What is the maximum allowed deployment time of the pick-up gear for one man?. After breaking the weak link in the securing device the tugboat should let the wire run out by its own weigh

Trang 1

What is the maximum allowed deployment time of the pick-up gear for one man? (Aft System)

5 minutes

10 minutes

15 minutes

20 minutes

What is the maximum allowed deployment time for the forward ets system?

15 minutes

30 minutes

1.5 hours

1 hour

The ETS 100D is designed for the following ship type?

Tankers between 20 and 50.000 tdw.

Tankers below 30.000 tdw

Tankers above 60.000 tdw

Tankers between 30 and 60.000 tdw

Deployment, Emergency procedure: Which statement is correct?

After breaking the weak link in the securing device the tugboat should let the wire run out by its own weight.

Test Procedure: Which statements is correct when you are following the test procedure

Remove the weak link at the storage drum, before you go to the pick-up gear container and throw the buoys in the water.

Go to the pick-up gear container and throw the buoys in the water, before removing the weak link at the storage drum

You must never feed the messenger rope and wire into the sea

In the test procedure, the wire will not run out by its own weight

Packing of pick-up gear container procedure: How do you check that the light bulbs is flashing? Turn the boys with the bulbs pointing down for a few seconds and up again

Turn the light bulb off then on again for a few seconds

Move the buoys up then down rapidly again a few times

Hold the buoys in an upright position for a few seconds.

When shall the three batteries in each buoy be replaced?

In the 6th months Maintenance

In the 12th months Maintenance

In the 2-year Maintenance

In the daily Maintenance

How often shall the weak link and the turnbuckle be checked?

In the 6th months Maintenance

Trang 2

In the 12th months Maintenance

In the 2-year Maintenance

In the daily Maintenance

How often is it necessary to mount the air motor and unreel the entire length of the towing wire and check for any damage?

In the 6th months Maintenance

In the 12th months Maintenance

In the 2-year Maintenance

In the daily Maintenance

What is the correct thing to do when the light bulbs are not flashing when holding the buoys in

an upright position?

Replace the batteries and/or the electronic unit with bulb.

Replace the batteries and/or the lamp

First replace the bulb then replace the batteries

Replace the entire top unit

How often must the centrifugal brake be inspected?

In the 6th months Maintenance

In the 12th months Maintenance

In the 2-year Maintenance

In the daily Maintenance

Which one of the IMO publications given in the options sets out the requirements for

emergency towing system, ETS

STCW

FSS code

MARPOL

SOLAS

The ETS 100F is designed for the following ship type?

Tankers between 20 and 50.000 tdw.

Tankers below 20.000 tdw

Tankers above 100.000 tdw

Tankers between 50 and 100.000 tdw