Tiêu đề Optical Fibre Cables Part 5-20: Family Specification — Outdoor Microduct Fibre Units, Microducts And Protected Microducts For Installation By Blowing
Trường học British Standards Institution
Chuyên ngành Standards Publication
Thể loại standards publication
Năm xuất bản 2014
Thành phố Brussels
Định dạng
Số trang 36
Dung lượng 1,38 MB

Các công cụ chuyển đổi và chỉnh sửa cho tài liệu này

Cấu trúc

  • 4.1 Construction (11)
    • 4.1.1 General (0)
    • 4.1.2 Microduct fibre units (0)
    • 4.1.3 Microducts (0)
    • 4.1.4 Protected microducts (0)
    • 4.1.5 Microduct fittings (0)
    • 4.1.6 Microduct hardware (0)
  • 4.2 Optical fibres (13)
  • 4.3 Installation performance tests (13)
    • 4.3.1 Installation conditions (0)
    • 4.3.2 Tests applicable (0)
    • 4.3.3 Mechanical and environmental tests (0)
  • 5.1 Tests applicable (14)
  • 5.2 Family requirements and test conditions for microduct fibre unit tests (15)
  • 5.3 Tensile performance (15)
  • 5.4 Crush (15)
  • 5.5 Repeated bending (16)
  • 5.6 Torsion (16)
  • 5.7 Kink (16)
  • 5.8 Bend (16)
  • 5.9 Temperature cycling (16)
  • 5.10 Ageing (17)
  • 5.11 Water immersion (17)
  • 5.12 Buffer removal (17)
  • 6.1 Tests applicable (17)
  • 6.2 Tensile performance (18)
  • 6.3 Crush (18)
  • 6.4 Impact (19)
  • 6.5 Repeated bending (19)
  • 6.6 Torsion (19)
  • 6.7 Kink (19)
  • 6.8 Bend (19)
  • 6.9 Microduct route verification test (20)
  • 6.10 Microduct pressure withstand (20)
  • 6.11 Ageing (20)
  • 7.1 Tests applicable (20)
  • 7.2 Tensile performance (21)
  • 7.3 Crush (21)
  • 7.4 Impact (22)
  • 7.5 Repeated bending (22)
  • 7.6 Kink (22)
  • 7.7 Bend (22)
  • 7.8 Microduct route verification test (22)
  • 7.9 Microduct pressure withstand (23)
  • 7.10 Ageing (23)
  • D.1 Attenuation of cabled fibre (31)
  • D.2 Fibre bandwidth requirements (32)
  • E.1 Object (33)
  • E.2 General (33)
  • E.3 Sample (33)
  • E.4 Test equipment (33)
  • E.5 Procedure (33)
  • E.6 Requirements (33)
  • E.7 Details to be recorded (34)

Nội dung

BSI Standards PublicationOptical fibre cables Part 5-20: Family specification — Outdoor microduct fibre units, microducts and protected microducts for installation by blowing... NORME EU

Construction

Microduct hardware

Fittings must be suitable for the construction of microducts, and their mechanical and environmental performance should be tested in conjunction with ducting sections to guarantee compatibility and functionality It is essential for the customer and supplier to agree on the specific physical and material characteristics of the fittings used.

Microduct fittings must withstand the pressure differences required for the installation of microduct fibre units through blowing They should successfully pass the pressurization test outlined in section 6.10 when connected to microducts Additionally, these fittings must facilitate a seamless transition of microduct fibre units between consecutive sections or from microducts to hardware, ensuring that they are designed and installed to prevent any jamming at splice, branch, or other connection points under maximum installation pressures.

Microduct sections can be welded or secured along the same longitudinal axis without mechanical fittings, provided that these junctions adhere to the same mechanical and dimensional standards as those created with fittings.

Translucent or transparent materials may be used to support the identification of populated microducts and for troubleshooting installation related issues

Microduct hardware encompasses the housings and closures essential for terminating microduct fibre units, which include splicing or connectorization These fibre units are typically compatible with traditional outdoor fibre optic cable hardware, eliminating the need for specific microduct hardware requirements In certain scenarios, utilizing hardware that aligns with microducts can facilitate the creation of a sealed microduct cabling system, such as when empty microducts are pre-installed to accommodate future fibre unit placement.

Optical fibres

There shall be no fibre splice in a delivered length, unless otherwise agreed by the customer and supplier

It shall be possible to identify each individual fibre throughout the length of the microduct fibre unit

The transmission performance shall be in accordance with Annex D.

Installation performance tests

Mechanical and environmental tests

Tests that are applicable for installation performance are given in Table 1

Table 1 – Tests applicable for installation performance

Characteristics Family requirements Test methods Remarks

General requirements Agreement between customer and supplier

Route verification inner clearance test Agreement between customer and supplier IEC 60794-1-21 Method E23

Installation test Agreement between customer and supplier; typically a minimum distance and time of installation over a specified route is required

Agreement between customer and supplier; typically, duct type and size, route terrain, installation device, maximum air pressure and ambient air conditions should be specified or noted with the results

This article outlines the performance specifications for microduct fibre units, microducts, and protected microducts, taking into account the anticipated operating conditions and mechanical loads experienced during installation.

Tests applicable

Tests that are applicable for mechanical and environmental performance are given in Table 2

Table 2 – Tests applicable for mechanical and environmental performance of microduct fibre unit

Characteristics Family requirements Test methods Remarks

Buffer removal 5.12 As agreed with customer

The water penetration test is not a requirement for microduct cabling systems, as suitable means for water blocking are already in place For smaller units, such as those with an outer diameter of less than 2 mm and a tensile rating under 100 N, it may be more beneficial to forgo certain tests in favor of conducting an installation test.

When using these cables, it is essential to modify the testing procedures to prevent end effects during clamping Careful handling is crucial to avoid unacceptable damage such as rips, tears, splits, delamination, or cracks in the microduct fibre unit It is important to note that damage occurring at the clamping interface does not indicate a failure.

Family requirements and test conditions for microduct fibre unit tests

Tests shall be selected from the following by the product specification.

Tensile performance

Under short-term tensile load the fibre strain shall not exceed 60 % of the fibre proof strain Other criteria may be agreed between the customer and supplier b) Test conditions (loads ≥ 100 N)

The method follows IEC 60794-1-21 Method E1, with a specified duration The length under tension should be no less than 10 meters; however, shorter lengths may be utilized by mutual agreement between the customer and supplier, considering measurement accuracy and end effects.

Fibre length: Finished microduct fibre unit length

Tensile load: Equivalent to weight of 1 km of fibre unit

The diameter of test pulleys should be determined through agreement between the customer and supplier, ensuring it meets or exceeds the minimum loaded bending diameter specified for the microduct fibre unit, with a recommended minimum value of 60 mm.

Under visual examination without magnification there shall be no damage to the microduct fibre unit and there shall be no change in attenuation after the test c) Test conditions (loads < 100 N)

Length under tension: Approx 250 mm

Fibre length: Finished microduct fibre unit length

Tensile load: Equivalent to weight of 1 km of fibre unit

Under visual examination without magnification there shall be no damage to the microduct fibre unit.

Crush

After the load is removed, the attenuation should remain unchanged from its state prior to loading A visual inspection must reveal no damage to the microduct fibre unit, and any imprint left by the plate on the unit is not classified as mechanical damage.

Repeated bending

Under visual examination without magnification there shall be no damage to the microduct fibre unit elements b) Test conditions

Bending diameter: 40 × d or 60 mm whichever is greater

Load: Adequate to assure uniform contact with the mandrel

Torsion

Under visual examination without magnification there shall be no damage to the microduct fibre unit elements

There shall be no change in attenuation after the test b) Test conditions

Method Generally in accordance with IEC 60794-1-21 Method E7

Load: Adequate to assure test sample is straight at start of test.

Kink

Under visual examination, there shall be no damage to the microduct fibre unit b) Test conditions

Minimum diameter: 40 × d or 60 mm whichever is greater

Bend

There shall be no change in attenuation after the test when measured at room temperature b) Test conditions

Diameter of mandrel: 40 × d or 60 mm whichever is greater

Temperature cycling

For T A1 to T B1 there shall be no change in attenuation as defined in IEC 60794-1-1

For T A1 to T A2 and T B1 to T B2 , the change in attenuation coefficient shall be:

– ≤ 0,15 dB/km for single-mode fibre and shall be reversible to measurement uncertainty when measured in the 1 550 nm region;

– ≤ 0,3 dB/km for multimode fibre and shall be reversible to measurement uncertainty when measured in the 1 300 nm region b) Test conditions

Sample length under test: Finished microduct fibre unit length of at least 1 000 m

High temperature, T B2 : +60 °C to +70 °C, depending on customer requirements High temperature, T B1 : +30 °C to +60 °C depending on customer requirements Low temperature, T A1 : –15 °C

Low temperature, T A2 : T A1 to –30 °C or –40 °C depending on customer requirements Note (temperatures): Other temperature values corresponding to specific climate conditions can be agreed between supplier and customer Number of cycles: 2

Ageing

a) Family requirements: as per IEC 60794-1-22, Method F9 b) Test conditions:

Water immersion

Attenuation coefficient change at room temperature:

– ≤ 0,05 dB/km at 1 550 nm for single-mode fibre;

– ≤ 0,2 dB/km at 850 nm and 1 300 nm for multimode fibre

The attenuation shall be monitored throughout the test at least once every 24 h b) Test conditions

Water: Distilled, demineralized or de-ionized water which has a PH of between 5,0 and 8,0

Buffer removal

Buffer materials must be designed for easy removal, ensuring that primary coated fibers or fiber ribbons remain undamaged and free from any sheathing or buffer materials after testing.

The method for buffer removal shall be defined by the supplier

Tests applicable

Tests will be chosen from Table 3 based on the applicable product specifications If the microduct is intended solely for use within a protected microduct, certain tests may not apply.

Table 3 – Tests applicable for mechanical and environmental performance of microduct

Characteristics Family requirements Test methods Remarks

Microduct route verification test 6.9 IEC 60794-1-21

When adapting tests for microducts, it is crucial to modify clamping techniques to prevent end effects Potential damage such as rips, tears, splits, or cracks in the microduct must be avoided, although damage at the clamping interface is not considered a failure.

Tensile performance

Under visual examination, without magnification, there shall be no damage after the test and shall pass the inner clearance test (Annex E) b) Test conditions

Method: Generally to IEC 60794-1-21, Method E1

(note: use of IEC 60811-501 is under consideration) Microduct length under tension: >1 m

Crush

The microduct must exhibit no visible damage upon visual inspection without magnification Following the recovery period, it should successfully pass the inner clearance test as outlined in Annex E, with no signs of splitting or permanent damage It is important to note that the imprint of the plate does not qualify as mechanical damage.

Impact

Visual inspection of the microducts must show no damage, and they should successfully pass the inner clearance test as outlined in Annex E, with no signs of splitting or permanent damage It is important to note that any imprint from the striking surface on the microduct does not qualify as mechanical damage.

Number of impacts: One in 3 different places spread not less than 500 mm apart

Repeated bending

The microducts must show no visible damage during a standard examination without magnification Additionally, they should successfully pass the inner clearance test as outlined in Annex E, ensuring there is no splitting or permanent damage.

Load: Adequate to assure uniform contact with the mandrel

Torsion

Kink

Under visual examination, without magnification, there shall be no damage to the microducts after the test and shall pass the inner clearance test (Annex E)

The microduct shall attain the required minimum diameter without kinking b) Test conditions

Bend

The microducts must exhibit no visible damage to both the outer and inner diameters upon visual inspection without magnification Additionally, they must successfully pass the inner clearance test as outlined in Annex E.

Microduct route verification test

Objects of the required size, including any blowing tip if used in practice, can be passed through the microduct b) Test conditions

Microduct pressure withstand

Under visual examination, without magnification, there shall be no damage to the microducts b) Test conditions

All microducts shall resist an air pressure of at least 2,5 × the installation pressure at a temperature of 20 °C for a period of 0,5 h

All microducts shall resist a proof test pressure of at least 1,3 × the installation pressure at a temperature of 40 °C for a period of 24 h.

Ageing

After the aging period, the customer and supplier should agree on the tests to be conducted, which may encompass dimensions, inner clearance tests, shrinkage assessments, alterations to surface finish, and pressurization or installation tests of the microduct fiber unit.

Aging condition: Under consideration (+60 °C for 3 months;

Tests applicable

Tests shall be selected from the following Table 4, in accordance with the relevant product specification

Table 4 – Tests applicable for mechanical and environmental performance of protected microduct

Characteristics Family requirements Test methods Remarks

Microduct route verification test 7.9 IEC 60794-1-21 Method

Microduct pressure withstand 7.10 IEC 60794-1-22 Method

Tensile performance

Under visual examination, without magnification, there shall be no damage after the test and shall pass the inner clearance test (Annex E) b) Test conditions

Method: Generally to IEC 60794-1-21 Method E1 (note: use of

IEC 60811-501 is under consideration) Microduct length under tension: >1 m

Tensile load on microduct: 1 W or 2 700 N, whichever is the smaller

Crush

The microduct must exhibit no visible damage during a visual inspection without magnification Following the recovery period, it should successfully pass the inner clearance test as outlined in Annex E, with no signs of splitting or permanent damage Additionally, any imprint from the plate is not classified as mechanical damage.

Load: 1 kN (duct); 2 kN (buried)

Impact

Visual inspection of the microducts must show no damage, and they should successfully pass the inner clearance test as outlined in Annex E, with no signs of splitting or permanent damage Additionally, any imprint from the striking surface on the microduct is not classified as mechanical damage.

Number of impacts: One in 3 different places spread not less than 500 mm apart

Repeated bending

Visual inspection of the microducts must show no damage, and they must successfully pass the inner clearance test as outlined in Annex E, ensuring there is no splitting or permanent damage.

Load: Adequate to assure uniform contact with the mandrel

Kink

Under visual examination, without magnification, there shall be no damage to the microducts after the test and shall pass the inner clearance test (Annex E)

The microduct shall attain the required minimum diameter without kinking b) Test conditions

Bend

The microducts must exhibit no visible damage to both the outer and inner diameters upon visual inspection without magnification Additionally, they must successfully pass the inner clearance test as outlined in Annex E.

Microduct route verification test

Objects of the required size, including any blowing tip if used in practice, can be passed through the microduct b) Test conditions

Microduct pressure withstand

Under visual examination, without magnification, there shall be no damage to the microducts b) Test conditions

All microducts shall resist an air pressure of at least 2,5 × the installation pressure at a temperature of 20 °C for a period of 0,5 h

All microducts shall resist a proof test pressure of at least 1,3 × the installation pressure at a temperature of 40 °C for a period of 24 h.

Ageing

After the aging period, the customer and supplier should agree on the tests to be conducted, which may encompass dimensions, inner clearance tests, shrinkage assessments, alterations to surface finish, and pressurization or installation tests of the microduct fiber unit.

Aging condition: Under consideration (+60 °C for 3 months; 7 days at 70 °C;

Examples of microduct fibre units, microducts, and protected microducts

Figure A.1 and Figure A.2 give useful examples of microduct fibre units, microducts, and protected microducts

Figure A.1 – Protected microducts, tight package

Product descriptions (blank detail specification and minimum requirements)

Tables B.1, B.2, B.3 give templates for the description of microducts fibre unit, microducts and protected microducts

Table B.1 – Microduct fibre unit description

(3) Available from: (4) Generic specifications: IEC 60794-1-1 and IEC 60794-1-2

Sectional specification: IEC 60794-5 Family specification: IEC 60794-5-20

Optical fibre type (s) Additional remarks

Minimum bending radius for no-load bending mm or n × d

(3) Available from: (4) Generic specifications: IEC 60794-1-1 and IEC 60794-1-2

Sectional specification: IEC 60794-5 Family specification: IEC 60794-5-20

Maximum outer diameter (OD) mm

Minimum inner diameter (ID) mm

Note: one or the other of these may be selected

Minimum bending radius for no-load bending mm or n × OD

Maximum operating air pressure Pa

(3) Available from: (4) Generic specifications: IEC 60794-1-1 and IEC 60794-1-2

Sectional specification: IEC 60794-5 Family specification: IEC 60794-5-20

(7) Protected microduct construction Additional remarks

– Range of microduct count (e.g 1 or more)

– Maximum outer diameter (OD) mm

Minimum inner diameter (ID) mm

Note: one or the other of these may be selected

– Minimum bending radius for no-load bending mm or n × OD

– Minimum bending radius for rated-load bending mm or n × OD

– Maximum outer diameter (OD’) mm

– Minimum bending radius for no-load bending mm or n × OD’

– Minimum bending radius for rated-load bending mm or n × OD’

Maximum operating air pressure, microduct bar/Pa

– Operation ºC a In general, protected microducts contain microducts b Not applicable to microducts installed loosely into pre-installed ducts

Tables C.1, C.2, C.3 give templates for the product construction of microducts fibre unit, microducts and protected microducts

Table C.1 – Typical microduct fibre unit construction

Characteristics Family requirements Test methods Remarks

Filling compound (if used) According to detail specification Either IEC 60794-1-21

The article discusses the specifications outlined in Method E14 and standards IEC 60811-601, IEC 60811-602, and IEC 60811-604 It emphasizes the use of dry blocking compounds and ribbons, which must adhere to detailed specifications Additionally, the strength member is also subject to these specifications and requires visual inspection to ensure compliance.

Filler According to detail specification Visual inspection

Ripcord According to detail specification Visual inspection

Material According to detail specification Outside diameter According to detail specification IEC 60811-203 Minimum thickness According to detail specification IEC 60811-202 Optional protection

3:2001 Moisture barrier According to detail specification Microduct fibre unit marking

Configuration, dimensions According to detail specification Visual inspection Microduct fibre unit length According to detail specification Under consideration

Characteristics Family requirements Test methods Remarks

Material According to detail specification

Outer diameter According to detail specification IEC 60811-203 Minimum inner diameter According to detail specification IEC 60811-203 This method may be adapted to measure inner diameter

Minimum wall thickness According to detail specification IEC 60811-202 Microduct liner:

Type According to detail specification Under consideration

Material According to detail specification Under consideration Marking

Configuration, dimensions According to detail specification Visual inspection

Characteristics Family requirements Test methods Remarks

The microduct specifications include the outer diameter (OD) and inner diameter (ID) sizes as detailed The count of microducts for each size is currently under consideration, in accordance with the specifications Additionally, the type and material of the microduct liner are specified, with the material still under review.

Lay-up According to detail specification Visual inspection

Strength member (optional) According to detail specification Visual inspection Sheath

– Outer diameter [OD’] Acc DS IEC 60811-203

– Minimum thickness Acc DS IEC 60811-202

According to detail specification According to detail specification 7.6.5 of IEC 60794-3:2001

Configuration, dimensions According to detail specification Visual inspection Abrasion resistance According to detail specification IEC 60794-1-21

Method E2B Steel needle diameter d = 1,0 mm load: 4 N, 30 cycles

Protected microduct length Under consideration

Attenuation of cabled fibre

The attenuation coefficient of cabled fibre must be lower than the maximum values specified in Table D.1 for multimode fibres and Table D.2 for single-mode fibres, according to the relevant wavelengths These specifications are applicable to premises cabling outlined in the IEC 60794 series and ISO/IEC 11801 Additionally, maximum values for other specifications within the IEC 60794 series can be found in Table D.3.

The fibre category shall be agreed between customer and supplier

Table D.1 – Multimode maximum cable attenuation coefficient (dB/km)

Fibre category Attenuation coefficient at 850 nm Attenuation coefficient at 1 300 nm Performance code

IEC 60793-2-10, A1a.3 3,5 1,5 OM1, OM2, OM3, OM4

Table D.2 – Single-mode maximum cable attenuation coefficient (dB/km) – Premises cabling applications

Fibre category Wavelengths nm Maximum attenuation coefficient Performance code

Table D.3 – Single-mode maximum cable attenuation coefficient (dB/km) – All other applications

Fibre category Maximum attenuation coefficient (dB/km) at wavelengths (nm)

IEC 60793-2-50, B4 (non-zero dispersion shifted) N/A N/A 0,35 0,40 b IEC 60793-2-50, B5 (wideband non-zero dispersion shifted) N/A N/A 0,35 0,40 b IEC 60793-2-50, B6_a1 or B6_a2 (bending loss insensitive) 0,40 0.40 0,30 0,40 b a N/A = not applicable. b 1 625 nm performance is optional, depending on agreement between customer and supplier

Values for IEC 60793-2-50 category B6_b2 and B6_b3 fibres are under consideration

Measurements shall be made in accordance with IEC 60793-1-40.

Fibre bandwidth requirements

There are no bandwidth requirements on single-mode fibre

Cables with multimode fibers must have the uncabled fiber specified according to one of the performance levels outlined in Table D.4, which includes minimum bandwidth (MHz×km), wavelength, and measurement type.

The fibre category and performance level shall be agreed between customer and supplier

Table D.4 – Minimum multimode fibre bandwidth (MHz×km)

Fibre category Nominal core diameter àm

IEC 60793-2-10, A1b 62,5 500 500 na OM2 a N/A = not applicable

(normative) IEC 60794-1-21 Method Exx – Microduct inner clearance test

Object

This test aims to verify the integrity of the inner bore of a microduct after manufacturing or undergoing mechanical or environmental testing, typically for a short length of up to 2 meters of microduct or protected microduct assembly.

General

An inner clearance test involves passing a test object, such as a sphere or a short length of the actual microduct optical fibre cable, through a section of microduct or microduct assembly after manufacturing or testing This test ensures that the microduct has not been significantly damaged during production or subsequent mechanical tests, like a crush test For practical purposes, the test object must be at least 85% of the nominal microduct bore diameter, unless otherwise agreed upon by the supplier and customer.

For testing longer sections of microduct or protected microduct, the test given in IEC 60794-1-

21 Method E23 may be more appropriate.

Sample

The sample is a short (typically 2 m maximum) section of microduct or protected microduct assembly.

Test equipment

A test object, like a sphere or a short segment (e.g., 100 mm) of the actual cable or fiber unit intended for installation, should have a diameter of at least 85% of the nominal microduct bore diameter Additionally, a secure method must be in place to retrieve the sphere or other test object from the far end of the microduct.

Procedure

To install the catcher, position it at the far end of the microduct, then insert the object and let it travel through to the opposite end The most effective technique for this process is to tilt the sample from a horizontal to a vertical orientation.

Requirements

The object must successfully traverse the microduct, ensuring that the permanent deformation of each microduct does not exceed 15% of its nominal diameter, which is deemed to be insignificant damage.

Details to be recorded

NOTE This test method will be considered for inclusion in IEC 60794-1-21