Annex B Cable ANEXT loss and AFEXT loss reference test procedure normative... Annex C Connecting hardware ANEXT loss and AFEXT loss reference test procedure... Annex D Channel ANEXT loss
Trang 1NOTICE OF DISCLAIMER AND LIMITATION OF LIABILITY
Trang 3TIA SHALL NOT BE LIABLE FOR ANY AND ALL DAMAGES, DIRECT OR INDIRECT, ARISING FROM
Trang 4TRANSMISSION PERFORMANCE SPECIFICATIONS
Trang 57.4.3 Connecting hardware return loss 28
Trang 7G.3.1 Test plug construction 69
Trang 9Table 28 - Augmented category 6 cord cable return loss 27
Trang 11Category 6 Category 3 Category 5 Category 5e Category 6 Augmented Category 6 1) Category 3 plug performance requirements are assumed to be less restrictive than category 5e
Trang 13average PSANEXT loss: The calculated average of the individual PSANEXT loss values for all
Trang 14Work area cord A Telecommunications outlet/
Optional consolidation point cabling B connector WA
Horizontal cabling C Optional consolidation
Patch cord or jumper cable D point connector CP
Telecommunications room Horizontal cross-connect or
equipment cord E interconnect C1, C2
Trang 15The permanent link test configuration is defined in ANSI/TIA/EIA-568-B.1 A supplemental
Test equipment cord F Telecommunications outlet/
Optional consolidation point cabling B connector WA
Horizontal cabling C Optional consolidation
Horizontal cross-connect or interconnect C1
Maximum length
B + C 90 m (295 ft)
Test instrument
instrumentCP
Permanent link under test
Trang 16Insertion loss (dB)
1.00 2.0 4.00 3.7 8.00 5.2 10.00 5.9 16.00 7.4 20.00 8.3 25.00 9.3 31.25 10.4 62.50 14.9 100.00 19.0 200.00 27.5 250.00 31.0 300.00 34.2 400.00 40.0 500.00 45.3
Trang 177.1.2 Connecting hardware insertion loss
Insertion loss (dB)
1.00 0.02 4.00 0.04 8.00 0.06 10.00 0.06 16.00 0.08 20.00 0.09 25.00 0.10 31.25 0.11 62.50 0.11 100.00 0.16 200.00 0.20 250.00 0.28 300.00 0.32 400.00 0.35 500.00 0.40
11
12
Trang 187.1.3 Cabling insertion loss
f f
oss InsertionL channel≤1.05(1.8 +0.01 + 0.2)+4⋅0.02 dB (4)
1 ( 03 0
100 ,
f f f
1.00 2.2 4.00 4.1 8.00 5.7 10.00 6.4 16.00 8.1 20.00 9.1 25.00 10.2 31.25 11.4 62.50 16.3 100.00 20.8 200.00 30.0 250.00 33.8 300.00 37.3 400.00 43.6 500.00 49.3
Trang 197.1.3.2 Permanent link insertion loss
12
13
5 1 _ 0 00015 f ILDperm link = dB (TBD – Editor: See TBD in equation (9) also) (8)
.
f f f
1.00 1.9 4.00 3.5 8.00 4.9 10.00 5.5 16.00 6.9 20.00 7.7 25.00 8.7 31.25 9.7 62.50 13.9 100.00 17.9 200.00 26.0 250.00 29.4 300.00 32.6 400.00 38.4 500.00 43.8
22
Trang 207.2 NEXT loss and PSNEXT loss
15 3
NEXT loss (dB)
0.150 86.7 0.772 76.0 1.00 74.3 4.00 65.3 8.00 60.8 10.00 59.3 16.00 56.2 20.00 54.8 25.00 53.3 31.25 51.9 62.50 47.4 100.00 44.3 200.00 39.8 250.00 38.3 300.00 37.1 400.00 35.3 500.00 33.8
23
NOTE - 0.150 MHz is for reference purposes only
24
25
Trang 217.2.1.2 Connecting hardware NEXT loss
NEXT loss (dB)
NEXT loss (dB)
1.00 75.0 4.00 75.0 8.00 75.0 10.00 74.0 16.00 69.9 20.00 68.0 25.00 66.0 31.25 64.1 62.50 58.1 100.00 54.0 200.00 48.0 250.00 46.0 300.00 42.9 400.00 37.9 500.00 34.0
13
14
Trang 227.2.1.3 Work area, equipment, and patch cord NEXT loss
IL cable NEXT connectors
NEXT limit
1010
log10_
2010
log20
conn IL cable IL conn NEXT conn
NEXT connectors
8
9
100100
,
h CableLengt m
cable IL IL DeRating cable
IL ,100 is the insertion loss of 100 meters of cable as specified in equation (1)
18
19
IL Derating is the de-rating factor specified for cable as specified in equation (2)
Trang 23NEXT ,100 is the NEXT loss test limit for 100 m cable as specified in equation (10)
17
18
19
20
Trang 247.2.1.4 Channel NEXT loss
))100/log(
2054(10220
))100/log(
153.44(10log(
20
f f
channel NEXT
−
−
⋅+
15.27
channel NEXT ≥ −
1.00 65.0 4.00 63.0 8.00 58.2 10.00 56.6 16.00 53.2 20.00 51.6 25.00 50.0 31.25 48.4 62.50 43.4 100.00 39.9 200.00 34.8 250.00
300.00
33.1 31.7 400.00 28.7 500.00 26.1
12
13
Trang 257.2.1.5 Permanent link NEXT loss
)) 100 / log(
20 54 ( 10 20
)) 100 / log(
15 3 44 ( 10 log(
20
_
f f
NEXTperm link
−
− +
13.3334
1.00 65.0 4.00 64.1 8.00 59.4 10.00 57.8 16.00 54.6 20.00 53.1 25.00 51.5 31.25 50.0 62.50 45.1 100.00 41.8 200.00 36.9 250.00 35.3 300.00 34.0 400.00 29.9 500.00 26.7
11
12
Trang 2610 log(
15 3
0.150 84.7 0.772 74.0 1.00 72.3 4.00 63.3 8.00 58.8 10.00 57.3 16.00 54.2 20.00 52.8 25.00 51.3 31.25 49.9 62.50 45.4 100.00 42.3 200.00 37.8 250.00 36.3 300.00 35.1 400.00 33.3 500.00 31.8
Trang 277.2.2.2 Channel PSNEXT loss
1 ≤ f < 330
330 ≤ f ≤ 500
)20
))100/log(
2050(10220
))100/log(
153.42(10log(
20
f f
channel PSNEXT
−
−
⋅+
43.26
PSNEXT loss (dB)
1.00 62.0 4.00 60.5 8.00 55.6 10.00 54.0 16.00 50.6 20.00 49.0 25.00 47.3 31.25 45.7 62.50 40.6 100.00 37.1 200.00 31.9 250.00
300.00 30.2 28.8 400.00 25.8 500.00 23.2
13
14
15
Trang 287.2.2.3 Permanent link PSNEXT loss
1 ≤ f < 300
300 ≤ f ≤ 500
20
)) 100 / log(
20 50 ( 10 20
)) 100 / log(
15 3 42 ( 10 log(
20
_
f f
PSNEXTperm link
−
− +
44.344.31
PSNEXT loss (dB)
1.00 62.0 4.00 61.8 8.00 57.0 10.00 55.5 16.00 52.2 20.00 50.7 25.00 49.1 31.25 47.5 62.50 42.7 100.00 39.3 200.00 34.3 250.00 32.7 300.00 31.4 400.00 27.1 500.00 23.8
12
13
Trang 297.3 ELFEXT, FEXT loss, and PSELFEXT
20 8
1.00 67.8 4.00 55.8 8.00 49.7 10.00 47.8 16.00 43.7 20.00 41.8 25.00 39.8 31.25 37.9 62.50 31.9 100.00 27.8 200.00 21.8 250.00 19.8 300.00 18.3 400.00 15.8 500.00 13.8
23
24
Trang 304 10
log(
conn cable FEXT ELFEXT
ELFEXT (dB)
1.00 63.3 4.00 51.2 8.00 45.2 10.00 43.3 16.00 39.2 20.00 37.2 25.00 35.3 31.25 33.4 62.50 27.3 100.00 23.3 200.00 17.2 250.00 15.3 300.00 13.7 400.00 11.2 500.00 9.3
15
16
Trang 317.3.1.3 Permanent link ELFEXT
20 10
log(
20
_
conn cable
link perm
FEXT ELFEXT
ELFEXT
−
⋅ +
1.00 64.2 4.00 52.1 8.00 46.1 10.00 44.2 16.00 40.1 20.00 38.2 25.00 36.2 31.25 34.3 62.50 28.3 100.00 24.2 200.00 18.2 250.00 16.2 300.00 14.6 400.00 12.1 500.00 10.2
15
16
Trang 3220 1
1.00 75.0 4.00 71.1 8.00 65.0 10.00 63.1 16.00 59.0 20.00 57.1 25.00 55.1 31.25 53.2 62.50 47.2 100.00 43.1 200.00 37.1 250.00 35.1 300.00 33.6 400.00 31.1 500.00 29.1
12
13
Trang 3310 log(
20 8
PSELFEXT (dB)
1.00 64.8 4.00 52.8 8.00 46.7 10.00 44.8 16.00 40.7 20.00 38.8 25.00 36.8 31.25 34.9 62.50 28.9 100.00 24.8 200.00 18.8 250.00 16.8 300.00 15.3
Trang 344 10
log(
conn cable PSFEXT PSELFEXT
PSELFEXT (dB)
1.00 60.3 4.00 48.2 8.00 42.2 10.00 40.3 16.00 36.2 20.00 34.2 25.00 32.3 31.25 30.4 62.50 24.3 100.00 20.3 200.00 14.2 250.00 12.3 300.00 10.7 400.00 8.2 500.00 6.3
15
16
Trang 357.3.3.3 Permanent link PSELFEXT
320
10log(
20
_
conn cable
link perm
PSFEXT PSELFEXT
PSELFEXT
−
⋅+
1.00 61.2 4.00 49.1 8.00 43.1 10.00 41.2 16.00 37.1 20.00 35.2 25.00 33.2 31.25 31.3 62.50 25.3 100.00 21.2 200.00 15.2 250.00 13.2 300.00 11.6 400.00 9.1 500.00 7.2
14
15
Trang 36Return loss (dB)
Return loss (dB)
1.00 20.0 4.00 23.0 8.00 24.5 10.00 25.0 16.00 25.0 20.00 25.0 25.00 24.3 31.25 23.6 62.50 21.5 100.00 20.1 200.00 18.0 250.00 17.3 300.00 16.8 400.00 15.9 500.00 15.2
19
20
Trang 377.4.2 Cord cable return loss
Return loss (dB)
Return loss (dB)
1.00 20.0 4.00 23.0 8.00 24.5 10.00 25.0 16.00 25.0 20.00 25.0 25.00 24.2 31.25 23.3 62.50 20.7 100.00 19.0 200.00 16.4 250.00 15.6 300.00 14.9 400.00 13.8 500.00 13.0
12
13
Trang 387.4.3 Connecting hardware return loss
Return loss (dB)
1.00 30.0 4.00 30.0 8.00 30.0 10.00 30.0 16.00 30.0 20.00 30.0 25.00 30.0 31.25 30.0 62.50 30.0 100.00 28.0 200.00 22.0 250.00 20.0 300.00 18.5 400.00 16.0 500.00 14.0
Trang 397.4.4 Work area, equipment, and patch cord return loss
Return loss (dB)
1 ≤ f < 25
25 ≤ f ≤ 250
250 < f < 500
24+3log(f/25) 24-10log(f/25) 14-15log(f/250)
6
Table 32 - Augmented category 6 work area, equipment, and patch cord return loss
7
Frequency (MHz) Return loss (dB)
1.00 19.8 4.00 21.6 8.00 22.5 10.00 22.8 16.00 23.4 20.00 23.7 25.00 24.0 31.25 23.0 62.50 20.0 100.00 18.0 200.00 15.0 250.00 14.0 300.00 12.8 400.00 10.9
500.00 9.5
8
9
10
Trang 407.4.5 Cabling return loss
1.00 19.0 4.00 19.0 8.00 19.0 10.00 19.0 16.00 18.0 20.00 17.5 25.00 17.0 31.25 16.5 62.50 14.0 100.00 12.0 200.00 9.0 250.00 8.0 300.00 7.2 400.00 6.0 500.00 6.0
13
14
Trang 417.4.5.2 Permanent link return loss
Return loss (dB)
1.00 19.1 4.00 21.0 8.00 21.0 10.00 21.0 16.00 20.0 20.00 19.5 25.00 19.0 31.25 18.5 62.50 16.0 100.00 14.0 200.00 11.0 250.00 10.0 300.00 8.4 400.00 8.0 500.00 8.0
12
13
Trang 427.5 Propagation delay/delay skew
Propagation Delay (ns/100 m)
1.00 4.00 8.00 10.00 16.00 20.00 25.00 31.25 62.50 100.00 200.00 250.00 300.00 400.00 500.00
Trang 437.5.2 Cabling propagation delay
Trang 44TCL (dB)
1.00 40.0 4.00 40.0 8.00 40.0 10.00 40.0 16.00 38.0 20.00 37.0 25.00 36.0 31.25 35.1 62.50 32.0 100.00 30.0 200.00 27.0 250.00 26.0 300.00 25.2 400.00 24.0 500.00 23.0
14
Trang 451.00 40.0 4.00 40.0 8.00 40.0 10.00 40.0 16.00 40.0 20.00 40.0 25.00 40.0 31.25 38.1 62.50 32.1 100.00 28.0 200.00 22.0 250.00 20.0 300.00 18.5 400.00 16.0 500.00 14.0
13
14
Trang 46TCLchannel ≥ − (TBD)
) log(
TCL (dB)
Trang 47ELTCTL (dB)
1.00 35.0 4.00 23.0 8.00 16.9 10.00 15.0 16.00 10.9 20.00 9.0 25.00 7.0 30.00 5.5
19
20
Trang 481.00 40.0 4.00 40.0 8.00 40.0 10.00 40.0 16.00 40.0 20.00 40.0 25.00 40.0 31.25 38.1 62.50 32.1 100.00 28.0 200.00 22.0 250.00 20.0 300.00 18.5 400.00 16.0 500.00 14.0
13
14
Trang 507.8 ANEXT loss and PSANEXT loss
15 5
Trang 517.8.2 Connecting hardware PSANEXT loss
20 5
Trang 527.8.3 Channel PSANEXT loss
PSANEXT loss (dB)
PSANEXT loss (dB)
1.00 67.0 4.00 67.0 8.00 67.0 10.00 67.0 16.00 67.0 20.00 67.0 25.00 66.0 31.25 65.1 62.50 62.0 100.00 60.0 200.00 55.5 250.00 54.0 300.00 52.8 400.00 51.0 500.00 49.5
12
13
14
Trang 537.8.4 Permanent link PSANEXT loss
PSANEXT loss (dB)
PSANEXT loss (dB)
Trang 547.9 Average ANEXT loss and PSANEXT loss
1
_ )
i pair f
avg
f PSANEXT
f PSANEXT ( ) _ is the magnitude in dB of PSANEXT loss at frequency I of pair i
Average PSANEXT loss
Average PSANEXT loss (dB)
1.00 67.0 4.00 67.0 8.00 67.0 10.00 67.0 16.00 67.0 20.00 67.0 25.00 67.0 31.25 67.0 62.50 64.3 100.00 62.3 200.00 57.7 250.00 56.3 300.00 55.1
Trang 557.10 AFEXT loss, AELFEXT, and PSAACRF
AFEXTnorm k
j
n i
j k
i IL k IL AFEXT
j i k
,
log 10 ) , (
i k
Trang 5620 2
PSAACRF (dB)
Trang 577.10.2 Connecting hardware PSAFEXT loss
PSAFEXT loss (dB)
Trang 581.00 77.0 4.00 65.0 8.00 58.9 10.00 57.0 16.00 52.9 20.00 51.0 25.00 49.0 31.25 47.1 62.50 41.1 100.00 37.0 200.00 31.0 250.00 29.0 300.00 27.5 400.00 25.0 500.00 23.0
13
14
Trang 597.10.4 Permanent link PSAACRF
20 7 37
PSAACRF (dB)
Trang 607.11 Average AELFEXT and PSAACRF
f PSAACRF
f PSAACRF ( ) _ is the magnitude, in dB, of PSAACRF at frequency f of pair I
20 41
Average PSAACRF loss (dB)
1.00 75.0 4.00 69.0 8.00 62.9 10.00 61.0 16.00 56.9 20.00 55.0 25.00 53.0 31.25 51.1 62.50 45.1 100.00 41.0 200.00 35.0 250.00 33.0 300.00 31.5 400.00 29.0 500.00 27.0
23
24
Trang 61Annex A Cabling measurement requirements (normative)
Impedance, primary 1) 1 ≤ f ≤ 500 50 Ω unbalanced
Impedance, secondary 1 ≤ f ≤ 500 100 Ω balanced
Return loss, bi-directional 2) 1 ≤ f < 15
15 ≤ f ≤ 500
12 dB minimum
20 dB minimum Return loss, common mode 2) 1 ≤ f < 15
Common mode rejection 2) 1 ≤ f ≤ 500 50 dB minimum
1) Primary impedance may differ, if necessary, to accommodate analyzer outputs other than
Trang 62Figure A.1 depicts the proper test configurations for qualifying test baluns to the requirements of
A-B: 100 Ω Balanced C: 50 Ω Common-Mode D: 50 Ω UnbalancedReturn Loss (50:100 ohm)
A
DCB
50 Ω
AD
50 Ω
AD
50 Ω
AD
A
DCB
50 Ω
50 Ω
50 Ω
AD
50 Ω
Trang 63Annex B Cable ANEXT loss and AFEXT loss reference test procedure (normative)
Trang 64Annex C Connecting hardware ANEXT loss and AFEXT loss reference test procedure
Trang 65For pair-to-pair AFEXT loss measurement, it is recommended that the far-end of the disturbing
DUT1 (Victim)DUT2(Disturber)
Trang 66CMDM 4 Pair Termination.
DUT1 (Victim)
DUT2 (Disturber)
Terminating Cable
Trang 6710 10
10 log(
10 10
10 log(
Trang 68Annex D Channel ANEXT loss and AFEXT loss laboratory measurement procedures
Trang 69It shall be acceptable to have a short length, up to 0.3 m (1.0 ft), of the cable not tightly bundled, for
Trang 70D.5 Channel ANEXT loss and AFEXT loss measurements and computations
Channel Under Test (Victim)
Channel Under Test (ANEXT Disturber)
Channel Under Test (AFEXT Disturber)
Channel Not Under Test (Disturber 3) Channel Not Under Test (Disturber 4)
Channel Not Under Test (Disturber 5) Channel Not Under Test (Disturber 6)
Trang 71Annex E Field measurement method for alien crosstalk (normative)
10 log(
10 0 1 , 1 , 1 0 1 , 2 , 1 0 1 , 3 , 1
1 , = − − PPANEXT X + − PPANEXT X + − PPANEXT X +
X
PSANEXT
33
Trang 72PPANEXTX,Y,1 is the pair-to-pair alien NEXT loss from wire pair X in the disturbed permanent
10X,1PSANEXT0.1
10log(10total
=
1 IL X,1 IL log 10 1 IL X,1 IL X,1,1 PPAFEXT X,1,1
X,3,1 c 0.1PPAFEXT 10
X,2,1 c 0.1PPAFEXT 10
X,1,1 c 0.1PPAFEXT 10log(10
X,1
+
− +
− +
10X,1PSAFEXT0.1
10log(10total
1 avg
IL
40
41
42
Trang 73E.5.3 Applying the correction for the measurement floor (optional)
⋅
=
Npp
Nps 4 log 10 f dB Nps, floor,4 PSAXtalk f
dB Npp, floor,
.010kPSANEXT1
.010log
10
krectedPSANEXTcor
.010kPSAFEXT1
.010log
10
krectedPSAFEXTcor
Trang 74E.6 Power sum alien crosstalk test strategy
Trang 75Modular cordunder test
50 50 25
50 50 50 50
Far end test head
50 50 25
D
C G
test interface
Near end test head
Annex F Modular plug cord test procedure (normative)
Trang 76F.3 Augmented category 6 modular plug cord test procedure
NEXT loss requirements are given in clause 7.2.1.3 and return loss in clause 7.4.4 9
F.4 Augmented category 6 modular plug cord test head requirements
Trang 77F.4.2 Augmented category 6 modular cord test head FEXT loss
20 1 48
Return loss (dB)
Trang 78Annex G Connecting hardware test procedures (normative)
Trang 79G.2.2.4 Termination performance at test interface
Trang 80G.3.3 Connecting hardware NEXT loss testing
Trang 81G.3.5 Augmented category 6 modular test plug NEXT loss requirements
combination Limit NEXT loss magnitude limit 1),4),5) NEXT loss phase limit 2),3)
Case 1 3,6-4,5 Low ≤ 38.1-20log(f/100) TBD (-90 + 1.5 f /100) ± f /100
TBD Case 2 3,6-4,5 Central (38.8 ± 0.2)-20log(f /100) TBD (-90 + 1.5 f /100) ± f /100
TBD Case 3 3,6-4,5 High ≥ 39.5-20log(f /100) TBD (-90 + 1.5 f /100) ± f /100
TBD Case 4 1,2-3,6 Low ≤ 46.5-20log(f /100) TBD (-90 + 1.5 f /100) ± 3 f /100
TBD Case 5 1,2-3,6 High ≥ 49.5-20log(f /100) TBD (-90 + 1.5 f /100) ± 3 f /100
TBD Case 6 3,6-7,8 Low ≤ 46.5-20log(f /100) TBD (-90 + 1.5 f /100) ± 3 f /100
TBD Case 7 3,6-7,8 High ≥ 49.5-20log(f /100) TBD (-90 + 1.5 f /100) ± 3 f /100
TBD Case 8 1,2-4,5 Low ≤ 57-20log(f /100) TBD 90 ± (30 f /100) TBD Case 9 1,2-4,5 High ≥ 70-20log(f /100) TBD any phase
Case 10 4,5-7,8 Low ≤ 57-20log(f /100) TBD 90 ± (30 f /100) TBD Case 11 4,5-7,8 High ≥ 70-20log(f /100) TBD any phase
Case 12 1,2-7,8 Low ≤ 66-20log(f /100) TBD any phase
1) Magnitude limits apply over the frequency range from 10 to 500 MHz
2) Phase limits apply over the frequency range from 50 to 500 MHz
3) When the measured plug NEXT loss is greater than 70 dB, the phase limit does not apply 4) When a low limit NEXT loss calculation results in a value greater than 70 dB, there shall be no low limit for NEXT loss
5) When a high limit NEXT loss calculation results in a value greater than 70 dB, the high limit NEXT loss shall revert to a limit of 70 dB
Trang 82When testing a particular pair combination, the direct measurement test plug NEXT loss
combination NEXT loss magnitude range 1),4),5) NEXT loss phase range 2),3)
3,6-4,5 38.1-20log(f/100) TBD ≤ NEXT loss ≤
1) Magnitude limits apply over the frequency range from 10 MHz to 500 MHz
2) Phase limits apply over the frequency range from 50 MHz to 500 MHz
3) When the measured plug NEXT loss is greater than 70 dB, the phase limit does not apply 4) When a high limit NEXT loss calculation results in a value greater than 70 dB, there shall be
no high limit for NEXT loss Refer to Table H.2 for an explanation of the high limit
5) When a low limit NEXT loss calculation results in a value greater than 70 dB, the low limit shall revert to 70 dB Refer to table H.2 for an explanation of the low limit
6) When the NEXT loss magnitude exceeds 70 – 20 log (f/100), the phase requirement does not apply
7) The requirements for 1-2,4-5 and 4,5-7,8 do not exclude plugs that meet cases 9 and 11, respectively, shown in table H.2, because such plugs are acceptable for field tester adapters