BẢN VẼ CÁC CHI TIẾT ĐIỂN HÌNH- KC SÀN LIÊN HỢP

1 194 2

Đang tải... (xem toàn văn)

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 1
Dung lượng 360,09 KB

Các công cụ chuyển đổi và chỉnh sửa cho tài liệu này

Nội dung

Bản vẽ chi tiết điển hình trong kết cấu dầm sàn liên hợp bê tông cốt thép.

Trang 1

RIB

NOTES:

1

2

3

4

5

STUDS 3/4 " DIA UNO

LONGITUDINAL SPACING=4 1/2 " (MIN) TRANSVERSE SPACING=3" (MIN) MAXIMUM SPACING=24" (REQUIRES A PLUG WELD WHEN STUD SPACING EXCEEDS 16")

USE ONLY ONE STUD PER RIB UNTIL

NO OF STUDS EXCEEDS DECK RIBS AVAILABLE

3 STUDS AS SHOWN ARE MAX NUMBER ALLOWABLE PER DECK RIB

MAX CONDUIT DIA=1/3xT 3/4"

MIN SPA

ACHIEVE MIN SPA W/ DISTANCE SPECIFIED

CONDUITS ENTERING SLAB, SEE ELEC WHERE DIM EXCEEDS

MIN SPA OF CONDUIT

1 3xCONDUIT DIA (3/4" MIN.)

2 ONE CONDUIT PER DECK RIB

DECK SPAN

GIRDER GIRDER

1

2

3 CONTINUE ALL SLAB REINF THROUGH CONSTRUCTION JOINT

JOINTS PARALLEL TO PURLINS SHALL BE LOCATED BETWEEN PURLIN ALONG GRID AND FIRST ADJACENT PURLIN

JOINT LOCATIONS AS INDICATED ARE INTENDED TO ENSURE THAT CAMBER IS REMOVED PRIOR TO COMPOSITE ACTION OF CONCRETE &

STEEL ALTERNATE LOCATIONS SHALL BE REVIEWED BY ENGINEER

NOTES:

EXTENT OF CONCRETE POUR (100’-0" MAX.)

SEE PLAN

L BM C

TSE SEE PLAN

SEE PLAN 8" MAX

0 1’ 2’ 3’

L BM C

TSE SEE PLAN

SEE PLAN

2’-0"

4 SCALE 3/4"=1’-0"

TYP COMPOSITE SLAB EDGE DETAIL

(1) #4 CONT

3/4"

CLR

TSE SEE PLAN

DRAPE MESH BETWEEN BEAMS TYP

SUPPORT MESH ON CHAIRS TYP

0 1’ 2’ 3’

SEE PLAN

5 SCALE 3/4"=1’-0"

TYP COMPOSITE DETAIL

TSE SEE PLAN

COMPOSITE BEAM SEE PLAN

#4x4’-0" @ 18"0.C

OVER GIRDERS SUPPORT BARS

ON CHAIRS

2"MIN BRG LAP

0 1’ 2’ 3’

6 SCALE 3/4"=1’-0"

TYP GIRDER DETAIL

TSE SEE PLAN

COMPOSITE BEAM SEE PLAN

0 1’ 2’ 3’

7 SCALE 3/4"=1’-0"

TYP COLUMN CONNECTION DETAIL

3 NO SCALE

CONSTRUCTION JOINT LAYOUT COMPOSITE SLAB

NO SCALE

WITHIN COMPOSITE SLAB

PLACEMENT OF HEADED STUDS 2

1 NO SCALE

PLACEMENT OF ELECTRICAL WITHIN COMPOSITE SLAB

SEE PLAN TSE

SEE PLAN

0 1’ 2’ 3’

8 SCALE 3/4"=1’-0"

DETAIL

EXTERIOR WALL, SEE ARCH

DECK DIRECTION VARIES SEE PLAN 3/16 4

0 1’ 2’ 3’

0 1’ 2’ 3’

10 SCALE 3/4"=1’-0"

DETAIL

11 SCALE 3/4"=1’-0"

DETAIL

SINGLE PL CONN @ PURLIN, SEE 9/S521

DOUBLE ANGLE CONN

BEAM

NOTE: COMPOSITE SLAB AND DECK NOT SHOWN FOR CLARITY

9 SCALE 3/4"=1’-0"

DETAIL

0 1’ 2’ 3’

SEE PLAN TBE

TSE SEE PLAN

CMU WALL, SEE WALL ELEVATIONS FOR REINF

DOUBLE ANGLE CONNECTION, SEE 6/S521

SEE PLAN TSE

CMU WALL, SEE WALL ELEVATIONS FOR REINF

UNIFORMLY PLACE EQ NO’S OF STUDS EA SIDE OF BEAM CL (PURLIN) OR PLACE UNIFORMLY BETWEEN BEAM CL’S AS SHOWN ON PLAN (GIRDER)

WHEN DOUBLING OR TRIPLING OF STUDS IN DECK RIBS BECOMES NECESSARY, BEGIN FROM EA END OF THE BEAM & PROCEED TOWARDS THE CENTER OF THE BEAM SPAN

0 1’ 2’ 3’

12 SCALE 3/4"=1’-0"

DETAIL

SEE PLAN

SEE PLAN TSE

JBE VARIES

ROOF DECK

2-12 3/16

3/16 2-12

BEAM

L3x3x1/4 CONT

SEE PLAN TBE

TBE SEE PLAN

0 1’ 2’ 3’

13 SCALE 3/4"=1’-0"

DETAIL

4 SIDES

1/4

1/4

1/4

L6x6x3/8x0’-6"

HSS GIRT

BEAM DECK ANGLE, SEE 12/S513 (NO ANGLE AT SIM)

0 1’ 2’ 3’

14 SCALE 3/4"=1’-0"

DETAIL

SEE PLAN JBE

1/2 "

END OF DECK BEYOND

COLUMN

BEAM DBL ANGLE CONN,

SEE 6/S521

SINGLE PLATE CONN SEE 7/S521

EMBED PL EP-5, SEE SCHED ON SHEET S601

3@12

SLAB EDGE, SEE PLAN AND 4/S513

ROOF DECK NOTCH

AT COL

HSS2 1/2 x2 1/2 x 3/16 x0’-4"

SPACER AT COL

3"

1/4

L6x4x 5/16 (LLV) CONT

S513 9A

9A SCALE 3/4"=1’-0"

DETAIL

SEE PLAN TBE

BEAM

COLUMN 2" 2"

COLUMN CONT @ GRID 5

2-12 3/16

BOLTED JOIST CONN (GC TO COORD BOLT HOLES W/ STEEL SUPPLIER)

1/4

PL 3/4 x7 1/2"x1’-2"

W/ (4) 3/4" DIA BOLTS

(2) #4 CONT @ SLAB EDGE

(2) #4 CONT @ SLAB EDGE

T/O EP=TBE

STIFF PL EA SIDE, SEE 5/S521

PL 3/4x6x1’-6" W/

(2) 3/4 " DIA BOLTS (WELD BEAM TO CAP PL AFTER INSTALLATION)

BASE PL, SEE 9/S513

FITTED STIFFENER PL

5/16 " BENT PL W/

1/2 " DIAx6" STUDS @ 12" OC (SHORE WHEN LONGER THAN 1’-4")

WF COLUMN

AT SIM

3/8 " FITTED STIFF PL, SEE 5/S521

’FLUSH’ EMBED PL EP-1 @ 2’-8" OC, SEE SCHED ON SHEET S601

BENT PL 3/8x4x0’-5 7/8 " CONT

SEE 4/S513

L6x6x3/8x0’-8"

AT EA JOIST LOC

A B C D E

F

* * * S A F E T Y P A Y S * * *

* * * S U P P O R T V A L U E E N G I N E E R I N G - I T P A Y S * * *

Louisville District

of Engineers

US Army Corps

SHEET REFERENCE NUMBER:

CERTIFIED FINAL DESIGN