Alarm: discontinuity across B-C continuity across A-C, Normal: continuity across B-C discontinuity across A-C Contact capacity 230VAC 0.3A power factor =0.4 30VDC 0.3A A2, B2, C2 Relay o
Trang 1Dimension Drawings
Protective Functions
Peripheral Devices
A1, B1, C1 Relay output 1 (alarm output)
1 changeover contact output indicates that the inverter protective function has activated and the output stopped Alarm: discontinuity across B-C (continuity across A-C), Normal:
continuity across B-C (discontinuity across A-C) Contact capacity 230VAC 0.3A (power factor =0.4) 30VDC 0.3A
A2, B2, C2 Relay output 2 1 changeover contact output, contact capacity 230VAC, 0.3A (power factor=0.4) 30VDC 0.3A
RUN Inverter running Switched low when the inverter output frequency is equal to or higher than the starting frequency (initial value 0.5Hz)
Switched high during stop or DC injection brake operation.*1
Permissible load 24VDC 0.1A
(a voltage drop is 2.8V maximum when the signal is on)
Switched low when the output frequency reaches within the range of ±10% (initial value)
of the set frequency Switched high during acceleration/deceleration and at a stop.*1
Alarm code (4bit) output
(Refer to page 53.)
Switched low when stall prevention is activated by the stall prevention function
Switched high when stall prevention is cancelled.*1
IPF Instantaneous power failure Switched low when an instantaneous power failure and under voltage
protections are activated.*1
FU Frequency detection
Switched low when the inverter output frequency is equal to or higher than the preset detected frequency and high when less than the preset detected frequency.*1
SE Open collector output common Common terminal for terminals RUN, SU, OL, IPF, FU
For meter
Select one e.g output frequency from monitor items.*2
The output signal is proportional to the magnitude of the corresponding monitoring item
Output item: output frequency (initial setting),
permissible load current 2mA,
1440 pulses/s at 60Hz Open collector output Signals can be output from the open collector terminals by setting Pr.291 (maximum output
pulse: 50kpulses/s)
Output item: output frequency (initial setting),
output signal 0 to 10VDC, permissible load current 1mA(load impedance 10kΩ or more),
resolution 8 bit
With the PU connector, communication can be made through RS-485 (1:1 connection only)
⋅ Conforming standard: EIA-485(RS-485)
⋅ Transmission format: Multi-drop link ⋅ Communication speed: 4800 to 38400bps⋅ Overall extension: 500m
RS-485
terminals
TXD+,
TXD- Inverter transmission terminal With the RS-485 terminals, communication can be made through RS-485.
RXD+,
RXD- Inverter reception terminal ⋅ Conforming standard: EIA-485(RS-485)
⋅ Transmission format: Multi-drop link ⋅ Communication speed: 300 to 38400bps⋅ Overall extension: 500m
SG Earth (Ground)
The FR-Configurator can be operated by connecting the inverter to the personnel computer through USB
⋅ Interface: conforms to USB1.1
⋅ Transfer rate: FS transfer (12Mbps) ⋅ Connector: USB series B connector
CAUTION
⋅ The inverter will be damaged if power is applied to the inverter output terminals (U, V, W) Never perform such wiring
⋅ indicates that terminal functions can be selected from Pr.178 to Pr.196 (I/O terminal function selection).
⋅ Terminal names and terminal functions are those of the factory set
*1 Low indicates that the open collector output transistor is on (conducts) High indicates that the transistor is off (does not conduct)
*2 Not output during inverter reset
Trang 2Wiring example Standard motor with encoder (SF-JR), 5V differential line driver (speed control)
R/L1 S/L2 T/L3 R1/L11 S1/L21
10(+5V) 2 2
3
1
1
SF-JR motor with encoder
C1 B1 A1
U V W
U V W E
C
P1
C2 B2 A2
*
5
(+) (-)
R
PX PR N/-P/+
R PA1
FR-A7AP
PA2 PB1 PB2 PZ1 PZ2 PG
PG SD
SD
Terminating resistor
ON
OFF
5VDC power supply
A N B P H K
IM
STF STR STOP RH RM RL JOG RT MRS RES
AU CS SD
* Earth the shield cable of the encoder cable to the enclosure with a P clip, etc.
Encoder
RUN SU IPF OL FU
SE
Earth (ground)
(+) (-) Differential line driver
Complimentary
Main circuit terminal
Control circuit terminal
Sink logic
Three-phase AC
power supply
MC MCCB
Jumper
Jumper Jumper
Open collector output
Open collector output common
Frequency detection
Running
Up to frequency Instantaneous power failure Overload
Relay output
Relay output 2
Relay output 1 (alarm output)
(Analog common)
0 to ±10VDC
0 to 5VDC
0 to 10VDC
4 to 20mADCselected
selected
0 to ±5VDC
(Initial value)
(Initial value)
Forward rotation start Reverse rotation start Start self-holding selection
Middle speed High speed
Low speed Jog mode
Second function selection
Output stop
Reset Terminal 4 input selection
(current input selection) Selection of automatic restart
after instantaneous power failure
Contact input common
Control input signals (no voltage input allowed)
Main circuit Control circuit
Frequency setting
potentiometer 1/2W1kΩ
torque limit command
( 10V)
Trang 3Dimension Drawings
Protective Functions
Peripheral Devices
*1 For the fan of the 7.5kW or less dedicated motor, the power supply is single phase (200V/50Hz, 200 to 230V/60Hz)
*2 Assign OH (external thermal input) signal to the terminal CS (Set "7" in Pr 186.)
Connect a 2WlkΩ resistor between the terminal PC and CS (CH) Install the resistor pushing it against the bottom
part of the terminal block so as to avoid a contact with other cables
Refer to the inverter manual for details of Pr 186 CS terminal function selection.
*3 The pin number differs according to the encoder used
*4 Connect the encoder so that there is no looseness between the motor and motor shaft Speed ratio should be 1:1
*5 Earth the shield cable of the encoder cable to the enclosure with a P clip, etc
*6 For the complementary, set the switch to off position
*7 A separate power supply of 5V/12V/15V/24V is necessary according to the encoder power specification
*8 For terminal compatibility of the FR-JCBL, FR-V5CBL and FR-A7AP, refer to the inverter manual or the instruction manual of the FR-A7AP
*9 Assign the function using Pr.178 to Pr.184, Pr.187 to Pr.189 (input terminal function selection).
*10 When position control is selected, terminal JOG function is made invalid and conditional position pulse train input terminal becomes valid
*11 Assign the function using Pr.190 to Pr.194 (output terminal function selection).
Vector control dedicated motor (SF-V5RU), 12V complimentary
10 2 2
3
1
1
Speed limit command Frequency setting potentiometer
1/2W1kΩ
5 (+)
(-)
MCCB R/L1 S/L2 T/L3
*6 *8
*5
PA1 FR-A7AP PA2 PB1 PB2 PZ1 PZ2 PG
PG SD SD
STF STR SD
*3
ON OFF
SF-V5RU
U V W
U
A B C
V W E
G1 G2 A
*4
MCCB
B C D F G S R
IM FAN
Encoer
*1
CS(OH) SD
Inverter
PC 2W1kΩ
12VDC power supply
Three-phase AC power supply
Three-phase AC power supply
Thermal protector
Earth (ground)
Differential line driver
Complimentary
Terminating resistor
External thermal relay input *2
Forward rotation start Reverse rotation start Contact input common
Torque command (±10V)
1 5 (+)
(-)
MCCB R/L1 S/L2 T/L3
*6 *8
*5
PA1 FR-A7AP PA2 PB1 PB2 PZ1 PZ2
Forward stroke end Reverse stroke end Pre-excitation/servo on
Clear signal Pulse train Sign signal
Preparation ready signal
STF STR
LX * 9
CLR *9
CLEAR
JOG *10
NP * 9
*3
OFF
SF-V5RU
U V W
U
A B C
V W E
G1 G2 A
*4
MCCB
B PA1
PA2 PB1 PB2 PZ1 PZ2
C D F G S R
IM FAN
Encoder
*1
CS(OH) SD
Inverter Positioning unit
MELSEQ-Q QD75P1
PC 2W1kΩ
12VDC power supply
PULSE F PULSE R
PULSE COM CLEAR COM
RDY COM
READY
PC
RDY *11
SE
FLS RLS DOG STOP
COM
24VDC power supply
Three-phase AC power supply
Three-phase AC power supply
Earth (ground) Thermal
protector External thermal
relay input *2
Torque limit command
(±10V)
ON
Differential line driver
Complimentary
Terminating resistor
PG PG SD SD
Torque control
Position control
CS(OH)
Resistor (2W1kΩ)
PC Control circuit terminal block
Trang 4Setting dial
(Setting dial: Mitsubishi inverter
dial)
Used to change the
frequency setting and
parameter values.
Operation mode switchover
Used to switch between the PU and external operation mode
When using the external operation mode (operation using a separately connected frequency setting potentiometer and start signal), press this key to
PU: PU operation mode EXT: External operation mode
Monitor(4-digit LED)
Shows the frequency, parameter
number, etc
No function
Monitor indication
Lit to indicate monitoring mode
PU: Lit to indicate PU operation mode.
EXT: Lit to indicate external operation mode.
NET: Lit to indicate network operation mode.
Rotation direction indication
REV: Lit during reverse rotation FWD: Lit during forward rotation
Start command forward rotation Start command reverse rotation
Stop operation
Alarms can be reset
Mode switchover
Used to change each setting mode
Unit indication
(Flicker when the set frequency monitor is
displayed.)
* Energy saving monitor is displayed when the energy saving monitor of Pr 52 is set.
Used to set each setting.
If pressed during operation, monitor changes as below;
Running frequency Output current Output voltage
Operation mode indication
Flickering: When the frequency command is
not given even if the forward/reverse command is given
*
Operation Panel (FR-DU07)
Trang 5Dimension Drawings
Protective Functions
Peripheral Devices
Basic operation
At powering on (external operation mode)
PU operation mode
(output frequency monitor)
Parameter setting mode
PU Jog operation mode
Output current monitor Output voltage monitor
Display the current setting
Value change Value change
Parameter write is completed!!
Parameter and a setting value flicker alternately
all clear
Alarm clear
Parameter copy
(Example)
(Example)
Frequency setting has been written and completed!!
and frequency flicker
[Operation for displaying alarm history]
Past eight alarms can be displayed
(The latest alarm is ended by ".".) When no alarm history exists, is displayed
Operation mode switchover
Trang 6For simple variable-speed operation of the inverter, the initial setting of the parameters may be used as they are Set the necessary parameters to meet the load and operational specifications Parameter setting, change and check can be made from the operation panel (FR-DU07) For details of parameters, refer to the instruction manual.
REMARKS
⋅ indicates simple mode parameters (initially set to extended mode)
⋅ The shaded parameters in the table allow its setting to be changed during operation even if "0" (initial value) is set in Pr.77 Parameter write selection.
Minimum Setting Increments Initial Value
Refer
to Page
Customer Setting
Inverter rated output
Parameter List
Trang 7Dimension Drawings
Protective Functions
Peripheral Devices
51 Second electronic thermal O/L relay 0 to 500A, 9999/
0 to 3600A, 9999 *2
0.01/0.1A
52 DU/PU main display data selection
0, 5 to 14, 17 to 20,
22 to 25, 32 to 35,
50 to 57, 100
54 FM terminal function selection
1 to 3, 5 to 14, 17, 18,
21, 24, 32 to 34, 50, 52, 53
*2
Inverter rated output
0 to 3600A, 9999 *2 0.01A/0.1A *2 9999 50
0 to 8, 13 to 18, 20, 23,
24, 30, 33, 34, 40, 43, 44,
50, 53, 54
Minimum Setting Increments Initial Value
Refer
to Page Customer Setting
Trang 80 to 3600kW, 9999 *2 0.01/0.1kW *2 9999 55
0 to 3600A, 9999 *2
0.01/0.1A
0 to 400mΩ, 9999 *2
0.001Ω/
0 to 400mΩ, 9999 *2
0.001Ω/
0 to 3600mΩ (0 to 400mH), 9999 *2
0.001Ω (0.1mH)/
0.01mΩ(0.01mH)
*2
0 to 3600mΩ (0 to 400mH), 9999 *2
0.001Ω (0.1mH)/
0.01mΩ(0.01mH)
*2
0 to 100Ω (0 to 100%), 9999 *2
0.01Ω (0.1%)/
0.01Ω (0.01%)
*2
115 Thrid stall prevention operation
Minimum Setting Increments Initial Value
Refer
to Page Customer Setting
Trang 9Dimension Drawings
Protective Functions
Peripheral Devices
139 Automatic switchover frequency between inverter and commercial
158 AM terminal function selection 1 to 3, 5 to 14, 17, 18, 21, 24, 32 to 34, 50,
159 Automatic switchover ON range between commercial power-supply and
inverter operation
162 Automatic restart after instantaneous
165 Stall prevention operation level for
tion 166 Output current detection signal
167 Output current detection operation
Minimum Setting Increments Initial Value
Refer
to Page Customer Setting
Trang 10 168
Parameter for manufacturer setting Do not set.
172 User group registered display/batch
178 STF terminal function selection
0 to 20, 22 to 28, 42 to
44, 60, 62, 64 to 71, 9999
179 STR terminal function selection 0 to 20, 22 to 28, 42 to
180 RL terminal function selection
0 to 20, 22 to 28, 42 to
44, 62, 64 to 71, 9999
184 AU terminal function selection 0 to 20, 22 to 28, 42 to
185 JOG terminal function selection
0 to 20, 22 to 28, 42 to
44, 62, 64 to 71, 9999
190 RUN terminal function selection 0 to 8, 10 to 20, 25 to 28,
30 to 36, 39, 41 to 47, 64,
70, 84, 85, 90 to 99,
100 to 108, 110 to 116,
120, 125 to 128, 130 to
136, 139, 141 to 147,
164, 170, 184, 185, 190
to 199, 9999
195 ABC1 terminal function selection
0 to 8, 10 to 20, 25 to 28,
30 to 36, 39, 41 to 47, 64,
70, 84, 85, 90, 91, 94 to
99,
100 to 108, 110 to 116,
120, 125 to 128, 130 to
136, 139, 141 to 147,
164, 170, 184, 185, 190,
191, 194 to 199, 9999
Minimum Setting Increments Initial Value
Refer
to Page Customer Setting
Trang 11Dimension Drawings
Protective Functions
Peripheral Devices
247 Constant-power region slip
262 Subtracted frequency at deceleration
l 275 Stop-on contact excitation current low- speed multiplying factor 0 to 1000%, 9999 0.1% 9999 63
276 PWM carrier frequency at stop-on contact 0 to 9, 9999/0 to 4, 9999
Minimum Setting Increments Initial Value
Refer
to Page Customer Setting
Trang 12284 Deceleration detection function
Minimum Setting Increments Initial Value
Refer
to Page Customer Setting
Trang 13Dimension Drawings
Protective Functions
Peripheral Devices
376 *6 Open cable detection enable/disable
420 *6 Command pulse scaling factor
421 *6 Command pulse scaling factor
424 *6 Position command acceleration/
Minimum Setting Increments Initial Value
Refer
to Page Customer Setting
Trang 140 to 8, 13 to 18, 20, 23,
24, 30, 33, 34, 40, 43, 44,
50, 53, 54, 9999
0 to 3600kW, 9999 *2
0.01kW/0.1kW
0 to 3600A, 9999 *2 0.01/0.1A *2 9999 55
0 to 400mΩ, 9999 *2
0.001Ω/
0 to 400mΩ, 9999 *2
0.001Ω/
460 Second motor constant (L1) 0 to 50Ω (0 to 1000mH), 9999/
0 to 3600mΩ (0 to 400mH), 9999 *2
0.001Ω (0.1mH)/
0.01mΩ(0.01mH)
*2
461 Second motor constant (L2) 0 to 50Ω (0 to 1000mH), 9999/
0 to 3600mΩ (0 to 400mH), 9999 *2
0.001Ω (0.1mH)/
0.01mΩ(0.01mH)
*2
0 to 100Ω (0 to 100%), 9999 *2
0.01Ω (0.1%)/
0.01Ω (0.01%)
*2
463 Second motor auto tuning setting/
464 *6 Digital position control sudden stop
Minimum Setting Increments Initial Value
Refer
to Page Customer Setting
Trang 15Dimension Drawings
Protective Functions
Peripheral Devices
504 Maintenance timer alarm output set
517 S-pattern time at a completion of
519 S-pattern time at a completion of
557 Current average value monitor signal
output reference current
0 to 500/0 to 3600A
*2
0.01/0.1A
*2
Rated inverter current
68
Constant power range torque
Minimum Setting Increments Initial Value
Refer
to Page Customer Setting