1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Encyclopedia of Smart Materials (Vols 1 and 2) - M. Schwartz (2002) Episode 3 pps

80 249 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 80
Dung lượng 1,19 MB

Các công cụ chuyển đổi và chỉnh sửa cho tài liệu này

Nội dung

PIEZOELECTRIC AND ELECTROSTRICTIVE EFFECTS IN CERAMIC MATERIALS Piezoelectricity, first discovered in Rochelle salt by Jacques and Pierre Curie, is the term used to describe the ability

Trang 2

0 100 200 300 4000

102030

Figure 13 Time course of the EOT (neffl) of a p-type PSi chip

etched at 440 mA/cm 2 , oxidized by ozone for 20 min, and

function-alized as shown in Scheme 2 a The arrow labeled A identifies the

addition of 10µM streptavidin preincubated in 1 mM biotin

dis-solved in PBS buffer, pH 7.4 (control); B addition of 10µM

strepta-vidin without biotin (washing cycles in between); C washing cycles

with buffer; D addition of dithiothreitol, which was used to reduce

the disulfide bridge and therefore release the bound protein–linker

complex The sample was mounted in a flow cell using a constant

flow rate of 0.5 mL/min [reprinted with permission from (59)].

the silicon walls Using an ethanol–water mixture

in-stead of the protein solution results in a rectangular

sig-nal response upon adding the mixture and rinsing with

water

Specific binding of streptavidin to the

biotin-func-tionalized PSi matrix was measured by monitoring the

changes in EOT time-resolved in a PBS buffer containing

Figure 14 Binding curve (change in

EOT) on a PSi surface functionalized as

shown in Scheme 2b Sequential

addi-tion of streptavidin (1 mg/mL),

biotin-ylated protein A (2.5 mg/mL), and

human IgG (2.5 mg/mL) Reversible

binding of IgG was demonstrated by

binding of IgG followed by a pH-induced

release and a second binding of IgG

to the immobilized protein A layer

[reprinted with permission from (60)].

01020304050607080

t (nm)

Streptavidin b-Protein A IgG Rinse IgG Rinse

As expected, specific binding of streptavidin to thebiotin-derivatized porous layer resulted in an increase inthe measured effective optical thickness The change in theEOT is due to binding of proteins that have a higher refrac-

in the pores and is in direct quantitative agreement withwhat was expected from effective medium approximations

23 nm In a control experiment, in which all streptavidinbinding sites were deactivated by saturating them withbiotin in solution, a change in EOT was not observed, sug-gesting that there is little or no nonspecific protein adsorp-tion to the PSi matrix Rinsing the surface with buffer afterthe protein has bound does not alter the EOT significantly.However, because the biotin recognition element is linked

to the surface via a disulfide bond, the protein–ligand plex could be released from the surface by adding dithio-threitol to the bulk phase The initial red shift of 23 nmupon binding streptavidin to the biotinylated PSi can becompletely reversed and provides further support for theinterpretation that the observed red shift is due to specificbinding of the protein to the functionalized surface More-over, the reversible linkage of the proteins via disulfidebridges to the surface offers the possibility of reusing thefunctionalized PSi chips for further binding experiments.Sailor and co-workers bound protein A to the PSi surfacethrough the BSA-containing linker (60,61) Streptavidinbinds to the biotin-terminated linker and adds three acces-sible free biotin-binding sites to the surface (Fig 14).Adding a solution of biotinylated protein A results inattaching it to the surface This prefunctionalized surfacecan be used for binding studies of aqueous human IgG Theobserved change in EOT for binding IgG required severalminutes to reach a steady-state value, presumably due toslow diffusion of this large molecule into the pores of thePSi film The proteinA/IgG complex was partly dissociated

com-by rinsing with buffer and completely dissociated com-by a pHswitch to a low pH Protonation of the binding sites on

Trang 3

protein A by decreasing the pH of the solution releases

IgG from protein A A second binding of IgG after its

re-lease can be demonstrated that shows the reproducibility

of the method The incorporation of BSA in the linker

of-fered two advantages Due to the increased hydrophilicity

of the chemically modified PSi, surface nonspecific

adsorp-tion was not observed, and the addiadsorp-tion of detergent in the

buffer was no longer necessary A second reason for

incor-porating BSA in the linker was to separate binding sites in

the PSi films Sailor and co-workers (61) found that without

BSA the sensor did not scale with the mass of analyte, as

was expected, assuming the same refractive index for all

proteins investigated Larger analytes were consistently

underestimated, indicating crowding of binding sites at the

surface The insertion of BSA in the linker avoided

crowd-ing and thus, the sensor scaled with the analyte mass above

20 kDa (60)

Optical Transduction—Ellipsometry

Optical biosensing is usually based on the interaction

of light with biomolecules Techniques such as surface

plasmon resonance and ellipsometry have focused mostly

on interactions on a macromolecular scale, for example,

antigen–antibody and nucleic acid interactions The optical

detection of small molecules (0.2–2 kDa) that have

biologi-cal receptors is much more difficult due to their small

change in EOT Mandenius and co-workers (64)

demon-strated the advantage of using oxidized PSi as a surface

enlargement for binding small receptor molecules such as

biotin or small peptides They used p-type silicon that had

samples were thermally oxidized to stabilize the porous

structure The PSi surface was functionalized by using

streptavidin, either physisorbed on the silica surface or

cross-linked via glutardialdehyde Streptavidin adsorption

monitored by ellipsometry showed a 10-fold larger

re-sponse compared to a planar surface However, the rate of

adsorption was one order of magnitude lower, probably due

to the long diffusion time of the protein within the pores

Theoretically, the refractive index and the thickness of a

thin layer can be calculated from the measured

parame-tersψ (the ratio of the amplitude change of light polarized

(the phase shift) For PSi, however, the microstructure of

the porous layer is very complicated, and a simple optical

model that allowing quantifying film thickness and surface

concentration is not straightforward to define Therefore,

direct measure of analyte binding without quantification

Using this setup, they detected binding of biotin and an

re-sponse time of 30 s for the oligopeptide at a concentration

CONCLUSIONS

Porous silicon based biosensors may add a new dimension

to conventional technologies due to their unique optical and

electronic properties Tunable properties such as pore size,

porosity, dielectric function, and thickness render poroussilicon a versatile matrix for biological compounds that act

as the receptive layer for molecular recognition of analytes

in solution Interferometry has been successfully employed

to detect changes in the effective optical thickness upon sorption of molecules on the pore walls The large surfacearea of porous silicon that displays a spongelike appear-ance or exhibits ordered cylindrical pores provides a quasithree-dimensional space that increases the signal-to-noiseratio of many transducing principles

ad-BIBLIOGRAPHY

1 A Uhlir, Bell Syst Tech J 35: 333–347 (1956).

2 L Canham, Appl Phys Lett 57: 1046–1048 (1990).

3 V Parkhutik, Solid-State Electron 43: 1121–1141 (1999).

4 M.I.J Beale, J.D Benjamin, M.J Uren, N.G Chew, and A.G.

Cullis, J Cryst Growth 73: 622–636 (1985).

5 R.L Smith and S.D Collins, J Appl Phys 71: R1–R22

8 S.J Gregg and K.S.W Sing, Adsorption, Surface Area and

Porosity Academic Press, NY, 1982.

9 D Brumhead, L.T Canham, D.M Seekings, and P.J Tufton,

Electrochim Acta 38: 191–197 (1993).

10 W Theiss, Surf Sci Rep 29: 91–192 (1997).

11 R Herino, in Properties of Porous Silicon, Vol Datareview Ser.

No 18, L.T Canham, ed., London, 1997, pp 89–96.

12 C Kittel, Introduction to Solid State Physics J Wiley, NY,

1996.

13 L.T Canham, in Properties of Porous Silicon, Vol Datareview

Ser No 18, L.T Canham, ed., London, 1997, pp 249–255.

14 F Kozlowski, P Steiner, and W Lang, J Luminescence 57:

163–167 (1993).

15 H Mizuno, H Koyama, and N Koshida, Appl Phys Lett 69:

3779–3781 (1996).

16 S.G Lipson, H Lipson, and D.S Tannhauser, Optical Physics.

Cambridge University Press, Cambridge, 1995.

17 G L´erondel and R Romestain, Thin Solid Films 297: 114–117

22 J.E Lee, T.W Bitner, J.S Ha, M.J Shane, and M.J Sailor,

J Am Chem Soc 118: 5375–5382 (1996).

23 N.Y Kim and P.E Laibinis, Mater Res Soc Symp Proc 536:

167–172 (1999).

24 N.Y Kim and P.E Laibinis, ACS Symp Ser 727: 157–168

(1999).

25 J.M Buriak, Chem Commun 1051–1060 (1999).

26 T Dubois, F Ozanam, and J.-N Chazaviel, Proc Electrochem.

Soc 97: 296–310 (1997).

Trang 4

27 C Vieillard, M Warntjes, F Ozanam, and J.-N Chazalviel,

Proc Electrochem Soc 95: 250–258 (1996).

28 N.Y Kim and P.E Laibinis, J Am Chem Soc 120: 4516–4517

(1998).

29 J.H Song and M.J Sailor, J Am Chem Soc 120: 2376–2381

(1998).

30 J.H Song and M.J Sailor, Inorg Chem 38: 1498–1503 (1999).

31 J.M Holland, M.P Stewart, M.J Allen, and J.M Buriak,

J Solid State Chem 147: 251–258 (1999).

32 J.M Buriak and M.J Allen, J Am Chem Soc 120: 1339–1340

(1998).

33 J.M Buriak, M.P Stewart, T.W Geders, M.J Allen, H.C Choi,

J Smith, D Raftery, and L.T Canham, J Am Chem Soc 121:

38 V Petrova-Koch, T Muschik, A Kux, B.K Meyer, F Koch, and

V Lehmann, Appl Phys Lett 61: 943–945 (1992).

39 V.M Dubin, C Vieillard, F Ozanam, and J.-N Chazalviel,

Phys Status Solidi B 190: 47–52 (1995).

40 R.C Anderson, R.S M ¨uller, and C.W Tobias, J Electrochem.

43 A Bansal, X Li, I Lauermann, N.S Lewis, S.I Yi, and W.H.

Weinberg, J Am Chem Soc 118: 7225–7226 (1996).

44 J Harper and M.J Sailor, Anal Chem 68: 3713–3717

(1996).

45 S Content, W.C Trogler, and M.J Sailor, Chem Eur J 6:

2205–2213 (2000).

46 S.E Letant, S Content, T.T Tan, F Zenhausern, and M.J.

Sailor, Sensors and Actuators B 69: 193–198 (2000).

47 L Zhang, J.L Coffer, J Wang, C.D Gutsche, J.-J Chen, and

O Zhyan, J Am Chem Soc 118: 12840–12841 (1996).

48 S.E Letant and M.J Sailor, Adv Mater 12: 355–359 (2000).

49 R.C Anderson, R.S Muller, and C.W Tobias, Sensors and

Actuators A 21–A 23: 835–839 (1990).

50 M.P Stewart and J.M Buriak, Adv Mater 12: 859–869 (2000).

51 N.F Starodub, L.L Fedorenko, V.M Starodub, S.P Dikij,

and S.V Svechnikow, Sensors and Actuators B 35–36: 44–47

(1996).

52 N.F Starodub and V.M Starodub, Proc Electrochem Soc 98:

185–191 (1998).

53 V.M Starodub, L.L Fedorenko, A.P Sisetskiy, and N.F.

Starodub, Sensors and Actuators B 58: 409–414 (1999).

54 M Thust, M.J Sch¨oning, S Frohnhoff, R Arens-Fischer,

P Kordos, and H L ¨uth, Meas Sci Technol 7: 26–29 (1996).

55 M Thust, M.J Sch¨oning, P Schroth, U Malkoc, C.I Dicker,

A Steffen, P Kordos, and H L ¨uth, J Mol Catal B: Enzym.

7: 77–83 (1999).

56 H L ¨uth, M Steffen, P Kordos, and M.J Sch¨oning, Mater Sci.

Eng B 69–70: 104–108 (2000).

57 M.J Sch¨oning, F Ronkel, M Crott, M Thust, J.W Schultze,

P Kordos, and H L ¨uth, Electrochim Acta 42: 3185–3193

J Am Chem Soc 120: 12108–12116 (1998).

60 K.-P.S Dancil, D.P Greiner, and M.J Sailor, J Am Chem Soc.

64 D van Noort, S Welin-Klintstr¨om, H Arwin, S Zangooie, I.

Lundstr¨om, and C.-F Mandenius, Biosensors and

Bioelectron-ics 13: 439–449 (1998).

Trang 5

In a rapidly developing world, the use of smart materials

becomes increasingly important when executing

sophis-ticated functions within a designed device In a common

definition (1), smart materials differ from ordinary

mate-rials because they can perform two or several functions,

sometimes with a useful correlation or feedback

mecha-nism between them For piezoelectric or electrostrictive

materials, this means that the same component may be

used for both sensor and actuator functions

Piezoelec-tric/electrostrictive sensors convert a mechanical variable

(displacement or force) into a measurable electrical

quan-tity by the piezoelectric/electrostrictive effect Alternately,

the actuator converts an electrical signal into a useful

displacement or force Typically, the term transducer is

used to describe a component that serves actuator

(trans-mitting) and sensor (receiving) functions Because

piezo-electrics and electrostrictors inherently possess both direct

(sensor) and converse (actuator) effects, they can be

consid-ered smart materials The degree of smartness can vary

in piezoelectric/electrostrictive materials A merely smart

material (only sensor and actuator functions) can often be

engineered into a “very smart” tunable device or further,

into an “intelligent structure” whose sensor and actuator

functions are intercorrelated with an integrated

process-ing chip

Recent growth in the transducer market has been

rapid and, it is predicted will continue on its current

pace through the turn of the century The sensor market

alone rose to $5 billion in 1990, and projections are

$13 billion worldwide by the year 2000 and an 8% annual

growth rate during the following decade (2) Piezoelectric/

electrostrictive sensors and actuators comprise a

signifi-cant portion of the transducer market There is a growing

trend due especially to automobile production, active

vibration damping, and medical imaging In this article,

the principles of piezoelectric/electrostrictive sensors and

actuators are considered along with the properties of the

most useful materials and examples of successful devices

PIEZOELECTRIC AND ELECTROSTRICTIVE EFFECTS

IN CERAMIC MATERIALS

Piezoelectricity, first discovered in Rochelle salt by Jacques

and Pierre Curie, is the term used to describe the ability of

certain crystals to develop an electric charge that is directly

proportional to an applied mechanical stress (Fig 1a) (3).Piezoelectric crystals also show the converse effect: theydeform (strain) proportionally to an applied electric field(Fig 1b) To exhibit piezoelectricity, a crystal should belong

to one of the twenty noncentrosymmetric crystallographicclasses An important subgroup of piezoelectric crystals isferroelectrics, which possess a mean dipole moment perunit cell (spontaneous polarization) that can be reversed

by an external electric field Above a certain temperature(Curie point), most ferroelectrics lose their ferroelectricand piezoelectric properties and become paraelectrics, that

is, crystals that have centrosymmetric crystallographicstructures do not spontaneously polarize Electrostriction

is a second-order effect that refers to the ability of all rials to deform under an applied electrical field The phe-nomenological master equation (in tensor notation) thatdescribes the deformations of an insulating crystal sub-jected to both an elastic stress and an electrical field is

mate-x i j = s i jkl X kl + d mi j E m + M mni j E m E n ,

i , j, k, l, m, n = 1, 2, 3, (1)

M mni j are the electrostrictive moduli, and E m and E n arethe components of the external electrical field Here, theEinstein summation rule is used for repeating indexes.Typically, the electrostriction term (∝ Em E n) is more than

an order of magnitude smaller than the piezoelectric term

in Eq (1), that is, the electrostrictive deformations aremuch smaller than the piezoelectric strains In this case,under zero stress, Eq (1) simply transforms to

x i j ≈ d mi j E m , i, j, m = 1, 2, 3. (2a)

relationship in matrix notation (4) expressed as

x i ≈ d mi E m , m = 1, 2, 3,

i = 1, 2, 3, 4, 5, 6,

(2b)

perpen-dicular to the crystal axis resulting from application ofthe electrical field Equations (2a) and (2b) describe theconverse piezoelectric effect where the electrical fieldinduces a change in the dimensions of the sample (Fig 1b).The piezoelectric effect is absent in centrosymmetricmaterials, and the elastic strain is due only to electrostric-tion In ferroelectric crystals that have a centrosymmetricparaelectric phase, the piezoelectric and electrostrictioncoefficients can be described in terms of their polarizationand relative permittivity For example, when the electricalfield and deformation are along the orthogonal axis in a

139

Trang 6

−Voltage

+

−Charge

ForceP

Figure 1 Schematic representations of the direct and converse

piezoelectric effect: (a) an electric field applied to the material

changes its shape; (b) a stress on the material yields an electric

field across it.

described in matrix notation as follows (5):

M11 = Q11(ε0ε33)2, (3b)

electrostriction coefficient, which couples longitudinal

strain and polarization (in matrix notation), as described

by the general electrostriction equation,

In matrix notation, the mathematical definition of the

direct piezoelectric effect, where applied elastic stress

causes a charge to build on the major surfaces of the

piezo-electric crystal, is given by

P i = d i j X j , = 1, 2, 3,

where P iis the component of electrical polarization In

elec-trostriction (centrosymmetric crystals), no charge appears

on the surface of the crystal upon stressing Therefore, the

converse electrostriction effect is simply a change of the

inverse relative permittivity under mechanical stress:



1

ε0ε33



The piezoelectric and electrostrictive effects were

de-scribed for single crystals in which spontaneous

polari-zation is homogeneous A technologically important class

of materials is piezoelectric and electrostrictive ceramics,

that consist of randomly oriented grains, separated by

grain boundaries Ceramics are much less expensive to

process than single crystals and typically offer

compa-rable piezoelectric and electrostrictive properties The

piezoelectric effect of individual grains in nonferroelectric

P

PE

Figure 2 Schematic of the longitudinal (a), transverse (a) and

shear deformations (b) of the piezoelectric ceramic material under

an applied electric field.

ceramics is canceled by averaging across the entire ple, and the whole structure has a macroscopic center

sam-of symmetry that has negligible piezoelectric properties.Only electrostriction can be observed in such ceramics Sin-tered ferroelectric ceramics consist of regions that have dif-ferent orientations of spontaneous polarization—so-calledferroelectric domains Domains appear when a material

is cooled through the Curie point to minimize the static and elastic energy of the system Domain boundaries

electro-or domain walls are movable in an applied electric field,

so the ferroelectric can be poled For example, domainsbecome oriented in a crystallographic direction closest tothe direction of the applied electric field Typically, poling isperformed under high electric field at an elevated tempera-ture to facilitate domain alignment As a result, an initiallycentrosymmetric ceramic sample loses its inversion cen-

three independent piezoelectric coefficients: d33, d31, and

defor-mations, respectively, to the applied electric field (Fig 2).Other material coefficients that are frequently used tocharacterize the piezoelectric properties of ceramics are the

piezoelectric voltage coefficients g i j, which are defined inmatrix notation as

where E iare components of the electric field that arise from

external stresses X j The piezoelectric charge d i jand

volt-age g i jcoefficients are related by the following equation:

Trang 7

An important property of piezoelectric and

electrostric-tive transducers is their electromechanical coupling

piezoelectric material in converting electrical energy into

mechanical energy and vice versa Energy conversion is

never complete, so the coupling coefficient is always less

than unity

MEASUREMENTS OF PIEZOELECTRIC

AND ELECTROSTRICTIVE EFFECTS

Different means have been developed to characterize the

piezoelectric and electrostrictive properties of ceramic

ma-terials The resonance technique involves measuring

char-acteristic resonance frequencies when a suitably shaped

specimen is driven by a sinusoidal electric field To a first

approximation, the behavior of a poled ceramic sample

close to its fundamental resonance frequency can be

rep-resented by an equivalent circuit, as shown in Fig 3a The

schematic behavior of the reactance of the sample as a

function of frequency is shown in Fig 3b The equations

used to calculate the electromechanical properties are

de-scribed in the IEEE Standard on piezoelectricity (6) The

simplest example of a piezoelectric measurement by the

resonance technique can be shown by using a ceramic rod

(typically 6 mm in diameter and 15 mm long) poled along

this configuration is expressed as a function of the

funda-mental series and parallel resonance frequencies fsand fp,

Frequencyy

fa

frL

Figure 3 (a) Equivalent circuit of the piezoelectric sample near

its fundamental electromechanical resonance (top branch

repre-sents the mechanical part and bottom branch reprerepre-sents the

elec-trical part of the circuit); (b) elecelec-trical reactance of the sample as

a function of frequency.

respectively:

k33 = (π/2)( fs/fp) tan[(π/2)( fp − fs)/2]. (10)

cal-culated using k33, the elastic compliance s33, and the frequency relative permitivityε33:

low-d33 = k33(ε33s33)1/2 (11)Similarly, other coupling coefficients and piezoelectricmoduli can be derived using different vibration modes

of the same ceramic sample The disadvantage of theresonance technique is that measurements are limited tospecific frequencies determined by the electromechanicalresonance Resonance measurements are difficult for elec-trostrictive samples due to the required application of astrong dc bias field to induce a piezoelectric effect in re-laxor ferroelectrics (see next section of the article).Subresonance techniques are often used to evaluate thepiezoelectric properties of ceramic materials at frequenciesmuch lower than their fundamental resonance frequencies.These include the measurement of piezoelectric chargeupon the application of a mechanical force (direct piezoelec-tric effect) and the measurement of electric-field-induceddisplacement (converse piezoelectric effect) when an elec-tric field is introduced It has been shown that piezoelectriccoefficients obtained by direct and converse piezoelectriceffects are thermodynamically equivalent

The electrostrictive properties of ceramics are easily termined by measuring displacement as a function of the

de-electric field or polarization Thus the M and Q

electrostric-tive coefficients can be evaluated according to Eqs (1) and(4), respectively As an alternative, Eqs (3b) and (6) canalso be used for electrostriction measurements

A direct technique is widely used to evaluate the sensorcapabilities of piezoelectric and electrostrictive materials

at sufficiently low frequencies Mechanical deformationscan be applied in different directions to obtain differentcomponents of the piezoelectric and electrostrictive ten-sors In the simplest case, metal electrodes are placed onthe major surfaces of a piezoelectric sample normal to itspoling direction (Fig 1b) Thus, the charge produced onthe electrodes with respect to the mechanical load is pro-

The charge can be measured by a charge amplifier using

an etalon capacitor in the feedback loop Details of directpiezoelectric measurements can be found in a number oftextbooks (7)

Electric-field-induced displacements can be measured

by a number of techniques, including strain gauges, ear variable differential transformers (LVDT), the capaci-tance method, fiber-optic sensors, and laser interferome-try Metal wire strain gauges are the most popular sensors

perform the measurement, the strain gauge is glued to theceramic sample, and the resistance of the gauge changesaccording to its deformation The resistance variation ismeasured by a precise potentiometer up to a frequency ofseveral MHz However, several gauges need to be used toobtain a complete set of piezoelectric and electrostrictivecoefficients of the sample

Trang 8

Secondarycoils

Primarycoil

Vin

Vout

Figure 4 Principle of the linear variable differential transformer

(LVDT) used for measuring electric-field-induced deformations in

a piezolectric sample.

Figure 4 illustrates the design of an LVDT The

mov-ing surface of the sample is attached to the magnetic core

inserted into the center of the primary and secondary

elec-tromagnetic coils The change of the core position varies

the mutual inductance of the coils An ac current supplies

the primary coil, and the signal in the secondary coils is

proportional to the displacement of the core The response

speed depends on the frequency of the ac signal and the

mechanical resonance of the coil, which typically does not

exceed 100 Hz Generally the resolution is sufficiently high

of turns

The capacitive technique for strain measurements is

based on the change of capacitance in a parallel-plate

ca-pacitor that has an air gap between two opposite plates

One of the plates is rigidly connected to the moving

sur-face of the sample, and another plate is fixed by the holder

The capacitance change due to the vibration of sample

can be measured precisely by a zero-point potentiometer

and a lock-in amplifier Therefore, high resolution (in the

Å range) can be achieved by this technique The

mea-surement frequency must be much lower than the

fre-quency of the ac input signal, which typically does not

exceed 100 Hz

All of the aforementioned techniques require

mechan-ical contact between the sample and the measurement

unit This, however, limits the resolution and the

maxi-mum operating frequency, which prevents accurate

mea-surement of piezoelectric loss (the phase angle between

the driving voltage and the displacement) The force

ex-erted on the moving surface of the sample (especially on

a thin ceramic film) may damage the sample Therefore,

noncontact measurements are often preferred to determine

the electric-field-induced displacement of piezoelectric and

electrostrictive materials accurately Figure 5 shows the

operating principle of a Photonic fiber-optic sensor, which

can be used to examine the displacement of a flat reflecting

Lamp

Target surface

Probe

Photodetector

Opticalfibers

Gap

Figure 5 Schematic of the fiber-optic photonic sensor used for

nondestructive evaluation of electric-field-induced strains.

surface (8) The sensor head consists of a group of mitting and receiving optical fibers located in the immedi-ate vicinity of the vibrating surface of sample The inten-sity of the reflected light depends on the distance betweenthe moving object and the probe tip This dependence al-lows exact determination of displacement in both dc and

trans-ac modes Using a lock-in amplifier to magnify the outputsignal, which is proportional to the light intensity, a reso-lution of the order of 1 Å can be achieved (8) The frequencyresponse is determined by the frequency band of the pho-todiode and the amplifier (typically of the order of severalhundreds of kHz)

Optical interferometry is another technique that lows noncontact accurate measurement of the electric-field-induced displacements Interferometric methods ofmeasuring small displacements include the homodyne (9),heterodyne (10), and Fabri–Perot (11) techniques The mostcommon technique is the homodyne interferometer thatuses active stabilization of the working point to preventdrift from thermal expansion When two laser beams of the

optical path length between the two beams If one of thebeams is reflected from the surface of a moving object, theintensity of the output light changes, which can later betranslated to the amount of displacement Using a sim-ple Michelson interferometer (12), a very high resolution

limited to a narrow frequency range because the sample

is attached to a rigid substrate and only the displacement

of the front surface of the sample is monitored (12) As

a result of this configuration, the errors arising from thebending effect of the sample can be very high, especially inferroelectric thin films In response to that, a double beam(Mach–Zender) interferometer is used to take into accountthe difference of the displacements of both major surfaces

of the sample (13) The modified version of the double-beam

Trang 9

interferometer, specially adapted to measure thin films,

of 10–105Hz and long-term stability (<1%) (14).

COMMON PIEZOELECTRIC AND ELECTROSTRICTIVE

MATERIALS

Single Crystals

A number of single crystals (ferroelectric and

nonferroelec-tric) have demonstrated piezoelectricity However,

nonfer-roelectric piezoelectric crystals exhibit piezoelectric

coeffi-cients much lower than those of ferroelectric crystals The

former are still extensively used in some applications in

which either high temperature stability or low loss is

re-quired The most important nonferroelectric piezoelectric

used mostly in surface acoustic wave (SAW) devices

Re-cent investigations (15) have shown that rhombohedral

single crystals in the Pb(Zn1/3Nb2/3)O3–PbTiO3 system

addi-tion, ultrahigh strain of 1.7% has been observed in these

materials under high electric field These single crystals

are now being intensively investigated and show

signifi-cant promise for future generations of smart materials

Piezoelectric and Electrostrictive Ceramics

As indicated earlier, the randomness of the grains in

as-prepared polycrystalline ferroelectric ceramics yields

non-piezoelectric centrosymmetric material Thus “poling” the

ceramic (Fig 6) is required to induce piezoelectricity Due

to symmetry limitations, all of the domains in a ceramic

can never be fully aligned along the poling axis However,

the end result is a ceramic whose net polarization along the

poling axis has sufficiently high piezoelectric properties

The largest class of piezoelectric ceramics is made up

of mixed oxides that contain corner-sharing octahedra of

in this class are perovskites that have the general

ceramics that have this structure are barium titanate

Unpoled

Ep

Poled

Figure 6 Schematic of the poling process in piezoelectric

ceram-ics: (a) in the absence of an electric field, the domains have random

orientation of polarization; (b) the polarization within the domains

are aligned in the direction of the electric field.

titanate {Pb1−xLax(ZryT1−y)1−x/4O3, or PLZT}, and leadmagnesium niobate{PbMg1/3Nb2/3O3, or PMN}

in the 1940s (3), and it became the first recognizable

Ti4 +) coincides with the center of the negative charge (O2 −)(Fig 7a) When cooled below the Curie point, a tetragonalstructure (Fig 7b) develops where the center of positive

as a capacitor

Lead titanate (PbTiO3) first reported to be ferroelectric

through the Curie temperature, the grains go through a bic to tetragonal phase change that leads to a large strainwhich causes the ceramic to fracture Thus, it is difficult tofabricate pure lead titanate in bulk form This spontaneousstrain has been decreased by adding dopants such as Ca,

coefficient (d33) of 65 pC/N Because of its high piezoelectriccoefficient and low relative permittivity, the voltage piezo-electric coefficient of lead titanate ceramic is exceptionallyhigh Therefore, lead titanate is used in hydrophones andsonobuoys (17)

Lead zirconate titanate (PZT) is a binary solid solution

sites PZT has a temperature-independent morphotropicphase boundary (MPB) between tetragonal and rhom-bohedral phases, when the Zr:Ti ratio is 52:48 (Fig 8).This composition of PZT has efficient poling and excellentpiezoelectric properties because of its large number ofpolarization orientations At the MPB composition, PZT

is usually doped by a variety of ions to form what areknown as “hard” and “soft” PZTs (3) Doping PZT with

Al3 +, or Mn3 +at the B site, creates hard PZT This dopingreduces the piezoelectric properties and makes the PZT

Trang 10

FR (LT)

FR(IIT)

8 DomainStates <111>

FT

6 DomainStates < 100 >

Figure 8 Phase diagram of lead zirconate titanate piezoelectric

ceramics (PZT) as a function of mole% PbTiO 3

more resistant to poling and depoling Introducing donor

the B site, makes soft PZT This doping increases the

piezoelectric properties and makes the PZT easier to pole

and depole Table 1 compares the piezoelectric properties

of several major piezoelectric ceramics

perovskite ceramic known as a relaxor ferroelectric Unlike

normal ferroelectrics, which have well-defined Curie points

in their weak-field relative permittivity, relaxor

ferro-electrics exhibit a broad transition peak between

ferroelec-tric and paraelecferroelec-tric phases (18) This kind of transition is

often referred to as a diffuse phase transition The

dis-tinctive features of relaxor ferroelectrics are their strong

frequency dispersion of relative permittivity and a shift of

their maximum relative permittivity with frequency

Lo-cal inhomogeneity of B site ions (e.g., Mg2 +and Nb5 +) in

the perovskite lattice are the proposed cause of relaxor

properties Relaxors do not possess piezoelectricity

with-out a dc bias field to break the paraelectric cubic phase into

the rhombohedral ferroelectric piezoelectric phase

Relax-ors have been used as actuatRelax-ors because of their negligible

hysteresis and large induced polarization (electrostrictive

strain of the order of 10−3) Figure 9 compares the

electric-field-induced strains of typical piezoelectric (PZT) and

elec-trostrictive (PMN) ceramics

Processing of Piezoelectric Ceramics

The electromechanical properties of piezoelectric

ceram-ics are largely influenced by their processing conditions

Table 1 Piezoelectric Properties of Major Piezoelectric Ceramics

Quartz BaTiO3 PZT-4 PZT-5 PbTiO3:Sm

2

S3/10− 3

20 E3/ kVcm− 1

Figure 9 Comparison of the electric-field-induced strain in a

typical piezoelectric (PZT) and relaxor (0.9PMN–0.1PT).

Each step of the process must be carefully controlled toyield the best product Figure 10 is a flowchart of a typi-cal oxide manufacturing process for piezoelectric ceramics.First, high purity raw materials are accurately weighed ac-cording to their desired ratio and then are mechanically orchemically mixed During the calcination step, the solidphases react to form the piezoelectric phase After calcina-tion, the solid mixture is milled to fine particles Shaping

is accomplished by a variety of ceramic processing niques, including powder compaction, tape casting, slipcasting, and extrusion During the shaping operation, or-ganic materials are typically added to the ceramic powder

tech-to improve its flow and binding characteristics The organic

step After organic removal, the ceramic structure is fired

to an optimum density at an elevated temperature

crucibles in an optimized PbO atmosphere to prevent leadloss above 800◦C

PIEZOELECTRIC COMPOSITES

Single-phase piezoelectric/electrostrictive materials arenot ideally suited for hydrostatic and ultrasonic applica-tions where ceramic elements radiate and receive acous-

are exceptionally high in PZT ceramics, their hydrostaticvoltage response is relatively low due to the high di-electric constant and low hydrostatic charge coefficient

dh = d33+ 2d31 Because d31≈ −0.4d33in PZT ceramics (3),their hydrostatic sensor capabilities are rather low In

Trang 11

Figure 10 Flowchart for processing piezoelectric ceramics.

addition, the high density of ceramics results in a high

acoustic impedance mismatch between the transducer and

the medium in which the acoustic waves are propagating

On the other hand, piezoelectric polymers have low

den-sity (low impedance), dielectric constant, and piezoelectric

coefficients

In the past three decades, researchers have focused on

methods for combining the best characteristics of

ceram-ics and polymers to overcome the aforementioned

deficien-cies Integration of a piezoelectric ceramic with a polymer

allows tailoring the piezoelectric properties of composites

The mechanical and electrical properties of a composite

de-pend strongly on the characteristics of each phase and the

manner in which they are connected In a diphasic

compos-ite, the materials can be oriented in ten different ways in

a three-dimensional space (19) The possible connectivity

patterns are 0–0, 1–0, 2–0, 3–0, 1–1, 2–1, 3–1, 2–2, 3–2,

and 3–3 As a matter of convention, the first and second

numbers in the connectivity denote the continuity of the

piezoelectric and polymer phases, respectively Figure 11

shows some of the composites made in the past 30 years

(20) The most important connectivity patterns are 0–3,

1–3, 3–3, and 2–2 The 0–3 composites are made of a

ho-mogeneous distribution of piezoelectric ceramic particles

within a polymer matrix The primary advantage of these

composites is that they can be formed into shapes and

still retain their piezoelectricity However, they cannot be

sufficiently poled because the ceramic phase is not

self-connected in the poling direction On the other hand, 3–0

PerforatedComposite(3-1)

Ceramic-Air-PolymerComposite(1-1-3)

Particles in aPolymer(0-3)

PVDF CompositeModel(0-3)

Ceramic Rods

in a Polymer(1-3)

Diced Composite(1-3)

TransverseReinforcement(1-2-3)

PerforatedComposite(3-2)

Sheet Composite(2-2)

Moonie(3-0)

Ceramic-AirComposite(3-0)

HoneycombComposite(3-1)

ReplamineComposite(3-3)

BURPSComposite(3-3)

LadderComposite(3-3)

Figure 11 Schematic of various piezoelectric composites of different connectivities.

composites that are simply the ceramic matrix containing

a low concentration of polymer inclusions or voids can beeffectively poled and exhibit hydrostatic properties supe-rior to those of single-phase PZT (20)

In composites of 3–3 connectivity, the piezoceramic andpolymer phases are continuous in three dimensions andform two interlocking skeletons The first composite of 3–3connectivity was formed by the replamine process using

a coral skeleton (21) Another effective method of ing 3–3 composites is called BURPS (acronym for burnedout plastic spheres) (22) which provides properties similar

mak-to the replamine composites In this process, a mixture ofPZT powder and burnable plastic spheres is used to fabri-cate the PZT/polymer composites Other techniques, such

as relic processing (23) and distorted reticulated ceramics(24) have been developed to fabricate 3–3 composites Re-cently, fused deposition modeling (FDM) and fused deposi-tion of ceramics (FDC) have been used to make ladder and3-D honeycomb composites (25) In the FDM technique, a3-D plastic mold is prepared and filled with PZT slurry.The FDC process deposits a mixture of PZT and polymerdirectly in the form of a three-dimensional ladder struc-ture Either structure is heat treated to burn the organic,sintered, and embedded in epoxy polymer

The composites most extensively studied and used intransducer applications are those that have 1–3 connectivi-ties They consist of individual PZT rods or fibers aligned

in the direction parallel to poling and embedded in a mer matrix The rod diameter, spacing between them,

Trang 12

poly-composite thickness, volume% of PZT, and polymer

com-pliance influence the composite’s performance The most

common methods of forming 1–3 composites are the dice

and fill technique (26) and injection molding (27) In the

former method, the composite is fabricated by dicing deep

grooves in perpendicular directions into a solid sintered

block of poled PZT The grooves are backfilled with

poly-mer, and the base is removed via grinding or cutting In

the latter method, a thermoplastic mixture of ceramic

pow-der and organic binpow-der is injected into a cooled mold The

process can be used to form composites that have a variety

of rod sizes, shapes, and spacings This technique has

re-cently been employed by Materials Systems, Inc to mass

APPLICATIONS OF PIEZOELECTRIC/

ELECTROSTRICTIVE CERAMICS

By directly coupling mechanical and electrical quantities,

piezoelectrics and electrostrictives have been extensively

used in a variety of electromechanical devices for both

sen-sor and actuator applications The direct piezoelectric

ef-fect is currently being used to generate charge (voltage)

in applications such gas igniters, acoustic pressure

sen-sors, vibration sensen-sors, accelerometers, and hydrophones

(29) The best known examples of actuators, which take

advantage of the converse effect, are piezoelectric motors,

piezoelectrically driven relays, ink-jet heads for printers,

noise cancellation systems, VCR head trackers, precise

positioners, and deformable mirrors for correcting of

op-tical images (30) Acoustic and ultrasonic vibrations can

be generated by piezoelectrics using an ac field at

res-onance conditions and/or detected by a piezoelectric

re-ceiver Very often, an acoustic sender and receiver are

com-bined in the same piezoelectric devices Transducers have a

variety of applications, including imaging, nondestructive

testing, and fish finders (31) At high frequencies,

piezo-electric transducers also function as frequency control

de-vices, bulk and surface acoustic wave (SAW) resonators,

filters, and delay lines

Ultrasonic transducers operate in a so-called

pulse-echo mode, where a transducer sends an acoustic wave

that is reflected from the interfaces and is received by

the very same transducer These echoes vary in

inten-sity according to the type of interface, which may

in-clude tissue and bone Therefore, the ultrasonic image

that is created clearly represents the mechanical

prop-erties of human tissue Thus, anatomic structures of

dif-ferent organs can be recognized in real time A

sensi-tive ultrasonic transducer that generates low-intensity

acoustic waves can be one of the safest diagnostic

de-vices for medical imaging These transducers are usually

composed of matching and backing layers and the

piezo-electric material itself The matching layers are added

to the transducer to reduce the acoustic impedance

mis-match between the imaged object and the transducer,

and the backing layers dampen the acoustic backwaves

Composite materials instead of single phase materials

are frequently used to increase the performance of

trans-ducers (20)

Simple structures

PiezoelectricMetal

Structures withstrain amplification

BrassDispl

Displ

Displ

Figure 12 Typical actuator designs: simple structures [(a)–(d)]

and structures with strain amplification [(e)–(g)].

When a transducer function is to displace an object, it iscalled an actuator It is desirable for an actuator to generate

a significant displacement and/or generative force under amoderate electric field In addition, actuators must havereproducible displacements when precise positioning is im-portant Thus, electrostrictive materials such as PMN orits solid solution with PT are preferred over PZT materialsdue to their small hysteresis Figure 12 shows several pos-sible designs of piezoelectric/electrostrictive actuators Insimple structures, like those shown in Fig 12a–d, the ac-

tuator displacements are solely due to d33, d31, or d15effects

of the ceramic rod, plate, or tube Because strain is limited

to 10−3, the typical displacement of a 1-cm long actuator is

∼10 µm Multilayer actuators (Fig 12b) use a parallel

con-nection of ceramic plates cemented together In this case,the displacements of many individual sheets of a piezo-electric ceramic are summed The advantage of multilayeracuators is their small operating voltage, fast speed, andlarge generative force A useful design is the piezoelectrictube (Fig 12c) which is poled and driven by the voltageapplied in a radial direction (through the wall width) The

and is proportional to the length/width ratio The radialresponse can be tuned to almost zero by manipulating thegeometry of the tube (32) This configuration is beneficial insuppressing unwanted lateral displacements Another im-portant design is a shear actuator (Fig 12d) which directlytransforms the voltage applied normal to the polarization

vector into a pure rotation due to the d15coefficient (33)

As previously indicated, all of the simple structures are

based on pure d31, d33, or d15 actions, so that ments are limited to tens of microns The amplification ofstrain at the expense of generative force can be achieved

displace-by using monomorph and bimorph structures (Fig 12e–f).These types of actuators produce large displacements (up

to several mm) but have low generative force and slowresponse Another type of strain amplification can beachieved by flextensional transducers One of the designs,

Trang 13

SensorBrass

PZT

Brass

Feedbackloop

Figure 13 Example of the smart system using a PZT sensor

in-corporated in the MOONE actuator (36).

called MOONE, is shown in Fig 12g (34) This type of

ac-tuator uses the bending effect of the moon-shaped

metal-lic cap attached to both sides of a multilayer actuator

the metallic cap Other examples of flextensional

actua-tors are RAINBOWs and CYMBALs (not shown in the

fig-ure) (35, 36) Flextensional actuators have characteristics

intermediate between multilayers and bimorphs and are

now extensively used in various actuator applications An

example of a smart structure using flextensional actuator

(MOONE) is shown in Fig 13 The actuator portion of the

device consists of the standard MOONE and a small

piezo-electric ceramic embedded in the upper cap that serves as

a sensor The sensor detects vibrations normal to the

ac-tuator surface and, via a feedback loop, sends a signal of

appropriate amplitude and phase to the actuator, so that

it effectively cancels the external vibration Potential

ap-plications of the smart structure shown in Fig 13 include

active optical systems, rotor suspension systems, and other

noise cancellation devices

Recent trends toward miniaturization have resulted in

extensive use of piezoelectric/electrostrictive materials in

microelectromechanical systems (MEMS) Because

minia-turization of bulk ceramics is limited, these materials are

used in a thin/thick film form Thin film actuators based on

the piezoelectric effect in PZT materials have been

demon-strated They include micromotors (37), acoustic

imag-ing devices (38), components for atomic force microscopes

(AFM) (39), and micropumps (40) Figure 14 shows the

de-sign of an atomic force microscope using PZT film for both

sensing and actuating functions The excitation ac voltage

signal superimposed on the actuation dc voltage is applied

to the PZT film deposited on the Si cantilever The

vibra-tional amplitude, which is sensitive to the atomic force

between the tip and investigated surface, is detected by

measuring the difference between the cantilever current

and the reference current The feedback system maintains

a constant current while scanning in the x, y plane This

system does not require optical registration of the vibration

that makes PZT-based AFM compact and it allows the

mul-tiprobe systems to be achieved Because PZT film is very

sensitive to vibrations, the vertical resolution of such an

AFM approaches that of conventional systems This

elec-tromechanically driven AFM is an excellent example of

us-ing piezoelectric ceramic thin films as smart materials

Feedback controller

Lock-in Amplifier A

PZ Tfilm

Si cantilever

SampleTube scanner(x-y scanning)Differential Current Amplifier

FeedbacksignalFrequency

synthesizer

Ref

+

Figure 14 Schematic of the AFM cantilever sensor and actuator

based on a PZT thin film.

FUTURE TRENDS

Most piezoelectric/electrostrictive ceramics currently rely

on lead oxide based materials due to their excellent erties as sensors and actuators However, due to increasedpublic awareness of health problems associated with leadand environmental protection policies, future research will

prop-be focused on finding lead-free compounds that have electric properties similar to those of PZT Relaxor single-crystal materials that have a giant piezoelectric effect willprobably find a wide range of applications from compositetransducers for medical imaging to microelectromechan-ical systems The current trend of miniaturization willcontinue to give rise to complex sensors and actuators inte-grated directly on a silicon chip Further, batch processingwill effectively reduce the cost of such devices In addi-tion, the research will continue toward the development ofmore resilient piezoelectric/electrostrictive materials usedfor operation under severe external conditions (tempera-ture, pressure, harsh chemical environments) This willfurther improve their potential application in space anddeep ocean exploration, as well as in noise cancellation inairplanes and helicopters

piezo-BIBLIOGRAPHY

1 R.E Newnham and G.R Ruschau, J Intelli Materi., Syst.

Struct 4, 289 (1993).

2 L Ristic, ed., Sensor Technology and Devices, Chapter 1.

Artech House, Boston, MA, 1994.

3 B Jaffe, W.R Cook, Jr., and H Jaffe, Piezoelectric Ceramics,

Marietta, R.A.N., OH, 1971.

4 J.F Nye, Physical Properties of Crystals, Oxford University

Press, Oxford, UK, 1985.

5 M.J Haun, E Furman, S.J Jang, and L.E Cross, IEEE Trans.

Ultrason., Ferroelectr Freq Control 36(4), 393 (1989).

6 IEEE Standards on Piezoelectricity, IEEE Stand 176

(1978).

7 V.F Janas, A Safari, A Bandyopadhyay, and A Kholkin, in

Measurements, Instrumentation and Sensor Handbook (J.G.

Webster, ed.) CRC Press, Boca Raton, FL.

Trang 14

8 MTI-2000 Fotonic TM Sensor, Instruction Manual, MTI

Instru-ments Division, Latham, New York.

9 S Sizgoric and A.A Gundjian, Proc IEEE 57, 1312

(1969).

10 R.M De La Rue, R.F Humphreys, I.M Masom, and E.A Ash,

Proc IEEE 119, 117 (1972).

11 V.E Bottom, Rev Sci Instrum 35, 374 (1964).

12 Q.M Zhang, W.Y Pan, and L.E Cross, J Appl Phys 65, 2807

16 Piezoelectric Products, Sensor Technology Limited,

Col-lingwood, Ontario, Canada, 1991.

17 K.M Rittenmyer and R.Y Ting, Ferroelectrics 110, 171 (1990).

18 L.E Cross, in Ferroelectric Ceramics: Tutorials, Reviews,

The-ory, Processing and Applications, (N Setter and E Colla, eds.).

Birkhaeuser, Basel, 1993.

19 R.E Newnham, D.P Skinner, and L.E Cross, Mater Res Soc.

Bull 13, 525 (1978).

20 T.R Gururaja, A Safari, R.E Newnham, and L.E Cross, in

Electronic Ceramics (L.M Levinson, ed.), p 92 Dekker, New

25 A Bandyopadhayay, R.K Panda, V.F Janas, M.K Agarwala,

S.C Danforth, and A Safari, J Am Ceram Soc 80, 1366

(1997).

26 H.P Savakus, K.A Klicker, and R.E Newnham, Mater Res.

Soc Bull 16, 677 (1981).

27 R.L Gentilman, D.F Fiore, H.T Pham, K.W French, and

L.W Bowen, Ceram Transa 43, 239 (1994).

28 D Fiore, R Torri, and R Gentilman, Proc 8th U.S.-Jpn.

Semin Dielectr Piezoelectr Ceram., Plymouth, MA, 1997.

29 A.J Moulson and J.M Herbert, Electroceramics: Materials,

Properties, Applications, Chapman & Hall, London, 1990.

30 K Uchino, Piezoelectric Actuators and Ultrasonic Motors,

Kluwer, Boston, MA, 1997.

31 J.M Herbert, Ferroelectric Transducers and Sensors, Gordon

& Breach, New York, 1982.

32 Q.M Zhang, H Wang, and L.E Cross, Proc SPIE, Smart

Struct Mater 1916, 244 (1993).

33 A.E Glazounov, Q.M Zhang, and C Kim, Appl Phys Lett 72,

2526 (1998).

34 A Dogan, Q.C Xu, K Onitsuka, S Yoshikawa, K Uchino, and

R.E Newnham, Ferroelectrics 156, 1 (1994).

35 G Haertling, Bull Am Ceram Soc 73, 93 (1994).

36 A Dogan, K Uchino, and R.E Newnham, IEEE Trans.

Ultrason., Ferroelectr Freq Control 44, 597 (1997).

37 P Muralt, M Kohli, T Maeder, A Kholkin, K Brooks,

N Setter, and R Luthier, Sensors Actuators A48, 157

(1995).

38 R.E Newnham, J.F Fernandez, K.A Markowski, J.T Fielding,

A Dogan, and J Wallis, Mater Res Soc Proc 360 33

(1995).

39 J Bernstein, K Houston, L Niles, K Li, H Chen, L.E Cross,

and K Udayakumar, Proc 8th Int Symp Integr Ferroelectr.,

INTRODUCTION Smart Material

Let us start with the “smartness” of a material Table 1lists the various effects that relate the input—electric field,magnetic field, stress, heat and light—to the output—charge/current, magnetization, strain, temperature, andlight Conducting and elastic materials that generate cur-rent and strain outputs, respectively, from input voltage,

or stress (well-known phenomena!) are sometimes called

“trivial” materials Conversely, pyroelectric and tric materials that generate an electric field from the in-put of heat or stress (unexpected phenomena!) are called

piezoelec-“smart” materials These off-diagonal couplings have a responding converse effect such as electrocaloric and con-verse piezoelectric effects, and both “sensing” and “actu-ating” functions can be realized in the same materials

cor-“Intelligent” materials should possess a “drive/control” or

“processing” function which is adaptive to the change inenvironmental conditions, in addition to the actuation andsensing functions Note that ferroelectric materials exhibitmost of these effects, except magnetic-related phenom-ena Thus, the ferroelectrics are said to be very “smart”materials

The “actuator” in a narrow meaning stands for als or devices that generate mechanical strain (or stress)output As indicated by the thick columnar border inTable 1, solid state actuators use converse piezoelectric,magnetostriction, elasticity, thermal expansion, or photo-striction phenomena A shape-memory alloy is a kind

materi-of thermally expanding material On the other hand, a

“sensor” requires charge/current output in most cases.Thus, conducting/semiconducting, magnetoelectric, piezo-electric, pyroelectric, and photovoltaic materials are usedfor detecting electric fields, magnetic fields, stress, heat,and light, respectively (see the thin columnar border inTable 1)

In this sense, piezoelectric materials are most larly used in smart structures and systems because thesame material is applicable to both sensors and actua-tors, in principle We treat mainly piezoelectric transduc-ers, sensors, and actuators in this article Even thoughtransducers, in general, are devices that convert input en-ergy to a different energy type of output, the piezoelectric

Trang 15

popu-Table 1 Various Effects in Ferroelectric and Ferromagnetic Materials

Input →MaterialDevice → Output Output Charge

Elec eld Permittivity Elect.-mag Converse Elec caloric Elec.-optic

Conductivity effect piezo-effect effect effect Mag eld Mag.-elect Permeability Magneto- Mag.caloric Mag.optic

Sensor Actuator

aOff-diagonal coupling

= Smart Material

a

“transducer” is often used to denote a device that possesses

both sensing and actuating functions, exemplified by

un-derwater sonar

Piezoelectric Effect

Certain materials produce electric charges on their

sur-faces as a consequence of applying mechanical stress

When the induced charge is proportional to the mechanical

stress, it is called a direct piezoelectric effect and was

dis-covered by J and P Curie in 1880 Materials that show this

phenomenon also conversely have a geometric strain

gen-erated that is proportional to an applied electric field This

is the converse piezoelectric effect The root of the word

“piezo” is the Greek word for “pressure”; hence the

origi-nal meaning of the word piezoelectricity implied “pressure

electricity” (1,2)

Piezoelectric materials couple electrical and mechanical

parameters The material used earliest for its piezoelectric

properties was single-crystal quartz Quartz crystal

res-onators for frequency control appear today at the heart

of clocks and are also used in TVs and computers

Ferro-electric polycrystalline ceramics, such as barium titanate

and lead zirconate titanate, exhibit piezoelectricity when

electrically poled Because these ceramics possess

signif-icant and stable piezoelectric effects, that is, high

elec-tromechanical coupling, they can produce large strains/

forces and hence are extensively used as transducers

Piezoelectric polymers, notably polyvinylidene difluoride

and its copolymers with trifluoroethylene and

piezoelec-tric composites that combine a piezoelecpiezoelec-tric ceramic and a

passive polymer have been developed and offer high

poten-tial Recently, thin films of piezoelectric materials are being

researched due to their potential use in microdevices

(sen-sors and microelectromechanical systems)

Piezoelectric-ity is being extensively used in fabricating various devices

such as transducers, sensors, actuators, surface acoustic

wave devices, and frequency controls

We describe the fundamentals of piezoelectric effectfirst, then present a brief history of piezoelectricity, fol-lowed by present day piezoelectric materials that are used,and finally various potential applications of piezoelectricmaterials are presented

PIEZOELECTRICITY Relationship Between Crystal Symmetry and Properties

All crystals can be classified into 32 point groups according

to their crystallographic symmetry These point groups aredivided into two classes; one has a center of symmetry, andthe other lacks it There are 21 noncentrosymmetric pointgroups Crystals that belong to 20 of these point groupsexhibit piezoelectricity Although cubic class 432 lacks acenter of symmetry, it does not permit piezoelectricity Ofthese 20 point groups, 10 polar crystal classes contain aunique axis, along which an electric dipole moment is ori-ented in the unstrained condition

The pyroelectric effect appears in any material that sesses a polar symmetry axis The material in this cate-gory develops an electric charge on the surface owing tothe change in dipole moment as temperature changes Thepyroelectric crystals whose spontaneous polarization arereorientable by applying an electric field of sufficient mag-nitude (not exceeding the breakdown limit of the crystal)are called ferroelectrics (3,4) Table 2 shows the crystallo-graphic classification of the point groups

pos-Piezoelectric Coefficients

Materials are deformed by stresses, and the resulting

stress X (force per unit area) causes a proportional strain x,

where all quantities are tensors, x and X are second rank, and s is fourth rank Piezoelectricity creates additional

Trang 16

Table 2 Crystallographic Classification According to Crystal Centrosymmetry and Polarity

Non-Centro (11) m3m m3 6/ mmm 6/m 4/mmm 4/m 3m 3 mmm 2/m

centro (21)

Polar (pyro- electric) (10)

where E is the electric field and d is the piezoelectric

con-stant which is a third-rank tensor This equation can be

also expressed in a matrix form such as for a poled ceramic:

x1 x2 x3 x4 x5 x6

Another frequently used piezoelectric constant is g

which gives the electric field produced when a stress is

effectiveness of the electromechanical energy conversion is

the electromechanical coupling factor k, which measures

the fraction of electrical energy converted to mechanical

energy when an electric field is applied or vice versa when

a material is stressed (5):

(5)or

= (stored electrical energy/input mechanical energy).

(6)

is applied to a piezoelectric material Because the input

stored mechanical energy per unit volume under zero

ex-ternal stress is given by (1/2) x2/s = (1/2)(dE)2/s, k2 can

be calculated as

k2= [(1/2)(dE)2/s]/[(1/2)ε0ε E2

]

Note that k is always less than one Typical values of k are

ceramic and 0.1–0.3 for PVDF polymer Another important

an inverse value of mechanical loss:

is most desired for ultrasonic actuations (e.g., ultrasonicmotors) to suppress heat generation through the loss

History of Piezoelectricity

As already stated, Pierre and Jacques Curie discoveredpiezoelectricity in quartz in 1880 The discovery of ferro-electricity accelerated the creation of useful piezoelectricmaterials Rochelle salt was the first ferroelectric disco-vered in 1921 Until 1940 only two types of ferroelectricswere known, Rochelle salt and potassium dihydrogen phos-phate and its isomorph In 1940 to 1943, unusual dielectricproperties such as an abnormally high dielectric constant

by Wainer and Salmon, Ogawa, and Wul and Golman

led to improvement in temperature stability and

ceramics became well established in a number of devices

In the 1950s, Jaffe and co-workers established thatthe lead zirconate–lead titanate system (called the PZTsystem) induces strong piezoelectric effects The maximumpiezoelectric response was found for PZT compositions nearthe morphotropic phase boundary between the rhombohe-dral and tetragonal phases Since then, the PZT systemcontaining various additives has become the dominantpiezoelectric ceramic for a variety of applications The de-velopment of PZT-based ternary solid solutions was a majorsuccess of the piezoelectric industry for these applications

In 1969, Kawai et al discovered that certain polymers,notably polyvinylidene difluoride (PVDF), are piezoelec-tric when stretched during fabrication Such piezoelectricpolymers are also useful for some transducer applications

Trang 17

Table 3 Material Parameters of Representative Piezoelectric Materials

Parameter Quartz BaTiO 3 PZT4 PZT 5H (Pb,Sm)TiO 3 PVDF-TrFE

In 1978, Newnham et al improved composite

piezoelec-tric materials by combining a piezoelecpiezoelec-tric ceramic and a

passive polymer whose properties can be tailored to the

requirements of various piezoelectric devices

Another class of ceramic material has recently become

important: relaxor-type electrostrictors such as lead

mag-nesium niobate (PMN), typically doped with 10% lead

ti-tanate (PT), which have potential applications in the

piezo-electric actuator field A recent breakthrough in the growth

of high-quality, large, single-crystal relaxor piezoelectric

compositions has created interest in these materials for

applications ranging from high strain actuators to

high-frequency transducers for medical ultrasound devices due

to their superior electromechanical characteristics More

recently, thin films of piezoelectric materials such as zinc

oxide (ZnO) and PZT have been extensively investigated

and developed for use in microelectromechanical (MEMS)

devices

PIEZOELECTRIC MATERIALS

This section summarizes the current status of

piezo-electric materials: single-crystal materials, piezoceramics,

piezopolymers, piezocomposites, and piezofilms Table 3

shows the material parameters of some representative

piezoelectric materials described here (6,7)

Single Crystals

Piezoelectric ceramics are widely used at present for a large

number of applications However, single-crystal materials

retain their utility; they are essential for applications such

as frequency stabilized oscillators and surface acoustic

devices The most popular single-crystal piezoelectric

general, and have different properties depending on the

cut of the materials and the direction of the bulk or

sur-face wave propagation

belongs to the triclinic crystal system with point group 32

not piezoelectric Quartz has a cut with a zero temperature

coefficient at the resonant frequency change For instance,

quartz oscillators using the thickness shear mode of the

AT-cut are extensively used as clock sources in computers

and as frequency stabilized oscillators in TVs, and VCRs

On the other hand, an ST-cut quartz substrate that has X

propagation has a zero temperature coefficient for surface

acoustic waves and so is used for SAW devices that havehighly stabilized frequencies Another distinguishing char-acteristic of quartz is its extremely high mechanical quality

factor Qm> 105.Lithium niobate and lithium tantalate belong to an iso-morphous crystal system and are composed of oxygen oc-

the ferroelectric phase of these single crystals is 3m, and

the polarization direction is along the c axis These terials have high electromechanical coupling coefficientsfor surface acoustic waves In addition, large single crys-tals can easily be obtained from their melts by using theconventional Czochralski technique Thus, both materialsare very important in SAW device applications

ma-Perovskite Ceramics

Most of the piezoelectric ceramics have the perovskite

of a simple cubic unit cell that has a large cation A at thecorner, a smaller cation B in the body center, and oxygens O

in the centers of the faces The structure is a network

of corner-linked oxygen octahedra surrounding B cations.The piezoelectric properties of perovskite-structured mate-rials can be easily tailored for applications by incorporatingvarious cations in the perovskite structure

Barium Titanate Barium titanate (BaTiO3) is one of themost thoroughly studied and most widely used piezoelec-tric materials Figure 2 shows the temperature dependence

Trang 18

Figure 2 Dielectric constants of BaTiO3 as

anoma-lies can be observed The discontinuity at the Curie point

paraelectric phase The other two discontinuities are

ac-companied by transitions from one ferroelectric phase to

another Above the Curie point, the crystal structure is

cu-bic and has no spontaneous dipole moments At the Curie

point, the crystal becomes polar, and the structure changes

from a cubic to a tetragonal phase The dipole moment and

the spontaneous polarization are parallel to the

tetrago-nal axis Just below the Curie temperature, the vector of

the spontaneous polarization points in the [001] direction

(tetragonal phase), below 5◦C it reorients in the [011]

(rhombohe-dral phase) The dielectric and piezoelectric properties of

sto-ichiometry, microstructure, and by dopants entering into

contains dopants such as Pb or Ca ions have been used as

commercial piezoelectric materials

Lead Zirconate–Lead Titanate Piezoelectric Pb(Ti, Zr)O3

solid-solution (PZT) ceramics are widely used because of

their superior piezoelectric properties The phase diagram

of the PZT system (Pb(ZrxTi1 −x) O3) is shown in Fig 3 The

crystalline symmetry of this solid solution is determined

by the Zr content Lead titanate also has a tetragonal

fer-roelectric phase of the perovskite structure As the Zr

con-tent x increases, the tetragonal distortion decreases, and

tetrago-nal 4mm phase to another ferroelectric phase of

rhombohe-dral 3m symmetry Figure 4 shows the dependence of

sev-eral d constants on the composition near the morphotropic

phase boundary between the tetragonal and rhombohedral

phases The d constants have their highest values near the

morphotropic phase boundary This enhancement in the

piezoelectric effect is attributed to the increased ease of

reorientation of the polarization in an electric field

Dop-ing the PZT material with donors or acceptors changes the

properties dramatically Donor doping with ions such as

Nb5 +or Ta5 +provides soft PZTs like PZT-5, because of the

facility of domain motion due to the charge compensation

200

PbTiO3

Mole % PbZrO3

100

a ac

a

Rhombohedrala

Tetragonal Morphotropic

phaseboundery

a

Cubicaa

Figure 3 Phase diagram of the PZT system.

of the Pb vacancy which is generated during sintering Onthe other hand, acceptor doping with Fe3 +or Sc3 +leads tohard PZTs such as PZT-8 because oxygen vacancies pin thedomain wall motion

Lead Titanate PbTiO3 has a tetragonal structure at

d15

d33

Figure 4 Piezoelectric d strain coefficients versus composition

for the PZT system.

Trang 19

The Curie temperature is 490◦C Densely sintered PbTiO3

ceramics cannot be obtained easily because they break

up into powders when cooled through the Curie

temper-ature This is partly due to the large spontaneous strain

that occurs at the transition Lead titanate ceramics

mod-ified by small amounts of additives exhibit high

(9) has extremely low planar coupling, that is, a large

kt/kp ratio Here, ktand kpare thickness-extensional and

planar electromechanical coupling factors, respectively

tem-perature coefficient of surface acoustic wave delay have

been developed as superior substrate materials for SAW

devices (10)

Relaxor Ferroelectrics Relaxor ferroelectrics differ from

normal ferroelectrics; they have broad phase transitions

from the paraelectric to the ferroelectric state, strong

fre-quency dependence of the dielectric constant (i.e., dielectric

relaxation), and weak remanent polarization at

tempera-tures close to the dielectric maximum Lead-based relaxor

materials have complex disordered perovskite structures

of the general formula Pb(B1, B2) O3(B1= Mg2 +, Zn2 +, Sc3 +;

B2= Nb5 +, Ta5 +, W6 +) The B-site cations are distributed

randomly in the crystal The characteristic of a relaxor is a

broad and frequency dispersive dielectric maximum In

ad-dition, relaxor-type materials such as the lead magnesium

niobate Pb(Mg1/3Nb2/3)O3–lead titanate PbTiO3 solid

so-lution (PMN–PT) exhibit electrostrictive phenomena that

are suitable for actuator applications Figure 5 shows an

electric-field-induced strain curve that was observed for

0.9 PMN–0.1 PT and reported by Cross et al in 1980 (11)

Note that a strain of 0.1% can be induced by an electric

field as small as 1 kV/mm and that hysteresis is negligibly

small for this electrostriction

Because electrostriction is the secondary

electrome-chanical coupling observed in cubic structures, in principle,

Figure 5 Field-induced electrostrictive strain in 0.9PMN–0.1PT.

the charge is not induced under applied stress The verse electrostrictive effect, which can be used for sensorapplications, means that the permittivity (the first deriva-tive of polarization with respect to an electric field) ischanged by stress

con-In relaxor ferroelectrics, the piezoelectric effect can beinduced under a bias field, that is, the electromechani-

changes As the dc bias field increases, the coupling creases and saturates These materials can be used for ul-trasonic transducers that are tunable by a bias field (12).The recent development of single-crystal piezoelectricsstarted in 1981, when Kuwata et al first reported an

solid-solution single crystals between relaxor and normalferroelectrics, Pb(Zn1/3Nb2/3)O3–PbTiO3(13) After about

10 years, Yamashita et al (Toshiba) and Shrout et al.(Penn State) independently reconfirmed that these val-ues are true, and much more improved data were ob-tained in these few years, aimed at medical acoustic ap-plications (14,15) Important data have been accumulatedfor Pb(Mg1/3Nb2/3)O3(PMN), Pb(Zn1/3Nb2/3)O3(PZN), and

(PMN–PT and PZN–PT) for actuator applications Strains

as large as 1.7% can be induced practically for a photropic phase boundary composition of PZN–PT solid-solution single crystals Figure 6 shows the field-inducedstrain curve for [001] oriented 0.92PZN–0.08PT (15) It isnotable that the highest values are observed for a rhom-bohedral composition only when the single crystal is poledalong the perovskite [001] axis, not along the [111] spon-taneous polarization axis

mor-Polymers

piezoelec-tric when stretched during fabrication Thin sheets of thecast polymer are drawn and stretched in the plane of the

00.0

60Electric field (kV/cm)

0.51.01.5

Trang 20

sheet in at least one direction and frequently also in the

perpendicular direction to convert the material into its

microscopically polar phase Crystallization from a melt

dipoles are then reoriented by electric poling Large sheets

can be manufactured and thermally formed into complex

shapes Copolymerization of vinylidene difluoride with

trifluoroethylene (TrFE) results in a random copolymer

poly-mer does not need to be stretched; it can be poled directly

as formed A thickness-mode coupling coefficient of 0.30

has been reported Such piezoelectric polymers are used

for directional microphones and ultrasonic hydrophones

Composites

Piezocomposites comprised of piezoelectric ceramics and

polymers are promising materials because of excellent

tai-lored properties The geometry of two-phase composites

can be classified according to the connectivity of each phase

(0, 1, 2, or 3 dimensionality) into 10 structures; 0–0, 0–1,

0–2, 0–3, 1–1, 1–2, 1–3, 2–2, 2–3, and 3–3 (15) A 1–3

piezo-composite, or PZT-rod / polymer-matrix composite is a most

promising candidate The advantages of this composite are

high coupling factors, low acoustic impedance (square root

of the product of its density and elastic stiffness), a good

match to water and human tissue, mechanical flexibility,

a broad bandwidth in combination with a low

mechani-cal quality factor, and the possibility of making undiced

arrays by structuring only the electrodes The

thickness-mode electromechanical coupling of the composite can

almost approaches the value of the rod-mode

acoustic match to tissue or water (1.5 Mrayls) of typical

piezoceramics (20–30 Mrayls) is significantly improved by

forming a composite structure, that is, by replacing a heavy,

stiff ceramic by a light, soft polymer Piezoelectric

compo-site materials are especially useful for underwater sonar

and medical diagnostic ultrasonic transducers

Thin Films

Both zinc oxide (ZnO) and aluminum nitride (AlN) are

sim-ple binary compounds that have Wurtzite type structures,

which can be sputter-deposited in a c-axis oriented thin

film on a variety of substrates ZnO has reasonable

piezo-electric coupling, and its thin films are widely used in bulk

acoustic and surface acoustic wave devices The fabrication

of highly c-axis oriented ZnO films has been extensively

studied and developed The performance of ZnO devices is,

however, limited due to their small piezoelectric coupling

(20–30%) PZT thin films are expected to exhibit higher

piezoelectric properties At present, the growth of PZT

thin film is being carried out for use in microtransducers

and microactuators A series of theoretical calculations on

perovskite type ferroelectric crystals suggests that large

d and k values of magnitudes similar to those of PZN–PT

can also be expected in PZT Crystal orientation

depen-dence of piezoelectric properties was phenomenologically

EE

Figure 7 The principle of enhancement in electromechanical

couplings in a perovskite piezoelectric.

calculated for compositions around the morphotropic phaseboundary of PZT (17) The maximum longitudinal piezo-

the rhombohedral composition were found at angles of 57

polar-ization direction [111], which correspond roughly to theperovskite [100] axis

Figure 7 shows the principle of the enhancement in

the highest in perovskite piezoelectric crystals, the appliedfield should be canted from the spontaneous polarizationdirection to obtain the maximum strain Epitaxially grown,[001] oriented thin/thick films using a rhombohedral PZTcomposition reportedly enhance the effective piezoelectricconstant by four to five times

APPLICATIONS OF PIEZOELECTRICITY

Piezoelectric materials can provide coupling between trical and mechanical energy and thus have been exten-sively used in a variety of electromechanical devices Thedirect piezoelectric effect is most obviously used to generatecharge or high voltage in applications such as the spark ig-nition of gas in space heaters, cooking stoves, and cigarettelighters Using the converse effect, small mechanical dis-placements and vibrations can be produced in actuators

elec-by applying an electric field Acoustic and ultrasonic brations can be generated by an alternating field tuned atthe mechanical resonant frequency of a piezoelectric deviceand can be detected by amplifying the field generated byvibration incident on the material, which is usually usedfor ultrasonic transducers Another important application

vi-of piezoelectricity is frequency control The application vi-ofpiezoelectric materials ranges over many fields, includingultrasonic transducers, actuators, and ultrasonic motors;electronic components such as resonators, wave filters, de-lay lines; SAW devices and transformers and high-voltageapplications; and gas igniters, and ultrasonic cleaning andmachining Piezoelectric-based sensors, for instance, ac-celerometers, automobile knock sensors, vibration sensors,strain gages, and flow meters have been developed becausepressure and vibration can be directly sensed as electric

Trang 21

signals through the piezoelectric effect Examples of these

applications are given in the following sections

Pressure Sensor/Accelerometer/Gyroscope

The gas igniter is one of the basic applications of

piezoelec-tric ceramics Very high voltage generated in a piezoelecpiezoelec-tric

ceramic under applied mechanical stress can cause

spark-ing and ignite a gas

Piezoelectric ceramics can be employed as stress sensors

and acceleration sensors, because of their “direct

piezo-electric effect.” Kistler (Switzerland) is manufacturing a

3-D stress sensor By combining an appropriate number

of quartz crystal plates (extensional and shear types), the

multilayer device can detect three-dimensional stresses

(18)

Figure 8 shows a cylindrical gyroscope commercialized

by Tokin (Japan) (19) The cylinder has six divided

elec-trodes; one pair is used to excite the fundamental bending

vibration mode, and the other two pairs are used to

de-tect acceleration When rotational acceleration is applied

around the axis of this gyro, the voltage generated on the

electrodes is modulated by the Coriolis force By

subtract-ing the signals between the two sensor electrode pairs, a

voltage directly proportional to the acceleration can be

ob-tained This type of gyroscope has been widely installed

in handheld video cameras to monitor the inevitable hand

vibration during operation and to compensate for it

elec-tronically on a display by using the sensed signal

Ultrasonic Transducer

One of the most important applications of piezoelectric

materials is based on the ultrasonic echo field (20,21)

Ultrasonic transducers convert electrical energy into a

mechanical form when generating an acoustic pulse and

convert mechanical energy into an electrical signal when

detecting its echo Nowadays, piezoelectric transducers are

being used in medical ultrasound for clinical applicationsthat range from diagnosis to therapy and surgery They arealso used for underwater detection, such as sonars and fishfinders, and nondestructive testing

Ultrasonic transducers often operate in a pulse-echomode The transducer converts electrical input into anacoustic wave output The transmitted waves propagateinto a body, and echoes are generated that travel back to

be received by the same transducer These echoes vary inintensity according to the type of tissue or body structure,and thereby create images An ultrasonic image representsthe mechanical properties of the tissue, such as density andelasticity We can recognize anatomical structures in an ul-trasonic image because the organ boundaries and fluid-to-tissue interfaces are easily discerned Ultrasonic imagingcan also be done in real time This means that we can fol-low rapidly moving structures such as the heart withoutmotional distortion In addition, ultrasound is one of thesafest diagnostic imaging techniques It does not use ion-izing radiation like X rays and thus is routinely used forfetal and obstetrical imaging Useful areas for ultrasonicimaging include cardiac structures, the vascular system,the fetus, and abdominal organs such as the liver and kid-ney In brief, it is possible to see inside the human body byusing a beam of ultrasound without breaking the skin.There are various types of transducers used in ultra-sonic imaging Mechanical sector transducers consist ofsingle, relatively large resonators that provide images bymechanical scanning such as wobbling Multiple elementarray transducers permit the imaging systems to accessdiscrete elements individually and enable electronic focus-ing in the scanning plane at various adjustable penetrationdepths by using phase delays The two basic types of arraytransducers are linear and phased (or sector) Linear arraytransducers are used for radiological and obstetrical exam-inations, and phased array transducers are useful for car-diologcal applications where positioning between the ribs

is necessary

Figure 9 shows the geometry of the basic sonic transducer The transducer is composed mainly of

ultra-Inputpulse

Trang 22

matching, piezoelectric material, and backing layers (22).

One or more matching layers are used to increase sound

transmissions into tissues The backing is attached to the

transducer rear to damp the acoustic returnwave and to

re-duce the pulse duration Piezoelectric materials are used

to generate and detect ultrasound In general, broadband

transducers should be used for medical ultrasonic

imag-ing The broad bandwidth response corresponds to a short

pulse length that results in better axial resolution Three

factors are important in designing broad bandwidth

trans-ducers The first is acoustic impedance matching, that is,

effectively coupling the acoustic energy to the body The

second is high electromechanical coupling coefficient of the

transducer The third is electrical impedance matching,

that is, effectively coupling electrical energy from the

driv-ing electronics to the transducer across the frequency

range of interest The operator of pulse-echo transducers

is based on the thickness mode resonance of the

is related to the efficiency of converting electric energy into

acoustics and vice versa Further, a low planar mode

cou-pling coefficient kpis beneficial for limiting energies from

being expended in a nonproductive lateral mode A large

dielectric constant is necessary to enable a good electrical

impedance match to the system, especially in tiny

piezo-electric sizes

Table 4 compares the properties of ultrasonic

trans-ducer materials (7,23) Ferroelectric ceramics, such as lead

zirconate titanate and modified lead titanate, are almost

universally used as ultrasonic transducers The success of

ceramics is due to their very high electromechanical

cou-pling coefficients In particular, soft PZT ceramics such as

PZT-5A and 5H type compositions are most widely used

because of their exceedingly high coupling properties and

because they can be relatively easily tailored, for instance,

in the wide dielectric constant range On the other hand,

modified lead titanates such as samarium-doped

mate-rials have high piezoelectric anisotropy: the planar

to reduced interference from spurious lateral resonances

in longitudinal oscillators, this is very useful in

high-frequency array transducer applications One

disadvan-tage of PZT and other lead-based ceramics is their large

compared to body tissue (1.5 Mrayls) Single or multiple

matching layers of intermediate impedances need to be

used in PZT to improve acoustic matching

On the other hand, piezoelectric polymers, such as

poly-vinylidene difluoride-trifluoroethylene, have much lower

Table 4 Comparison of the Properties of Ultrasonic Transducer Materials

Piezoelectric ceramic/polymer composites are tives to ceramics and polymers Piezocomposites that have2–2 or 1–3 connectivity are commonly used in ultra-sonic medical applications They combine the low acousticimpedance advantage of polymers and the high sensitivityand low electrical impedance advantages of ceramics.The design frequency of a transducer depends on thepenetration depth required by the application Resolu-tion is improved as frequency increases Although a high-frequency transducer can produce a high-resolution image,higher frequency acoustic energy is more readily attenu-ated by the body A lower frequency transducer is used

alterna-as a compromise when imaging deeper structures Mostmedical ultrasound imaging systems operate in the fre-quency range from 2–10 MHz and can resolve objects ap-proximately 0.2–1 mm in size At 3.5 MHz, imaging to adepth of 10–20 cm is possible, and at 50 MHz, increasedlosses limit the depth to less than 1 cm Higher frequencytransducers (10–50 MHz) are used for endoscopic imag-ing and for catheter-based intravascular imaging Ultra-sound microscopy is being done at frequencies higher than

100 MHz The operating frequency of the transducer isdirectly related to the thickness and velocity of sound inthe piezoelectric materials employed As the frequencyincreases, resonator thickness decreases For a 3.5 MHztransducer, the PZT ceramic must be roughly 0.4 mm thick.Conventional ceramic transducers, such as PZT, are lim-ited to frequencies below 80 MHz because of the difficulty

of fabricating thinner devices (24) Piezoelectric thin-filmtransducers such as ZnO have to be used for microscopicapplications (at frequencies higher than 100 MHz, corre-

Resonator and Filter

When a piezoelectric body vibrates at its resonant quency, it absorbs considerably more energy than at otherfrequencies, resulting in a fall of the impedance This phe-nomenon enables using piezoelectric materials as wave fil-ters A filter is required to pass a certain selected frequencyband or to stop a given band The bandwidth of a filter fab-ricated from a piezoelectric material is determined by the

fre-square of the coupling coefficient k Quartz crystals that have very low k values of about 0.1 can pass very narrow

Trang 23

frequency bands of approximately 1% of the center

reso-nance frequency On the other hand, PZT ceramics whose

planar coupling coefficient is about 0.5 can easily pass a

band of 10% of the center resonance frequency The

sharp-ness of the passband depends on the mechanical quality

and well-defined frequency of the oscillator

A simple resonator is a thin disk electroded on its

plane faces and vibrating radially for applications in filters

whose center frequency ranges from 200 kHz to 1 MHz and

whose bandwidth is several percent of the center frequency

The disk diameter must be about 5.6 mm for a frequency of

455 kHz However, if the required frequency is higher

than 10 MHz, other modes of vibration such as the

thick-ness extensional mode are exploited, because of its smaller

size disk Trapped-energy type filters made from PZT

ceramics have been widely used in the intermediate

fquency range, for example, 10.7 MHz for FM radio

re-ceivers and transmitters By employing the trapped-energy

phenomenon, the overtone frequencies are suppressed The

plate is partly covered by electrodes of a specific area

and thickness The fundamental frequency of the

thick-ness mode beneath the electrode is less than that of the

unelectroded portion because of the extra inertia of the

electrode mass The longer wave characteristic of the

elec-trode region cannot propagate in the unelecelec-troded region

Higher frequency overtones can propagate into the

unelec-troded region This is called the trapped-energy principle

Figure 10 shows a schematic drawing of a trapped-energy

filter In this structure, the top electrode is split so that

cou-pling between the two parts is efficient only at resonance

More stable filters suitable for telecommunication systems

have been made from single crystals such as quartz or

LiTaO3

Piezoelectric Transformer

The transfer of vibrational energy from one set of

elec-trodes to another on a piezoelectric ceramic body can be

used to transform voltage The device is called a

piezo-electric transformer Recently, office automation

equip-ment that has a liquid crystal display such as notebook

type personal computers and car navigation systems has

been successfully commercialized This equipment that

uses liquid crystal display requires a very thin

trans-former without electromagnetic noise to start the glow of

Ceramic plateElectrode

Figure 10 Trapped-energy filter.

Low voltage input

High voltage output

Figure 11 Piezoelectric transformer.

a fluorescent back-lamp This application has recently celerated the development of piezoelectric transformers.Figure 11 shows the basic structure, where two differentlypoled parts coexist in one piezoelectric plate The plate haselectrodes on half of its major faces and on an edge Theplate is then poled in its thickness direction at one endand parallel to the long axis over most of its length A low-voltage ac supply is applied to the large-area electrodes at

ac-a frequency thac-at excites ac-a length extensionac-al mode nance Then, a high-voltage output can be taken from thesmall electrode and from one of the larger electrodes Fol-lowing the proposal by Rosen mentioned before, piezoelec-tric transformers of several different structures have beenreported (26) Multilayer type transformers are proposed toincrease the voltage step-up ratio (27) The input part has

reso-a multilreso-ayer structure reso-and hreso-as internreso-al electrodes, reso-and theoutput electrodes are formed at the side surface of the half

of the rectangular plate This transformer uses the electric transverse mode for the input and output parts

piezo-SAW Device

A surface acoustic wave (SAW), also called a Rayleigh wave,

is composed of a coupling between longitudinal and shearwaves in which the SAW energy is confined near the sur-face An associated electrostatic wave exists for a SAW on

a piezoelectric substrate that allows electroacoustic pling via a transducer The advantages of SAW technologyare that a wave can be electroacoustically accessed andtrapped at the substrate surface and its velocity is approx-

The SAW wavelength is of the same order of magnitude

as line dimensions that can be photolithographically duced, and the lengths for both short and long delays areachievable on reasonably size substrates (28,29)

pro-There is a very broad range of commercial applications,including front-end and IF (intermediate frequency) filters,CATV (community antenna television) and VCR (video cas-sette recorder) components, synthesizers, analyzers, andnavigators In SAW transducers, finger electrodes providethe ability to sample or tap the wave, and the electrodegap gives the relative delay A SAW filter is composed of

a minimum of two transducers A schematic of a simpleSAW bidirectional filter is shown in Fig 12 A bidirectionaltransducer radiates energy equally from each side of thetransducer Energy not received is absorbed to eliminatespurious reflection

Various materials are currently being used for SAW vices The most popular single-crystal SAW materials arelithium niobate and lithium tantalate The materials havedifferent properties depending on their cuts and the direc-tion of propagation The fundamental parameters are the

Trang 24

de-Input SAW Output

Interdigital electrodePiezoelectric substrate

Figure 12 Typical SAW bidirectional filter that consists of two

interdigital transducers.

SAW velocity, the temperature coefficient of delay (TCD),

the electromechanical coupling factor, and the propagative

loss Surface acoustic waves can be generated and detected

by spatially periodic, interdigital electrodes on the plane

surface of a piezoelectric plate A periodic electric field is

produced when an RF source is connected to the electrode,

thus permitting piezoelectric coupling to a traveling

sur-face wave If an RF source of a frequency f is applied to an

electrode whose periodicity is p, energy conversion from an

electrical to mechanical form will be maximum when

of the device SAW velocity is an important parameter that

determines the center frequency Another important

pa-rameter for many applications is the temperature

sensi-tivity For example, the temperature stability of the center

frequency of a SAW bandpass filter is a direct function of

the temperature coefficient for the velocity and delay time

of the material used The first-order temperature

coeffi-cient of delay time is given by

(1/t)(dt/dT) = (1/L)(dL/dT) − (1/Vs)(dVs/dT), (10)

s is defined

in terms of the change in SAW velocity that occurs when

the wave passes across a surface coated by a thin massless

conductor, so that the piezoelectric field associated with the

wave is effectively shorted-circuited The coupling factor

Table 5 Material Parameters for Representative SAW Materials

and the amount of signal loss between input and outputthat determines the fractional bandwidth versus minimuminsertion loss for a given material and a filter Propagativeloss, one of the major factors that determines the insertionloss of a device, is caused by wave scattering by crystallinedefects and surface irregularities Materials that have highelectromechanical coupling factors combined with smalltemperature coefficients of delay time are likely to be

a function of the cut angle and the propagative direction.The TCD is an indication of the frequency shift expectedfrom a transducer due to a temperature change and is also

a function of the cut angle and the propagative direction.The substrate is chosen on the basis of the device’s designspecifications for operating temperature, fractional band-width, and insertion loss

Table 5 shows some important material parameters ofrepresentative SAW materials Piezoelectric single crys-tals such as 128◦Y-X (128◦-rotated Y cut and X propagation)

sub-strates for VIF filters ZnO thin films c-axis oriented anddeposited on a fused quartz, glass, or sapphire substratehave also been commercialized for SAW devices

Actuators

Currently, another important application of piezoelectricmaterials exists in the actuator field (30) Using theconverse piezoelectric effect, a small displacement can beproduced by applying an electric field to a piezoelectric ma-terial Vibrations can be generated by applying an alter-nating electric field There is a demand in advanced preci-sion engineering for a variety of types of actuators thatcan adjust position precisely (micropositioning devices),suppress noise vibrations (dampers), and drive objects dy-namically (ultrasonic motors) These devices are used inareas, including optics, astronomy, fluid control, and pre-cision machinery Piezoelectric strain and electrostrictioninduced by an electric field are used for actuator applica-tions

Trang 25

Bimorph

Moonie

vz

vzz

vz

Figure 13 Structures of ceramic actuators.

Figure 13 shows the design classification of ceramic

ac-tuators Simple devices composed of a disk or a multilayer

type use the strain induced in a ceramic by the applied

elec-tric field directly Complex devices do not use the induced

strain directly but use the amplified displacement through

a special magnification mechanism such as a unimorph,

bimorph or moonie The most popularly used multilayer

and bimorph types have the following characteristics: The

but has advantages in generation force (1 kN), response

coupling factor k33(0.70) The bimorph type has a large

force (1 N), response speed (1 ms), lifetime (108cycles), and

in a 0.65 PMN–0.35 PT multilayer actuator made of 99

displacement is generated by a 100 V voltage, accompanied

by a slight hysteresis The transmited response of the

in-duced displacement after the application of a rectangular

field-induced strain of 0.1% along the length

Unimorph and bimorph devices are defined by the

num-ber of piezoelectric ceramic plates: only one ceramic plate

is bonded onto an elastic shim, or two ceramic plates are

bonded together The bimorph causes bending deformation

because each piezoelectric plate bonded together produces

extension or contraction in an electric field In general,

there are two types of piezoelectric bimorphs: the

antipar-allel polarization type and the parantipar-allel polarization type,

(a)

V

(b)

V

Figure 14 Two types of piezoelectric bimorphs: (a) antiparallel

polarization type and (b) parallel polarization type.

as shown in Fig 14 Two poled piezoelectric plates t/2 thick and L long are bonded so that their polarization directions

are opposite or parallel to each other In the cantilever morph configuration where one end is clamped, the tip dis-

metallic sheet (called a shim) is occasionally sandwichedbetween the two piezoelectric plates to increase reliability;the structure can be maintained even if the ceramics frac-ture Using the bimorph structure, a large magnification ofdisplacement is easily obtainable However, the disadvan-tages include low response speed (1 kHz) and low genera-tive force

A composite actuator structure called a “moonie” hasbeen developed to amplify the small displacements in-duced in piezoelectric ceramics The moonie consists of athin multilayer element and two metal plates that havenarrow moon-shaped cavities bonded together This devicehas characteristics intermediate between the conventionalmultilayer and bimorph actuators; it has an order of mag-

much larger generative force (100 N), and quicker response(100µs) than the bimorph.

Some examples of applications of piezoelectric and trostrictive actuators are described here The piezoelectricimpact dot-matrix printer is the first mass-produced de-vice that uses multilayer ceramic actuators (Fig 15) Theadvantages of a piezoelectric printer head compared toconventional magnetic type are low energy consumption,low heat generation, and fast printing speed Longitudi-nal multilayer actuators do not have a large displacement,and thus a suitable displacement magnification mecha-nism is necessary The displacement induced in a multi-layer actuator pushes up the force point, and its displace-ment magnification is carried out through hinge levers togenerate a large wire stroke When the displacement in

Trang 26

WireWire guide

Ink ribbonPaper

Platen

(b)

Figure 15 Impact dot-matrix printer head.

obtained; the magnification rate is 30 times

Bimorph structures are commonly used for VCR

head-tracking actuators because of their large displacements

An autotracking scan system uses a piezoelectric

actu-ator so that the head follows the recording track, even

driven in both still and quick modes As can be anticipated,

the bimorph drive is inevitably accompanied by torsional

motion A special mechanism has to be employed to

ob-tain perfectly parallel motion Piezoelectric pumps for gas

or liquid that use the alternating bending motion of the

bimorph have been developed for intravenous drip

in-jection in hospitals and for medication dispensing for

chemotherapy, chronic pain, and diabetes Piezoelectric

fans for cooling electronic circuits are made from a pair of

bimorphs that are driven out of phase so as to blow

effec-tively Furthermore, piezo-bimorph type camera shutters

have been widely commercialized by Minolta

Lenses and mirrors in optical control systems require

micropositioning, and even the shapes of mirrors are

ad-justed to correct image distortions For instance, a

space-qualified active mirror, called an articulating fold mirror,

uses six PMN electrostrictive multilayer actuators to

posi-tion and tilt a mirror tip precisely to correct the focusing

aberration of the Hubble Space Telescope

Piezoelectric actuators are also useful for vibrational

suppression systems in an automobile An electronic

controlled shock absorber was developed by Toyota

Figure 16 Bearingless rotor flexbeam and attached piezoelectric

strips.

Piezoelectric sensors that detecting road roughness arecomposed of five layers of 0.5-mm thick PZT disks Theactuator is made of 88 layers of 0.5 mm thick disks Under

magnified 40 times by a piston and plunger pin tion This stroke pushes the change valve of the dampingforce down and then opens the bypass oil route, leading to

combina-a decrecombina-ase in flow resistcombina-ance This electroniccombina-ally controlledshock absorber has both controllability and provides com-fort simultaneously

The U.S Army is interested in developing a rotor controlsystem for helicopters because a slight change in the bladeangle dramatically enhances controllability Figure 16shows a bearingless rotor flexbeam that has piezoelectricstrips attached Various types of PZT-sandwiched beamstructures have been investigated for such a flexbeam ap-plication and for active vibrational control

Ultrasonic Motors

An ultrasonic motor (USM) is an example of a piezoelectricactuator that uses resonant vibration Linear motion in ul-trasonic motors is obtained by frictional force from ellipti-cal vibration The motor consists of a high-frequency powersupply, a vibrator, and a slider The vibrator is composed of

a piezoelectric driving component and an elastic vibratorypart, and the slider is composed of an elastic moving partand a friction coat The characteristics of ultrasonic mo-tors are low speed and high torque compared to the highspeed and low torque of conventional electromagnetic mo-tors (30,31)

Ultrasonic motors are classified into two types: thestanding-wave type and the propagating-wave type Thedisplacement of a standing wave is expressed by

xs (x , t) = Acos (kx) cos (ωt); (15)for a propagative wave displacement is given by

xp (x , t) = Acos(kx − ωt)

= Acos(kx) cos(ωt) + Acos(kx − π/2) cos(ωt − π/2).

(16)

Trang 27

Vibratory piece Rotor

Figure 17 Vibratory-coupler type ultrasonic motor.

A propagating wave can be generated by superimposing

two standing waves whose phases differ from each other

is sometimes called a vibratory coupler or a “woodpecker”

type; a vibratory piece is connected to a piezoelectric driver,

and the tip portion generates a flat elliptical movement

(Fig 17) The vibratory piece is attached to a rotor or a

slider at a slight cant angle The standing-wave type has

high efficiency, up to 98% of theoretical However, a

prob-lem of this type is lack of control in both clockwise and

counterclockwise directions The principle of the

propaga-tive type is shown in Fig 18 In the propagating-wave type,

also called the “surfing-type,” a surface particle of the

elas-tic body draws an ellipelas-tical locus due to coupling of the

longitudinal and transverse waves This type generally

re-quires two vibrational sources to generate one propagating

wave; this leads to low efficiency (not more than 50%), but

it is controllable in both rotational directions An

ultra-sonic rotary motor is successfully used in an autofocusing

camera to produce precise rotational displacements The

advantages of this motor over the conventional

electromag-netic motor are silent drive (inaudible), thin motor design,

and energy savings

Tiny conventional electromagnetic motors, smaller than

1cm that have sufficient energy efficiency are rather

diffi-cult to produce Therefore, the ultrasonic motor is gaining

widespread attention Ultrasonic motors whose efficiency

is independent of size are superior in the minimotor area

A compact ultrasonic rotary motor as tiny as 3 mm in

dia-meter was developed by Uchino et al (32) The stator

con-sists of a piezoelectric ring and two concave/convex metal

end caps that have windmill-shaped slots bonded together,

so as to generate a coupled vibration of the up-down and

Figure 18 Principle of the propagating-wave type ultrasonic

motor.

torsional type Because the number of components and thefabrication process are minimized, the cost of fabricationwill decrease remarkably, and it can be disposable; this

is very suitable for medical catheter and endoscopic plications When driven at 160 kHz, a maximum speed of

The following key problems should be systematicallystudied in developing reliable ultrasonic motors: (1) de-velopment of low loss and high vibrational velocity piezo-electric materials; (2) piezoactuator designs that accountfor heat generation and degradation mechanisms; (3) USMdesigns, including displacement amplification mechanismsand frictional contact parts

BIBLIOGRAPHY

1 B Jaffe, W Cook, and H Jaffe, Piezoelectric Ceramics

Aca-demic Press, London, 1971.

2 W.G Cady, Piezoelectricity McGraw-Hill, NY, rev ed., Dover,

1964.

3 F Jona and G Shirane, Ferroelectric Crystals Pergamon

Press, London, 1962.

4 M.E Lines and A.M Glass, Principles and Applications of

Ferroelectric Materials Clarendon Press, Oxford, 1977.

5 IEEE Standard on Piezoelectricity IEEE, NY, 1978.

6 Landold and Boernstein, Numerical Data and Functional

Relationships in Science and Technology: Crystal and Solid State Physics, Vol.11 Springer-Verlag, Berlin, 1979.

7 W.A Smith, Proc SPIE 1733 (1992).

8 H Takeuchi, S Jyomura, E Yamamoto, and Y Ito, J Acoust.

Soc Am 74: 1114 (1982).

9 Y Yamashita, K Yokoyama, H Honda, and T Takahashi, Jpn.

J Appl Phys 20 (Suppl 20-4): 183 (1981).

10 Y Ito, H Takeuchi, S Jyomura, K Nagatsuma, and S Ashida,

Appl Phys Lett 35: 595 (1979).

11 L.E Cross, S.J Jang, R.E Newnham, S Nomura, and

18 Kistler, Stress Sensor, Production Catalog Switzerland,

19 Tokin, Gyroscope, Production Catalog Japan,

20 B.A Auld, Acoustic Fields and Waves in Solids 2e, Krieger,

Melbourne, FL, 1990.

21 G.S Kino, Acoustic Waves: Device Imaging and Analog Signal

Processing Prentice-Hall, Englewood Cliffs, NJ, 1987.

22 C.S Desilets, J.D Fraser, and G.S Kino, IEEE Trans Sonics

Ultrasonics, SU-25: 115 (1978).

23 T.R Gururaja, Am Ceram Soc Bull 73: 50 (1994).

24 F.S Foster, L.K Ryan, and D.H Turnbull, IEEE Trans

Ul-trasonics Ferroelectrics Frequency Control 38: 446 (1991).

Trang 28

25 Y.Ito, K Kushida, K Sugawara, and H Takeuchi, IEEE

Trans Ultrasonics Ferroelectrics Frequency Control 42: 316,

1995.

26 C.A Rosen, Proc Electron Component Symp., 1957, p 205.

27 S Kawashima, O Ohnishi, H Hakamata, S Tagami, A.

Fukuoka, T Inoue, and S Hirose, Proc IEEE Int Ultrasonic

Symp ’94, France, Nov 1994.

28 C Campbell, Surface Acoustic Wave Devices and Their Signal

Processing Applications Academic Press, San Diego, 1989.

29 H Matthews, Surface Wave Filters Wiley-Interscience, NY,

1977.

30 K Uchino, Piezoelectric Actuators and Ultrasonic Motors.

Kluwer Academic, Boston, 1997.

31 S Ueha and Y Tomikawa, Ultrasonic Motors Clarendon

This article explores piezoelectric ceramics analysis and

characterization The focus is on polycrystalline ceramics;

therefore, single crystals, polymeric materials, and

or-ganic /inoror-ganic composites are outside the scope of this

review To grasp the behavior of a piezoelectric

polycrys-talline ceramic thoroughly, a basic understanding of the

ceramic itself should not be overlooked To this end, we

have presented a brief introduction of the history of

piezo-electricity and a discussion on processing of the ceramic

and the development of the constitutive relationships that

define the behavior of a piezoelectric material We have

at-tempted to cover the most common measurement methods

and to introduce parameters of interest Excellent sources

for more in-depth coverage of specific topics can be found in

the bibliography In most cases, we refer to lead zirconate

titanate (PZT) to illustrate some of the concepts because it

is the most widely used and studied piezoelectric ceramic

to date

PIEZOELECTRIC MATERIALS: HISTORY

AND PROCESSING

Smart materials are materials that undergo

transforma-tions through physical interactransforma-tions An alternate definition

is that a smart material is a material that senses a change

in its environment and adapts to correct or eliminate such

a change by using a feedback system Piezoelectric

materi-als, shape-memory alloys, electrostrictive materimateri-als,

mag-netostrictive materials, and electrorheological fluids are

some examples of currently available smart materials

Piezoelectricity stems from the Greek word piezo for

pressure It follows that a piezoelectric material develops a

potential across its boundaries when subjected to a nical stress (or pressure), and vice versa, when an electricfield is applied to the material, a mechanical deformationensues Therefore, piezoelectric materials fall in the class

mecha-of smart materials Ferroelectricity is a subgroup mecha-of electricity, where a spontaneous polarization exists thatcan be reoriented by applying an ac electric field

piezo-Definition and History

Piezoelectricity is a linear effect that is related to the croscopic structure of a solid Some ceramic materials be-come electrically polarized when they are strained; this

mi-linear and reversible phenomenon is referred to as the

di-rect piezoelectric effect The didi-rect piezoelectric effect is

al-ways accompanied by the converse piezoelectric effect where

a solid becomes strained when placed in an electric field.The microscopic origin of the piezoelectric effect is thedisplacement of ionic charges within a crystal structure

In the absence of external strain, the charge distributionwithin the crystal is symmetrical, and the net electricdipole moment is zero However when an external stress isapplied, the charges are displaced, and the charge distribu-tion is no longer symmetrical A net polarization developsand results in an internal electric field A material can bepiezoelectric only if the unit cell has no center of inversion.Piezoelectricity is a property of a group of materials thatwas discovered in 1880 by Pierre and Jacques Curie dur-ing their study of the effects of pressure on the generation

of electrical charge by crystals such as quartz, tourmaline,and Rochelle salt In 1881, the term “piezoelectricity” wasfirst suggested by W Hankel, and the converse effect wasdeduced by Lipmann from thermodynamics principles Inthe next three decades, collaborations within the Europeanscientific community established the field of piezoelectri-

city, and by 1910, Voigt’s Lerbuch der Kristallphysic was

published and became a standard reference work ing the complex electromechanical relationships in piezo-electric crystals (1) However, the complexity of the science

detail-of piezoelectricity made it difficult for it to mature to anapplication until a few years later Langevin et al (2) de-veloped a piezoelectric ultrasonic tranducer during WorldWar I Its success opened up opportunities for piezoelectricmaterials in underwater applications and a host of otherapplications such as ultrasonic transducers, microphones,and accelerometers In 1935, Busch and Scherrer disco-vered piezoelectricity in potassium dihydrogen phosphate(KDP) The KDP family was the first major family of piezo-electrics and ferroelectrics discovered

During World War II, research in piezoelectric als expanded to the United State, the Soviet Union, andJapan Until then, limited performance by these materi-als inhibited commercialization, but that changed when amajor breakthrough came with the discovery of barium ti-tanate and lead zirconate titanate (PZT) in the 1940s and1950s, respectively These families of materials exhibitedvery high dielectric and piezoelectric properties Further-more, they offered the possibility of tailoring their behavior

materi-to specific responses and applications by using dopants

To date, PZT is one of the most widely used tric materials Most commercially available ceramics (such

Trang 29

O

Ti, Zr

Figure 1 Perovskite structure.

as barium titanate and PZT) are based on the perovskite

simplest arrangement where the corner-sharing

oxy-gen octahedra are linked together in a regular cubic

array; smaller cations (Ti, Zr, Sn, Nb, etc.) occupy the

central octahedral B site, and larger cations (Pb, Ba, Sr,

Ca, Na, etc.) fill the interstices beween octahedra in the

larger A site Compounds such as BaTiO3, PbTiO3, PbZrO3,

their high-temperature ferroelectric and antiferroelectric

phases have been extensively exploited This structure also

allows multiple substitutions at the A site and B site that

result in a number of useful though more complex

com-pounds such as (Ba,Sr)TiO3, (Pb,Sr)(Zr,Ti)O3, Pb(Fe,Ta)O3,

and (KBi)TiO3

Starting around 1965, several Japanese companies

fo-cused on developing new processes and applications and

opening new commercial markets for piezoelectric devices

The success of the Japanese effort attracted other nations,

and today the needs and uses extend from medical

applica-tions to the communicaapplica-tions field to military applicaapplica-tions

and the automotive field

A review of the early history of piezoelectricity is found

in the work of Cady (3), and in 1971, Jaffe et al published

the book Piezoelectric Ceramics (4) that is still one of the

most referenced works on piezoelectricity

Piezoelectric Ceramic Processing

The fabrication of most bulk piezoelectric ceramics starts

with powder preparation The powder is then pressed to

the required shapes and sizes, and the green shapes are

in turn processed into mechanically strong and dense

ce-ramics The more important processes that influence the

product characteristics and properties are powder

prepa-ration, powder calcining and sintering The next steps are

machining, electroding, and poling, the application of a dc

field to orient the dipoles and induce piezoelectricity

The most common powder preparation is the

mixed-oxide In this process, powder is prepared from the

ap-propriate stoichiometric mixture of the constituent oxides

Lead oxide, titanium oxide, and zirconium oxide are the

main compounds for, lead zirconate titanate (PZT)

De-pending on the application, various dopants are used to

tai-lor the properties of interest PZT ceramics are rarely used

Wet millingZirconia media + Ethanol

24 hrs

Drying at 80°C, 12 hrsSieving for better mixing andsize reduction

Ready for calcining

PbO, TiO2, ZrO2dopants if neededMixing of oxides:

Figure 2 Mixed-oxide route for preparing PZT.

without adding of dopants to modify some of their ties A-site additives tend to lower the dissipation factor,which affects heat generation, but also lower the piezo-electric coefficients; for this reason they are used mostly inultrasonics and other high-frequency applications B-sitedopants increase the piezoelectric coefficients but also in-crease the dielectric constant and loss B-site doped ceram-ics used are as actuators in vibrational and noise control,benders, and optical positioning applications

proper-Figure 2 shows a flowchart of the mixed-oxide route formaking PZT ceramics The powders can be mixed by dryball milling or wet ball milling; both methods have advan-tages and disadvantages: wet ball milling is faster thandry milling; however, the disadvantage is the added step

of liquid removal The most common method for makingPZT ceramics is wet ball milling; ethanol and stabilizedzirconia media are added for wet milling A vibratory millmay be used rather than a conventional ball mill; Herner(5) showed that this process reduces the risk of contamina-tion by the balls and the jar Zirconia media are used to re-duce the contamination risks further Calcination is a verycrucial step in processing PZT ceramics; it is importantfor crystallization to be complete because the perovskitephase forms during this step The goals are to remove anyorganics, water, or other volatiles left after mixing; to re-act the oxides to form the desired phase composition beforethe ceramic is processed into useful devices; and to reducevolume shrinkage and allow for better homogeneity duringand after sintering

After calcining, a binder is added to the powder, andthen the mixture is shaped usually by dry pressing in a diefor simple shapes, or extrusion, or casting for more compli-cated bodies Next, the shapes are sintered—placed in anoven for binder burnout and densification

Trang 30

The major problem in sintering a PZT ceramic is the

prob-lem, the PZT samples are sintered in the presence of a lead

source, such as PbZrO3, and placed in closed crucibles

Sat-uration of the sintering atmosphere with PbO minimizes

lead loss from the PZT bodies Sintering can now be

Despite precautions, usually 2–3% of the initial lead

con-tent is lost

After cutting and machining into desired shapes,

elec-trodes are applied, and a strong dc field is used to orient

the domains in the polycrystalline ceramic Dc poling can

be done at room temperature or at higher temperatures,

depending on the material and the composition The poling

process only partially aligns the dipoles in a polycrystalline

ceramic, and the resulting polarization is lower than that

of single crystals

This processing technique presents many uncertainties;

the existence of a wide number of other fabrication

tech-niques is an indication that there is a great need for the

production of reliable PZT ceramics whose properties and

microstructure are optimal One problem often

encoun-tered is deviation from stoichiometry This problem is often

due to impurities in the raw materials as well as the lead

loss during sintering, and invariably results in substantial

alterations of the PZT properties As a result, the

elas-tic properties can vary as much as 5%, the piezoelectric

properties 10%, and the dielectric properties 20% within

the same batch (6) The piezoelectric and dielectric

prop-erties generally suffer also if there is any lack of

homo-geneity from poor mixing It is important then that the

constituent oxides be intimately mixed In the method

de-scribed before, however, the constituents are solid solutions

and it has been shown that intimate mixing of solid

so-lutions is difficult if not impossible More information on

the preparation of piezoelectric ceramics can be found in

Jaffe et al (4), and Moulson and Herbert (7) Other

pro-cessing methods, including hydrothermal propro-cessing and

coprecipitation methods, are described in (8–10) Noted

that there has been a great deal of development in

pow-der processing, shaping, and sintering (11–13) that has

re-sulted in further expanding the application of piezoelectric

ceramics

Ferroelectricity

Some piezoelectric materials are also ferroelectric A

fer-roelectric material possesses spontaneous polarization

whose direction can be reversed by applying a

realiz-able electric field across some temperature range Most

be-low which they are polar and above which they are not

lin-early decreases above it according to the Curie–Weiss law

(4,7) The very large permittivity values that are

charac-teristic of ferroelectric materials are greatly exploited in

many applications, most widely in the multilayer-capacitor

industry

Applying a large alternating electric field reverses

the polarization, and this gives rise to the ferroelectric

Figure 3 P–E hysteresis loop of a poled piezoelectric ceramic.

hysteretic loop that relates polarization P to applied tric field E A typical field-polarization loop is illustrated

elec-in Fig 3 For large signals, both the electric displacement

D and the polarization P are nonlinear functions of the

field E They are related to each other through the linear

equation

D i = P i + ε0E i , (1)

C/ Vm) The second term in Eq (1) is negligible for most

ferroelectric ceramics, and a D–E loop and P–E loop come interchangeable Two key characteristics of the P–E

is the field at which polarization is zero Pris the value ofthe polarization when the electric field is zero Once thefield is switched off, the material’s polarization is equal to

determined A loop is said to be saturated once the values

of Prand Ecno longer vary

Generally, the existence of the P–E loop is considered

evidence toward establishing that a material is tric A Sawyer–Tower circuit (14), or a modified version of

ferroelec-it, is commonly used to obtain a P–E loop An ac voltage is

applied to the electroded sample; the resulting chargestored on the sample is determined by a large referencecapacitor placed in series with the sample An electrome-ter can be used to detect the voltage across the capacitor; bymultiplying this voltage by the value of the reference capac-itor, the charge across the sample results The capacitance

of the reference capacitor should be 100 to 1000 times thevalue of the capacitance of the sample Note that ferroelec-tric hysteretic loops are both frequency- and temperature-dependent

In addition to the P–E loop, polarization switching leads

to strain–electric field hysteresis A typical strain–field

Trang 31

Electric field

Figure 4 Butterfly loop indicating switching.

response curve is shown in Fig 4 The shape resembles

that of a butterfly, and it is often referred to as the

“but-terfly loop.” As the electric field is applied, the converse

piezoelectric effect dictates that a strain results As the

field is increased, the strain is no longer linear with the

field, as domain walls start switching

For more sources on ferroelectricity, the reader should

consult the bibliography (15–19)

PIEZOELECTRIC CONSTITUTIVE RELATIONSHIPS

An understanding of piezoelectricity begins with the

struc-ture of the material To explain it better, let us consider a

in average diameter) from a polycrystalline ceramic This

crystal is made up of negatively and positively charged

atoms that occupy specific positions in a repeating unit

or cell The specific symmetry of the unit cell determines

the possibility of piezoelectricity in the crystal All crystals

can be divided into 32 classes or point groups (from seven

basic crystal systems: triclinic, monoclinic, orthorhombic,

tetragonal, rhombohedral, hexagonal, and cubic) Of the

32 classes, 21 do not possess a center of symmetry, and 20

are piezoelectric (although one class lacks a center of

sym-metry, it is not piezoelectric because of the combination of

other symmetry elements) The lack of a center of

symme-try means that a net movement of positive and negative

ions with respect to each other as a result of stress

pro-duces an electric dipole Because the ceramic is composed

of randomly oriented piezoelectric crystallites, it is

inac-tive, that is, the effects of the individual crystals cancel

each other and no discernable piezoelectricity is present

Regions of equally oriented polarization vectors are known

as domains “Poling” is a commonly used method to orient

the domains by polarizing the ceramic through the

appli-cation of a static electric field Electrodes are applied to

Figure 5 Poling of a piezoelectric, ferroelectric ceramic.

the ceramic, and a sufficiently high electric field is appliedsuch that the domains rotate and switch in the direction ofthe electric field Full orientation of all domains never re-sults; however, the polycrystalline ceramic exhibits a largepiezoelectric effect During this process, there is a smallexpansion of the material along the poling axis and a con-traction in both directions perpendicular to it (see Fig 5).Due to large number of allowable polar directions such asnear the morphotropic phase boundary (where the Zr to

Ti ratio is 48 to 52), the maximum deviation of the polaraxis of a grain from the average polar direction is smaller,and the reduction of polarization is minimized, assumingoptimum alignment

Constitutive Relationships

When writing the constitutive equations for a tric material, account must be taken of changes of strainand electrical displacement in three orthogonal directionscaused by cross-coupling effects due to applied electricaland mechanical stresses Tensor notation is first adopted,and the reference axes are shown in Fig 6 The state of

state of stress is also described by a second-rank tensor

strain tensor, compliance s i jkl , and stiffness c i jkl, are thenfourth-rank tensors The relationship between the electric

D i(also a first-rank tensor) is the permittivity ε i j, which

is a second-rank tensor Therefore the piezoelectric

36

4

1

52

Figure 6 Reference axes.

Trang 32

where d i jk , d i jkare the piezoelectric constants (third-rank

tensor) Superscripts T and E indicate that the dielectric

under conditions of constant stress and constant electric

field, respectively In general, a first-rank tensor has three

components, a second-rank tensor has nine components,

a third-rank tensor has 27 components, and a fourth-rank

tensor has 81 components Not all of the tensor components

are independent

Both of these relationships depend on orientation; they

describe a set of equations that relate these properties in

different orientations of the material The crystal

symme-try and the choice of reference axes reduce the number

of independent components A convenient way of

describ-ing them is by usdescrib-ing axis directions, as given by Fig 6

The convention is to define the poling direction as the

3 axis, the shear planes are indicated by the subscripts

4, 5, and 6 and are perpendicular to directions 1, 2, and 3,

respectively This simplifies the notations introduced

be-fore, where a 3-subscript tensor notation (i , j, k = 1, 2, 3)

(i , j = 1, 2, 3) is replaced by a 1-subscript matrix notation

(i = 1, 2, 3, 4, 5, 6) A shear strain such as S4is a measure

of the change of angle between the two initially

orthog-onal axes in the plane perpendicular to axis 1 The first

subscript of the d constant gives the “electrical” direction

(field or dielectric displacement), and the second gives the

component of mechanical deformation or stress The

pla-nar isotropy of poled ceramics is expressed in their

field parallel to the poling axis 3 interacts in the same way

with axial stress along either the 2 axis or the 1 axis) and

d24 = d15(an electric field parallel to the 2 axis interacts in

the same way with a shear in the 2,3 plane as a field along

the 1 axis with a shear in the 1,3 plane) Similar

relation-ships hold for the elastic constants because of isotropy in

the plane perpendicular to the polar axis

Property Matrix for a Poled Piezoelectric Ceramic

A piezoelectric ceramic has only one type of piezoelectric

matrix, regardless of the symmetry of the constituent

crys-tals The ceramic is initially isotropic This isotropy is

destroyed in the poling direction The material is

trans-versely isotropic in the directions perpendicular to the

pol-ing direction The symmetry elements are an axis of

ro-tation of infinite order in the direction of poling and an

infinite set of planes parallel to the polar axis as reflection

planes In crystallographic notation, this symmetry is

crystal class, 6 mm

The elastic, dielectric, and piezoelectric matrices for the

cylindrical symmetry of poled PZT are shown in the

follow-ing equations Matrices analogous to the piezoelectric also

in the next section)

piezoelectric charge coefficients (d31and d33), the

piezoelec-tric voltage coefficients ( g31and g33), and the piezoelectric

coupling factors (k31, k33, kp, and kt) The d coefficient is

the proportionality constant between electric displacementand stress, or strain and electric field [Eqs (2) and (3)]

High d coefficients are desirable in materials used as

actu-ators, such as in motional and vibrational applications The

g coefficient is related to the d coefficient by the following

expression:

d mi = ε T

where m , n = 1, 2, 3 and i = 1, 2, 6 High g coefficients

are desirable in materials to be used as sensors to producevoltage in response to mechanical stress

The piezoelectric coupling factor k is a measurement of

the overall strength of the electromechanical effect It isoften defined as the square root of the ratio of electrical

Trang 33

energy output to the total mechanical energy input (in the

direct effect) or the mechanical energy available to the total

electrical energy (in the converse effect) The value of k is,

of course, always less than unity because energy conversion

is always incomplete

Other important properties of PZT are the dielectric

con-stant is a measure of the charge stored on an electroded

material brought to a given voltage The dielectric constant

constant K (often referred to as just “the dielectric

ac field, the dielectric constant has both a real part and an

imaginary part; the loss tangent is defined as the ratio of

the imaginary part to the real part

The values of these constants depend on the PZT

com-position As an example, the d constants, g constants,

and the dielectric constant for compositions near the

mor-photropic phase boundary show their highest values on the

tetragonal side of the transition (4) Then, it is possible to

tune the values of these properties for most compositions;

one way to achieve this is by adding dopants to the PZT

formulation

Resonant Method and Equivalent Circuit

Resonance Method Any body has certain characteristic

frequencies at which it prefers to resonate When excited

at this resonant frequency fr, the body will resonate freely

at a greater amplitude than at other frequencies

Follow-ing this resonant frequency is an antiresonant frequency

the oscillatory amplitude is at a minimum Piezoelectric

ce-ramics are no different, and measuring these characteristic

frequencies provides the means to evaluate the

piezoelec-tric and elastic properties of the ceramic Different modes

of vibration of the ceramic, such as thickness or planar, give

insight to the different constants for that mode A typical

resonance plot of impedance versus frequency for a

piezo-electric ceramic near a resonance is shown in Fig 7

of maximum impedance

At resonance, a piezoelectric element may be modeled

by the equivalent circuit shown in Fig 8 This circuit,

com-monly referred to as Van Dyke’s model, is recommended

by the IEEE Standard on Piezoelectricity (20) An

alter-nate model, proposed by Sherrit et al (21), elimialter-nates

components as complex to characterize better the losses

of certain piezoelectric elements, especially polymers All

between these two frequencies, the ceramic behaves

in-ductively This model is valid only near the resonance

Additionally, the resonance must be sufficiently isolated

from other modes to eliminate the effects of any adjacent

modes To ensure that the resonance is isolated, sample

geometry must be chosen carefully Geometries suitable

for measuring the different piezoelectric and elastic

coef-ficients are presented in Table 1 Fixturing of the sample

Figure 7 Impedance of a piezoelectric ceramic at resonance.

should not impose any constraints on the vibration of theceramic This can be accomplished by using a point holderpositioned at a node of vibration All leads should also beshielded up to the contact point, as much as possible, toavoid any stray capacitances that may arise

Earlier literature has suggested several circuits for

These circuits usually consist of an oscillator for excitingthe sample, a voltmeter or other device for measuring cur-rent through the circuit, and additional discrete compo-

nents To find fr, the frequency of the oscillator is varieduntil the maximum current is detected through the cir-

cuit Similarly, for fa, the frequency of minimum current isdetermined Note that there are actually six characteristicfrequencies that may be identified for a particular reso-

resonant frequency and series resonant frequency IEEEStandard 177 (23) identifies these six frequencies and es-tablishes that for many cases, including piezoelectric ce-

films, this assumption can introduce appreciable errors,

so the six frequencies should be considered separately The

deter-mined by substituting an adjustable resistor into the cuit for the ceramic at the previously identified frequencyand adjusting the resistance until the voltmeter reading

cir-is the same as for the ceramic Today, fully integrated

Trang 34

Table 1 Sample Geometries for Measuring Material Properties

Dimensional Long, slender, length Thin, flat plate, thickness poled; Thin flat disc, thickness poled requirements poled rod; l > 3d l > 3 5 t, w d > 10 t

impedance analyzers are commercially available to make

this type of measurement, allow the researcher to choose

an equivalent circuit model, and report the values of the

and fa Commercial off- the shelf software is also available

now which can be used in conjunction with an analyzer

to evaluate the impedance information and calculate the

relative material properties of a piezoelectric device (26)

These tools can aid the researcher in evaluating material

properties, however, a basic understanding of piezoelectric

behavior is an important foundation that should not be

overlooked

Measuring Material Properties Capacitance

measure-ments are usually carried out at 1 kHz and at low

exci-tatory voltages (mV level) Although research has shown

that capacitance and loss vary with excitation voltage and

frequency (27,28), the 1-kHz, low-voltage measurement is

used to determine material properties The free relative

dielectric constant K Tis defined as the ratio of the

permit-tivity of the material to the permitpermit-tivity of free space It is

calculated from

K T= tC

Table 2 Typical Properties of Common Piezoelectric Materials

where t is the distance between electrodes in meters, C

in meters2 The loss tangent, tanδ, is defined as the ratio

of resistance to reactance in the parallel equivalent cuit of Fig 9b It is a measure of the dielectric losses in thematerial and therefore, also a measure of the heat generat-ing capacity of the ceramic when operated under dynamicconditions This is a direct measurement and is usuallyformed at the same conditions as the capacitance measure-ment

33 subscripts are for length extensional and thickness

cal-culated from the frequencies of minimum and maximumimpedance and are given by the equations

Trang 35

2 fr

and can be approximated by

kpf2− f2r

f2 r

Elastic compliance is the ratio of a material’s change in

dimensions (strain) relative to an externally applied load

(stress) This is the inverse of Young’s modulus For a

piezo-electric material, the compliance depends on whether the

strain is parallel or perpendicular to the poling axis and

the electrical boundary conditions Elastic constants are

calculated from the following equations:

whereρ is the density of the material in kg/m3, l is the

dis-tance between electrodes, and w is the width of the ceramic

The superscripts D and E stand for constant electric

dis-placement (open circuit) and constant electric field (short

circuit), respectively

ap-plied electric field to the strain, can be calculated from

the coupling, the elastic coefficients, and the dielectric

coefficients by the following equations:

do not depend on the dimensions of the material; ever, they vary with the degree of polarization of the ce-ramic They also do not provide the sign of the coefficient,which must be determined by direct measurements The

series equivalent circuit of Fig 9a is given by

a known input to the ceramic, either an electric field or aforce, and record the corresponding output, either a defor-mation or a charge under various conditions These meth-ods are in contrast to the bulk material characterizationusing the electrical resonance techniques described before.Many times, direct measurements are carried out on a cera-mic that has been configured as a sensor or actuator Typi-cal processing may include electroding, laminating, apply-ing preload, mounting, and other assembly procedures toadapt the material effectively for use as a sensor or actu-ator These measurements aid the researcher in modelingthe behavior of the piezoelectric device and allow efficientintegration of the devices into real-world applications.Displacements of piezoelectric actuators are measured

to determine the magnitude and sign of the relationshipbetween the applied electric field and the strain developed,that is, the converse effect For a PZT wafer, this corres-

ponds to the d i jcoefficient; however, for bending type ators, this relationship does not correlate directly with any

actu-of the measured properties for out-actu-of-plane bending usingthe resonance techniques Based on Eqs (10)–(15), it can be

the strain is a function only of the product of the applied

field E i and the d i jcoefficient

Careful attention must be paid to the boundary conditions

of the ceramic to ensure that this assumption is valid

In a plot of the strain as a function of applied field, the

Trang 36

slope yields an average value of d i j Typically, these

mea-surements are made by using a noncontacting

displace-ment transducer (29) to reduce the effects of loading on the

actuator Laser-based and other optical or capacitive

dis-placement measurement techniques are most commonly

used (30–32) Displacements may range from submicron

levels for single PZT wafers to the centimeter level for

bending type actuators For very small displacements, an

optical-lever type measurement system or interferometric

techniques (33) have been used to resolve the displacement

of the ceramic Direct application of either foil or optical

strain gages has also been used for measuring the

actu-ator strain These measurements may be either static or

dynamic, depending on the measurement system and the

intended application of the ceramic If dynamic

measure-ments are made, excitatory frequencies should be at least

an order of magnitude less than any resonant frequency of

the device to ensure linear behavior and boundary

condi-tions suitable for the intended measurement

Another direct method used to measure piezoelectric

constants is based on the direct piezoelectric effect (22,34)

Here, a known load is either applied to or lifted off a

cera-mic at rest The resulting charge, which accumulates on

the electrodes, is then measured as a voltage across a

capa-citor in parallel with the ceramic, or the current from the

ceramic can be integrated directly If E iis 0 (short circuit),

then Eq (2) reduces to

Knowing the applied stress and measuring the electric

If a piezoelectric ceramic is immersed in a liquid and the

pressure of the liquid is varied, then the piezoelectric

large capacitor in parallel with the ceramic This coefficient

represents the response of the ceramic to hydrostatic

pres-sure applied equally to all axes Convention has dictated

that electrodes are perpendicular to the 3 direction for the

Figure 10 Strain hysteresis of a

piezoelec-tric ceramic unimorph.

coefficients for a ceramic by the equation,

The frequency response of the device may be obtained byvarying the frequency of the excitatory voltage to the cera-mic while measuring the displacement Typical resonantfrequencies of bulk ceramic material are in the kilohertz

to megahertz range depending on the mode of vibration,whereas resonant frequencies of bender types (unimorph

or bimorph) may be less than 100 Hz For maximum strain,

a piezoelectric actuator can be excited at its natural quency; however, this nonlinear behavior must be takeninto account if the actuator is to be used across a range

fre-of frequencies Careful attention must also be paid tothe instrumentation system’s dynamic response in bothamplitude and phase distortions, when making dynamicmeasurements Measurement systems have their own fre-quency response characteristics which must be separatedfrom the response of the ceramic under test

Hysteresis is a phenomenon that is present in all electric materials Hysteretic behavior is due to the lossynature of the ceramic where the current trails the applied

material For actuators, this means that the absolute placement depends on the excitatory voltage and frequencyand also on whether the voltage is increasing or decreas-ing To characterize the amount of hysteresis in a ceramic,

a sinusoidal voltage is applied to the device, and the placement is recorded By plotting the displacement versusdriving voltage, as shown in Fig 10, the hysteretic behav-ior of the ceramic can be observed The amount of hystere-sis (usually expressed in percent) is defined as the largestdifference between the maximum and minimum displace-ment for any voltage divided by the total displacement Ofnote in Fig 10 is the fact that, as the peak voltage is in-creased, the amount of hysteresis also increases for anygiven voltage

dis-Generally, piezoelectric ceramic actuators exhibit adecrease in their displacement for a given excitatory

Trang 37

Stress, F/A

Increasingapplied field

x

Figure 11 Typical stress/strain relationship for a piezoelectric

ceramic.

voltage, as they are loaded This relationship can be seen in

Eq (3), when T k= 0 As the load is increased, the

displace-ment eventually reaches zero, and the actuator provides

only a force output This force is known as the blocked

force, and it is the maximum amount of force that the

ac-tuator can produce at that voltage To characterize this

relationship, the actuator is loaded with a load less than

the blocked force, and the displacement is measured If the

load is varied, then the force/displacement relationship can

be determined (Fig 11) To determine the blocked force,

the actuator must be rigidly held so as not to deform, and

the force output is measured by using a load cell or other

force-measuring device Because the displacement of some

piezoelectric actuators is quite small, this measurement

calculated by the equations

FB= E3d33wl

sE 33

FB= E3d31wt

sE 11

where E is the applied field; and l, w, and t are the length,

width, and thickness of the ceramic, respectively Equation

(34) applies to the thickness extensional mode and Eq (35)

applies to the length extensional mode

Actuators that have greater displacements lend

them-selves better to blocked force measurement (such as domed

prestressed actuators or unimorph/bimorph type

actu-ators) The blocked force may also be determined by

extrapolating the force–displacement relationship to zero

displacement if a true blocked force measurement is not

practical In most applications, actuators operate

some-where between the free (unloaded) state and the

com-pletely constrained state

It has been previously reported that a constant preload

applied to a piezoelectric actuator can actually increase

the displacement of the ceramic, compared to an unloaded

specimen (34–36) This may result from simply reducing

the compliance or mechanical play in a PZT assembly or

may be a real increase in the d coefficient This effect

reaches a maximum and then starts to cause a decrease inthe coefficient as the preload is increased up to the blockedforce

Temperature effects on the piezoelectric coefficients ofceramics may also be evaluated Usually, ceramics must

be used well below their Curie temperatures to maintainpolarization The respective Curie temperatures for hardand soft PZTs are of the order of 360◦C (680◦F) and 330◦C

cryogenic levels, the piezoelectric coefficients generally crease as temperature decreases This effect can be exper-imentally quantified through either resonance techniques

de-or direct measurements across the desired temperaturerange (34)

The power required to drive a piezoelectric ceramic can

be calculated from the following equation:

when the ceramic is modeled as in Fig 9a where f is the

Typically, it is assumed that both the capacitance and losstangent of the ceramic are constant when using Eq (36).Doing so can lead to large errors when estimating thepower consumption of a ceramic To avoid these errors, ei-ther the voltage and current supplied to the ceramic should

be measured to provide the power consumption directly, orthe variation of capacitance and loss of the material asfunctions of applied field and frequency must be quanti-fied and incorporated into Eq (36) (28) A number of re-searchers have investigated the power consumption char-acteristics of PZT actuators used to excite a host structure(27,37,38) and found a coupling between the mechani-cal motion of the structure and the electrical character-istics of the piezoelectric actuator Research by Brennanand McGowan (27) shows that the power consumption ofpiezoelectric materials used for active vibrational control

is independent of the coupling effects of the host structure

when the structure is completely controlled From these

findings, they conclude that the power requirements of thepiezoelectric actuator depend only on its geometry and ma-terial properties and the driving voltage and frequency ofthe control signal Research (23) has indicated that bothcapacitance and resistance are nonlinear functions of thepeak amplitude and frequency of the excitatory voltage

In time, piezoelectric effects imparted through polingdegrade Aging of piezoelectric ceramics, like many othermaterials, is logarithmic with time In most ceramics, ainitial performance levels can be recovered by simply re-poling the sample Aging levels depend on the composition;the coupling coefficient of a soft PZT composition ages at arate of –1% per time decade versus –2% for a hard compo-sition Degradation of piezoelectric behavior also depends

on the level of stress to which the ceramic is subjected.High stress levels can lead to switching of the polarizationand eventually depoling of the ceramic High stresses alsoinduce microcracking, which can lead to ceramic breakageand failure

Trang 38

The methods outlined before can be used either

sep-arately or together to investigate the dielectric,

piezoel-ectric, and elastic properties of a ceramic Resonant

tech-niques, which are the preferred method of measurement

in the IEEE standard, are easy to implement, and the

as-sociated frequencies can be measured accurately There is

even commercially available hardware and software to

as-sist in these measurements and the evaluation of material

properties However, these methods do not explain any

nonlinear behavior that is present in the ceramic

Depen-dence of material properties on the frequency and

am-plitude of the applied voltage are among these nonlinear

effects Direct measurements of the piezoelectric

con-stants can quantify the material properties under different

operating conditions and provide insight beyond the

stan-dard linear behavior predicted by resonance techniques

These methods though, are usually more rigorous in their

requirements for material handling and instrumentation

Modeling of Piezoelectric Ceramics

There are a host of applications for piezoelectric

materi-als, and although they have been studied for more than

a century, potential for improvement and innovation still

persists Modeling of piezoelectric ceramics and their

prop-erties affords a way to accelerate materials improvement

and aid in device design and development For that reason,

we would be remiss not to mention it, albeit briefly This

introduction is in no way meant as a comprehensive review

of the vast area of modeling of piezoelectricity; however the

references cited provide a good starting place Care must be

taken to differentiate between modeling the piezoelectric

material and modeling a “piezoelectric structure;” often, a

piezoelectric material is laminated or bonded to a substrate

as a unimorph or bimorph

A number of researchers experimented with

com-mercial packages have limitations Other groups have

written their own codes and achieved varying degrees of

success (40–43) Finite element schemes that combined

piezoelectric and acoustic elements proved useful in

char-acterizing the electromechanical behavior of piezoelectric

transducers (44) Most of these schemes are restricted

because they assume linearity of the coefficients P´erez

et al expanded on these models by including nonlinear

ele-ments in the equivalent circuit (45) Models of the

nonlin-ear hysteretic behavior of piezoelectric materials are

abun-dant in the literature and can be categorized on the basis of

the dimensional scale they probe Microscopic models stem

primarily from energy relationships applied at the atomic

or molecular level (46) Macroscopic models (47–49) often

use empirical relationships to describe the behavior of the

bulk material Both methods have their advantages and

disadvantages; microscopic models require a great number

of parameters, often not available, and macroscopic

mod-els do not consider the underlying physics A number of

authors proposed a third approach, a mesoscale or

semimi-croscopic model that combines the advantages of the

pre-vious methods, thus allowing a better way to model

hys-teretic behavior This is accomplished by starting out from

energy principles applied at the microscopic level, then

using a relatively small number of parameters to simulatethe behavior of bulk ceramics (50,51)

CONCLUSION

Characterization of the elastic, dielectric and mechanical properties of piezoelectric ceramics is crucialfor several reasons First, investigations of the materialproperties provide a link between the manufacturing pro-cess and ceramic performance This enables the developer

electro-of the materials to adjust the manufacturing process electro-of theceramic to produce tailored materials Second, the engi-neer can investigate prospective materials for applicability

to a specific need Material parameters obtained throughcharacterization can also be used to develop and validateanalytical models of the ceramics Insights gained throughcharacterization have led to many new devices and uses.For example, investigation of the hydrostatic coefficients ofPZT and those of the piezoelectric polymer polyvinylidene

figure of merit and led to composite research to combineboth materials in a superior device that fits underwaterand hydrophone applications better More than a centuryafter their discovery, piezoelectric ceramics have becomecommercially viable Researchers continue diligently touncover novel ways to characterize the complex electrome-chanical properties, and as they do so, new processingmethods and applications are revealed Recently, as an ex-ample, researchers at MIT successfully grew piezoelectricsingle crystals (52) that opened opportunities for newerapplications Published articles on composite processingand characterization have also become more abundant.Without question, piezoelectric ceramics have secured

a permanent place in the field of material science andengineering

ACKNOWLEDGMENT

The authors express their sincere appreciation to Dr.Jeffrey A Hinkley (NASA Langley Research Center) forhis review of the manuscript and his helpful comments

3 W.G Cady, Piezoelectricity; An Introduction to the Theory and

Applications of Electromechanical Phenomena in Crystals.

Dover, NY, 1964.

4 B Jaffe, W.R Cook, Jr., and H Jaffe, Piezoelectric Ceramics Academic Press, London, NY, 1971.

5 S.B Herner, Thesis, Pennsylvania State University, 1993.

6 Measurement of Properties of Piezoelectric Ceramics, Sensor Technology Limited, BM91-309, Manufacturer Handbook.

7 A.J Moulson and J.M Herbert, Electroceramics: Materials,

Properties, Applications Chapman and Hall, London, NY,

1992.

Trang 39

8 Q.F Zhou, H.L.W Chan, and C.L Choy, J Mater Process.

Technol 63, (1–3): 281–285 (1997).

9 Z Ounaies, Thesis Pennsylvania State University, 1995.

10 J.P Witham, Hydrothermal Preparation and Fabrication of

Lead Zirconate Titanate (PZT) Ceramics the Pennsylvania

State University, 1993.

11 C Near, G Shmidt, K McNeal, and R Gentilman, SPIE 5th

Annu Symp Smart Struct Mater Proc., San Diego, 1998,

Vol 3326, pp 323–331.

12 L.M Levinson, Electronic Ceramics: Properties, Devices, and

Applications General Electric Company, Schenectady, NY,

1988.

13 ACX Controls Expert, www.ACX.com.

14 C.B Sawyer and C.H Tower, Phys Rev 35: 269–273 (1930).

15 M.E Lines and A.M Glass, Principles and Applications of

Fer-roelectrics and Related Materials Clarendon, Oxford, 1979.

16 Y Xu, Ferroelectric Materials and Their Applications

North-Holland, Amsterdam, 1991.

17 G.A Smolenskii, V.A Bokov, V.A Isupov, N.N Krainik, R.E.

Pasynkov, and A.I Sokolov, Ferroelectrics and Related

Mate-rials Gordon and Breach, NY, 1984.

18 J.C Burfoot, Ferroelectrics: An Introduction to the Physical

Principles Van Nostrand, London, 1967.

19 ANSI/IEEE Std 180-1986, IEEE Standard Definitions of

Pri-mary Ferroelectric Terms The Institute of Electrical and

Elec-tronics Engineers, Inc., NY, 1986.

20 IEEE Standard on Piezoelectricity (IEEE Standard 176-1987).

Institute of Electrical and Electronic Engineers, NY, 1987.

21 S Sherrit, H.D Wiederick, B.K Mukherjee, IEEE Ultrasonics

Symp Proc., Ontario, Canada, 1997, pp 931–935.

22 W.P Mason and H Jaffe, Proc IRE 42: 921–930 (1954).

23 IEEE Standard Definitions and Methods of Measurement for

Piezoelectric Vibrators (IEEE Standard 177-1966) Institute of

Electrical and Electronic Engineers, NY, 1966.

24 K.W Kwok, H.L Chan, and C.L Choy, IEEE Trans.

Ultrasonics Ferroelectrics Frequency Control 44: (4); 733–742

(1997).

25 Procedures for Measuring Properties of Piezoelectric

Ceram-ics, Morgan Matroc Inc., Technical Publication TP-234.

26 Piezoelectric Resonance Analysis Program, TASI Technical

Software (1996).

27 M.C Brennan and A.M McGowan, SPIE 4th Annu Symp.

Smart Struct Mater Proc San Diego, 1997, Vol 3039,

pp 660–669.

28 T Jordan, Z Ounaies, J Tripp, and P Tcheng, Mater Res Soc.

Symp Proc 604: 203–208 (2000).

29 J.T Dawley, G Teowee, B.J.J Zelinski, and D.R Uhlmann,

Piezoelectric Characterization of Bulk and Thin Film

Ferro-electric Materials Using Fiber Optics, MTI Instruments Inc.,

33 H.D Wiederick, S Sherrit, R.B Stimpson, and B.K.

Mukherjee, 8th Euro Meet Ferroelectricity Proc., Nijmegen,

The Netherlands, July 4–8, 1995.

34 S Sherrit, R.B Stimpson, H.D Wiederick, B.K Mukherjee,

SPIE Far East Pac Rim Symp Smart Mater Bangalore, India,

39 ANSYS/Multiphysics software, ANSYS, Inc., Canonsburg, PA,

40 Y Kagawa and T Yamabuchi, IEEE Trans Sonics Ultrasonics

SU-21: 275–283 (1974).

41 R Lerch, Proc 9th Conf Acoust., Budapest, Hungary, May

1988.

42 D.F Ostergaard and T.P Pawlak, Proc IEEE Ultrasonics

Symp., Williamsburg, VA, 1986, pp 639–642.

43 R Lerch, IEEE Trans Ultrasonics Ferroelectrics Frequency

Control 37 (2): 233–247 (1990).

44 R Simkovics, H Landes, M Kaltenbacher, and R Lerch, IEEE

Ultrasonics Symp., 1999, pp 1057–1060.

45 R Perez, E Minguella, and J.A Gorri, Proc 11th IEEE Int.

Symp Appl Ferroelectrics (ISAF), 1998, pp 247–250.

46 M Omura, H Adachi, and Y Ishibashi, Jpn J Appl Phys.

30: 2384–2387 (1991).

47 W.S Galinaitis and R.C Rogers, SPIE Smart Struct Mater.: Math Control Smart Mater., San Diego, 1997.

48 P.Ge, and M Jouaneh, Precision Eng 17: 211–221 (1995).

49 X.D Zhang and C.A Rogers, J Intelligent Mater Syst Struct.

52 A.N Soukhojak, H Wang, G.W Farrey, and Y.-M Chiang,

J Phys Chem Solids 61 (2): 301–304 (2000).

CHEMICAL INDICATING DEVICES

CHRISTOPHERO ORIAKHI Hewlett-Packard Company Corvallis, OR

INTRODUCTION

Most people remember a chemical indicator from their highschool chemistry This kind of indicator is a material thatchanges color to signify the end point of a titration or toprovide a relative indication of the acidity or alkalinity of

a chemical substance The use of indicators extends farbeyond this For example, food, cosmetic, pharmaceutical,and other chemical formulations undergo complex chemi-cal, enzymatic, and microbial interactions when they areexposed to UV light or temperature fluctuations over time.Consequently, product quality may be degraded and maylead to additional safety concerns The challenges facingthe produce industry include successful implementation

of Good Manufacturing Practices (GMP), Hazard Analysisand Critical Control Point (HACCP), Total Quality Man-agement (TQM) programs, and other regulations that de-mand compliance (1)

Trang 40

To address these issues and increase consumer

confi-dence in product quality, safety, and authenticity, many

manufacturers incorporate inexpensive monitoring

de-vices into their products during production, packaging, or

storage A large number of consumer-readable indicators

are available commercially Some examples of these types

of indicators are tags, labels, seals, and thermometers

Some give a visual color change in response to degradation

of product quality, tampering, or to detect a counterfeit

They are used extensively in the chemical, food, and

phar-maceutical industries where consumers need assurance of

product integrity, quality, and safety during

postmanufac-ture handling

Generally, chemical indicators may be defined as

stim-ulus responsive materials that can provide useful

infor-mation about changes in their environment Organic dyes,

hydrogels or “smart polymers,” shape-memory alloys,

ther-mochromic or photochromic inks, and liquid crystals are

some examples They may function by forming structurally

altered ionic or molecular complexes with species in their

environment through chemical or physical interactions

involving proton exchange, chelation, hydrogen bonding,

dipole–dipole interactions, or van der Waal forces (1)

The resulting characteristic biochemical, chemical, optical,

magnetic, thermal, or mechanical changes can be tailored

to provide the desired indication response

This article focuses on inexpensive disposable chemical

indicating devices such as pH indicators, temperature

indi-cators, time–temperature indicators (TTI), and tampering

and counterfeit indicators The temperature and TTIs are

widely used in the food and pharmaceutical products where

date coding on a package may sometimes be inadequate

CHEMICAL INDICATING DEVICES ARE SMART

Smart materials or devices are defined as materials that

produce strong visually perceptible changes in a physical

or chemical property in response to small physical or

chemical stimuli in the medium The material

proper-ties measured may include pH, concentration, composition,

solubility, humidity, pressure, temperature, light intensity,

electric and magnetic field, shape, air velocity, heat

capa-city, thermal conductivity, melting point, or reaction rates

(2–6) Chemical indicating devices can respond reversibly

or irreversibly to small changes in the physical or chemical

properties in their environment in a predictable manner

They may be regarded as smart materials because of the

range of materials properties they encompass Typical

ma-terials include shape-memory alloys, piezoelectric

mate-rials, magnetostrictive substances, electrorheological and

magnetorheological fluids, hydrogel polymers, and

photo-and thermoresponsive dyes (2–6)

CLASSIFICATION

Indicators can be classified on the basis of the response

mechanism, operating principles, or application Thus

there are chemical, biological, biochemical, electrical,

mag-netic, and mechanical indicators according to the

re-sponse mechanism Based on the intended application,

indicators can be classified as temperature indicators,

time–temperature indicators, pH indicators, counterfeitindicators, tamper indicators, freeze and thaw indicators,

or freshness indicators

GENERAL OPERATING PRINCIPLES

The response mechanism of most indicators includes one ormore of the following: physical, chemical, physicochemical,electrochemical, and biochemical Physical mechanismsare based on photophysical processes, phase transition, orother critical material properties such as melting, glasstransition, crystallization, boiling, swelling, or changes inspecific volume In most cases these transitions are driven

by changes in the interactive forces (e.g., hydrophilic–hydrophobic forces) within or around the indicator mate-rial The indicator response mechanism can also be based

on chemical, biochemical, and electrochemical reactions.Examples include acid–base, oxidation–reduction, photo-chemical, polymerization, enzymatic, and microbial reac-tions Many of these changes are irreversible, and the onset

or termination can be observed visually as a color change,color movement, or mechanical distortion (1–6)

CHOICE OF INDICATORS

Some factors governing the selection of a given indicatordevice include

should not be more expensive than the product it isprotecting

contain-ers or packages Once installed, the device must main intact and readable during the service life of thepackage

kinetics of the order of seconds to a few hours andmust be reproducible There should be no time de-lay in response to reactions involving a solid, liquid,

or gas Most applications require the response in theindicator to be irreversible to preserve the needed in-dication record

accurate, and easily activated A user-friendly cator that provides useful information when neededwill make both the product manufacturer and the con-sumer happy

to or longer than that of the product it is monitoring

rIt should be technically difficult to duplicate or

coun-terfeit the indicator’s response In this case, the cator is acting as a “smart” locking mechanism

indi-PH INDICATORS

The pH indicator is probably the oldest and simplest smartchemical indicating device known The chemistry of acid–base indicators is well documented (7) and involves proton

Ngày đăng: 13/08/2014, 05:20

TỪ KHÓA LIÊN QUAN

🧩 Sản phẩm bạn có thể quan tâm