Th e kinds of household utensils contain-ing hypochlorite are numerous; therefore the poisoncontain-ing cases, due to accidental contain-ingestion of hypochlorite and due to inhalation o
Trang 1© Springer-Verlag Berlin Heidelberg 2005
Introduction
Hypochlorite a ( HClO) is a weak acid, which exerts oxidative action; it is being widely used in the salt forms for bleaching and other purposes Sodium hypochlorite ( NaClO) aqueous solu-tion is usually used as a disinfectant, bleaching agent, fungicide and ink eraser, and is thus usually included in detergents for laundry Calcium hypochlorite [ Ca(ClO)2, bleaching pow-der] is also used as a bleaching agent and disinfectant Th e kinds of household utensils contain-ing hypochlorite are numerous; therefore the poisoncontain-ing cases, due to accidental contain-ingestion of hypochlorite and due to inhalation of chlorine gas produced upon mixing a hypochlorite salt with an acidic solution, are relatively many Th e toxicity of the aqueous solution of a hypochlo-rite salt is due to injuries of the mucous membranes caused by its strong alkali and oxidizing actions, and due to disturbances of the respiratory organs caused by inhalation of chlorine gas produced under acidic conditions Th e oral LD50 value of hypochlorite for rats is 850 mg/kg
To detect hypochlorite, a preliminary qualitative test using the iodine-starch paper is being usually used However, this method is not specifi c for hypochlorite, but is generally responsive
to every oxidizing compound; it is not suitable for specifying hypochlorite For analysis of hypochlorite, the detection of a hypochlorite ion is most preferable In this chapter, a capillary electrophoresis (CE) method for analysis of hypochlorite is presented
Reagents and their preparation
Sodium hypochlorite solution commercially available is diluted with 0.05 M NaOH solution to prepare 500 µg/mL (in the form of a hypochlorite ion) stock solution Various concentrations
of the solution are prepared by diluting the stock solution with 0.05 M NaOH solution for constructing a calibration curve
CE conditions
CE column: a fused silica capillary column (104 cm × 50 µm i d.)
CE conditions: an HP3DCE system (Yokogawa Analytical Systems, Tokyo, Japan); buff er solution: HP Basic Anion Buff er; column temperature: 30 °C; impressed voltage: –30 kV; detection: indirect absorption detection (signal 350/20 nm, reference 275/10 nm); sample in-jection: pressure injection (50 mbar, 6 s)
Trang 2i A specimen solution is appropriately diluted with distilled water, and passed through a membrane fi lter of 0.25 µm cellulose acetate
ii Th e above solution is placed in a sample vial to be set for CE
iii Calculation: known concentrations of hypochlorite solutions are analyzed by the above CE
to construct a calibration curve (concentration of a hypochlorite ion in a specimen vs peak
area) A peak area obtained from a specimen is applied to the calibration curve to obtain its concentration
Assessment of the method
> Figure 1.1 shows an electropherogram for the standard solution of 500 µg/mL hypochlorite ion Th e hypochlorite ion ( ClO–) was eluted at 8.2 min Peaks observable at 6.0, 6.9 and 7.1 min were due to chloride ion ( Cl–), chlorate ion ( ClO3–) and carbonate ion ( CO32–), respectively Even in the undiluted sodium hypochlorite solution, decomposition product chloride and chlorate ions are contained During preparation of the solutions and also during analysis, there
is a possibility of decomposition of the hypochlorite ion As shown in > Figure 1.1, the peaks
of such decomposition products are remarkably observed even in the electropherogram for the standard sodium hypochlorite solution Th e carbonate ion observed in the chromatogram is due to atmospheric carbon dioxide, which is easily dissolved in alkaline solution
Th e present CE conditions can be used for general analysis of negative ions, including cyanide, azide and arsenate [1, 2]; the conditions can be also applied to chlorate and analogous anions Th e pH of the buff er is about 12; under this condition, the decomposition of hypochlo-rite ion is suppressed Since it is diffi cult to prepare the standard hypochlorite solution without any decomposition, the true hypochlorite concentration in a specimen is lower than the value calculated using the calibration curve
⊡ Figure 1.1
Electropherogram for the hypochlorite ion (data donated by Yokogawa Analytical Systems).
Trang 3Th e hypochlorite is decomposed very easily Especially in biomedical specimens, it reacts with proteins and other components and is decomposed very rapidly Because of such reasons, there are no data available on the fatal blood levels of hypochlorite Th ere is a report describing the diffi culty for detecting hypochlorite from blood of a victim, who committed suicide by ingest-ing a bleachingest-ing agent [3]
Notes
a) Hypochlorite is very unstable in acidic aqueous solution It is decomposed to produce chlorine gas At neutral pHs, the compound produces both chlorate and chloride ions by disproportionation reaction; at alkaline pHs, it is relatively stable Hypochlorite is decom-posed under weakly alkaline or weakly acidic conditions to produce chloride ion together with oxygen in the activated state, resulting in its bleaching action
References
1) Yokogawa Analytical Systems (1999) Instruction Manual for the Kit To Be Used for Capillary Electrophoresis Analysis of Toxic Anions, HP5964-3029, Tokyo (in Japanese)
2) Soga T, Ross GA (1999) Simultaneous determination of inorganic anions, organic acids, amino acids and carbo-hydrates by capillary electrophoresis J Chromatogr A 837:231–239
3) Kamiyama S, Beppu K (1979) A fatal suicidal case by drinking of liquid bleach Jpn J Legal Med 33:13–19 (in Japanese with an English abstract)