3.1.9 Replacement: 3.1.9 normal operation operation of the machine under the following conditions: the machine is operated at rated voltage with the load necessary to attain rated po
Trang 1BSI Standards Publication
Household and similar electrical appliances — Safety
Part 2-92: Particular requirements for pedestrian-controlled mains-operated lawn scarifiers and aerators
Trang 2This British Standard is the UK implementation of EN50636-2-92:2014 It supersedes BS EN 60335-2-92:2005 which iswithdrawn.
The UK participation in its preparation was entrusted to TechnicalCommittee CPL/116, Safety of motor-operated electric tools
A list of organizations represented on this committee can beobtained on request to its secretary
This publication does not purport to include all the necessaryprovisions of a contract Users are responsible for its correctapplication
© The British Standards Institution 2014 Published by BSI StandardsLimited 2014
ISBN 978 0 580 72077 2ICS 65.060.70; 97.030
Compliance with a British Standard cannot confer immunity from legal obligations.
This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 June 2014
Amendments issued since publication
Trang 3NORME EUROPÉENNE
English Version Household and similar electrical appliances - Safety - Part 2-92:
Particular requirements for pedestrian-controlled mains-operated
lawn scarifiers and aerators
Appareils électrodomestiques et analogues - Sécurité -
Partie 2-92: Règles particulières pour les scarificateurs de
gazon et les aérateurs fonctionnant sur le réseau et pour
conducteur à pied
Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke - Teil 2-92: Besondere Anforderungen für handgeführte netzbetriebene Rasen-Vertikutierer und
Rasen-Lüfter
This European Standard was approved by CENELEC on 2013-09-02 CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member
This European Standard exists in three official versions (English, French, German) A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom
European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members
Ref No EN 50636-2-92:2014 E
Trang 4Contents Page
Foreword 4
Introduction 6
1 Scope 7
2 Normative references 7
3 Terms and definitions 8
4 General requirement 10
5 General conditions for the tests 10
6 Classification 11
7 Marking and instructions 11
8 Protection against access to live parts 14
9 Starting of motor-operated appliances 14
10 Power input and current 14
11 Heating 15
12 Void 15
13 Leakage current and electric strength at operating temperature 15
14 Transient overvoltages 15
15 Moisture resistance 15
16 Leakage current and electric strength 15
17 Overload protection of transformers and associated circuits 15
18 Endurance 15
19 Abnormal operation 16
20 Stability and mechanical hazards 16
21 Mechanical strength 23
22 Construction 24
23 Internal wiring 25
24 Components 25
25 Supply connection and external flexible cords 26
26 Terminals for external conductors 27
27 Provision for earthing 27
28 Screws and connections 27
29 Clearances, creepage distances and solid insulation 27
30 Resistance to heat and fire 27
31 Resistance to rusting 27
32 Radiation, toxicity and similar hazards 27
Annex AA (normative) Safety signs and symbols 39
Annex BB (informative) Safety Instructions 42
Trang 5Annex CC (normative) Vibration 45
Annex DD (normative) Noise test code – Engineering method (grade 2) 50
Annex EE (informative) Example of a material and construction fulfilling the requirements for an artificial surface 56
Annex FF (normative) Base 58
Annex ZZ (informative) Coverage of Essential Requirements of EU Directives 60
Bibliography 61
Figures Figure 101 Safety distances – Machines with more than one axle 28
Figure 102 Safety distances – Single axle machines 29
Figure 103 Foot probe 30
Figure 104 Strength of tine assembly 31
Figure 105 Operator zone 32
Figure 106 Front and rear guarding of tines 33
Figure 107 Side guarding of tines 34
Figure 108 Guarding of rear discharge machines 35
Figure 109 Guarding of front discharge machines 36
Figure 110 Thrown object test rig for rear discharge scarifiers with rigid tines 37
Figure 111 Impact test fixture for handle insulation 38
Figure AA.1 “Read operator’s manual” 39
Figure AA.2 “Keep bystanders away” 40
Figure AA.3 “WARNING – Beware of sharp tines, keep fingers and toes away Remove plug from mains before maintenance, adjusting, cleaning or if the cord is entangled or damaged Tines continue to rotate after the motor is switched off” 40
Figure AA.4 “Keep supply flexible cord away from tines” 41
Figure CC.1 – Examples of transducer location/orientation 47
Figure CC.2 – Examples of transducer location/orientation for hand-arm vibration 48
Figure DD.1 Microphone positions on the hemisphere (see Table DD.1) 51
Figure EE.1 Sketch of the measurement surface covered with an artificial surface (not to scale) 57
Figure FF.1 Base detail 58
Figure FF.2 Nail plan of base 59
Tables Table DD.1 Co-ordinates of microphone positions 52
Table DD.2 Absorption coefficients 53
Trang 6Foreword
This document (EN 50636-2-92:2014) has been prepared by CLC/TC 116 "Safety of motor-operated electric tools"
The following dates are fixed:
• latest date by which this document has to be
implemented
at national level by publication of an identical
national standard or by endorsement
(dop) 2014-12-20
• latest date by which the national standards conflicting
with this document have to be withdrawn (dow) 2016-09-02
This document supersedes EN 60335-2-92:2005
EN 60335-2-92:2014 includes the following significant technical changes:
– rewording of some clauses;
– alignment to the European Machinery Directive 2006/42/EC;
– alignment to EN 60335-1:2012
This document is to be used in conjunction with EN 60335-1:2012 “Household and similar electrical
appliances Safety Part 1: General requirements”
When “Part 1” is mentioned in this standard, it refers to EN 60335-1:2012
This document supplements or modifies the corresponding clauses in Part 1, so as to convert that
publication into the European Standard “Particular requirements for pedestrian-controlled
walk-behind mains operated scarifiers and aerators”
Where a particular subclause of Part 1 is not mentioned in this document, that subclause applies as far as is relevant Where this standard states “addition”, “modification” or “replacement”, the relevant text in Part 1 is to be adapted accordingly
Compliance with the relevant clauses of Part 1 together with this document provides one means of conforming to the specified essential health and safety requirements of the Directive
This European Standard follows the overall requirements of EN ISO 12100
Warning: Other requirements arising from other EU Directives can be applicable to the products falling within the scope of this European Standard
The following numbering system is used:
– subclauses , notes, tables and figures that are numbered starting from 101 are additional to those in Part 1;
– additional annexes are lettered AA, BB, etc.;
Note In this European Standard the following print types are used:
- requirements proper: in roman type;
- test specifications: in italic type;
- explanatory matter: in smaller roman type
Words in bold in the text are defined in Clause 3 When a definition concerns an adjective, the adjective and the associated
noun are also in bold Common modifications are indicated by a vertical line in the left margin of the text
Trang 7Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent rights
This document has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s)
For the relationship with EU Directive(s) see informative Annex ZZ, which is an integral part of this document
Trang 8Introduction
This document is a type C standard as stated in EN ISO 12100
The machinery concerned and the extent to which hazards, hazardous situations and events are covered is as indicated in the scope of this document
When provisions of this type C standard are different from those which are stated in type A or B standards, the provisions of this type C standard take precedence over the other standards, for machines which have been built and designed to the provisions of this type C standard
Trang 91 Scope
This clause of Part 1 is replaced by the following
This European Standard specifies safety requirements and their verification for the design and construction of pedestrian controlled walk-behind mains operated scarifiers and aerators, hereinafter
referred to as ‘machine(s)’, which are designed for re-generating lawns by, for instance, combing out grass, thatch and moss or cutting vertically into the lawn face using tines which rotate about a
horizontal axis This standard applies in conjunction with Part 1
NOTE 1 Lawn scarifiers are also known as lawn rakes.
This European Standard does not apply to non-powered scarifiers and aerators, battery powered scarifiers and aerators, vertical axis scarifiers and aerators or those aerators which cut into the soil by means of a reciprocating motion and ride-on machines
This European Standard does not apply to
– lawnmowers (EN 60335-2-77);
– lawn trimmers (EN 60335-2-91);
– lawn edge trimmers (EN 60335-2-91);
– lawn edgers, flail mowers, sickle-bar mowers or agricultural mowers
This European Standard is not applicable to aerators/scarifiers which are manufactured before the date of publication of this document
This European Standard deals with all the significant hazards presented by pedestrian-controlled lawn scarifiers and lawn aerators when they are used as intended and under conditions of misuse
which are reasonably foreseeable
NOTE 2 Combustion engine machines are covered by EN 13684
EN ISO 2758:2003, Paper Determination of bursting strength (ISO 2758:2001)
EN ISO 3744:2010, Acoustics Determination of sound power levels and sound energy levels of
noise sources using sound pressure Engineering methods for an essentially free field over a reflecting plane (ISO 3744:2010)
EN ISO 4871:2009, Acoustics Declaration and verification of noise emission values of machinery and equipment (ISO 4871:1996)
Trang 10EN ISO 11201:2010, Acoustics Noise emitted by machinery and equipment Determination of
emission sound pressure levels at a work station and at other specified positions in an essentially free field over a reflecting plane with negligible environmental corrections (ISO 11201:2010)
EN ISO 12100:2010, Safety of machinery General principles for design Risk assessment and
risk reduction (ISO 12100:2010)
EN ISO 13857:2008, Safety of machinery Safety distances to prevent hazard zones being reached
by upper and lower limbs (ISO 13857:2008)
EN ISO 20643:2008; Mechanical vibration Hand-held and hand-guided machinery Principles for
evaluation of vibration emission (ISO 20643:2005)
3 Terms and definitions
This clause of Part 1 is applicable except as follows
3.1.9 Replacement:
3.1.9
normal operation
operation of the machine under the following conditions: the machine is operated at rated voltage
with the load necessary to attain rated power input
extension of the tine enclosure from the discharge opening, generally used to control the discharge
of material from the tines
denotes throwing out grass, thatch and moss so that they will be collected in a catcher which is
located in front of the tines
b) rear discharge
denotes throwing out grass, thatch and moss so that they will be collected in a catcher which is
located behind the tines
Trang 113.106
guard
part of the machine or component incorporated to provide protection for the operator and/or bystander
by means of a physical barrier
maximum operating motor speed
highest motor speed obtainable when the motor is adjusted in accordance with the instructions, with the tines engaged
3.113
operator control
any control requiring the operator’s actuation to perform specific functions
3.114
operator presence control
control designed so that it will automatically interrupt power to a drive when the operator's actuating
device incorporated into the machine which, when operated, prevents the machine from moving from
a stationary position and remains applied without the operator present
3.117
pedestrian-controlled
ground-supported, controlled by an operator walking behind
Trang 12tine tip circle
path described by the outermost point of the tine as it rotates about its shaft axis
This clause of Part 1 is applicable
5 General conditions for the tests
This clause of Part 1 is applicable except as follows
5.2 Addition:
Tests carried out in Clauses 20 and 21 require a new machine for each test If testing requires the same test to be carried out on the machine for different functions a new machine shall be used for each test
Trang 136 Classification
This clause of Part 1 is applicable except as follows
6.1 Replacement:
Machines shall be of class II with respect to protection against electric shock
Compliance is checked by inspection and by the relevant tests
6.2 Addition:
Machines shall be at least IPX4
7 Marking and instructions
This clause of Part 1 is applicable except as follows
7.1 Addition:
The machines shall be marked with the following minimum information:
– business name and full address of the manufacturer and, where applicable his authorized representative;
– designation of the machine,
designation of machine may be achieved by a combination of letters and/or numbers The designation may be provided in the form of a code, providing that this code is explained by giving the explicit designation such as “scarifiers” or “aerators”, etc in the instructions supplied with the machine;
NOTE 1 An example of such code is “A123B”
– year of construction, that is the year in which the manufacturing process is completed;
– designation of series or type,
allowing the technical identification of the product This may be achieved by a combination of letters and/or numbers and may be combined with the designation of machine;
NOTE 2 The term “designation of series or type” is also known as model number
– serial number, if any;
– rated power in watts or rated current in amperes;
– guards designed to be opened or removed shall have a sign warning of the relevant hazard visible on the machine both when the guard is closed and when it is opened or removed;
– controls which may give rise to a hazard (e.g operator presence control for the tines) when
operated shall be marked or so placed as to indicate clearly which part of the machine they control;
– mandatory markings;
NOTE 3 For machines and their related products intended to be put on the market in the EEA, CE-marking as defined in the applicable European Directive(s), e.g the Machinery Directive
Where replaceable during normal use, except for spring type tines, the tines shall be marked to
identify the part number(s) and the manufacturer, importer or supplier
Trang 14Marking giving warning information shall be easily legible and located as close as practicable to the relevant hazard
The substance of the following warnings shall be placed in a prominent position on the machine: – WARNING – Read user instructions;
– WARNING – Beware of sharp tines, keep fingers and toes away Remove plug from mains
before maintenance, adjusting, cleaning or if the cord is entangled or damaged;
– Tines continue to rotate after the motor is switched off;
– Keep flexible cord away from the tines;
– Keep bystanders away,
and as appropriate to the machine design:
– Wear eye and/or ear protection
If a pictogram is used it shall be that shown in Annex AA It shall be in contrasting colours to the base material If it is embossed, stamped or cast colours are not required Markings or safety signs giving cautionary information shall be located close to the hazard
Compliance shall be checked by inspection
This instruction manual shall include:
a) a repeat of those warnings required to be marked on the machine together with further explanation, where appropriate Where safety signs are used in the marking on the machine, their function shall be explained;
b) a warning to never allow children, persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge or people unfamiliar with these instructions to use the machine, local regulations may restrict the age of the operator;
c) a warning to never operate the machine while people, especially children, or pets are nearby; d) a general description of the machine, the intended use, instructions for the proper use of the machine including advice on what the machine should be used for, how to use it for the intended purpose(s) and any reasonably foreseeable misuse thereof;
e) warnings concerning ways - that experience has shown might occur - in which the machinery shall not be used;
f) instructions for the proper assembly and disassembly of the machine for use, if the machine is not supplied in a completely assembled form;
Trang 15g) instructions for proper adjustment and any necessary user maintenance of the machine, including timescales and a warning of the danger of moving hazardous parts;
h) instructions for the recommended replacement or repair of, or service attention to, critical components; where parts are consumable, the part number of the spare part shall be specified;
i) instructions on the operation of all controls;
j) information how to start the machine safely, especially with a view to necessary tilting of the machine and keeping both hands in the operating position before returning the machine to the ground;
k) instructions for the operating position and the correct and safe operation of the machine such as moving, safe positioning, handling, clearing blockages and keeping the discharge chute clear of processed material for use, preparation, maintenance and storage of the machine;
l) an advice to not overreach and to keep the balance at all times, to always be sure of the footing
on slopes and to walk, never run;
m) a warning not to touch moving hazardous parts before the machine is disconnected from the mains and the moving hazardous parts have come to a complete stop;
n) an advice on the use, length and type of extension cords to be used (not lighter than required by 25.7);
o) if a collecting facility is provided with the machine, instructions for when and how to attach and detach the collection device to and from the machine;
p) information about the residual risks that remain despite the inherent safe design measures, safeguarding and complementary protective measures adopted;
q) instructions to always wear substantial footwear and long trousers while operating the machine;
r) instructions to disconnect the supply (e.g remove the plug from the mains or remove the disabling device)
1) whenever the machine is left by the user;
2) before clearing a blockage;
3) before checking, cleaning or working on the machine;
4) after striking a foreign object to inspect the machine for damage;
5) if the machine starts to vibrate abnormally, for immediately check;
s) instructions when, where and how to inspect the machine, the supply and extension cord for signs
of damage or ageing and, if permitted, how to make repairs;
t) a warning never to operate the machine with defective guards or shields, or without safety devices, or if the cord is damaged or worn;
u) an advice not to connect a damaged cord to the supply or touch a damaged cord before it is disconnected from the supply for the reason that damaged cords can lead to contact with live parts;
v) an advice to keep extension cords away from moving hazardous parts to avoid damages to the cords which can lead to contact with live parts;
w) the operating method to be followed in the event of accident or breakdown;
x) instructions how to disconnect the machine from the mains, if the cord becomes damaged or entangled during use;
z) information about airborne noise emissions of the machine according to Annex DD, this includes:
1) the A-weighted emission sound pressure level at the operator position as determined according to Annex DD, where this exceeds 70 dB(A); where this level does not exceed
70 dB(A), this fact shall be indicated;
Trang 162) the A-weighted sound power level emitted by the machinery as determined according to Annex DD;
3) the uncertainties surrounding the determined noise emission values according to Annex DD; aa) the vibration total value to which the hands are subjected as determined according to Annex CC, where this exceeds 2,5 m/s²; where this level does not exceed 2,5 m/s², this fact shall be indicated;
bb) the uncertainty of measurement for vibration value;
cc) instructions how to proceed in case of abnormal vibrations;
dd) mass in kilograms
NOTE Examples of safety instructions are given Annex BB
Compliance shall be checked by inspection
7.12.1 This clause of Part 1 is applicable
7.12.5 to 7.12.6 These clauses of Part 1 are applicable
8 Protection against access to live parts
This clause of Part 1 is applicable
9 Starting of motor-operated appliances
This clause of Part 1 is replaced by the following
Motors shall start under all normal voltage conditions which may occur in use
In all cases, the machine shall operate and overload protection devices incorporated in the machine shall not activate Centrifugal and other automatic starting switches, if any, shall operate reliably, and without contact chattering
Compliance is checked by starting the machine three times, at no-load, at a voltage equal to 0,85 times rated voltage or the lower limit of the rated voltage range, with any control device set at
maximum speed
For the test the tines are raised so that they are not in contact with any surface
The machine shall operate in such a way that safety is not affected
10 Power input and current
This clause of Part 1 is applicable except as follows
10.1 This clause of Part 1 is not applicable
Trang 1711 Heating
This clause of Part 1 is applicable except as follows:
11.5 Addition:
The machine shall be operated at rated voltage and rated current or rated power input until a
steady state is reached The torque being applied shall be measured When tested by 0,94 and 1,06 times rated voltage the previously determined torque shall be maintained
12 Void
13 Leakage current and electric strength at operating temperature
This clause of Part 1 is applicable
Air filters are not removed
16 Leakage current and electric strength
This clause of Part 1 is applicable
17 Overload protection of transformers and associated circuits
This clause of Part 1 is applicable
18 Endurance
This clause of Part 1 is applicable except as follows
18.101 Machines shall be so constructed that, in normal use, there will be no electrical or
mechanical failure that might impair compliance with this standard The insulation shall not be damaged, and contacts and connections shall not have worked loose as a result of heating, vibration, etc
Trang 18Moreover, overload devices shall not operate under normal running conditions
Compliance is checked by the tests of Clause 18.102
18.102 The machine is operated at no load, series motors being supplied at a voltage such that the
rotating speed is the same as that obtained at rated voltage and under normal operation The
machine is operated for 48 h, reduced by the running time necessary for the tests of Clauses 11 and
18.103 During the tests of Clause 18.102, overload protective devices shall not operate
After the tests of Clause 18.102 the machine shall withstand the tests of Clause 16 Connections, handles, guards, brush-caps and other fittings or components shall not have worked loose, and there shall be no deterioration impairing safety
19 Abnormal operation
This clause of Part 1 is applicable except as follows
19.7 Addition:
This test is only conducted on machines with fixed or rigid tines
19.9 This clause of Part 1 is not applicable
20 Stability and mechanical hazards
This clause of Part 1 is applicable except as follows
All apertures and safety distances shall conform to the relevant clauses of EN ISO 13857:2008
Rotating covers or discs shall have a continuous unbroken or smooth surface
Where a guard is designed to be opened or removed, thereby exposing a hazard, a safety sign warning of the hazard shall be located on the guard or adjacent to the guard
Trang 19All guards shall be permanently attached to the machine and shall not be detachable without the use
of tools The opening of guards shall require the use of a tool An exceptions to this is the opening of
automatically closing hinged guards for discharge chutes
Fixed guards that the user is instructed to remove for regular maintenance shall have their fixing means retained on either the guard or the body of the machine
Compliance is checked by inspection and measurement
20.101 Power driven components
All power driven components except the tines and the ground-contacting parts of controlled machines with traction drive shall be guarded to prevent contact with these parts during normal operation
pedestrian-All openings and safety distances shall conform to 4.5.2 and 4.5.3 of EN ISO 13857:2008 unless otherwise specified in this standard
Guards shall be provided to prevent accidental contact with hazardous servicing points when the machine is serviced
Compliance is checked by inspection
20.102 Guard attachment
All guards shall be permanently attached to the machine and shall not be detachable without the use
of tools and shall withstand a force of 75 N in any direction
The opening of guards, except for the following, shall require the use of a tool:
– the opening of removable interlocked guards which disable the protected moving parts;
– the opening of hinged, automatically closing guards for debris discharge chutes
Compliance is checked by inspection
20.103 Controls
20.103.1 General
Except as indicated in the following list, controls shall be located within, and have a range of
movement which remains within the anthropometric dimensions given for the operator zone 1 in Figure 105:
– controls for setting the depth of penetration of the tines;
– catcher discharge arrangements;
The operating range of controls that do not require sustained manual actuation may be extended by
allowing the operator’s trunk, when standing with both feet on the ground, to articulate within the confines of the operator zone 2 (e.g lean forward until contacting the handle in any of the operating
positions) The control for lifting the tines off the ground for transportation reasons is regarded to be
such a control
If the control for lifting the tines off the ground for transportation is foot operated it shall be ≤ 450 mm
in front of the handle, measured horizontally from the rearmost point of the handle If the handle is adjustable the ≤ 450 mm dimension shall apply for all positions of the handle
Trang 20It shall not be possible to sustain a motor speed greater than the maximum operating motor speed
by use of any control or by simple adjustments made by using standard tools
On machines with traction drive it shall be possible to engage or disengage the traction drive when
the tines are operating
Compliance shall be checked by inspection
20.103.2 Operator presence control
Machines shall be fitted with a device on the control handle, which will automatically stop tine rotation
when the operator’s hands are removed from the handle This may be accomplished, for example, either by stopping the drive motor or by an intermediate tine clutch mechanism
For restarting tine rotation, the control shall require two separate actions If these actions are to be
carried out by using the same hand then the actions shall be separate and dissimilar in order to prevent accidental “switch on”
Compliance shall be checked by inspection
20.103.3 Traction drive
The control for traction drive shall automatically stop or disengage the traction drive when the
operator's hands are removed from the handle
The reverse function of the traction drive control shall require continuous activation in the direction
of travel to drive It shall not be possible to drive the tines when the traction drive is in reverse
Compliance shall be checked by inspection
20.103.4 Tines
Machines that have a designated position that raises the tines such that they are not in contact with
the ground shall be provided with a means to prevent unintentional contact with the rotating tines
This shall be achieved by one of the following three options:
a) it shall not be possible to raise the tines into a transport position unless the tines are stopped,
and it shall not be possible to engage the drive to the tines when the machine is in the transport
position (i.e the tines are not in contact with the ground); or
b) the tines shall stop within 3 s of the operator presence control being released; or
c) the tine enclosure shall prevent inadvertent foot contact by the operator
Compliance shall be checked for a) by inspection, for b) by measurement and for c) by the foot probe test of Clause 20.109
NOTE The requirements for stopping time test are not included in this standard and can be found in EN 60335-2-77
20.104 Heavy machines – Test method
Heavy machines are required to have a service and parking brake system
Compliance is checked by measurement and the following test
A service and parking brake system is required on machines with a mass greater than 63 kg
NOTE The requirements for service and parking brakes for heavy machines are not included in this standard and can be
found in ISO 5395-2
Trang 2120.105 Vibration reduction
20.105.1 Reduction by design and protective measures
The machine shall be designed to generate a vibration level as low as practicable The main sources causing vibration are
– the oscillating forces from the motor,
– the tine assembly,
– the unbalanced moving parts,
– the impact in gears, bearings and other mechanisms,
– the interaction between operator, machine and material being worked,
– the machine design related to mobility,
– the travelling surface, speed, tyre pressure
Besides the vibration reduction of the source, technical measures to isolate the vibration source from the handle may be used, when appropriate, such as isolators and resonating masses
NOTE CR 1030-1:1995 gives general technical information on widely recognized technical rules and means to be followed in the design of machines for low hand-arm vibration solutions
20.105.2 Reduction by information
After taking possible technical measures for vibration reduction, when appropriate, the instruction manual shall recommend
– the use of low-vibration operating modes, and/or limited time of operation,
– wearing of personal protection equipment (PPE)
20.105.3 Vibration measurement
For the measurement of hand-arm vibration the methods given in Annex CC may be used
20.106 Noise reduction
20.106.1 Reduction at source by design and by protective measures
Noise reduction shall be an integral part of the design process thus specifically taking into account measures at source The success of the applied noise reduction measures are assessed on the basis
of the actual noise emission values (see Annex DD)
The main sources causing noise are:
– air intake system,
– scarifying and aerating system,
– vibrating surfaces
NOTE EN ISO 11688-1:1998 gives general technical information on widely recognized technical rules and means to be followed in the design of low-noise machines
Trang 2220.106.2 Reduction by information
If after taking all possible technical measures for reducing noise at the design stage a manufacturer considers that further protection of the operator is necessary, then the instruction handbook shall: – recommend the use of low-noise operating modes, and/or limited time of operation,
– give a warning of hazardous noise levels and recommend the use of hearing protection
20.106.3 Verification of requirements on noise – Noise measurement
The determination of the sound power level and of the emission sound pressure level at the operator's position shall be carried out using the measurement methods given in Annex DD
20.107 General construction – Guarding
20.107.1 Tines shall be guarded on both sides and from front and rear, so that it is not possible for a
vertical test rod 50 mm in diameter and 500 mm in length, with its lower end in contact with the ground (supporting surface), to approach any portion of the tines within 10 mm when any catcher has been
removed (see Figure 106)
20.107.2 Tines shall be covered at the sides with guards extending at least as shown in Figure 107
With the guard’s edge - from the middle of the tines to the rear - parallel to the ground, the following
shall be:
- max angle at the front opening: 15 °
- the contour 10 mm greater than the tines’ radius
- max distance from the lower guard edge to the ground: max penetration depth (a) plus
25 mm in maximum
20.107.3 Tines of rear discharge machines shall be covered from above with a guard that extends
so that its projection on the horizontal plane covers at least the projection of the tines on the same
horizontal plane, when any catcher has been removed See Figure 108
When the catcher is not fitted to the machine, protection in accordance with Clause 20.107.4 shall be
provided If the full guard less 25 mm maximum height option is chosen the requirement shall be
achieved by a self-closing guard
Compliance is checked by inspection
20.107.4 Tines of front discharge machines shall be covered from the rear with a guard that
extends so that its projection on the vertical plane covers at least the projection of the tines on the
same vertical plane, less up to 25 mm (see Figure 109) or the operator shall be protected against foot contact with the tines from the rear of the machine by complying with the foot probe test of Clause
20.109
Compliance with the requirements of Clause 20.107 shall be checked by inspection and measurement
by the foot probe test of Clause 20.109
On single-axle machines the end of the handle adjacent to the operator shall be at least 600 mm horizontally behind the rear vertical tangent of the tine assembly when the grip of the handle is at a
Trang 23height of 900 mm above the ground (see Figure 102), or the requirements of the foot probe test of Clause 20.109 shall be fulfilled
On machines other than single-axle machines, the end of the handle adjacent to the operator shall be either at least 450 mm horizontally behind the rear vertical tangent of the tine assembly (see
Figure 101), or the requirements of the foot probe test below shall be fulfilled
For a freely pivoting handle, if a handle park position is provided, the handle shall automatically lock back into an operating position when the handle is moved into this position
For easier storage, handles may be unlatched or folded up
Compliance shall be checked by inspection and measurement and, if necessary by the foot probe test
of Clause 20.109
20.109 Foot probe test
The machine shall be placed on a hard flat surface The guards or deflectors or both shall be in the
normal operating position on the tine housing and the support members (wheels) shall be in contact
with the supporting surface The test shall be conducted under static conditions
For single axle machines the test shall be made with the hand grip(s) 900 mm above the ground as shown in Figure 102 and if the tines can be adjusted they shall be tested at the highest and lowest working positions
For other machines the tests shall be made with the tines in the highest and lowest cutting positions
Compliance is checked by the following test
The test fixture shall be a foot probe as specified in Figure 103 The base of the test probe shall be held horizontally at any height and then inclined up to 15° forward or backward from the horizontal The test probe shall be applied at any point of the rear of the housing with a force of 20 N or until the housing or guard moves from its original position, whichever occurs first
The test probe shall not enter the path of the tine assembly
20.110 Thrown object hazard
20.110.1 General
Scarifiers with flail or rigid tines shall be so constructed to provide in intended use adequate
protection against risk of injury to the operator from foreign objects that may be thrown out by the rotating tines
20.110.2 Thrown object test
20.110.2.1 Test personnel
Test personnel should either be kept out of the test area or otherwise protected from the hazards resulting from the following test
20.110.2.2 Test equipment
The machine shall be tested on a test installation as shown in Figure 110
The drawer shall consist of a rigid waterproof material (e.g plastics) and the bottom of the inside of the drawer shall have a coarse surface to avoid movement of the sand-gravel-mixture when the
Trang 24drawer moves towards the machine The width of the drawer shall be at least equal to the width of cut
A uniform sand-gravel-mixture shall be made up by volume of ½ building sand and ½ smooth gravel (pebbles) of grain size between 8 mm and 16 mm The mixture shall be dampened just sufficiently to ensure that the mixture does not separate during the test It shall be kept damp during the test(s)
A single thickness of Kraft paper 1 000 mm wide x 2 000 mm high with nominal 225 g/m² construction, according to EN ISO 2758:2003, shall be affixed to a frame and used as target panel for the operator area and shall be placed behind and in contact with the end of the handle (handle bar grips) and perpendicular to the base The lower edge of the target panel shall be at the height of the wheel's supporting surface The target panel shall be divided by a horizontal line into a lower zone which reaches up to 450 mm from the lower edge and a higher zone which is above 450 mm
20.110.2.3 Test method
The machine shall be tested in all operational configurations (e.g with and without catcher) and the tines (set to the highest speed) shall be operated at the maximum operating motor speed
The handle(s) of the machine shall be set such that the horizontal distance from the rear of the handle
to the tine assembly is a minimum For single axle machines the handle grip height shall be fixed at
900 mm above the ground
The sand-gravel-mixture shall be placed in the drawer and be lightly compressed and flattened to a height of (18 ± 1) mm
The wheels of the machine shall be restrained on supporting cover plates In this position the tines
shall be set to penetrate the surface of the sand-gravel-mixture to a depth of 10 mm or at the next deepest setting For single axle machines the machine ground supports may be lowered to achieve (10 ± 1) mm penetration
The sand/gravel mixture in the drawer shall be moved once from the front towards the rear of the machine into the rotating tines for a distance equal to the diameter of the tine tip circle The speed of
movement of the drawer shall be (1 ± 0,5) m/s
20.110.3 Test results
Holes in the target panel shall be regarded as a hit and shall be scored A nominal 10 mm diameter
steel ball (as used for ball bearings) shall be applied with a force of (3 ± 0,3) N perpendicular to the target material If it passes through the target panel a hit has occurred
20.110.4 Test acceptance (pass/fail criteria)
There shall be not more than five hits in the target panel between the lower edge of the target panel
and the 450 mm line (lower zone) There shall be no hits above the 450 mm line (higher zone)
20.110.5 Additional testing
In case of a failure, two additional tests shall be conducted These additional tests shall either be carried out on the existing machine or, at the option of the manufacturer; new identical machines shall
be tested New sand-gravel-mixture shall be used for each test
If either of the additional tests is failed, the model shall have failed the test
Trang 25Guards and their mountings shall have adequate strength to withstand impact with solid objects
The following test shall be carried out on the guard when the temperature of the parts to be tested has
stabilised to an ambient temperature of (20 ± 3) °C After the test the guard shall not have become
detached nor show any visible cracks Screws and retaining clips shall be secure and the requirements of Clauses 20.107.1, 20.107.2 and 20.107.3 shall still be met
Each of three samples of the complete machine shall be subjected to an impact of (6,5 ± 0,2) J on a part of the guard likely to be the weakest, with the machine resting on a smooth, rigid, level surface
The tests shall be so conducted that in each test the sample receives an impact in a location different from the other two tests
The impact shall be produced with a smooth solid steel sphere (as used for ball bearings) having a diameter of 50 mm If the part being tested is at an angle of up to 45° to the horizontal, the sphere shall be allowed to fall vertically from rest to strike the part Otherwise, the sphere shall be suspended
by a cord and shall be allowed to fall from rest as a pendulum to strike the part In either case, the vertical travel of the sphere shall be 1,3 m
21.102 Strength of tines and tine mountings
Tines and their mountings shall have adequate strength to withstand impact with solid objects
Compliance shall be checked by the following test Test personnel should either be kept out of the test area or otherwise protected from the hazards resulting from the following test
The test shall be done at the maximum operating motor speed, with the tine drive engaged and
shall be carried out on all tine assemblies
The machine shall be mounted on a flat, horizontal surface The handle of the machine shall be restrained elastically Single-axle machines shall be positioned so that the handle grip is 900 mm above the level of the mounting surface
The mounting of the machine shall allow for an upward movement of the machine
A steel plate 8 mm thick, 400 mm long and wide enough to hit all of the tines of the tine assemblies at
one pass shall be mounted on the upper surface of a carriage which is located at the tine tip circle of
the machine (see Figure 104) The carriage shall be pulled centrally under the tine assembly from the
front of the machine toward the rear The speed of the pull shall be 1 m/s ± 5 % The test is then repeated with the carriage being pulled under the tine assembly from the rear towards the front
During the test, no complete tine or parts thereof shall break off and there shall be no visible cracks
Chipping of tines or breakage of parts intended to break such as shearing pins shall not be
considered a failure The tines need not be suitable for further use after the test Ejection of small
chips of machine parts not exceeding 2 g shall be ignored
Trang 26For class II machines:
Handles and operator controls which are held when operating the machine shall either be of
insulating material or covered by insulating material having a thickness of at least 1 mm, or separated
by insulation equivalent to supplementary insulation from other accessible metal parts
Handle shafts shall be:
a) of insulating material, or,
b) if not of insulating material, covered with insulating material having a thickness of at least 1 mm which extends for a distance of 150 mm from handles and handle mounted operator controls
and by insulation equivalent to supplementary insulation from other accessible metal parts
which are within 75 mm of the ground measured as a clearance or from accessible metal parts connected to such parts
Cable restraints/guides are not considered to be operator controls
Compliance is checked by inspection, by measurement and, for the covering of insulating material on handles, operator controls and handle shafts, by the following tests
A sample of the covered part is conditioned at a temperature of 70 °C ± 2 °C for 7 days (168 h) After conditioning, the sample is allowed to attain approximately room temperature
Inspection shall show that the covering has not shrunk to such an extent that the required length of
150 mm or the required insulation is no longer given, or that the covering has not peeled off and that it may move longitudinally
After this, the sample is maintained for 4 h at a temperature of -10 °C ± 2 °C
While still at this temperature, the sample is then subjected to impact by means of the apparatus shown in Figure 111 The weight A having a mass of 300 g falls from a height of 350 mm onto the chisel B of hardened steel, the edge of which is placed on the sample
One impact is applied to each place where the covering is likely to be weak or damaged in intended use, the distance between the points of impact being at least 10 mm
After this test, inspection shall show that the covering has not peeled off and an electric strength test is made between metal parts and metal foil wrapped round the covering in the area required to be insulated
The test voltage of 1 750 V is applied for 1 min
During this test, no flashover or breakdown shall occur
Trang 2722.36 This subclause does not apply
22.101 Machines shall be provided with a means such that damage to the supply cable due to
movement of the machine is prevented as far as possible The means provided shall be re-usable
This requirement is considered to be met by, for example,
– a cable-retaining device to keep the cable out of the vicinity of the tines, to which the cable may
be adequately fastened, or
– the supply cable entry or attachment being at least 0,6 m from the nearest point of the tines
Compliance is checked by inspection and by the following test procedure, except for automatic cord reel-in devices
The supply cable as delivered with the machine is attached to the cable-retaining device in accordance with the instruction manual The supply cord is then subjected 10 times to a pull of
100 N, the pull being applied in the most unfavourable direction, without jerks, for 1 s
After the test the power supply cord shall show no damage within the meaning of this standard and it
shall not have been displaced longitudinally, in the device, by more than 2 mm
22.102 Air filters which can be removed for cleaning purposes shall be so designed that they are
unlikely to come off during use
This requirement is met if, for example, the air filter
– can only be removed with the aid of a tool, or
– is provided with a spring that prevents it from falling away, during use, due to vibration, or
– needs a deliberate action of the user for its removal
Compliance is checked by inspection
Trang 2825 Supply connection and external flexible cords
This clause of Part 1 is applicable except as follows
25.1 Replacement:
Machines shall be provided with a supply cord or a machine inlet
Machine inlets shall not allow the introduction of a connector complying with the standard sheets of
EN 60320 series except EN 60320-2-3
Compliance is checked by inspection
25.5 Replacement:
Machines shall be provided with one of the following:
– a supply cord not less than 10 m in length with type X attachment, or
– a supply cord of length not exceeding 0,5 m with type X or Y attachment and terminating in a
cable coupler or,
– a machine inlet
Compliance is checked by inspection
25.7 Modification:
Replace the first paragraph by the following:
Supply cords shall not be lighter than
– if rubber insulated, ordinary tough rubber sheathed flexible cord (code designation HO5 RN-F); – if polyvinyl chloride insulated, ordinary polyvinyl chloride sheathed flexible cord (code designation HO5 VV-F)
25.14 Addition:
This requirement also applies to external cables or cords where, because of the design of the machine, there is relative movement of more than 45° of the cable or cord at its point of entry into an enclosure
25.15 Addition:
This requirement applies to all accessible cables or cords
Replace the fourth paragraph:
A mark shall be made on the cord on the machine side of the cord anchorage while it is subject to the pull force shown in Table 12, at a distance of approximately 2 cm from the cord anchorage or other suitable point If access to the machine side of the cord anchorage is not practicable then the mark shall be made on the supply side of the anchorage and it shall be ensured that the pull force is applied
to the cord in such a way that, at the point of application of the force, the sheath of the cord does not move with respect to the conductors or their insulation
25.15 Modification of Table 12, column 2, rows 3, 4 and 5:
The pull force on the supply cord shall be 150 N
Trang 2926 Terminals for external conductors
This clause of Part 1 is applicable
27 Provision for earthing
This clause of Part 1 is applicable
28 Screws and connections
This clause of Part 1 is applicable except as follows
28.1 Addition:
Screws or nuts for fastening the tines may be of insulating material or covered with insulating material,
provided they cannot be replaced by readily available metal screws or nuts
29 Clearances, creepage distances and solid insulation
This clause of Part 1 is applicable except as follows
29.2 Addition:
Pollution degree 3 applies to this machine
30 Resistance to heat and fire
This clause of Part 1 is applicable except as follows
30.2.3 Not applicable
31 Resistance to rusting
This clause of Part 1 is applicable
32 Radiation, toxicity and similar hazards
This clause of Part 1 is not applicable
Trang 32Dimensions in mm
Figure 103 Foot probe
Trang 33W dimension of steel plate sufficient to make contact with the tines over the full width of the tine assemblies
Figure 104 Strength of tine assembly