BSI Standards PublicationAerospace series — Electrical cables, installation — Protective sleeves in meta-aramid fibres Part 008: Self-wrapping shielded EMI protective sleeve with nickel
Trang 1BSI Standards Publication
Aerospace series — Electrical cables, installation — Protective sleeves in meta-aramid fibres
Part 008: Self-wrapping shielded (EMI) protective sleeve with nickel copper braid, flexible post installation operating
temperature from — 55 °C to 200 °C — Product standard
Trang 2The UK participation in its preparation was entrusted to Technical Committee ACE/6, Aerospace avionic electrical and fibre optic technology
A list of organizations represented on this committee can be obtained on request to its secretary
This publication does not purport to include all the necessary provisions of a contract Users are responsible for its correct application
© The British Standards Institution 2013
Published by BSI Standards Limited 2013
ISBN 978 0 580 66794 7 ICS 49.060
Compliance with a British Standard cannot confer immunity from legal obligations.
This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2013
Amendments issued since publication Date Text affected
Trang 3NORME EUROPÉENNE
ICS 49.060
English Version Aerospace series - Electrical cables, installation - Protective
sleeves in meta-aramid fibres - Part 008: Self-wrapping shielded
(EMI) protective sleeve with nickel copper braid, flexible post
installation operating temperature from - 55 °C to 200 °C -
Product standard
Série aérospatiale - Câbles électriques, installation -
Gaines de protection en fibres méta-aramides - Partie 008:
Gaine de protection blindée (EMI) auto-fermable avec
tresse cuivre nickelée, souple après montage température
d'utilisation - 55 °C à 200 °C - Norme de produit
Luft- und Raumfahrt - Elektrische Leitungen, Installation - Schutzschläuche aus Meta-Aramidfasern - Teil 008: Selbstverschließender Schutzschlauch, geschirmt (EMI), mit Nickel-Kupfer-Geflecht, flexibel, nachträglich montierbar, Betriebstemperatur -55 °C bis 200 °C -
Produktnorm
This European Standard was approved by CEN on 3 May 2012
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member
This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom
EUROPEAN COMMITTEE FOR STANDARDIZATION
C O M I T É E U R O P É E N D E N O R M A L I S A T I O N
E U R O P Ä I S C H E S K O M I T E E FÜ R N O R M U N G
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2013 CEN All rights of exploitation in any form and by any means reserved
worldwide for CEN national Members
Ref No EN 6049-008:2013: E
Trang 4Contents Page
Foreword 3
1 Scope 4
2 Normative references 4
3 Terms and definitions 5
4 Required characteristics 5
5 Test methods 9
6 Designation 12
7 Marking 12
Trang 5Foreword
This document (EN 6049-008:2013) has been prepared by the Aerospace and Defence Industries Association
of Europe - Standardization (ASD-STAN)
After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN
This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by July 2013, and conflicting national standards shall be withdrawn at the latest by July 2013
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom
Trang 61 Scope
This European Standard specifies the characteristics of post installation flexible self-wrapping EMI shielding protection sleeves for electrical cable and cable bundles made from meta-aramid fibres for the external sleeve, and nickel copper plated braid as the internal layer and provided with a water repellent protection for aerospace application
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies
EN 2825, Aerospace series — Burning behaviour of non metallic materials under the influence of radiating heat and flames — Determination of smoke density
EN 2826, Aerospace series — Burning behaviour of non metallic materials under the influence of radiating heat and flames — Determination of gas components in the smoke
EN 2591-214, Aerospace series — Elements of electrical and optical connection — Test methods — Part 214: Lightning strike, current and voltage pulse
EN 2591-305, Aerospace series — Elements of electrical and optical connection — Test methods — Part 305: Rapid change of temperature
EN 2591-307, Aerospace series — Elements of electrical and optical connection — Test methods — Part 307: Salt mist
EN 3475-301, Aerospace series — Cables, electrical, aircraft use — Test methods — Part 301: Ohmic resistance per unit length
EN 3475-705, Aerospace series — Cables, electrical, aircraft use — Test methods — Part 705: Contrast measurement
EN 3844-1, Aerospace series — Flammability of non metallic materials — Part 1: Small burner test, vertical — Determination of the vertical flame propagation
EN 6049-001, Aerospace series — Electrical cables, installation — Protection sleeve in meta-aramid fibres — Part 001: Technical specification 1)
EN 6059 (all parts), Aerospace series — Electrical cables, installation — Protection sleeves — Test methods
1) Published as ASD-STAN Prestandard at the date of publication of this standard (www.asd-stan.org)
Trang 7IEC 60096-0-1, Radio-frequency cables — Part 0: Guide to the design of detailed specifications — Section 1: Coaxial cables 2)
ASTM B355, Standard Specification for Nickel-Coated Soft or Annealed Copper Wire 3)
ASTM D1000, Standard Test Methods for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applications 3)
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 6049-001 and the following apply
3.1
after ageing
the ageing is to be understood as the effect of environmental test(s) listed in section 5 on the product performance at the end of a qualification test group
3.2
overlap angle
sleeve overlap angle for maximum wire bundle diameter
4 Required characteristics
4.1 Composition
A textile and metal openable, self-wrappable sleeving made of two layers:
External layer: a woven blend of textured meta-aramid continuous yarn and polyphenylene sulfide (PPS) monofilament A specific feature avoids excessive fraying of the sleeving after cold cutting
Internal layer: a metallic flat braid made of nickel copper strands as per ASTM B355 Class 27, with an option of adhesive polytetrafluoroethylene (PTFE) tape as per ASTM D1000
2) Published by: IEC International Commission Electrotechnique Internationale http://www.iec.ch/
3) Published by: ASTM National (US) American Society for Testing and Materials http://www.astm.org/
Trang 84.2 Dimensions and mass of the sleeve
See Figure 1, Table 1 and Table 2
Key
1 90° of overlap
2 Sleeve identification by a blue tracer line separated by a green Nomex filament at this longitudinal edge
3 Overlap angle
4 Ivory tracer indicating the maximum operating diameter
5 Mandrel diameter = maximum bundle diameter Indicated per internal ivory line for maximum permissible bundle diameter
Figure 1 — Configuration Table 1 — Dimensions and mass (without adhesive PTFE tape layer)
Size
code
Overlap angle measured
on a mandrel
Wall thickness
Diameters
to be protected
Procurement length
Maximum mass
06
2,35 1 to 6
11
1,60
25
116
23
Trang 9Table 2 — Dimensions and mass (with adhesive PTFE tape layer)
Size
code
Overlap angle measured
on a mandrel
Wall thickness
Diameters
to be protected
Procurement length
Maximum mass
06
2,44 1 to 6
11
1,69
25
132
23
4.3 Colour, materials and tracer line identification
4.3.1 Colour
In accordance with Table 3
Table 3 — Colour
4.3.2 Materials
External layer: The materials shall be multifilament fibres of meta-aramid and PPS monofilament and meet
the requirements as specified in this standard
Internal layer: The material shall be metallic nickel copper flat braid Strands shall be in accordance with
ASTM B355 Class 27
4.3.3 Tracer line identification
The sleeve is delivered with a blue “tracer line” with a width of 9 mm over its complete length marked to identify the shielding protection The blue tracer line shall remain visible when installed on a harness of the minimum or maximum diameter as per Table 1 or Table 2
4.3.4 Adhesive PTFE tape
The sleeve can be delivered with an adhesive PTFE tape as per ASTM D1000 for electrical insulation between the cables and the metallic flat braid; see Table 4
Trang 10Table 4 — Adhesive PTFE tape designation code
4.3.5 Temperature range
The operational temperature of the protection sleeves shall be from − 55 °C to 200 °C
4.4 Electrical characteristics for EMH protection
4.4.1 Electrical resistance requirement
In accordance with Table 5
Table 5 — Electrical resistance requirement
Size
code
DC Electrical resistance
Ro max
mΩ/m
Electrical Impedance ≤≤≤≤ 10 KHz
Zt; (10 kHz) max
mΩ/m Before ageing After ageing Before ageing After ageing
4.4.2 Transfer impedance requirement
After ageing, the transfer impedance curve (see Figure 2) shall be below:
2 t
2 o
t max (R max.) (L max.ω)
with
Ro max = See Table 5, Column “Electrical Impedance ≤ 10 KHz Zt(10 kHz) max.”;
Lt max = 0,6 nH/m;
ω = 2·π·F;
π = 3,141 6
Trang 11where
F = the frequency in Hz;
Zt max = transfer impedance maximum acceptable
Frequencies (Hz)
Figure 2 — Transfer impedance curve (size 06 shown)
5 Test methods
5.1 Standard tests
The tests shall be carried out as shown in Table 6
For the number of samples to be tested, see EN 6049-001
Trang 12Table 6 — Test methods and details (1 of 2)
EN 6059-201 Visual examination See 4.1 and 4.2
EN 6059-202 Dimensions and mass See 4.2
EN 6059-203 Coverage Not applicable
EN 6059-301 Sun light exposure For 40 h, the retention of the tensile strength shall be 45 %
minimum
EN 6059-302 High temperature
exposure
The specimen shall be within the overwrap tolerances, see Table 1 and tensile strength test, according to EN 6059-404, shall be carried out The value shall not be less than 0,010 N per dTex
EN 6059-303 Resistance to fluids The specimen must show no evidence of deformation swelling,
shrinking, cracking or rupture and a tensile strength test according to EN 6059-404 shall be carried out The value shall not be less than 0,010 N per dTex
EN 3844-1 B Flammability After burn length (average) shall not exceed 203 mm
(8 inches) After flame time (average) shall not exceed 15 s After flame time drips (average) shall not exceed 5 s
EN 6059-305 Fluid absorption The specimen shall repel water for 6 h after test according to
EN 6059–302
EN 6059-306 Mould growth There shall no external deterioration that would affect service
use and no mould growth visible to the naked eye
EN 6059-401 Expansion range Not applicable
EN 6059-402 Bending properties A medium size specimen installed on aerospace cable, twisted
two turns per metre tied every 10 cm, loaded with 10 N must not show any evidence of deformation, swelling, cracking or more than 10 % of rupture of metallic filament after 200 cycles
EN 6059-403 Scrape abrasion Needle load shall be 10 N
EN 6059-404 Tensile strength The tensile force to be applied per dTex shall not be less than
0,02 N Degradation of the tensile strength after environmental tests shall be within the limits as mentioned in the relevant paragraph For this test, unwoven tows of the batch, which have been used for weaving of the sleeves, may be used
EN 6059-405 Dynamic cut through The test shall be carried out at ambient temperature Load shall be
30 N
EN 6059-406 Vibration After the endurance test performed in accordance with
EN 6059-406, no evidence of wear or defect must be visible on the wires
EN 2825 B Smoke density The test duration shall be 4 min The maximum specific optical
smoke density (average) shall not exceed:
Ds = 200 (flaming mode)
Ds = 150 (non flaming mode)
Trang 13Table 6 — Test methods and details (2 of 2)
EN 2826 B Toxicity Gas component Limit of concentration (ppm)
(duration 4 min)
Hydrogen fluoride HF Hydrogen chloride HCI Hydrogen cyanide HCN Sulphur dioxide SO2/H2S Nitrous gases NO/NO2
Carbon monoxide CO
100
150
150
100
100
1 000
EN 3475-301 Ohmic resistance per unit
EN 3475-705 Contrast measurement 50 % minimum between the tracer line and the sleeve
IEC 60096 Transfer impedance Triaxial method
See 4.4.2
EN 2591-214 Lightning test Waveform 1, 10 kA
EN 2591-305 Rapid variations of
temperature TA= 200 °C
TB=− 55 °C
EN 2591-307 Salt mist 500 h
5.2 Endurance tests
The tests shall be carried out as shown in Table 7
Unless otherwise specified in the concerned technical product standard, at least one size of protection sleeve per sleeve thickness or construction type (if different from one size to another) shall be assessed
If possible for each thickness or construction type the test must be performed on a sample having the minimum authorized thickness or minimum authorized weight
Table 7 — Test groups (1 of 2)
Group 0
Ohmic resistance per unit length a EN 3475-301
Group 1
Ohmic resistance per unit length a EN 3475-301