BSI Standards PublicationFibre optic interconnecting devices and passive components — Basic test and measurement procedures Part 2-52: Tests — Bending test for cords... The UK participa

Trang 1

BSI Standards Publication

Fibre optic interconnecting devices and passive

components — Basic test and measurement procedures

Part 2-52: Tests — Bending test for cords

Trang 2

National foreword

This British Standard is the UK implementation of EN 61300-2-52:2013 It is identical to IEC 61300-2-52:2013

BSI, as a member of CEN, is obliged to publish EN 61300-2-52 as a British Standard However, attention is drawn to the fact that during the development of this European Standard, the UK committee voted against its approval as a European Standard

The committee noted a possible inconsistency between clause 3, which states that optical measurements should be made before and after the test, and clause 5.4, c) which states that optical measurements are also made during the test The committee is also of the opinion that the mention of fibre, cable and resilient members being fixed together in clause 4.3 may not be appropriate for all fibre optic connectors

The UK participation in its preparation was entrusted by Technical Committee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnecting devices and passive components

A list of organizations represented on this subcommittee can be obtained

on request to its secretary

This publication does not purport to include all the necessary provisions of

a contract Users are responsible for its correct application

© The British Standards Institution 2014

Published by BSI Standards Limited 2014

ISBN 978 0 580 70942 5

ICS 33.180.20

Compliance with a British Standard cannot confer immunity from legal obligations.

This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 March 2014

Amendments /corrigenda issued since publication Amd No Date Text affected

Trang 3

NORME EUROPÉENNE

CENELEC

European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members

Ref No EN 61300-2-52:2013 E

ICS 33.180.20

English version

Fibre optic interconnecting devices and passive components -

Basic test and measurement procedures -

Part 2-52: Tests - Bending test for cords

(IEC 61300-2-52:2013)

Dispositifs d’interconnexion et

composants passifs à fibres optiques -

Procédures fondamentales d’essais et de

mesures -

Partie 2-52: Essais -

Essai de courbure pour les cordons

(CEI 61300-2-52:2013)

Lichtwellenleiter - Verbindungselemente und passive Bauteile -

Grundlegende Prüf- und Messverfahren - Teil 2-52: Prüfungen -

Biegeprüfung für konfektionierte Kabel (IEC 61300-2-52:2013)

This European Standard was approved by CENELEC on 2013-03-28 CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration

Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member

This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified

to the CEN-CENELEC Management Centre has the same status as the official versions

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom

Trang 4

EN 61300-2-52:2013 - 2 -

Foreword

The text of document 86B/3547/FDIS, future edition 1 of IEC 61300-2-52, prepared by SC 86B, "Fibre optic interconnecting devices and passive components", of IEC TC 86, "Fibre optics" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 61300-2-52:2013

The following dates are fixed:

• latest date by which the document has

to be implemented at national level by

publication of an identical national

standard or by endorsement

(dop) 2013-12-28

• latest date by which the national

standards conflicting with the

document have to be withdrawn

(dow) 2016-03-28

Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent rights

Endorsement notice

The text of the International Standard IEC 61300-2-52:2013 was approved by CENELEC as a European Standard without any modification

In the official version, for Bibliography, the following notes have to be added for the standards indicated:

IEC 60794-1-2 NOTE Harmonized as EN 60794-1-2

IEC 61300-3-28 NOTE Harmonized as EN 61300-3-28

Trang 5

- 3 - EN 61300-2-52:2013

Annex ZA

(normative)

Normative references to international publications with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies

NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies

IEC 61300-1 - Fibre optic interconnecting devices and

passive components - Basic test and measurement procedures -

Part 1: General and guidance

EN 61300-1 -

IEC 61300-3-1 - Fibre optic interconnecting devices and

passive components - Basic test and measurement procedures -

Part 3-1: Examinations and measurements - Visual examination

EN 61300-3-1 -

IEC 61300-3-3 - Fibre optic interconnecting devices and

passive components - Basic test and measurement procedures -

Part 3-3: Examinations and measurements - Active monitoring of changes in attenuation and return loss

EN 61300-3-3 -

IEC 61300-3-4 - Fibre optic interconnecting devices and

passive components - Basic test and measurement procedures -

Part 3-4: Examinations and measurements - Attenuation

EN 61300-3-4 -

Trang 6

– 2 – 61300-2-52 © IEC:2013

CONTENTS

1 Scope 5

2 Normative references 5

3 General description 5

4 Apparatus 5

4.1 General 5

4.2 Cord 5

4.3 Specimen 6

4.4 Optical measurements 6

5 Procedure 6

5.1 General 6

5.2 Preconditioning 6

5.3 Initial examinations and measurements 6

5.4 Procedure 6

5.5 Final examinations and measurements 7

6 Severity 7

7 Details to be specified 8

Bibliography 9

Figure 1 – Specimen fixed onto mandrel 7

Figure 2 – Cable wrapped around mandrel 7

Figure 3 – Required number of mandrel rotations applied 7

Table 1 – Severity 8

Trang 7

61300-2-52 © IEC:2013 – 5 –

FIBRE OPTIC INTERCONNECTING DEVICES

AND PASSIVE COMPONENTS – BASIC TEST AND MEASUREMENT PROCEDURES – Part 2-52: Tests – Bending test for cords

1 Scope

This part of the IEC 61300 series describes a procedure to determine the suitability of a cord to withstand bending around a mandrel of the sort to be applied during normal use This test is only applied to single fibre cables and multiple fibre circular cables It is not applicable to ribbon cables

2 Normative references

The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies

IEC 61300-1, Fibre optic interconnecting devices and passive components – Basic test and

measurement procedures – Part 1: General and guidance

IEC 61300-3-1, Fibre optic interconnecting devices and passive components – Basic test and

measurement procedures – Part 3-1: Examinations and measurements – Visual examination

IEC 61300-3-3, Fibre optic interconnecting devices and passive components – Basic test and

measurement procedures – Part 3-3: Examinations and measurements – Active monitoring of changes in attenuation and return loss

IEC 61300-3-4, Fibre optic interconnecting devices and passive components – Basic test and

measurement procedures – Part 3-4: Examinations and measurements – Attenuation

3 General description

The purpose of this test is to determine the capability of the cord when repeatedly bent Optical measurements are made before and after the test to screen for evidence of damage to the fibre/cable

4 Apparatus

4.1 General

A single mandrel apparatus shall enable the sample to be wrapped tangentially in a close helix around a single test mandrel

4.2 Cord

A cord is a fibre optic cable terminated with any passive fibre optic connector on both ends, regardless of its expected use Examples include equipment cords, work area cords or patchcords

Trang 8

– 6 – 61300-2-52 © IEC:2013

4.3 Specimen

The specimen shall be a cord The connectors shall be terminated according to the manufacturer's instructions so that the fibre, cable and resilient members are fixed together

4.4 Optical measurements

Unless otherwise specified, measuring equipment specified in IEC 61300-3-4 shall be connected to the specimen for monitoring optical performance during the test

5 Procedure

5.1 General

Sufficient tension shall be applied to ensure that the sample contours the mandrel The sample shall then be unwrapped

A cycle consists of one wrapping and one unwrapping

The diameter of the test mandrel, the number of turns of the mandrel and the number of cycles shall be shown in the relevant specification

5.2 Preconditioning

Precondition the specimen and all equipment for 2 h under standard test conditions as defined

in IEC 61300-1, unless otherwise specified in the relevant specification

5.3 Initial examinations and measurements

Complete the initial examinations and measurements

5.4 Procedure

a) Connect the specimen to the optical measurement equipment according to IEC 61300-3-3 b) The specimen shall be initially positioned as shown in Figure 1 The two straight sections shall be perpendicular to the mandrel and spacing between the two straight sections shall

be such that the diameter of the loop is greater than the cable's minimum bend diameter c) Start the optical power measurements

d) The specimen shall be wrapped around the mandrel at a uniform tension such that there are no gaps between the cable and the mandrel during the bending cycles (see Figure 2) The required number of turns around the mandrel shall be applied Each revolution of cable

on the mandrel shall be close to the adjacent revolutions or cable wraps (see Figure 3) e) The specimen shall be kept in this position for at least 1 min

f) The specimen shall be unwrapped and kept in this position for at least 1 min

g) The required number of cycles shall be applied by repeating steps d) to f) in a timely manner at a rate no greater than 1 wrap per minute

h) Stop optical power measurements

Trang 9

61300-2-52 © IEC:2013 – 7 –

Specimen

Figure 1 – Specimen fixed onto mandrel

IEC 483/13

Figure 2 – Cable wrapped around mandrel

IEC 484/13

Figure 3 – Required number of mandrel rotations applied 5.5 Final examinations and measurements

Unwrap the cable from the mandrel and make the final measurements, as defined by the relevant specification, to ensure that there is no permanent damage to the specimen The results of the final measurement shall be within the limit established in the relevant specification

Visually check (IEC 61300-3-1) that the cable and fibre optic device are not damaged

6 Severity

Severity consists of the combination of the number of turns per helix, number of cycles, mandrel diameter and cord length The severity shall be specified in the relevant specification

or taken from Table 1 below:

Trang 10

– 8 – 61300-2-52 © IEC:2013

Table 1 – Severity

15 × cable diameter for cable diameter >4 mm

Length of specimen sufficient to carry out the test

Distance between connectors and mandrel

7 Details to be specified

The following details, as applicable, shall be specified in the relevant specification:

a) cable and connector type;

b) wavelength of the attenuation measurement;

c) initial examinations and measurements and performance requirements;

d) examinations and measurements during test and performance requirements;

e) final examinations and measurements and performance requirements;

f) deviations from test procedure;

g) additional pass/fail criteria;

h) diameter of the test mandrel, the number of turns of the mandrel, and the number of cycles

Trang 11

61300-2-52 © IEC:2013 – 9 –

Bibliography

IEC 60794-1-2, Optical fibre cables – Part 1-2: Generic specification – Basic optical cable test

procedures

IEC 61300-3-28, Fibre optic interconnecting devices and passive components – Basic test and

measurement procedures – Part 3-28:Examinations and measurements – Transient loss

_

Trang 14

BSI is the national body responsible for preparing British Standards and other

standards-related publications, information and services.

BSI is incorporated by Royal Charter British Standards and other standardization products are published by BSI Standards Limited.

British Standards Institution (BSI)

BSI Group Headquarters

389 Chiswick High Road London W4 4AL UK

About us

We bring together business, industry, government, consumers, innovators

and others to shape their combined experience and expertise into standards

-based solutions.

The knowledge embodied in our standards has been carefully assembled in

a dependable format and refined through our open consultation process

Organizations of all sizes and across all sectors choose standards to help

them achieve their goals.

Information on standards

We can provide you with the knowledge that your organization needs

to succeed Find out more about British Standards by visiting our website at

bsigroup.com/standards or contacting our Customer Services team or

Knowledge Centre.

Buying standards

You can buy and download PDF versions of BSI publications, including British

and adopted European and international standards, through our website at

bsigroup.com/shop, where hard copies can also be purchased

If you need international and foreign standards from other Standards Development

Organizations, hard copies can be ordered from our Customer Services team.

Subscriptions

Our range of subscription services are designed to make using standards

easier for you For further information on our subscription products go to

bsigroup.com/subscriptions.

With British Standards Online (BSOL) you’ll have instant access to over 55,000

British and adopted European and international standards from your desktop

It’s available 24/7 and is refreshed daily so you’ll always be up to date

You can keep in touch with standards developments and receive substantial

discounts on the purchase price of standards, both in single copy and subscription

format, by becoming a BSI Subscribing Member

PLUS is an updating service exclusive to BSI Subscribing Members You will

automatically receive the latest hard copy of your standards when they’re

revised or replaced

To find out more about becoming a BSI Subscribing Member and the benefits

of membership, please visit bsigroup.com/shop.

With a Multi-User Network Licence (MUNL) you are able to host standards

publications on your intranet Licences can cover as few or as many users as you

wish With updates supplied as soon as they’re available, you can be sure your

documentation is current For further information, email bsmusales@bsigroup.com.

Revisions

Our British Standards and other publications are updated by amendment or revision

We continually improve the quality of our products and services to benefit your business If you find an inaccuracy or ambiguity within a British Standard or other BSI publication please inform the Knowledge Centre.

Copyright

All the data, software and documentation set out in all British Standards and other BSI publications are the property of and copyrighted by BSI, or some person

or entity that owns copyright in the information used (such as the international standardization bodies) and has formally licensed such information to BSI for commercial publication and use Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system

or transmitted in any form or by any means – electronic, photocopying, recording

or otherwise – without prior written permission from BSI Details and advice can

be obtained from the Copyright & Licensing Department.

Useful Contacts:

Customer Services Tel: +44 845 086 9001 Email (orders): orders@bsigroup.com Email (enquiries): cservices@bsigroup.com Subscriptions

Tel: +44 845 086 9001 Email: subscriptions@bsigroup.com Knowledge Centre

Tel: +44 20 8996 7004 Email: knowledgecentre@bsigroup.com Copyright & Licensing

Tel: +44 20 8996 7070 Email: copyright@bsigroup.com

Ngày đăng: 15/04/2023, 10:16

TÀI LIỆU CÙNG NGƯỜI DÙNG

  • Đang cập nhật ...

TÀI LIỆU LIÊN QUAN