Nội dung

Trufisp CineASD not easily seen Contrast Bolus First Pass Exam ASD is easily seen Contrast Bolus First Pass Exam ASD is easily seen Trufisp Cine ASD not easily seen Qp/Qs: Atrial Septal

Trang 1

Flow Imaging

Clinical Cases

Trang 2

Typical Velocities (cm/sec)

Pulmonary Artery 70-130

External Iliac Artery 81 – 120

Common Femoral Artery 115

Superficial Femoral Artery 90

Sagittal Sinus Vein 10

Peripheral Veins 5 – 10

Trang 3

Trufisp Cine

ASD not easily seen

Contrast Bolus

First Pass Exam

ASD is easily seen

Contrast Bolus First Pass Exam

ASD is easily seen

Trufisp Cine

ASD not easily seen

Qp/Qs: Atrial Septal Defect

Dr John Lesser and Dr M Tadavarthy, Abbott Northwestern Hospital, Minneapolis, MN

Trang 4

Flow Imaging is Perpendicular to Main Pulmonary Artery VENC = 150 cm/sec

Flow Imaging is Perpendicular to Aorta VENC = 150 cm/sec

Qp/Qs: Atrial Septal Defect

Trang 5

aorta pulmonary artery

Qp/Qs: Atrial Septal Defect

Trang 6

pulmonary artery

stroke volume

130 ml

net flow

130 ml net flow80 ml

Qp/Qs: Atrial Septal Defect

ascending aorta stroke volume

80 ml

Trang 7

pulmonary artery ascending aorta

• shunt fraction (Qp/Qs ratio) = 131 / 82 = 1.6

• shunt from left atrium to right atrium

• known as systemic to pulmonary shunt

Qp/Qs: Atrial Septal Defect

Trang 8

Pulmonary Outflow Short Axis

Pressure Gradient: Pulmonary Valve Stenotic Jet

Dr John Lesser and Dr M Tadavarthy, Abbott Northwestern Hospital, Minneapolis, MN

Trang 9

1 Truefisp Cine image through pulmonary valve shows the jet.

2 Rephased Flow image with in-plane VENC 500 cm/sec shows the valve.

3 Phase Flow image with in-plane VENC 500 cm/sec shows the jet.

1

Pressure Gradient: Pulmonary Valve Stenotic Jet

Trang 10

4 Orthogonal slice was placed directly through the jet.

5 Truefisp Cine image through pulmonary valve shows the valve & jet.

6 Phase Flow image with in-plane VENC 500 cm/sec shows the jet

4

Pressure Gradient: Pulmonary Valve Stenotic Jet

Trang 11

• Flow Imaging of Stenotic Jet with Inplane VENC 400 cm/sec

• Agrees with Peak Velocity of 400 cm/sec Measured at Cardiac Catheterization

Trang 12

Flow Imaging with Through-plane VENC

of 150 cm/sec has

aliasing (must raise VENC)

Regurgitant Fraction: Aortic Valve Insufficiency

Dr John Lesser and Dr M Tadavarthy, Abbott Northwestern Hospital, Minneapolis, MN

TrueFisp Cine Imaging

of Aortic Valve

Trang 13

VENC -150 to +150 cm/sec has aliasing (before VENC Adjustment, peak velocity 144 wrong)

Regurgitant Fraction: Aortic Valve Insufficiency

Trang 14

VENC –130 to +170 cm/sec has NO aliasing (after VENC Adjustment, peak velocity 167 correct)

Regurgitant Fraction: Aortic Valve Insufficiency

Trang 15

regurgitant fraction = 25 / 101 = 25%

stroke volume = 76 ml

Regurgitant Fraction: Aortic Valve Insufficiency