Hook 9 3 Note: Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases.. Column Height, One Story Frame Note: Footing thickness given is

Trang 1

Exposure Category

Bay Size, ft

Column Height, ft

Stories

Column Size

Base Plate, Thickness, in

Pier Size, in x in

Footing Size, ft x ft x in

B 50 15 1 W8X24 0.75 12X12 4.0X4.0X12

Anchor Rods with Leveling Nuts

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted

Embedment, in

Cover Below Anchor, in

0.75 4X4

4 in Hook 6 6

Anchor Rods, Base Plate Shimmed or Grouted

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted

Embedment, in

Cover Below Anchor, in

0.75 4X4

3 in Hook 6 3

Exposure Category Bay Size, ft

Column Height, ft

Stories Column Size Base Plate, Thickness, in

Pier Size, in x in

Footing Size, ft x ft x in

B

50 30 1 W8X31

0.75 18X18

5.0X5.0X13

Anchor Rods with Leveling Nuts

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted Embedment, in

Cover Below Anchor, in

0.875 4X4

4 in Hook 9 9

Anchor Rods, Base Plate Shimmed or Grouted

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted Embedment, in

Cover Below Anchor, in

0.75

4X4

4 in Hook 9 3

Note: Footing thickness given is a minimum which must be

increased to match embedment plus cover in some

cases

Note: Pier size given is the minimum size required for

strength A larger pier may be required to match the

column provided

Note: The anchor rod parameters given are minimums

Table 7.7 Prescriptive Requirements for

Exposure B, 50 ft Bays, 15 ft Column

Height, One Story Frame

Note: Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases

Note: Pier size given is the minimum size required for strength A larger pier may be required to match the column provided

Note: The anchor rod parameters given are minimums

Table 7.8 Prescriptive Requirements for

Exposure B, 50 ft Bays, 30 ft Column Height, One Story Frame

Trang 2

Column Height, ft.

Stories

Column Size

Base Plate, Thickness, in

Pier Size, in x in

Footing Size, ft x ft x in

45 1 W12X65 1.0 22X22

5.5X5.5X17

Anchor Rods with Leveling Nuts

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted

Embedment, in

Cover Below Anchor, in

0.75 15X15

3 in Hook 6

3

Anchor Rods, Base Plate Shimmed or Grouted

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted

Embedment, in

Cover Below Anchor, in

0.75 15X15

3 in Hook 6

3

Column Height, ft

Stories Column Size Base Plate, Thickness, in

Pier Size, in x in

Footing Size, ft x ft x in

15 1 W8X24

0.75 12X12 4.0X4.0X12

Anchor Rods with Leveling Nuts

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted Embedment, in

Cover Below Anchor, in

0.75 4X4

3 in Hook 6 6

Anchor Rods, Base Plate Shimmed or Grouted

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted Embedment, in

Cover Below Anchor, in

0.75 4X4

3 in Hook 6

3 Note: Footing thickness given is a minimum which must be

increased to match embedment plus cover in some

cases

Note: Pier size given is the minimum size required for

strength A larger pier may be required to match the

column provided

Note: The anchor rod parameters given are minimums

Table 7.9 Prescriptive Requirements for

Exposure B, 50 ft Bays, 45 ft Column

Height, One Story Frame

Note: Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases

Note: Pier size given is the minimum size required for strength A larger pier may be required to match the column provided

Note: The anchor rod parameters given are minimums

Table 7.10 Prescriptive Requirements for

Exposure C, 30 ft Bays, 15 ft Column Height, One Story Frame

Trang 3

Exposure Category

Bay Size, ft

Column Height, ft

Stories

Column Size

Base Plate, Thickness, in

Pier Size, in x in

Footing Size, ft x ft x in

C 30 30 1 W8X31 0.75 12X12 5.0X5.0X12

Anchor Rods with Leveling Nuts

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted

Embedment, in

Cover Below Anchor, in

0.75 11X11

3 in Hook 6 6

Anchor Rods, Base Plate Shimmed or Grouted

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted

Embedment, in

Cover Below Anchor, in

0.75 4X4

4 in Hook 9 3

Exposure Category Bay Size, ft

Column Height, ft

Stories Column Size Base Plate, Thickness, in.

Pier Size, in x in

Footing Size, ft x ft x in

C 30 45 1 W12X65 1.0 12X12 6.0X6.0X15

Anchor Rods with Leveling Nuts

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted Embedment, in

Cover Below Anchor, in

0.75 15X15

3 in Hook 6 6

Anchor Rods, Base Plate Shimmed or Grouted

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted Embedment, in

Cover Below Anchor, in

0.75 15X15

4 in Hook 9 3

Note: Footing thickness given is a minimum which must be

increased to match embedment plus cover in some

cases

Note: Pier size given is the minimum size required for

strength A larger pier may be required to match the

column provided

Note: The anchor rod parameters given are minimums

Table 7.11 Prescriptive Requirements for

Exposure C, 30 ft Bays, 30 ft Column

Height, One Story Frame

Note: Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases

Note: Pier size given is the minimum size required for strength A larger pier may be required to match the column provided

Note: The anchor rod parameters given are minimums

Table 7.12 Prescriptive Requirements for

Exposure C, 30 ft Bays, 45 ft Column Height, One Story Frame

Trang 4

Column Height, ft.

Stories

Column Size

Base Plate, Thickness, in

Pier Size, in x in

Footing Size, ft x ft x in

15 1

W8X24 0.75 12X12 4.0X4.0X12

Anchor Rods with Leveling Nuts

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted

Embedment, in

Cover Below Anchor, in

0.75 4X4

3 in Hook 6 6

Anchor Rods, Base Plate Shimmed or Grouted

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted

Embedment, in

Cover Below Anchor, in

0.75 4X4

3 in Hook 6

3

Column Height, ft

Stories Column Size Base Plate, Thickness, in

Pier Size, in x in

Footing Size, ft x ft x in

30 1 W8X31 0.75 12X12

5.5X5.5X13

Anchor Rods with Leveling Nuts

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted Embedment, in

Cover Below Anchor, in

0.75 11X11

3 in Hook 9 6

Anchor Rods, Base Plate Shimmed or Grouted

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted Embedment, in

Cover Below Anchor, in

1.0

4X4

5 in Hook 9

3

Note: Footing thickness given is a minimum which must be

increased to match embedment plus cover in some

cases.

Note: Pier size given is the minimum size required for

strength A larger pier may be required to match the

column provided.

Note: The anchor rod parameters given are minimums

Table 7.13 Prescriptive Requirements for

Exposure C, 40 ft Bays, 15 ft Column

Height, One Story Frame

Note: Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases.

Note: Pier size given is the minimum size required for strength A larger pier may be required to match the

column provided

Note: The anchor rod parameters given are minimums.

Table 7.14 Prescriptive Requirements for

Exposure C, 40 ft Bays, 30 ft Column Height, One Story Frame

Trang 5

Exposure Category

Bay Size, ft

Column Height, ft

Stories

Column Size

Base Plate, Thickness, in

Pier Size, in x in

Footing Size, ft x ft x in

C 40

45 1

W12X65 1.25 12X12 6.0X6.0X18

Anchor Rods with Leveling Nuts

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted

Embedment, in

Cover Below Anchor, in

1.0 15X15

3 in Hook 9 6

Anchor Rods, Base Plate Shimmed or Grouted

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted

Embedment, in

Cover Below Anchor, in

1.0 15X15

3 in Hook 9 3

Exposure Category Bay Size, ft

Column Height, ft

Stories Column Size Base Plate, Thickness, in

Pier Size, in x in

Footing Size, ft x ft x in

C 50 15 1 W8X24 0.75 12X12 4.5X4.5X12

Anchor Rods with Leveling Nuts

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted Embedment, in

Cover Below Anchor, in

0.75 4X4

3 in Hook 6 3

Anchor Rods, Base Plate Shimmed or Grouted

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted Embedment, in

Cover Below Anchor, in

0.75 4X4

3 in Hook 6 3

Note: Footing thickness given is a minimum which must be

increased to match embedment plus cover in some

cases

Note: Pier size given is the minimum size required for

strength A larger pier may be required to match the

column provided

Note: The anchor rod parameters given are minimums

Table 7.15 Prescriptive Requirements for

Exposure C, 40 ft Bays, 45 ft Column

Height, One Story Frame

Note: Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases

Note: Pier size given is the minimum size required for strength A larger pier may be required to match the column provided

Note: The anchor rod parameters given are minimums

Table 7.16 Prescriptive Requirements for

Exposure C, 50 ft Bays, 15 ft Column Height, One Story Frame

Trang 6

Column Height, ft.

Stories

Column Size

Base Plate, Thickness, in

Pier Size, in x in

Footing Size, ft x ft x in

30 1 W8X31 0.875 12X12 5.5X5.5X17

Anchor Rods with Leveling Nuts

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted

Embedment, in

Cover Below Anchor, in

0.75 11X11

4 in Hook 6 6

Anchor Rods, Base Plate Shimmed or Grouted

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted

Embedment, in

Cover Below Anchor, in

1.0 4X4

5 in Hook 9

3

Column Height, ft

Stories Column Size Base Plate, Thickness, in

Pier Size, in x in

Footing Size, ft x ft x in

45 1 W12X65 1.25 12X12 6.5X6.5X16

Anchor Rods with Leveling Nuts

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted Embedment, in

Cover Below Anchor, in

1.0 15X15

4 in Hook 6 9

Anchor Rods, Base Plate Shimmed or Grouted

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted Embedment, in

Cover Below Anchor, in

1.0 15X15

4 in Hook 9 3

Note: Footing thickness given is a minimum which must be

increased to match embedment plus cover in some

cases

Note: Pier size given is the minimum size required for

strength A larger pier may be required to match the

column provided

Note: The anchor rod parameters given are minimums

Table 7.17 Prescriptive Requirements for

Exposure C, 50 ft Bays, 30 ft Column

Height, One Story Frame

Note: Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases

Note: Pier size given is the minimum size required for strength A larger pier may be required to match the column provided

Note: The anchor rod parameters given are minimums

Table 7.18 Prescriptive Requirements for

Exposure C, 50 ft Bays, 45 ft Column Height, One Story Frame

Trang 7

Exposure Category

Bay Size, ft

Column Height, ft

Stories

Column Size

Base Plate, Thickness, in

Pier Size, in x in

Footing Size, ft x ft x in

B 30 20 2 W8X31 0.75 12X12 5.0X5.0X18

Anchor Rods with Leveling Nuts

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted

Embedment, in

Cover Below Anchor, in

0.875 4X4

4 in Hook 9 9

Anchor Rods, Base Plate Shimmed or Grouted

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted

Embedment, in

Cover Below Anchor, in

0.75 4X4

3 in Hook 6 3

Exposure Category Bay Size, ft

Column Height, ft

Stories Column Size Base Plate, Thickness, in

Pier Size, in x in

Footing Size, ft x ft x in

B 40 30 2 W8X31 0.75 12X12 5.0X5.0X18

Anchor Rods with Leveling Nuts

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted Embedment, in

Cover Below Anchor, in

1.0 4X4

5 in Hook 9 9

Anchor Rods, Base Plate Shimmed or Grouted

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted Embedment, in

Cover Below Anchor, in

0.875 4X4

4 in Hook 6 3

Note: Footing thickness given is a minimum which must be

increased to match embedment plus cover in some

cases

Note: Pier size given is the minimum size required for

strength A larger pier may be required to match the

column provided

Note: The anchor rod parameters given are minimums

Table 7.19 Prescriptive Requirements for

Exposure B, 30 ft Bays, 20 ft Column

Height, Two Story Frame

Note: Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases

Note: Pier size given is the minimum size required for strength A larger pier may be required to match the column provided

Note: The anchor rod parameters given are minimums

Table 7.20 Prescriptive Requirements for

Exposure B, 40 ft Bays, 30 ft Column Height, Two Story Frame

Trang 8

Column Height, ft.

Stories

Column Size

Base Plate, Thickness, in

Pier Size, in x in

Footing Size, ft x ft x in

30 2 W8X31 0.75 12X12 5.0X5.0X18

Anchor Rods with Leveling Nuts

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted

Embedment, in

Cover Below Anchor, in

1.0 4X4

5 in Hook 9 9

Anchor Rods, Base Plate Shimmed or Grouted

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted

Embedment, in

Cover Below Anchor, in

0.875 4X4

4 in Hook 9 3

Column Height, ft

Stories Column Size Base Plate, Thickness, in

Pier Size, in x in

Footing Size, ft x ft x in

30 2 W8X31 0.75 12X12 5.0X5.0X18

Anchor Rods with Leveling Nuts

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted Embedment, in

Cover Below Anchor, in

1.0 4X4

5 in Hook 9 9

Anchor Rods, Base Plate Shimmed or Grouted

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted Embedment, in

Cover Below Anchor, in

0.875 4X4

5 in Hook 9 3

Note: Footing thickness given is a minimum which must be

increased to match embedment plus cover in some

cases

Note: Pier size given is the minimum size required for

strength A larger pier may be required to match the

column provided

Note: The anchor rod parameters given are minimums

Table 7.21 Prescriptive Requirements for

Exposure B, 50 ft Bays, 30 ft Column

Height, Two Story Frame

Note: Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases

Note: Pier size given is the minimum size required for strength A larger pier may be required to match the column provided

Note: The anchor rod parameters given are minimums

Table 7.22 Prescriptive Requirements for

Exposure C, 30 ft Bays, 30 ft Column Height, Two Story Frame

Trang 9

Exposure Category

Bay Size, ft

Column Height, ft

Stories

Column Size

Base Plate, Thickness, in

Pier Size, in x in

Footing Size, ft x ft x in

C 40 30

2

W8X31 1.0 12X12 5.0X5.0X18

Anchor Rods with Leveling Nuts

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted

Embedment, in

Cover Below Anchor, in

0.75 11X11

3 in Hook 6 6

Anchor Rods, Base Plate Shimmed or Grouted

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted

Embedment, in

Cover Below Anchor, in

1.0 4X4

4 in Hook 9 3

Exposure Category Bay Size, ft

Column Height, ft

Stories Column Size Base Plate, Thickness, in

Pier Size, in x in

Footing Size, ft x ft x in

C 50 30 2 W8X31 1.0 12X12 6.0X6.0X14

Anchor Rods with Leveling Nuts

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted Embedment, in

Cover Below Anchor, in

0.875 11X11

4 in Hook 9 9

Anchor Rods, Base Plate Shimmed or Grouted

Anchor Rod, Diameter, in

Anchor Pattern, in x in

Hooked or Nutted Embedment, in

Cover Below Anchor, in

0.875 11X11

4 in Hook 9

3 Note: Footing thickness given is a minimum which must be

increased to match embedment plus cover in some

cases

Note: Pier size given is the minimum size required for

strength A larger pier may be required to match the

column provided

Note: The anchor rod parameters given are minimums

Table 7.23 Prescriptive Requirements for

Exposure C, 40 ft Bays, 30 ft Column

Height, Two Story Frame

Note: Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases

Note: Pier size given is the minimum size required for strength A larger pier may be required to match the column provided

Note: The anchor rod parameters given are minimums

Table 7.24 Prescriptive Requirements for