untitled Li ce ns ed c op y B ra df or d U ni ve rs ity , U ni ve rs ity o f B ra df or d, V er si on c or re ct a s of 2 1/ 03 /2 01 2 14 3 1, ( c) T he B rit is h S ta nd ar ds In st itu tio n 20 12[.]
Trang 1BRITISH STANDARD BS EN
61300-2-22:2007
Fibre optic interconnecting devices and passive components — Basic test and measurement procedures —
Part 2-22: Tests — Change of temperature
The European Standard EN 61300-2-22:2007 has the status of a British Standard
ICS 33.180.20
12&23<,1*:,7+287%6,3(50,66,21(;&(37$63(50,77('%<&23<5,*+7/$:
Trang 2This British Standard was
published under the authority
of the Standards Policy and
Strategy Committee
on 31 August 2007
© BSI 2007
ISBN 978 0 580 54207 7
National foreword
This British Standard is the UK implementation of EN 61300-2-22:2007 It is identical to IEC 61300-2-22:2007 It supersedes BS EN 61300-2-22:1997 which
is withdrawn
The UK participation in its preparation was entrusted by Technical Committee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnecting devices and passive components
A list of organizations represented on this committee can be obtained on request to its secretary
This publication does not purport to include all the necessary provisions of a contract Users are responsible for its correct application
Compliance with a British Standard cannot confer immunity from legal obligations.
Amendments issued since publication
Trang 3EUROPEAN STANDARD EN 61300-2-22
NORME EUROPÉENNE
EUROPÄISCHE NORM June 2007
CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members
Ref No EN 61300-2-22:2007 E
English version
Fibre optic interconnecting devices and passive components -
Basic test and measurement procedures -
Part 2-22: Tests - Change of temperature
(IEC 61300-2-22:2007)
Dispositifs d'interconnexion
et composants passifs à fibres optiques -
Méthodes fondamentales d'essais
et de mesures -
Partie 2-22: Essais -
Variations de température
(CEI 61300-2-22:2007)
Lichtwellenleiter - Verbindungselemente und passive Bauteile - Grundlegende Prüf- und Messverfahren - Teil 2-22: Prüfungen -
Temperaturwechsel (IEC 61300-2-22:2007)
This European Standard was approved by CENELEC on 2007-04-01 CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member
This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom
Trang 4Foreword
The text of document 86B/2440/FDIS, future edition 2 of IEC 61300-2-22, prepared by SC 86B, Fibre optic interconnecting devices and passive components, of IEC TC 86, Fibre optics, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61300-2-22 on 2007-04-01
This European Standard supersedes EN 61300-2-22:1997
EN 61300-2-22:1997 specifies tests Na and Nb of EN 60068-2-14, however this EN 61300-2-22:2007 describes the test method of Nb and specifies “optional cycle” for some other performance categories The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
– latest date by which the national standards conflicting
Annexes ZA and ZB have been added by CENELEC
Endorsement notice
The text of the International Standard IEC 61300-2-22:2007 was approved by CENELEC as a European Standard without any modification
EN 61300-2-22:2007
Trang 5CONTENTS
1 Scope 4
2 Normative references 4
3 General description 4
4 Apparatus 4
5 Procedure 4
5.1 Preconditioning 5
5.2 Initial measurements 5
5.3 Testing 5
5.4 Recovery 6
5.5 Final measurements 6
6 Severity 6
7 Details to be specified 7
Bibliography 8
Figure 1 – Temperature profile 5
Figure 2 – Optional temperature profile 6
Table 1 – Severities 6
EN 61300-2-22:2007 – 3 – Annex ZA (normative) Special national conditions 9
17 nnex ZBBAnnex ZBibliography 17
Annex ZB (normative) Normative references to international publications with their corresponding European publications 9
Trang 6FIBRE OPTIC INTERCONNECTING DEVICES AND
PASSIVE COMPONENTS – BASIC TEST AND MEASUREMENT PROCEDURES – Part 2-22: Tests – Change of temperature
1 Scope
This part of IEC 61300 describes a procedure to determine the suitability of a fibre optic device to withstand the effects of a change of temperature or a succession of changes of temperature
The following referenced documents are indispensable for the application of this document For dated references, only the edition cited applies For undated references, the latest edition
of the referenced document (including any amendments) applies
IEC 60068-2-14, Basic environmental testing procedures – Part 2-14: Tests – Test N: Change
of temperature
This procedure is conducted in accordance with IEC 60068-2-14, test Nb The device under
test (DUT) is first subjected to one extreme of temperature for a given period of time It is then subjected to the other extreme of temperature for an equal period of time
4 Apparatus
The apparatus consists of suitable environmental chambers in accordance with IEC
60068-2-14, test Nb
The rate of change of temperature shall be: (1 ± 0,2) °C/min
5 Procedure
These procedures are in accordance with IEC 60068-2-14, test Nb
Unless otherwise stated in the relevant specification:
– include 1,5 m of cable in the climatic chamber for each port monitored during the test; – if optical measurements are requested during the test by the relevant specification, these measurements shall be performed (at a minimum) at the end of each dwell at each temperature extreme;
– allow dependence on wavelength scan time for components that require wavelength scanning
Trang 75.1 Preconditioning
Unless otherwise stated in the relevant specification, maintain the DUT under standard atmospheric conditions for 2 h minimum Clean the mechanical and optical alignment parts of the DUT according to the manufacturer's instructions
5.2 Initial measurements
Take initial examinations and measurements as required by the relevant specification
5.3 Testing
5.3.1 Place the specimen in the chamber in its normal operating position and make
connections to the monitoring equipment
5.3.2 Unless otherwise specified, the temperature profile in Figure 1 shall be applied Start
at standard atmospheric conditions and ramp down to the low temperature T at 1 °C/min A
Maintain the low temperature during t1 for a minimum of 60 min Ramp up to the high temperature T B at 1 °C/min Maintain the temperature during t1, then ramp down to the low temperature and repeat this profile for the required number of cycles
t1
t1
TB
TA
A
First cycle Second cycle
Time t
IEC 263/07
A = start of first cycle
Figure 1 – Temperature profile
NOTE It is permissible to increase the dwell time at each extreme to allow sufficient time to perform a complete set of measurements
5.3.3 Optional cycle: for some performance categories, it may be necessary to ramp to the
high temperature first and include a dwell at room temperature between ramps to the extreme temperatures In this case, the profile in Figure 2 shall be applied
Start at standard atmospheric conditions and ramp up to the high temperature T at 1 °C/min
Then maintain the high temperature during t1 for a minimum of 60 min Ramp down to standard atmospheric conditions at 1 °C/min Maintain standard atmospheric conditions for a minimum of 60 min Ramp down to the low temperature T L at 1 °C/min Maintain that
temperature during t1 for a minimum of 60 min Ramp up to standard atmospheric conditions
at 1 °C/min and dwell for a minimum of 60 min The subsequent cycles will have the same pattern
EN 61300-2-22:2007
– 5 –
Trang 8T
TL
A
First cycle Second cycle
Time t
t1
IEC 264/07
A = start of first cycle
Figure 2 – Optional temperature profile
5.4 Recovery
Allow the specimen to remain under standard atmospheric conditions for a period of at least
2 h
5.5 Final measurements
Record final measurements as required by the relevant specification Unless otherwise specified in the relevant specification, clean the DUT according to the manufacturer's instructions prior to recording final measurements
6 Severity
Each of the following severities consist of a combination of a low temperature with the corresponding high temperature and the corresponding number of cycles One of them shall
be specified in the relevant specification:
Table 1 – Severities
Category Low temperature
°C
High temperature
°C
Number of cycles
C –10 +60 5
U –25 +70 12
E –40 +85 12
O –40 +75 21
A –40 +65 20
G –40 +65 20
S –30 +60 20
Trang 97 Details to be specified
The following details, as applicable, shall be specified in the relevant specification:
– severity;
– initial examinations and measurements and performance requirements;
– examinations and measurements during test and performance requirements;
– final examinations and measurements and performance requirements;
– deviations from test procedure;
– additional pass/fail criteria;
– relevant monitoring procedure
EN 61300-2-22:2007
– 7 –
Trang 10Bibliography
IEC 61300-1, Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 1: General and guidance
IEC 61300-2-47, Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-47: Tests – Thermal shocks
_
NOTE Harmonized as EN 61300-1:2003 (not modified)
NOTE Harmonized as EN 61300-2-47:2007 (not modified)
Trang 11Annex ZA
(normative)
Special national conditions
Special national condition: National characteristic or practice that cannot be changed even over a long
period, e.g climatic conditions, electrical earthing conditions
NOTE If it affects harmonization, it forms part of the European Standard / Harmonization Document
For the countries in which the relevant special national conditions apply these provisions are normative, for other countries they are informative
Clause Special national condition
6, Table 1 Finland
In the categories E, O, A and G, the minimum temperature shall be –45 °C
EN 61300-2-22:2007
– 9 –
Annex ZB
(normative)
Normative references to international publications with their corresponding European publications
The following referenced documents are indispensable for the application of this document For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies
Publication Year Title EN/HD Year
IEC 60068-2-14 -1) Environmental testing -
Part 2: Tests - Test N: Change of temperature
EN 60068-2-14 19992)
Trang 12
BSI
389 Chiswick High Road
London
W4 4AL
BSI — British Standards Institution
BSI is the independent national body responsible for preparing British Standards It presents the UK view on standards in Europe and at the international level It is incorporated by Royal Charter
Revisions
British Standards are updated by amendment or revision Users of British Standards should make sure that they possess the latest amendments or editions
It is the constant aim of BSI to improve the quality of our products and services
We would be grateful if anyone finding an inaccuracy or ambiguity while using this British Standard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover
Tel: +44 (0)20 8996 9000 Fax: +44 (0)20 8996 7400
BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards
Buying standards
Orders for all BSI, international and foreign standards publications should be addressed to Customer Services Tel: +44 (0)20 8996 9001
Fax: +44 (0)20 8996 7001 Email: orders@bsi-global.com Standards are also available from the BSI website at http://www.bsi-global.com
In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise requested
Information on standards
BSI provides a wide range of information on national, European and international standards through its Library and its Technical Help to Exporters Service Various BSI electronic information services are also available which give details on all its products and services Contact the Information Centre
Tel: +44 (0)20 8996 7111 Fax: +44 (0)20 8996 7048 Email: info@bsi-global.com Subscribing members of BSI are kept up to date with standards developments and receive substantial discounts on the purchase price of standards For details
of these and other benefits contact Membership Administration
Tel: +44 (0)20 8996 7002 Fax: +44 (0)20 8996 7001
Email: membership@bsi-global.com
Information regarding online access to British Standards via British Standards Online can be found at http://www.bsi-global.com/bsonline
Further information about BSI is available on the BSI website at http://www.bsi-global.com
Copyright
Copyright subsists in all BSI publications BSI also holds the copyright, in the
UK, of the publications of the international standardization bodies Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means – electronic, photocopying, recording or otherwise – without prior written permission from BSI
This does not preclude the free use, in the course of implementing the standard,
of necessary details such as symbols, and size, type or grade designations If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained
Details and advice can be obtained from the Copyright & Licensing Manager Tel: +44 (0)20 8996 7070 Fax: +44 (0)20 8996 7553