New Plasma Generation Technology Patented Flat Plate™ Plasma Technology Generates a unique symmetrical plasma 8L/min argon as compared to 15L/min Maintenance-free and requiring no coo
Trang 1TRUNG TÂM DỊCH VỤ PHÂN TÍCH THÍ NGHIỆM
Trang 3¢ Metallurgical Process Control
e Wear Metals in Oils
¢ Environmental (Waters, Soils etc)
¢ Foods
¢ Agricultural
* Others
Trang 4"Bohr Model of Bee a8 PAGE
Excited
States
>» Many transitions are possible AE = hv = he/A
> Emitted light depends on energy difference of
_two states
h = Planck’s constant, v = fee
Trang 6> related to amount of radiation emitted or
absorbed at analyte wavelength
» depends on concentration
Quantitation in Atomic Emission & CASE
Concentration proportional to intensity
emitted at the analyte wavelength
Emission
Trang 7i aj8 CASE
‘What is a Plasma?
>A plasma is a stream of highly ionized gas
containing an equal number of electrons
and positive ions
> A plasma i is electrically conduetive re eee an
ñÿậ CASE
Inductively Coupled Plasma
(ICP)
ICP is an emission source ideally suited to
rapid, multielement analysis
Trang 8ICP Characteristics - ae CASE :
> Low Background @ %&° G9 Ge AA! bate greued cam The
» Low Detection Limits for 70 Elements (Typically
low ppb)
» Inherently multielement
>» High sample throughput
» Wide Calibration Range
> Major, minor and trace in one solution
a8 CASE
Plasma Background
>» The plasma emits a continuum of radiation
> The intensity increases two orders of
magnitude between 200 and 400 nm
>» Wavelengths below 190 nm require
vacuum or purged optical system
Trang 9Figure 2-3 Zones of the ICP IR - Induction Re-
gion, PHZ - Preheating Zone, IRZ - Initial Radia- ion Zone, NAZ - Normal Analytical Zone
Trang 10
How is a Plasma Formed?
Argon Plasma Excitation Energy
In general, transitions observed in an ICP are
limited to those of less energy than the
ionization energy of the gas
Ar —— Art +e 15.4 eV
Trang 11
1A
Optical
Trang 12PHZ IRZ NAZ Tail Plume
ie r Gas Position PHZ (Pre Heating Zone) O Tail Plume
IRZ (Initial Radiation Zone) Decay to Ground State
al Analytical Zone)
ntly tonic Emission SELF ABSORPTION of lic
zone for excited states
Shear gas design
Extends working range
No maintenance necessary
No consumables to replace
_ Shear gas of air-not expensive AT :
a gemminates carryover anc
Trang 14ICP Spectroscopy Basics 7 é{8 CASE
ICP is an argon plasma maintained ~ OES is spectrometer which
Intensity of light is proportional to amount of element
Trang 15
Sample Peristaltic Pump
Major Components of Optima 5X00, 7X00, 8X00
Trang 16Figure $19 —inetaiting the cycionic epray chamber,
th Biome — Tá, Nếu ise Flow nh In, (Gem Tips) _
Cyclonic Spray Chamber with + =Gonoeniric Neb
Trang 17New Plasma Generation Technology
Patented Flat Plate™ Plasma Technology
Generates a unique symmetrical plasma
( 8L/min argon as compared to 15L/min ) Maintenance-free and requiring no cooling
Trang 18
ICP-OES OpticalSystem — _ ẩj$ CASE -
a CN J
Z z2 ot
» Sequential or Scanning ICP-OES(a fing, ng f8 - a ES ae a Se _ = wo “
n
* select any wavelength and focus it ona single detector
* design with ne- moving grating resulting
® Measure one element at a time by moving ;
Device (SCD) Detector — the detector use :
for Simultaneous \cp- cee gio be a
Đ
<= Cross-Disperser Grating Dispersion ns
Register for the
Trang 20Optima True ˆ”ˆ Echalle | Dual sco 163-782nm Radiai j Yes
Optima True Echelle Dual SCD 163-782 nm Dual View Yes
8300 DV | Simultaneous Polychromator
Introduction
>» Models
* Optima 8000 —Avio 200 (Sequential), Optima 8300 — Avio 500 (Simultaneous)
« The Optima 7000 DV is replaced by
ñj$ CASE
the Optima 8000
* The Optima 7300 DVis replaced by the Optima 8300
>» Changes
New Flat Plate™ RF Generator Desi
Syngistix software ign, new PlasmaCam"™ ,ICP WinLab32 software or
Qqverg
Trang 22
Features Designed for Customer Na
Patented Hat “Induction Plate” Design
Generates a unique symmetrical plasma
Optimal performance at reduced argon flow while
preserving stability and precision
Reduced cost of ownership (half the argon
consumption)
Long-life aluminum plates do not require cooling
Ease of Manufacture and Service
Same robust matrix-tolerant plasma can be generated at pool
` argon as compared to 15L/mincÊ» ag
Trang 23
oe ij§ CASE
Who Should Consider Avio 200?
Typically less than 100 samples a day » Lower speed of analysis
1 to 5 elements per sample Best analytical performance Small- to medium-size labs
Low to moderate sample loads
> Challenging analytical problems
> Demands sample throughput
> Ultimate analytical performance
> Performance and productivity
» Simultaneous measurements: Speed
» Better results than the competition
> Superior optical system
> Superior resolution —
> Superior software
“Tend to be large companies with moderate to heavy sample loads and want the
best product, service and support
Trang 25
than Th, Phubhg Ngoc |
PHUONG PHAP QUANG PHO
PHAT XA PLASMA (ICP- OES)
=1 Giới Điệu thành phần dinh dưỡng
s2, ae trinh phan tich mau :
3 Phan tich Na, Ca, Fe trén lcP -OES_
4 Công thức tính giá trị dinh tường ( Daily
Trang 26
eo: f afi CASE
I KHAI NIEM VE NUTRITION
- Thực phẩm đóng một vai tro căn bản trong việc
cung cấp nguồn năng lượng sống cho cơ thể
- Thực phẩm được cấu tạo bởi các chất bổ dưỡng
(Nutrients), bao gồm những thành phần hóa học,để
nuôi sống cơ thể
- Dinh Dưỡng : hấp thu những chất bổ dưỡng
trong thức ăn để nuôi dưỡng thân thể
I KHAI NIEM VE NUTRITION
- Thyc pham được phân thành các nhóm tùy vào
thành phan dinh dưỡng nhiêu nhất
Trang 28
Vai trò của Natri (Na- Sodium) iy CASE
- Khoáng chất có vai trò thiết yếu đối với cơ thể con
- Nếu lượng Natri trong cơ thể quá cao (với những người
ăn mặn) sẽ gây ra nhiều tác hại cho sức khỏe như tim đập nhanh, mắt cân bằng điện giải, mỏi cơ, co giật, gây hại cho gan và thận, thậm chí tử vong
Vai trò của Canxi (Ca - Calcium)_ 8 CASE
Giúp cơ thê hình thành hệ xương và răng vững chắc
Đảm bảo chức năng thần kinh và sự đông máu bình thường
Ca trong máu giảm -> cơ thể lấy Ca từ xương dé tham gia
các quá trình chuyên hóa >3 đau nhức các xương đặc biệt các xương dài ở trẻ đang tuổi phát triển; -> tình trạng mat ngủ, tính tình nóng nảy
Thiếu Ca lâu dài trong khẩu phần > bệnh cao huyết áp và
ung thư ruột
Lượng Ca ăn vào dư thừa -> Ca được bài tiết ra khỏi cơ thể Dùng thuốc Ga liều cao, kéo dài > soi than, canxi máu cao,
thận làm việc kém hiệu quả ; giam hap thu cac chat khoang
cần thiết khác (ví dụ: sat, kém, magié, phosphor, iod, dong)
Trang 30
1-3 7mg 19-30 18mg
4-6 10mg 31-50 1amg 7-9 10mg 51-65 10mg
10-12 10mg >75 10mg
13-15 10mg 16-18 12mg
Nhu cầu Natri của con người
Tổ chức Y tế Thế giới (WHO) khuyến nghị ít hơn 2 gram natri
- Hiệp hội Tim mạch Mỹ đưa ra khuyến nghị thận trọng hơn là
1,5 gram natri mỗi ngày, đặc biệt đối với những người có nguy
cơ mắc bệnh tim :
ayo CASE
Trang 32
Đồng Than hóa Để nguội -
mau, can : 25°C, 3-5h Xử lý lại mẫu —”{ lại > tro trang :
(Ca A=317.933nm , Na A=589,592 nm, Fe A=238,204 nm)
- Cài đặt thông số kỹ thuật theo máy
Trang 33Ca, Na : Radial (xuyên tâm)->!⁄F9 = +
Fe : Axial (doc truc)> "aq Te me -
"ST pump: HỆ Sample Flow Rate (mL/min) :1.5
Trang 34
Ai os 38 CASE
PHAN TICH MAU TREN ICP-OES
Bước 2: Xây dựng đường chuẩn (Define standards)
Lập đường chuẩn phù hợp với mẫu đo:
PHAN TÍCH MAU TREN ICP-OES aie CASE
'Bước 3 : phân tích mẫu
Trang 36
_IV.TÍNH TOÁN KÉT QUÁ
s Tính toán hàm lượng các nguyên tố cần phân tích :
trong mẫu thực tế ban đầu
: : HL: hàm lượng nguyên tô
có trong mẫu phân tích -_G: lượng can
2.Trích dẫn từ nguồn của Healthvn
3 Trích dẫn từ nguồn của WHO
4 Trích dẫn từ nguồn Viện Dinh Dưỡng Quốc Gia
12
Trang 38
348 CASE Các phương pháp phân tích Pb, Cd
* Quang phé hap thu nguyen tử Quang phổ phát xa nguyên tử Phổ khối lượng nguyên tử Phương pháp vôn-ampe hoà tan
Trang 42=1 sa at Sch SOE EE EEE TAL
1mg/L (Pha loãng từ chuẩn 1000mg/L)
* Cai đặt các thông số tối ưu cho máy ICP-OES
- Tiến hành đo chuẩn và mẫu