Hook 9 3 Note: Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases.. Column Height, One Story Frame Note: Footing thickness given is
Trang 1Exposure Category
Bay Size, ft
Column Height, ft
Stories
Column Size
Base Plate, Thickness, in
Pier Size, in x in
Footing Size, ft x ft x in
B 50 15 1 W8X24 0.75 12X12 4.0X4.0X12
Anchor Rods with Leveling Nuts
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted
Embedment, in
Cover Below Anchor, in
0.75 4X4
4 in Hook 6 6
Anchor Rods, Base Plate Shimmed or Grouted
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted
Embedment, in
Cover Below Anchor, in
0.75 4X4
3 in Hook 6 3
Exposure Category Bay Size, ft
Column Height, ft
Stories Column Size Base Plate, Thickness, in
Pier Size, in x in
Footing Size, ft x ft x in
B
50 30 1 W8X31
0.75 18X18
5.0X5.0X13
Anchor Rods with Leveling Nuts
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted Embedment, in
Cover Below Anchor, in
0.875 4X4
4 in Hook 9 9
Anchor Rods, Base Plate Shimmed or Grouted
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted Embedment, in
Cover Below Anchor, in
0.75
4X4
4 in Hook 9 3
Note: Footing thickness given is a minimum which must be
increased to match embedment plus cover in some
cases
Note: Pier size given is the minimum size required for
strength A larger pier may be required to match the
column provided
Note: The anchor rod parameters given are minimums
Table 7.7 Prescriptive Requirements for
Exposure B, 50 ft Bays, 15 ft Column
Height, One Story Frame
Note: Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases
Note: Pier size given is the minimum size required for strength A larger pier may be required to match the column provided
Note: The anchor rod parameters given are minimums
Table 7.8 Prescriptive Requirements for
Exposure B, 50 ft Bays, 30 ft Column Height, One Story Frame
Trang 2Column Height, ft.
Stories
Column Size
Base Plate, Thickness, in
Pier Size, in x in
Footing Size, ft x ft x in
45 1 W12X65 1.0 22X22
5.5X5.5X17
Anchor Rods with Leveling Nuts
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted
Embedment, in
Cover Below Anchor, in
0.75 15X15
3 in Hook 6
3
Anchor Rods, Base Plate Shimmed or Grouted
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted
Embedment, in
Cover Below Anchor, in
0.75 15X15
3 in Hook 6
3
Column Height, ft
Stories Column Size Base Plate, Thickness, in
Pier Size, in x in
Footing Size, ft x ft x in
15 1 W8X24
0.75 12X12 4.0X4.0X12
Anchor Rods with Leveling Nuts
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted Embedment, in
Cover Below Anchor, in
0.75 4X4
3 in Hook 6 6
Anchor Rods, Base Plate Shimmed or Grouted
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted Embedment, in
Cover Below Anchor, in
0.75 4X4
3 in Hook 6
3 Note: Footing thickness given is a minimum which must be
increased to match embedment plus cover in some
cases
Note: Pier size given is the minimum size required for
strength A larger pier may be required to match the
column provided
Note: The anchor rod parameters given are minimums
Table 7.9 Prescriptive Requirements for
Exposure B, 50 ft Bays, 45 ft Column
Height, One Story Frame
Note: Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases
Note: Pier size given is the minimum size required for strength A larger pier may be required to match the column provided
Note: The anchor rod parameters given are minimums
Table 7.10 Prescriptive Requirements for
Exposure C, 30 ft Bays, 15 ft Column Height, One Story Frame
Trang 3Exposure Category
Bay Size, ft
Column Height, ft
Stories
Column Size
Base Plate, Thickness, in
Pier Size, in x in
Footing Size, ft x ft x in
C 30 30 1 W8X31 0.75 12X12 5.0X5.0X12
Anchor Rods with Leveling Nuts
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted
Embedment, in
Cover Below Anchor, in
0.75 11X11
3 in Hook 6 6
Anchor Rods, Base Plate Shimmed or Grouted
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted
Embedment, in
Cover Below Anchor, in
0.75 4X4
4 in Hook 9 3
Exposure Category Bay Size, ft
Column Height, ft
Stories Column Size Base Plate, Thickness, in.
Pier Size, in x in
Footing Size, ft x ft x in
C 30 45 1 W12X65 1.0 12X12 6.0X6.0X15
Anchor Rods with Leveling Nuts
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted Embedment, in
Cover Below Anchor, in
0.75 15X15
3 in Hook 6 6
Anchor Rods, Base Plate Shimmed or Grouted
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted Embedment, in
Cover Below Anchor, in
0.75 15X15
4 in Hook 9 3
Note: Footing thickness given is a minimum which must be
increased to match embedment plus cover in some
cases
Note: Pier size given is the minimum size required for
strength A larger pier may be required to match the
column provided
Note: The anchor rod parameters given are minimums
Table 7.11 Prescriptive Requirements for
Exposure C, 30 ft Bays, 30 ft Column
Height, One Story Frame
Note: Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases
Note: Pier size given is the minimum size required for strength A larger pier may be required to match the column provided
Note: The anchor rod parameters given are minimums
Table 7.12 Prescriptive Requirements for
Exposure C, 30 ft Bays, 45 ft Column Height, One Story Frame
Trang 4Column Height, ft.
Stories
Column Size
Base Plate, Thickness, in
Pier Size, in x in
Footing Size, ft x ft x in
15 1
W8X24 0.75 12X12 4.0X4.0X12
Anchor Rods with Leveling Nuts
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted
Embedment, in
Cover Below Anchor, in
0.75 4X4
3 in Hook 6 6
Anchor Rods, Base Plate Shimmed or Grouted
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted
Embedment, in
Cover Below Anchor, in
0.75 4X4
3 in Hook 6
3
Column Height, ft
Stories Column Size Base Plate, Thickness, in
Pier Size, in x in
Footing Size, ft x ft x in
30 1 W8X31 0.75 12X12
5.5X5.5X13
Anchor Rods with Leveling Nuts
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted Embedment, in
Cover Below Anchor, in
0.75 11X11
3 in Hook 9 6
Anchor Rods, Base Plate Shimmed or Grouted
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted Embedment, in
Cover Below Anchor, in
1.0
4X4
5 in Hook 9
3
Note: Footing thickness given is a minimum which must be
increased to match embedment plus cover in some
cases.
Note: Pier size given is the minimum size required for
strength A larger pier may be required to match the
column provided.
Note: The anchor rod parameters given are minimums
Table 7.13 Prescriptive Requirements for
Exposure C, 40 ft Bays, 15 ft Column
Height, One Story Frame
Note: Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases.
Note: Pier size given is the minimum size required for strength A larger pier may be required to match the
column provided
Note: The anchor rod parameters given are minimums.
Table 7.14 Prescriptive Requirements for
Exposure C, 40 ft Bays, 30 ft Column Height, One Story Frame
Trang 5Exposure Category
Bay Size, ft
Column Height, ft
Stories
Column Size
Base Plate, Thickness, in
Pier Size, in x in
Footing Size, ft x ft x in
C 40
45 1
W12X65 1.25 12X12 6.0X6.0X18
Anchor Rods with Leveling Nuts
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted
Embedment, in
Cover Below Anchor, in
1.0 15X15
3 in Hook 9 6
Anchor Rods, Base Plate Shimmed or Grouted
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted
Embedment, in
Cover Below Anchor, in
1.0 15X15
3 in Hook 9 3
Exposure Category Bay Size, ft
Column Height, ft
Stories Column Size Base Plate, Thickness, in
Pier Size, in x in
Footing Size, ft x ft x in
C 50 15 1 W8X24 0.75 12X12 4.5X4.5X12
Anchor Rods with Leveling Nuts
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted Embedment, in
Cover Below Anchor, in
0.75 4X4
3 in Hook 6 3
Anchor Rods, Base Plate Shimmed or Grouted
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted Embedment, in
Cover Below Anchor, in
0.75 4X4
3 in Hook 6 3
Note: Footing thickness given is a minimum which must be
increased to match embedment plus cover in some
cases
Note: Pier size given is the minimum size required for
strength A larger pier may be required to match the
column provided
Note: The anchor rod parameters given are minimums
Table 7.15 Prescriptive Requirements for
Exposure C, 40 ft Bays, 45 ft Column
Height, One Story Frame
Note: Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases
Note: Pier size given is the minimum size required for strength A larger pier may be required to match the column provided
Note: The anchor rod parameters given are minimums
Table 7.16 Prescriptive Requirements for
Exposure C, 50 ft Bays, 15 ft Column Height, One Story Frame
Trang 6Column Height, ft.
Stories
Column Size
Base Plate, Thickness, in
Pier Size, in x in
Footing Size, ft x ft x in
30 1 W8X31 0.875 12X12 5.5X5.5X17
Anchor Rods with Leveling Nuts
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted
Embedment, in
Cover Below Anchor, in
0.75 11X11
4 in Hook 6 6
Anchor Rods, Base Plate Shimmed or Grouted
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted
Embedment, in
Cover Below Anchor, in
1.0 4X4
5 in Hook 9
3
Column Height, ft
Stories Column Size Base Plate, Thickness, in
Pier Size, in x in
Footing Size, ft x ft x in
45 1 W12X65 1.25 12X12 6.5X6.5X16
Anchor Rods with Leveling Nuts
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted Embedment, in
Cover Below Anchor, in
1.0 15X15
4 in Hook 6 9
Anchor Rods, Base Plate Shimmed or Grouted
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted Embedment, in
Cover Below Anchor, in
1.0 15X15
4 in Hook 9 3
Note: Footing thickness given is a minimum which must be
increased to match embedment plus cover in some
cases
Note: Pier size given is the minimum size required for
strength A larger pier may be required to match the
column provided
Note: The anchor rod parameters given are minimums
Table 7.17 Prescriptive Requirements for
Exposure C, 50 ft Bays, 30 ft Column
Height, One Story Frame
Note: Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases
Note: Pier size given is the minimum size required for strength A larger pier may be required to match the column provided
Note: The anchor rod parameters given are minimums
Table 7.18 Prescriptive Requirements for
Exposure C, 50 ft Bays, 45 ft Column Height, One Story Frame
Trang 7Exposure Category
Bay Size, ft
Column Height, ft
Stories
Column Size
Base Plate, Thickness, in
Pier Size, in x in
Footing Size, ft x ft x in
B 30 20 2 W8X31 0.75 12X12 5.0X5.0X18
Anchor Rods with Leveling Nuts
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted
Embedment, in
Cover Below Anchor, in
0.875 4X4
4 in Hook 9 9
Anchor Rods, Base Plate Shimmed or Grouted
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted
Embedment, in
Cover Below Anchor, in
0.75 4X4
3 in Hook 6 3
Exposure Category Bay Size, ft
Column Height, ft
Stories Column Size Base Plate, Thickness, in
Pier Size, in x in
Footing Size, ft x ft x in
B 40 30 2 W8X31 0.75 12X12 5.0X5.0X18
Anchor Rods with Leveling Nuts
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted Embedment, in
Cover Below Anchor, in
1.0 4X4
5 in Hook 9 9
Anchor Rods, Base Plate Shimmed or Grouted
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted Embedment, in
Cover Below Anchor, in
0.875 4X4
4 in Hook 6 3
Note: Footing thickness given is a minimum which must be
increased to match embedment plus cover in some
cases
Note: Pier size given is the minimum size required for
strength A larger pier may be required to match the
column provided
Note: The anchor rod parameters given are minimums
Table 7.19 Prescriptive Requirements for
Exposure B, 30 ft Bays, 20 ft Column
Height, Two Story Frame
Note: Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases
Note: Pier size given is the minimum size required for strength A larger pier may be required to match the column provided
Note: The anchor rod parameters given are minimums
Table 7.20 Prescriptive Requirements for
Exposure B, 40 ft Bays, 30 ft Column Height, Two Story Frame
Trang 8Column Height, ft.
Stories
Column Size
Base Plate, Thickness, in
Pier Size, in x in
Footing Size, ft x ft x in
30 2 W8X31 0.75 12X12 5.0X5.0X18
Anchor Rods with Leveling Nuts
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted
Embedment, in
Cover Below Anchor, in
1.0 4X4
5 in Hook 9 9
Anchor Rods, Base Plate Shimmed or Grouted
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted
Embedment, in
Cover Below Anchor, in
0.875 4X4
4 in Hook 9 3
Column Height, ft
Stories Column Size Base Plate, Thickness, in
Pier Size, in x in
Footing Size, ft x ft x in
30 2 W8X31 0.75 12X12 5.0X5.0X18
Anchor Rods with Leveling Nuts
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted Embedment, in
Cover Below Anchor, in
1.0 4X4
5 in Hook 9 9
Anchor Rods, Base Plate Shimmed or Grouted
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted Embedment, in
Cover Below Anchor, in
0.875 4X4
5 in Hook 9 3
Note: Footing thickness given is a minimum which must be
increased to match embedment plus cover in some
cases
Note: Pier size given is the minimum size required for
strength A larger pier may be required to match the
column provided
Note: The anchor rod parameters given are minimums
Table 7.21 Prescriptive Requirements for
Exposure B, 50 ft Bays, 30 ft Column
Height, Two Story Frame
Note: Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases
Note: Pier size given is the minimum size required for strength A larger pier may be required to match the column provided
Note: The anchor rod parameters given are minimums
Table 7.22 Prescriptive Requirements for
Exposure C, 30 ft Bays, 30 ft Column Height, Two Story Frame
Trang 9Exposure Category
Bay Size, ft
Column Height, ft
Stories
Column Size
Base Plate, Thickness, in
Pier Size, in x in
Footing Size, ft x ft x in
C 40 30
2
W8X31 1.0 12X12 5.0X5.0X18
Anchor Rods with Leveling Nuts
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted
Embedment, in
Cover Below Anchor, in
0.75 11X11
3 in Hook 6 6
Anchor Rods, Base Plate Shimmed or Grouted
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted
Embedment, in
Cover Below Anchor, in
1.0 4X4
4 in Hook 9 3
Exposure Category Bay Size, ft
Column Height, ft
Stories Column Size Base Plate, Thickness, in
Pier Size, in x in
Footing Size, ft x ft x in
C 50 30 2 W8X31 1.0 12X12 6.0X6.0X14
Anchor Rods with Leveling Nuts
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted Embedment, in
Cover Below Anchor, in
0.875 11X11
4 in Hook 9 9
Anchor Rods, Base Plate Shimmed or Grouted
Anchor Rod, Diameter, in
Anchor Pattern, in x in
Hooked or Nutted Embedment, in
Cover Below Anchor, in
0.875 11X11
4 in Hook 9
3 Note: Footing thickness given is a minimum which must be
increased to match embedment plus cover in some
cases
Note: Pier size given is the minimum size required for
strength A larger pier may be required to match the
column provided
Note: The anchor rod parameters given are minimums
Table 7.23 Prescriptive Requirements for
Exposure C, 40 ft Bays, 30 ft Column
Height, Two Story Frame
Note: Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases
Note: Pier size given is the minimum size required for strength A larger pier may be required to match the column provided
Note: The anchor rod parameters given are minimums
Table 7.24 Prescriptive Requirements for
Exposure C, 50 ft Bays, 30 ft Column Height, Two Story Frame