Tiêu đề Multi-element Metallic Cables Used In Analogue And Digital Communication And Control Part 5-1: Sectional Specification For Screened Cables Characterized Up To 250 MHz — Horizontal And Building Backbone Cables
Trường học British Standards Institution
Chuyên ngành Standards Publication
Thể loại standards publication
Năm xuất bản 2014
Thành phố Brussels
Định dạng
Số trang 20
Dung lượng 0,94 MB

Các công cụ chuyển đổi và chỉnh sửa cho tài liệu này

Nội dung

BSI Standards Publication BS EN 50288 5 1 2013 Multi element metallic cables used in analogue and digital communication and control Part 5 1 Sectional specification for screened cables characterized u[.]

Trang 1

BSI Standards Publication

Multi-element metallic cables used in analogue and digital communication and control

-Part 5-1: Sectional specification for screened cables characterized up to 250 MHz — Horizontal and building backbone cables

Trang 2

This British Standard is the UK implementation of EN 50288-5-1:2013 It supersedes BS EN 50288-5-1:2003 which is withdrawn

The UK participation in its preparation was entrusted to Technical Committee EPL/46, Cables, wires and waveguides, radio frequency connectors and accessories for communication and signalling

A list of organizations represented on this committee can be obtained on request to its secretary

This publication does not purport to include all the necessary provisions of a contract Users are responsible for its correct application

© The British Standards Institution 2014 Published by BSI Standards Limited 2014

ISBN 978 0 580 77100 2 ICS 33.120.20

Compliance with a British Standard cannot confer immunity from legal obligations.

This British Standard was published under the authority of the Standards Policy and Strategy Committee on 28 February 2014

Amendments issued since publication

Date Text affected

Trang 3

EN 50288-5-1

NORME EUROPÉENNE

CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members

Ref No EN 50288-5-1:2013 E

English version

Multi-element metallic cables used in analogue and digital communication

and control - Part 5-1: Sectional specification for screened cables characterized up to

250 MHz - Horizontal and building backbone cables

Câbles métalliques à éléments multiples

utilisés pour les transmissions et les

commandes analogiques et numériques -

Partie 5-1: Spécification intermédiaire

pour les câbles blindés pour applications

jusqu'à 250 MHz -

Câbles horizontaux et câbles verticaux de

bâtiment

Mehradrige metallische Daten- und Kontrollkabel für analoge und digitale Übertragung -

Teil 5-1: Rahmenspezifikation für geschirmte Kabel bis 250 MHz - Kabel für den Horizontal- und Steigbereich

This European Standard was approved by CENELEC on 2013-03-18 CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration

Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member

This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified

to the CEN-CENELEC Management Centre has the same status as the official versions

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom

Trang 4

Contents

Page

Foreword 3

1 Scope 4

2 Normative references 4

3 Terms, definitions, symbols and abbreviations 4

3.1 Terms and definitions 4

3.2 Symbols and abbreviations 4

4 Cable construction 5

4.1 Conductor 5

4.2 Insulation 5

4.3 Cabling elements 5

4.4 Identification of cabling elements 5

4.5 Screening of cabling elements 5

4.6 Cable make-up 5

4.7 Filling compound 5

4.8 Interstitial fillers 5

4.9 Screening of the cable core 5

4.10 Moisture barriers 5

4.11 Wrapping layers 5

4.12 Sheath 6

5 Tests and requirements for completed cables 6

5.1 Electrical tests 6

5.2 Mechanical tests 9

5.3 Environmental tests 10

5.4 Fire performance tests 10

Annex A (informative) Maximum voltage, current and temperature rating for cables used for POE applications 12

Annex B (informative) Blank detail specification 13

Trang 5

Foreword

This document (EN 50288-5-1:2013) has been prepared by CLC/SC 46XC "Multicore, Multipair and Quad Data communication cables," of CLC/TC 46X, "Communication cables"

The following dates are fixed:

• latest date by which this document has

to be implemented at national level by

publication of an identical national standard

or by endorsement

(dop) 2014-03-18

• latest date by which the national

standards conflicting with this document

have to be withdrawn

(dow) 2016-03-18 This document supersedes EN 50288-5-1:2003

EN 5-1:2013 includes the following significant technical changes with respect to EN 50288-5-1:2003:

− the addition of the Blank Detail Specification Annex;

− a number minor corrections and updating of references;

− the re-classification of ‘ELFEXT’ to ‘ACR-F’

This Part 5-1 is to be read in conjunction to EN 50288-1

Attention is drawn to the possibility that some of the elements of this document may be the subject

of patent rights CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent rights

This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC)

Trang 6

1 Scope

EN 50288-5-1 is a sectional specification for screened cables, characterised from 1 MHz up to 250 MHz,

to be used in horizontal and building backbone wiring as defined in EN 50173

This sectional specification contains the electrical, mechanical, transmission and environmental performance characteristics of the cables, when tested in accordance with the referenced test methods This sectional specification is to be read in conjunction with EN 50288-1 that contains the essential provisions for its application

The cables covered in this sectional specification are intended to operate with voltages and currents normally encountered in communication systems These cables are not intended to be used in conjunction with low impedance sources, for example, the electric power supplies of public utility mains

2 Normative references

The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies

EN 50173 Series Information technology - Generic cabling systems

EN 50288-1 Multi-element metallic cables used in analogue and digital

communication and control - Part 1: Generic specification

EN 50289 Series Communication cables - Specifications for test methods

EN 50290 Series Communication cables

EN 60811 Series Electric and optical fibre cables - Test methods for non-metallic

materials (IEC 60811 series)

IEC 60189-2 Low-frequency cables and wires with PVC insulation and PVC

sheath - Part 2: Cables in pairs, triples, quads and quintuples for inside installations

3 Terms, definitions, symbols and abbreviations

3.1 Terms and definitions

For the purposes of this document the terms and definitions given in EN 50288-1 and the following apply

3.1.1

screening of cable

a cable is considered screened when the cable core is covered by a continuous conductive layer forming part of the shielding and grounding system

Note 1 to entry: d.c continuity has to be given and minimum shielding requirements have to be met

3.2 Symbols and abbreviations

For the purposes of this document, the following abbreviations apply

EX Exogenous (derived or originating externally) POE Power Over Ethernet

Trang 7

4 Cable construction

4.1 Conductor

The conductor shall be solid copper and meet the requirements of EN 50288-1, 4.1

The conductor shall be plain or metal coated

The nominal conductor diameter shall be ≥ 0,5 mm and ≤ 0,8 mm

NOTE Constructions with ‘copper clad’ conductors do not meet the requirements

4.2 Insulation

The insulation shall be of a suitable material according to the relevant part of EN 50290-2

4.3 Cabling elements

The cable element shall be a pair or a quad

4.4 Identification of cabling elements

Unless otherwise specified, the colour coding for identification is given in IEC 60189-2 The colours shall meet the requirements of EN 50288-1, 4.4

4.5 Screening of cabling elements

Where appropriate, screening of the cabling elements shall be applied in accordance with 4.5 of

EN 50288-1 Coverage is defined in EN 50290-2-1

4.6 Cable make-up

The cable elements shall be laid up in concentric layer(s) or units to form the cable core

4.7 Filling compound

Not applicable

4.8 Interstitial fillers

Where fillers are used they shall meet the requirements of 4.8 of EN 50288-1

4.9 Screening of the cable core

The screening of the cable core shall be applied in accordance with EN 50288-1, 4.9 Coverage is defined

in EN 50290-2-1

4.10 Moisture barriers

Not applicable

4.11 Wrapping layers

Where wrapping layers are used they shall be in accordance with EN 50288-1, 4.11

Trang 8

4.12 Sheath

The sheath shall be of a suitable material according to the relevant part of EN 50290-2

5 Tests and requirements for completed cables

The following tables give the tests to be applied, together with the respective limits, in order to demonstrate compliance with this specification

5.1 Electrical tests

5.1.1 Low-frequency and d.c electrical measurements

Table 1 -Low-frequency and d.c electrical measurements

EN 50288-1

5.1.1.1 Conductor loop resistance ≤ 19,0 Ω/100 m

5.1.1.2 Conductor resistance unbalance ≤ 2,0 %

5.1.1.2.1 Pair resistance unbalance ≤ 4,0 %

5.1.1.3 Dielectric strength

conductor/conductor and conductor/screen

1,0 kV d.c or 0,7 kV a.c for 1 min

or 2,5 kV d.c or 1,7 kV a.c for 2 s 5.1.1.4 Insulation resistance ≥ 5 000 MΩ km when tested in accordance with EN

50289-1-4 5.1.1.5 Mutual capacitance No requirement specified

5.1.1.6 Capacitance unbalance to earth ≤ 1 200 pF/km

Trang 9

5.1.2 High-frequency electrical and transmission measurements

Table 2 - High-frequency electrical and transmission requirements

EN 50288-1

sub-clause Parameter Requirement

5.1.2.1 Velocity of

propagation Phase delay ≤ 534+36/√f ns/100 m, 1 MHz ≤ f ≤ 250 MHz 5.1.2.2 Propagation delay

difference (skew) ≤ 45 ns/100 m at 100 MHz 5.1.2.3 Longitudinal

attenuation 2) 3) 4)

5.1.2.4 Near-end

unbalance attenuation

≥ 40-10log(f) dB, 1 MHz ≤ f ≤ 250 MHz;

5.1.2.5 Near-end crosstalk

(NEXT) 1) 2)

5.1.2.6 Attenuation to

crosstalk ratio at the far end 2) 6) (ACR-F)

1 4 10 16 20 31,2

5 62,5 100 155 200 250 MHz 66,0 58,0 50,0 45,9 44,0 40,1 34,1 30,0 26,2 24,0 22,0 dB

≥ 70-20log(f), 1 MHz ≤ f ≤ 250 MHz (maximum 66 dB), values referenced to 100 m

5.1.2.7.1 Power sum

near-end crosstalk 2)

(PSNEXT)

1 4 10 16 20 31,2

5 62,5 100 155 200 250 MHz 72.3 63,3 57,3 54,2 52,8 49,9 45,4 42,3 39,4 37,8 36,3 dB

≥ 72,3-15log(f), 1 MHz ≤ f ≤ 250 MHz 5.1.2.7.2 Power Sum

Attenuation to crosstalk ratio at the far end 2) 6) (PSACR-F)

1 4 10 16 20 31,2

5 62,5 100 155 200 250 MHz 64,0 55,0 47,0 43,0 41,0 37,1 31,1 27,0 23,2 21,0 19,0 dB

≥ 67-20log(f), 1 MHz ≤ f ≤ 250 MHz (maximum 64 dB), values referenced to 100 m

5.1.2.8 Mean characteristic

impedance 100 Ω ± 5 Ω, 120 Ω ± 5 Ω, at 100 MHz

1 4 10 16 20 31,25 62,5 100 155 200 250 MHz 2,1 3,8 6,0 7,6 8,5 10,8 15,5 19,9 25,3 29,1 33,0 dB/100 m

α ≤1,82√f+0,0169f+0,25 /√f, 1 MHz ≤ f ≤ 250 MHz

1 4 10 16 20 31,25 62,5 100 155 200 250 MHz

75 66 60,3 57,2 55,8 52,9 48,4 45,3 42,4 40,8 39,3 dB

≥ 75-15log(f), 1 MHz ≤ f ≤ 250 MHz

Trang 10

5.1.2.9 Return loss 2) 5) 4 8 10 16 20 31,2

5 62,5 100 155 200 250 MHz 23,1 24,5 25,0 25,0 25,0 23,6 21,5 20,1 18,8 18,0 17,3 dB

≥ 20+5log(f), 4 MHz ≤ f ≤ 10 MHz; 25,0dB, 10 MHz < f ≤ 20 MHz; 25-7log(f/20), 20 MHz < f ≤ 250 MHz;

5.1.2.10 Coupling

attenuation Type I ≥ 85dB , 30 MHz ≤ f ≤ 100 MHz 85 - 20 log f/100 dB 100 MHz ≤ f ≤ 1000 MHz

Type Ib ≥ 70dB , 30 MHz ≤ f ≤ 100 MHz 70 - 20 log f/100 dB 100 MHz ≤ f ≤

1000 MHz Type II ≥ 55dB, 30 MHz ≤ f ≤ 100 MHz 55 - 20 log f/100 dB 100 MHz ≤ f ≤

1000 MHz 5.1.2.11 Transfer impedance Grade 1

≤ 10 mΩ/m at 1 MHz;

≤ 10 mΩ/m at 10 MHz;

≤ 30 mΩ/m at 30 MHz;

≤ 100 mΩ/m at 100 MHz Grade 2

≤ 50 mΩ/m at 1 MHz;

≤ 100 mΩ/m at 10 MHz;

≤ 200 mΩ/m at 30 MHz;

≤ 1000mΩ/m at 100 MHz

1) For hybrid cables and multi-unit cables, PSNEXT between all non fibre recognised cable units shall be 3 dB better than the specified pair to pair NEXT at all specified frequencies

2) The values in the table are for information only The formula given shall be used to determine compliance, rounded to one decimal place

3) The attenuation shall meet values adjusted for temperature up to 60 °C with a temperature coefficient of 0,2 % per degree rise above 20 °C

4) Values between 1 MHz and 4 MHz are for information only

5) For the measurement of return loss a test sample having a round trip loss ≥ 40 dB at any measured frequency should be used

6) ELFEXT is now re-classified as ACR-F, PSELFEXT is now re-classified PSACR-F, see Annex A of EN 50288-1 for explanation

Trang 11

5.2 Mechanical tests

Table 3 - Mechanical test requirements

EN 50288-1

5.2.1 Conductor elongation at break

EN 50289-3-2 ≥ 10 % 5.2.2 Shrinkage of insulation

EN 50289-3-4 ≤ 5 % 5.2.3 Crush resistance of the cable

EN 50289-3-5

1 000 N / 1 min / 100 mm Near-end crosstalk, return loss and characteristic impedance shall remain within the specified limits 5.2.4 Impact resistance of the cable

EN 50289-3-6

12,5 mm radius / 1 J / 3 impacts at 1 m from the measured end

Near-end crosstalk, return loss and characteristic impedance shall remain within the specified limits 5.2.5 Abrasion resistance of the sheath

marking

EN 50289-3-8

Marking shall remain legible after 10 strokes Force 4N

5.2.6 Simulated installation testing of the

cable 5.2.6.1 Simulated installation testing of the

cable Single bend

EN 50289-3-9:2001, Clause 4, procedure 2

Single bend

4 × dia / 4 cycles Near-end crosstalk, return loss, characteristic impedance and coupling attenuation (u/c) shall remain within the specified limits

5.2.6.2 Simulated installation testing of the

cable

“S” bend

EN 50289-3-9:2001, Clause 8

“S” bend

8 × dia / 100 m / 1 cycle / 120 deg / 1 m/s Near-end crosstalk, return loss, characteristic impedance and coupling attenuation (u/c) shall remain within the specified limits

5.2.7 Tensile performance

EN 50289-3-16 combined with 5.2.6 of this standard

Load shall be 25 N per pair (i.e.100 N for 4 pairs) Near-end crosstalk, return loss, characteristic impedance and coupling attenuation (u/c) shall remain within the specified limits