The dilute sulfuric acid electrolyte is absorbed by separators and plates and thus immobilized.. Battery Construction Component Positive plate Negative plate Container Cover Safety valve

Trang 1

6V 225Ah(10hr) 31

The rechargeable batteries are lead-lead dioxide systems The dilute sulfuric acid electrolyte

is absorbed by separators and plates and thus immobilized Should the battery be accidentally overcharged producing hydrogen and oxygen, special one-way valves allow the gases to escape thus avoiding excessive pressure build-up Otherwise, the battery is completely sealed and is, therefore, maintenance-free, leak proof and usable in any position

Battery Construction

Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte

General Features

for efficient gas recombination of up to 99% and freedom from electrolyte maintenance or water adding

ƽ Not restricted for air transport-complies with IATA/ICAO Special Provision A67

ƽ Can be mounted in any orientation

ƽ Computer designed lead, calcium tin alloy grid for high power density

ƽ Long service life, float or cyclic applications

ƽ Maintenance-free operation

ƽ Low self discharge

Dimensions and Weight

Performance Characteristics

Nominal Capacity 77oF(25oC)

Internal Resistance

Self-Discharge 3% of capacity declined per month at 20oC(average) Operating Temperature Range

Charge Methods: Constant Voltage Charge 77oF(25oC) Maximum charging current 67.5A

Discharge Constant Current (Amperes at 77 o F25 o C)

Discharge Constant Power (Watts at 77 o F25 o C)

page1 of 2

www.vision-batt.com

(Note)The above characteristics data are average values obtained within three charge/discharge cycles not the mimimum values

End Point Volts/Cell

1.60V 1.65V 1.70V 1.75V 1.80V

End Point Volts/Cell

3FM225D-X

Cycle use 2.30-2.35VPC

Standby use 2.23-2.27VPC

Trang 2

3FM225D-X 6V 225Ah

THE INTERNATIONAL CERTIFICATION NETWORK

ISO9001:2000

THE INTERNATIONAL CERTIFICATION NETWORK

www.vision-batt.com

Shenzhen Center Power Tech Co., Ltd.

Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China

Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail: sales@vision-batt.com

Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2011-8)

Page 2 of 2

Self-discharge characteristic

Life characteristics of Standby use Cycle service life in relation to depth of discharge

Temperature effects on float life Temperature effects on capacity

Storage time: months

o Temperature( C)

Charging time (hours)

Constant voltage charging

o

characteristic (0.25CA,25 C)

Relationship between

charging voltage and temperature

o Ambient temperature( C)

Testing conditions: floating voltage: 2.27 to 2.30V/Cell

ambient temperature: 25℃ (77 O F)

0

40

20

60

80

100

120

2.30V/Cell

0

15

5

0.2C 1.0C

Temperature (℃) -10

40 20 0 -20

100 80 60

10

0 20

0.1C

120

40

30 50

80

20 0

40 60

100 120

1400 400

100% D.O.D 50% D.O.D.

1000

800 1200

% Depth of discharge 30

1600

0 40 50 60 70 80 90 100 110

2 4 6 8 10 12 14 16 18 20

STAND B

Y USE

CYCLE USE

7.8

7.5

7.2

6.9

6.6

-10 0 10 20 30 40 50 60

60

0.05 0.10 0.15

0 20 40

0 0 2 4 6 8

6.0 5.5 6.5 0.20 0.25 140

80 100 120

Charged Volume

(%)

7.0 7.5

(V)

(xCA)

CHARGE CURRENT 10

CHARGE VOLTAGE

12 14 16 18 20

CHARGED VOLUME

O

Discharge characteristic (25 C)

Discharge time

22.5A 39.2A 56.4A 147A 225A