OUT IN DSX PERMANENT EQUIPMENT CABLE Network Element A DSX PERMANENT EQUIPMENT CABLE Network Element B Tx OUT X-OUT X-IN Rx INOUT IN Typical DSX Permanent Cross Connect Jumper Semi-LED
Trang 1as well as a convenient location for rearranging and restoring circuits Cross-connecting network elements
of a DSX is a simple, efficient way of organizing a facility's digital telecommunications equipment.
There are three basic areas in a DSX The wire termination area for terminating the signal (wire) from a network element The cross-connect area, used to connect the two DSXs that have terminated the signals from two digital network elements And finally, the heart of the DSX, the jack Each DSX jack provides an OUT, IN and MONITOR signal access point The OUT and IN switching jacks provide direct access to the network element's input and output signals These jacks provide a means of temporarily breaking the connection between DSX panels that are cross-connected together and allow access to the signals for test and patching operations A MONITOR jack with high impedance bridge networking is connected to the OUT jack for nonintrusive access to the output signal of each network element.
At 2.048 Mbps rate, DSX-1 panels connect network equipment such as office repeater bays, channel banks, multiplexers, digital switches, loop carriers, loop switches, radio, fiber optic systems, and other
2 Mbps equipment.
OUT IN
DSX
PERMANENT EQUIPMENT CABLE
Network Element A
DSX
PERMANENT EQUIPMENT CABLE
Network Element B
Tx OUT X-OUT
X-IN Rx INOUT
IN Typical DSX
Permanent Cross Connect Jumper
Semi-LED Tracer Wire
Test Box Test
Box
Monitoring and testing with traditional DSX requires finding and going to two locations for complete circuit testing.
It also requires access to both DSX sites and the time necessary to travel and setup test gear in two locations.
DSX Features and Benefits
• OUT/IN jacks – Fast and easy access to circuits for testing, monitoring and patching
• Bantam die-cast jacks – Guarantees quality and reliability over time
• Flashing LEDs available in a variety of colors – Provides easy circuit identification
• Multiple designs and configurations – Design optimized for each application
• Coax and 120 Ohm connections provide the flexibility to connect 75 Ohm equipment to
120 Ohm equipment
DSX Introduction
Traditional DSX Application
Trang 2Loaded 600 mm Skeleton Bay Empty 600 mm Skeleton Bay DSX 64-Termination Panel
PxPlus™PanelFlexDSX™Panel
2 Mbps DSX Front Cross-Connect Solutions
600 mm 2 Mbps DSX Product Family
Trang 3termination The jacks are individually removable and the backplane terminations are removable in groups
of four.
PxPlus™Panels
Ideal for applications requiring three-port jack access and true cost-deferment as equipment cables can be preterminated and jacks can be added as needed If the chassis has more than 60% of its terminations turned up within one year, the fixed, non-modular DSX 64 panels may be a better choice for a high growth environment.
DSX 64-Termination Panels
Ideal for applications where individual circuit modularity is not required This is a fixed, non-modular
64 termination panel with three-port jack access.
64 terminations/panel (Balun & twisted pair) X X X
Mounts in IBF-RSC021 skeleton bay X X X
(832) 2 Mbps terminations per bay X X X
In-service patching and circuit rearrangement X X X
Balun options (BNC & 1.6/5.6) X X X
Patching and monitoring capabilities X X X
Dual monitor (4 port jacks) X
Variety of backplanes and connector options X
to fit into 1 chassis
Trang 42 Mbps DSX Front Cross-Connect Solutions
ADC 600 mm Skeleton Bay for FlexDSX™, PxPlus™ and DSX64 Panels
The 600 mm skeleton bay is designed for FlexDSX, PxPlus and DSX 64-termination panels The assembled bay meets the standard ETSI 600 mm wide x 2.2 meter tall footprint for easy office planning Rack mounting will also accommodate standard 48.26 cm (19 inch) panels Fuse panels and all the
fully-necessary cable management are factory-installed in the bay, making ordering and installation fast and easy DSX panels are added in the field as needed OUT (Tx) and IN (Rx) cable ways for equipment terminations support the use of either 120 Ohm twisted pair or 75 Ohm coaxial cable The skeleton bay can be mounted
on either concrete or raised floor.
Front Jumper Rings(shown with panels installed)
600 mm
Extra rack space reserved formiscellaneous applications (such as cross aisle panels or monitorpanels) or for additional DSX panels(up to [832] 2 Mbps terminations)High-density supports up to (12)5.25-inch (13.34 cm) panels or (768)
2 Mbps terminations (120 Ohm or
75 Ohm) per baySingle part number simplifiesordering and installation
Rings and troughs – preprovisionedjumper management ensures existingwiring is not disturbed duringexpansion or maintenance
Cable tie down bars on the rear ofthe bay eliminate the need for fillerpanels and end guards
600 mm width aligns perfectly with raised floor tile dimensions and simplifies office engineering and planning
Panels mount over the rings –
no need for removal of rings during installation
All metric hardware allows easyreplacement for misplaced screws
Note: Bays come fully-loaded with cable troughs, cable rings, fuse panel and grounding kits
The bay holds up to nine 7-inch (17.78cm) high modules
Trang 5FlexDSX products also provide flexibility in deploying your resources The completely modular design allows you to deploy modules and chassis on an as-needed basis By creating a lineup of skeleton bays and filling the bays with chassis and modules only as needed, you can defer capital expenses until the equipment is ready to create a revenue stream.
In today's multinational, multiservice environment, FlexDSX products offer a variety of standard
terminations From wire-wrap to coax to RJ45 connectors, FlexDSX products offer the option to terminate
2 Mbps equipment from a single location.
OUT IN
FlexDSX
PERMANENT EQUIPMENT CABLE
Network Element A
FlexDSX
PERMANENT EQUIPMENT CABLE
Network Element B
Tx OUT X-OUT
LED Tracer Wire
Test Box
FlexDSX products provide the convenience and time-saving feature of testing and
monitoring the signal in both directions from one location
• Jumper rings and rear cable bars are installed on the skeleton bay – provides superior cable management
• OUT/IN equipment cable terminations on the backplane are modular in groups of four – allows for
multiple circuit count configurations (56, 64, 84)
• Works with twisted pair or coax cabling; choose wire-wrap, BNC or 1.6/5.6 interfaces – flexibility to meet a variety of needs
• Coax and 120 Ohm connections provide the flexibility to connect 75 Ohm equipment to
120 Ohm equipment
Trang 62 Mbps DSX Front Cross-Connect Solutions
FlexDSX™ Panels – Four-Port (Dual Monitor) Jack Access
FlexDSX panels are the only DSX panels in the industry that offer individual, removable jacks, removable OUT/IN equipment cable terminations, and four-port (bidirectional) test access capabilities The four-port jack system consists of OUT and IN jacks for direct access to the network element’s input and output signals, and DUAL MONITOR jacks for monitoring of the signal in both directions simultaneously at a single location Dual monitors are especially beneficial for testing when the other side of the cross-connect is located far away, in another room, or is inaccessible (i.e., collocation).
FlexDSX Front View
FlexDSX panel with individual jack card pulled out
FlexDSX four-port jack card
Large labels provide clear documentation
of circuits64-terminations per panel (Balun and twisted pair) – matches 2.048 Mbps equipment cabling breakouts
Large front trough avoids cable build-up
Tracer LED eliminatesmanual tracing of circuitsfor faster circuit
identificationFour-port (dual monitor)jacks allow quick isolation
of problems in largerapplications where thecross-connect may belocated far away or isinaccessible
Individualremovablejacks
Staggered jacks allow industry standard
patch cords to be used side-by-side
Chassis are configured with OUT/IN interfaces
in groups of four for easy removal andminimal disturbance of adjacent circuits
FlexDSX Rear View(1.6/5.6 Balun version shown)
Trang 7Fully-loaded, 64-circuit panel – Wire-wrap cross-connects
5.25" (13.34 cm) high, 19" (48.26 cm), EIA/IEC mounting
120 Ohm wire-wrap equipment interface
120 Ohm wire-wrap equipment interface, rear dual performance monitor
BNC Balun equipment interface1.6/5.6 Balun equipment interfaceSMB
RJ45Shielded RJ457" (17.78 cm) high*, 19" (48.26 cm), EIA/IEC mounting
BNC equipment interface1.6/5.6 equipment interface
Catalog Number
DFX-100001DFX-100001-DPMDFX-210001DFX-220001DFX-230001DFX-400001DFX-500001DFX-210001-DPM*
DFX-220001-DPM*
O r d e r i n g I n f o r m a t i o n
FlexDSX™ Panels – Four-Port (Dual Monitor) Jack Access
*The IBF-RSC024 skeleton bay holds nine 7-inch (17.78 cm) high panels
Module and Card
4-Port Jack Card with 4-Pack Module
4-Pack Module
with 1.6/5.6 connectors
4-Pack Module with wire-wrap connectors
4-Pack Module with BNC connectors
4-Port Jack Card
Description
FlexDSX 64-position empty chassis
19" (482.6mm) x 5.25" (133.35mm) (3RU)
4-pack modules
Wire-wrap, front cross-connect, 120 Ohm
BNC, front cross-connect, 75 Ohm
1.6/5.6, front cross-connect, 75 Ohm
RJ45, front cross-connect, 120 Ohm
Shielded RJ45, front cross-connect, 120 Ohm
SMB, front cross-connect, 75 Ohm
Circuit cards
FlexDSX jack, odd
FlexDSX jack, even
Catalog Number
DFX-9E0002DFX-9E1000DFX-9E2000DFX-9E3000DFX-9E4000DFX-9E4000-SDFX-9E5000
DFX-1DFX-2
O r d e r i n g I n f o r m a t i o n
Trang 8All-front-access FlexDSX panels
Empty rack (holds 10 DFX-1F0001 chassis)
Fully-loaded panel
Empty chassis
Four pack module
All-front-access FlexDSX with performance monitoring
Empty rack (holds 8 DFX-1F0001-DPM chassis)
O r d e r i n g I n f o r m a t i o n
2 Mbps Digital Cross-Connect System
All-Front-Access FlexDSX™ Panels
The all-front-access FlexDSX product family, designed for 2.048 Mbps cross-connect applications for the standard 600 mm footprint, provides 0.045" (1.14 mm) square wire-wrap pin interface options on both the cross-connect and equipment fields and is available with or without performance monitoring Each chassis holds up to 16 four-circuit front access module packs No internal wiring is required between modules and the chassis or between adjacent modules Each of the 64 individual jack cards in a fully-populated chassis have four bantam-sized ports—monitor OUT, OUT, IN, and monitor IN, as well as a red flashing tracer lamp Monitor network resistors provide 120 Ohm impedance.
FlexDSX chassis without
Trang 9PxPlus™ Panels – Three-Port Individual Jack Modularity
The PxPlus panel was designed for 2 Mbps DSX cross-connect applications where individual jack modularity
is required The PxPlus system consists of a 64-circuit empty panel and individual three-port jack access cards that are sold separately The empty panel can be loaded into the bay and precabled When service is ready to be turned up, the PxPlus jack cards are installed into the panel providing for true cost deferment.
PxPlus panel shown fully loaded with circuit cards
PxPlus Panel with individual jack card pulled out
Large removable labels provide easy documentation of
circuits to help avoid mistakes while trouble shooting
Three-port(single monitor)jack accessallows easycircuit accessfor testing,patching andmonitoring
Tracer LED eliminates manual tracing of
circuits for faster circuit identification
Designed for individual jack modularity – jacks areordered separately and installed upon service turn-up
PxPlus panel shown empty without circuit cards
Backplane can be fully prewired upon installation –allows circuit cards to be added as needed for truecost deferment
64 terminations per panel (Balun and twisted pair) matches equipment cabling breakouts
PxPlus panel (rear view)(Wire-wrap version shown)
Description
64-circuit empty chassis –
Wire-wrap equipment interfaceBNC Balun equipment interface
Jack card
Individual 120 Ohm
Catalog Number
PXP-532004PXP-532003PXP-A00006
O r d e r i n g I n f o r m a t i o n
Trang 102 Mbps DSX Front Cross-Connect Solutions
DSX 64-Termination – Three-Port Fixed Panel
Each panel supports 64 2 Mbps terminations and provides three-port jack access for monitoring, patching and testing An LED provides easy identification of cross-connect cables by eliminating manual tracing of wires The equipment (OUT/IN) cables are terminated on the rear of the chassis via wire-wrap and Balun options of 1.6/5.6 or BNC connectors The cross-connects are terminated on the front via wire-wrap pins.
DSX 64-Termination Panel (Front View)Front wire-wrap cross-connect pins for easy circuit rearrangement
Large removable labels provide easy documentation of
circuits to help avoid mistakes while troubleshooting
64-terminations per panel (Balun and twistedpair) – matches equipment cabling breakouts
DSX 64-Termination Panel (Rear View)(BNC Balun version shown)
DSX 64-Termination Panel
Three-port (single monitor) jack access allows easycircuit access for testing, patching and monitoringTracer LED eliminates manual tracing of circuits for faster circuit identification
One part number allows for
easy ordering and installation
Description
64-termination panel
120 Ohm wire-wrap equipment interfaceBNC Balun to wire-wrap equipment interface1.6/5.6 Balun to wire-wrap equipment interface
Catalog Number
D1M-1A2016D1M-1A2015D1M-1A2017
O r d e r i n g I n f o r m a t i o n
Features
• 64 terminations per panel (Balun and twisted pair) – matches 2.048 Mbps equipment cabling breakouts
• All panels mount into the ADC 600 mm skeleton bay IBF-RSC021 – one platform for all applications
• Tracer LED eliminates manual tracing of cross-connect wires for fast circuit identification
• Oversized labels for complete circuit identification
• In-service patching and circuit rearrangement allows circuit maintenance to be completed during businesshours without downtime by using ADC’s bridging office repeaters (Call your local ADC sales office formore information)
• Balun terminations increase density by converting 75 Ohm equipment cables to 120 Ohm for
cross-connecting while still providing the flexibility of DSX jack access Available in BNC and 1.6/5.6
Trang 11450 mm deep end guard
600 mm deep end guard
300 mm deep end guard
End Guard for Use with Door Enclosure Kit
This end guard kit is used in conjunction with the DSX frame doors used to enclose the frame It also provides protection and a finished appearance to the start and end of the frame lineup.
Description
150 mm filler panel kit
300 mm filler panel kit that includes upper and lower
cable trough
Catalog Number
SFK-122150SFK-122300
O r d e r i n g I n f o r m a t i o n
Filler Panel Kits
The filler panel kits add spacing between DSX frames The kits come in 150 mm and 300 mm
measurements.
* Each kit comes with two end guards
Trang 122 Mbps Digital Cross-Connect System
Bay Hardware and Accessories
Rack Installation Kit
This rack installation kit comes with all the necessary hardware to install the DSX rack in a raised floor environment.
AC Outlet Kit
This AC outlet kit is a universal continental Europe outlet that mounts in the base of the frame.
Description
Zone 2 raised floor mounting kit
Concrete floor kit
Catalog Number
RAC-MX0615RAC-MX0616
O r d e r i n g I n f o r m a t i o n
Description
UK AC outlet kit
Continental Europe AC outlet kit
North American AC outlet kit
Catalog Number
AUX-AC0003AUX-AC0004AUX-AC0005
O r d e r i n g I n f o r m a t i o n
Note: See installation guidelines for instructions on mounting the DSX Frame
Cross Aisle Panels
Description
128-circuit cross aisle panel
64-circuit cross aisle panel with trace LEDs
Catalog Number
AUX-200022AUX-200064