for air-conditioning, if required in cold weather 2 Provide mid-season heating from condenser heat or heat pump(reverse-cycle) operation 3 Run plant at night on low-cost electricity and ... factor is multiplied by the ∆T between the entering air and the refrigerant. Example 35.5 An air-cooling evaporator has a mass air flow of 8.4kg/s and a published ‘rating’ of 3.8 kW/K What will be ... entering at 24°C and leaving at 18°C, with the refrigerantevaporating at 11°C Estimate the cooling capacity at 95, 90 and85% mass air flow Design mass air flow 25 ° C 35 ° C 30 ° C Air onto condenser
Ngày tải lên: 12/08/2014, 00:20
Refrigeration and Air Conditioning Equipment Cooling Episode 2 docx
... Disconnect the valve and plug the tube ends Remove the screen and clean it with a recommended cleaning solvent After the screen is clean and dry, reinstall it in the valve and connect the valve ... compressor, and start the unit Figure 20 shows two different types of strainers, basket and disc, and their location in the compressor motor 10 Purging noncondensable gases Noncondensable gases (air) ... indicated loss of capacity and the discharge valves check properly, you must remove the head and valve plate and check the valves physically 17 Disassembly, inspection, and reassembly of valve plates
Ngày tải lên: 12/08/2014, 16:21
Refrigeration and Air Conditioning Equipment Cooling Episode 3 pdf
... Check the standpipe for water seal circulation before starting the pumps (8) Start the chilled water pump and open the valves to insure circulation through the evaporator tubes and air-conditioning ... chilled water and condensing water circuits (2) Fill the condensing water circuit (3) Start the purge unit to remove all air and nitrogen from the machine (4) Fill the primary and secondary chilled ... F Explosion-proof controls and motor are installed for special applications Refer to the manufacturer's manual on the operation and maintenance of these controls and motors 12 Thermometers
Ngày tải lên: 12/08/2014, 16:21
Refrigeration and Air Conditioning Equipment Cooling Episode 8 doc
... cathode, and the potential (voltage) between the cathode and the plate Refer to figure 89, a diagram of a simple diode rectifier circuit 10 When an a.c source is connected to the plate and cathode ... that the center tap current is turned to ground and then through R and inductor L to the cathode (filament) of V1 The voltage appearing across X and Y is 700 volts a.c The center tap is at zero ... voltage is applied between the cathode and the grid, it will cause a change in grid bias and thus vary plate current This small a.c voltage between cathode and grid is called a signal 16 The large
Ngày tải lên: 12/08/2014, 16:21
Refrigeration and Air Conditioning Equipment Cooling Episode 10 ppsx
... Motor Servicing The only repairs that can be accomplished in the field are cleaning the potentiometer or limit switch contacts, repairing internal connecting wires, and replacing the internal ... the motor Disconnect the motor terminals (usually numbered 1, 2 and 3) and connect the transformer output leads to terminals 2 and 3 The motor should run clockwise, if it is not already at that ... definite characteristics-flexibility, sensitivity, simplicity, speed, and accuracy-that show to best advantage in an air-conditioning system where signals from several controllers must be coordinated
Ngày tải lên: 12/08/2014, 16:21
Refrigeration and Air Conditioning 3E Episode 4 pot
... evaporators Liquid cooling is mostly in shell-and-tube or shell-and-coil evaporators In the shell-and-tube type, the liquid is usually in the pipes andthe shell is some three-quarters full of the ... water-collection tank and a thin film of water runs overthe tubes Heat transfer is very high with a thin moving film ofliquid and, if any ice forms, it will be on the outside, free to expand,and it will ... forammonia Frost or condensed water will form on the fin surfaceand must be drained away To permit this, fins will be vertical andthe air flow horizontal, with a drain tray provided under The size
Ngày tải lên: 13/08/2014, 17:20
Refrigeration and air conditioning
... (WBT) Adiabatic saturation of air and adiabatic saturation temperature Heating and humidification Cooling and dehumidification Cooling and humidification Heating and dehumidification Sensible ... (SHF) Psychometric Processes in Air Conditioning Equipment Summer Air Conditioning-apparatus Dew Point (RSHF, GSHF, TSH, GTH, Minimum quantity of air (cmm) min ) Air refrigeration system Boot-strap ... p-v diagram for air refrigeration cycle? Trang 2537 Ans (a) 38 Match items in List I with those in List II and III and select the correct answer Superheating occurs in evaporator and it is involved
Ngày tải lên: 09/03/2016, 10:36
heating ventilation and air conditioning
... information on how to cut your air conditioning costs please refer to our dedicated Air Conditioning Advice pages Train staff on how to operate air conditioning units and heating controls Staff should ... instructions on individual units and ensure that remote controls have accessible and obvious storage spaces. Menu help 1 1Heating, ventilation and air conditioning Understanding and using controls An ... operating temperatures and how to set heating or cooling units correctly. Louvres (movable slats to guide the cool or heated air) are a feature on most air conditioning units and staff should be...
Ngày tải lên: 28/05/2014, 14:29
Handbook of HEATING, VENTILATION, and AIR CONDITIONING pdf
... Buildings 3.1 Central and Distributed Utilities 3.2 Economics and Costing of HVAC Systems 4. HVAC Equipment and Systems 4.1 Heating Systems 4.2 Air Conditioning Systems 4.3 Ventilation and Air Handling ... Technology, and his M.S. and Ph.D. degrees in engineering from the University of Colorado. He was employed by General Motors for several years in the design and testing of automotive heating and air conditioning ... Anthony F. Armor and Jan F. Kreider 3.2 Economics and Costing of HVAC Systems Ari Rabl Section 4 HVAC Equipment and Systems 4.1 Heating Systems Jan F. Kreider 4.2 Air Conditioning Systems ...
Ngày tải lên: 29/06/2014, 11:20