Shop manual máy đào HuynDai R170W-9 (Phần 5) Phần hệ thống cơ điện tử
Trang 1GROUP 7 ENGINE OVERHEAT PREVENTION SYSTEM
Main control valve
Engine
Main pump — Pilot pump
Pump power
shift EPPR
Emergency
warning lamp
Cluster
Hydraulic temp sensor
Accel dial
Hydraulic temperature warning lamp
14W95MS09
1 lf the engine coolant temperature or the hydraulic oil temperature is overheated over 100°C, the warning lamp is ON and the pump input torque or the engine speed is reduced as below logic table
2.LOGIC TABLE
Description Condition Function
Activated |" Coolant or hydraulic oil temperature : |- Warning lamp & buzzer : ON
First step Above 100°C - Pump absorption torque is reduced
warning Canceled - Coolant or hydraulic oil temperature :|- Return to pre-set the pump absorption
Less than 95°C torque
- Emergency warning lamp pops up on the
center of LCD and the buzzer sounds
- Engine speed is reduced after 10 seconds
- Coolant or hydraulic oil temperature :
Activated Above 105°C
Second step
warning - Return to pre-set the engine speed
- Coolant or hydraulic oil temperature : ;
Canceled Less than 100°C Hold pump absorption torque on the first
step warning
5-10