BSI Standards Publication UK National Annex to Eurocode 3 Design of steel structures Part 1 1 General rules and rules for buildings NA+A1 2014 to BS EN 1993 1 1 2005+A1 2014 NA+A1 2014 to BS EN 1993 1[.]

Trang 1

BSI Standards Publication

UK National Annex to Eurocode 3: Design of steel structures

Part 1-1: General rules and rules for buildings

Trang 2

Publishing and copyright information

The BSI copyright notice displayed in this document indicates when the document was last issued

© The British Standards Institution 2015

Published by BSI Standards Limited 2015 ISBN 978 0 580 86667 8

ICS 91.080.10 The following BSI references relate to the work on this standard:

Committee reference CB/203 Draft for comment 15/30301400DC

Publication history

First published December 2008

Amendments issued since publication

30 June 2015 National amendment A1:2014 See Introduction

for details

Trang 3

Contents

Introduction 1

NA.1 Scope 1 NA.2 Nationally Determined Parameters 1 NA.3 Decisions on the status of informative annexes 8 NA.4 References to non-contradictory complementary information 9

Bibliography 10

Tables

Table NA.1 – Selection of buckling curve for a cross-section 5 Table NA.2 – Suggested limits for vertical deflections 6 Table NA.3 – Suggested limits for horizontal deflections 7 Table NA.4 – Scope and conditions of application of execution class 8

Trang 4

This page deliberately left blank

Trang 5

National Annex (informative) to

BS EN 1993-1-1:2005, Eurocode 3: Design

of steel structures – Part 1-1: General rules and rules for buildings

Introduction

This National Annex has been prepared by BSI Subcommittee CB/203,

Design & execution of steel structures It is to be used in conjunction

with BS EN 1993-1-1:2005+A1:2014

NA+A1:2014 to BS EN 1993-1-1:2005+A1:2014 supersedes

NA to BS EN 1993-1-1:2005, which is withdrawn

The start and finish of text introduced or altered by National Amendment 1 is indicated in the text by tags  Minor editorial changes are not tagged

NA.1 Scope

This National Annex gives:

a) the decisions for the National Determined Parameters described

in the following subclauses of BS EN 1993-1-1:2005+A1:2014:

2.3.1(1)5.3.2(3)6.3.2.4(2)B

3.1(2)5.3.2(11)6.3.3(5)

3.2.1(1)5.3.4(3)6.3.4(1)

3.2.2(1)6.1(1)7.2.1(1)B

3.2.3(1)6.1(1)B7.2.2(1)B

3.2.3(3)B6.3.2.2(2)7.2.3(1)B

3.2.4(1)B6.3.2.3(1)BB.1.3(3)B

5.2.1(3)6.3.2.3(2)C.2.2(3)

5.2.2(8)6.3.2.4(1)BC.2.2(4)

b) Decisions on the status of BS EN 1993-1-1:2005+A1:2014 informative annexes; and

c) References to non-contradictory complementary information

NA.2 Nationally Determined Parameters

Decisions for the Nationally Determined Parameters decided in

BS EN 1993-1-1:2005+A1:2014 are given in clauses NA.2.2 to NA.2.27.

NA.2.2 Actions and environmental influences

[BS EN 1993-1-1:2005+A1:2014, 2.3.1(1)]

There are no additional regional, climatic or accidental situations

to consider

Trang 6

NA.2.3 Other Steel material and products

[BS EN 1993-1-1:2005+A1:2014, 3.1(2)]

If other steels are used, due allowance should be made for variations in properties, including ductility and weldability Further information on the ductility requirements for steel is given in

BS EN 1993-1-1:2005+A1:2014, 3.2.2(1).

Steel castings and forgings may be used for components in bearings, junctions and other similar parts Castings should conform to

BS EN 10293 and forgings should conform to BS EN 10250-2 Further guidance on steel castings is given in reference [1]

For higher strength steels see BS EN 1993-1-12

NA.2.4 Material properties

[BS EN 1993-1-1:2005+A1:2014, 3.2.1(1)]

The nominal values of the yield strength fy and the ultimate strength

fu for structural steel should be those obtained from the product standard The ultimate strength fu should be taken as the lowest value

of the range given for Rm in the product standard Further information

on the yield and ultimate strength for structural steel is also given in

NA.4.

NA.2.5 Ductility requirements

[BS EN 1993-1-1:2005+A1:2014, 3.2.2(1)]

a) Elastic global analysis The limiting values for the ratio fu/fy, the elongation at failure and the ultimate strain εu for elastic global analysis are given below

fu/fy, H 1.10;

Elongation at failure not less than 15%;

εu H 15εy b) Plastic global analysis Plastic global analysis should not be used for bridges For buildings the limiting values for the ratio fu/fy, the elongation at failure and the ultimate strain εu for plastic global analysis are given below

fu/fy H 1.15;

Elongation at failure not less than 15%;

εu H 20εy

[BS EN 1993-1-1:2005+A1:2014, 3.2.3(1)]

For buildings and other quasi-statically loaded structures the lowest service temperature in the steel should be taken as the lowest air temperature which may be taken as −5°C for internal steelwork and

−15°C for external steelwork

For bridges the lowest service temperature in the steel should be determined according to the NA to BS EN 1991-1-5 for the bridge location For structures susceptible to fatigue it is recommended that the requirements for bridges should be applied

Trang 7

In other cases (e.g the internal steelwork in cold stores) the lowest service temperature in the steel should be taken as the lowest air temperature expected to occur within the intended design life of the structure

NA.2.7 Toughness properties for members in compression

[BS EN 1993-1-1:2005+A1:2014, 3.2.3(3)B]

The recommendations given in the NA to BS EN 1993-1-10 should

be used

NA.2.8 Through-thickness properties

[BS EN 1993-1-1:2005+A1:2014, 3.2.4(1)B]

The recommendations given in the NA to BS EN 1993-1-10 should

be used

NA.2.9 Effects of deformed geometry of the structure

[BS EN 1993-1-1:2005+A1:2014, 5.2.1(3)]

For plastic analysis of clad structures provided that the stiffening effects of masonry infill wall panels or diaphragms of profiled steel sheeting are not taken into account:

αcr H 10 For plastic analysis of portal frames subject to gravity loads only with frame imperfections:

αcr H 5 provided the following conditions are satisfied:

a) The span, L, does not exceed 5 times the mean height of the columns

b) hr satisfies the criterion:

(hr/sa)2 + (hr/sb)2 G 0.5

in which sa and sb are the horizontal distances from the apex

to the columns

NOTE For a symmetrical frame this expression simplifies to

hr G 0.25L.

NA.2.10 Structural stability of frames

[BS EN 1993-1-1:2005+A1:2014, 5.2.2(8)]

This method should only be used for frames that comply with 5.2.2(6)

In such cases the sway moments in the beams and beam-to-column connections should be multiplied by kr unless a smaller value is shown

to be adequate by analysis kr may be evaluated using the following expression provided that acr H 3.0:

kr= 1

1− 1

αcr

Trang 8

NA.2.11 Design values of initial local bow imperfection

[BS EN 1993-1-1:2005+A1:2014, 5.3.2(3)]

For elastic analysis of the cross-section, the initial imperfections for an individual section about a particular axis should be back-calculated from the formula for the buckling curves given in

BS EN 1993-1-1:2005+A1:2014, 6.3 using the elastic section modulus.

For plastic analysis of the cross-section, the initial imperfections for an individual section about a particular axis should be back-calculated from the formula for the buckling curves given

in BS EN 1993-1-1:2005+A1:2014, 6.3 using the full plastic section

modulus

NA.2.12 Amplitude of imperfections

[BS EN 1993-1-1:2005+A1:2014, 5.3.2(11)]

The method given in BS EN 1993-1-1:2005+A1:2014, 5.3.2(11) should

not be used for buildings

NA.2.13 Imperfections for lateral-torsional bucking in bending

[BS EN 1993-1-1:2005+A1:2014, 5.3.4(3)]

The value of k should be taken as 1.0

NA.2.14 Partial factors for structures not covered by BS EN 1993

Part 2 to Part 6 [BS EN 1993-1-1:2005+A1:2014, 6.1(1)]

For structures not covered by BS EN 1993 Part 2 to Part 6, the partial factors should be appropriate for the structure and agreed with the client

NA.2.15 Partial safety factors for buildings

[BS EN 1993-1-1:2005+A1:2014, 6.1(1)]

For buildings the following partial factors should be used:

γM0 = 1.00

γM1 = 1.00

γM2 = 1.10

NA.2.16 Imperfection factors for lateral torsional buckling

[BS EN 1993-1-1:2005+A1:2014, 6.3.2.2(2)]

The recommended values given in BS EN 1993-1-1:2005+A1:2014, Table 6.3 and Table 6.4 should be used

Trang 9

NA.2.17 Lateral torsional buckling for rolled

sections or equivalent welded sections [BS EN 1993-1-1:2005+A1:2014, 6.3.2.3(1)]

For buildings and bridges the following values of λLT,0 and β should be used:

a) For rolled sections and hot-finished and cold-formed hollow sections:

λLT,0 = 0.4

β = 0.75 b) For welded sections:

λLT,0 = 0.2

β = 1.00

BS EN 1993-1-1:2005+A1:2014, Table 6.5 should be replaced with Table NA.1:

Table NA.1 Selection of buckling curve for a cross-section

curve

Rolled doubly symmetric I and H sections and hot-finished

hollow sections

h/b G 2 2.0 < h/b G 3.1 h/b > 3.1

b c d Angles (for moments in the major principal plane)

All other hot-rolled sections

d d Welded doubly symmetric sections and cold-formed

hollow sections

h/b G 2 2.0 G h/b < 3.1

c d

NA.2.18 Modification factor, f

[BS EN 1993-1-1:2005+A1:2014, 6.3.2.3(2)]

The recommended expression for f should be used in which kc is given by:

kc= 1

C1 where:

C1=Mcr for the actual bending moment diagram

Mcr for a uniform bending moment diagram values of C1 are given in the references listed in NA.4

NA.2.19 The slenderness limit λc0

[BS EN 1993-1-1:2005+A1:2014, 6.3.2.4(1)B]

For I, H, channel and box sections used in buildings the value of λc0

should be taken as 0.4

Trang 10

NA.2.20 Modification factor, kfl

[BS EN 1993-1-1:2005+A1:2014, 6.3.2.4(2)B]

The value of the modification factor kfl should be taken as:

kfl = 1.0 for hot rolled I-sections;

kfl =1.0 for welded I-sections with h/b G 2;

kfl = 0.9 for other sections

NA.2.21 Interactions factors kyy, kyz, kzy and kzz

[BS EN 1993-1-1:2005+A1:2014, 6.3.3(5)]

The interaction factors kyy, kyz, kzy, kzz for doubly symmetric sections may be determined using either alternative Method 1 (given in

BS EN 1993-1-1:2005+A1:2014, Annex A) or alternative Method 2 (given in BS EN 1993-1-1:2005+A1:2014, Annex B) Alternative Method 2 (given in BS EN 1993-1-1:2005+A1:2014, Annex B) may also

be used for sections that are not doubly symmetric when modified in

accordance with NA.3.2

NA.2.22 General method for lateral and lateral

torsional buckling of structural components [BS EN 1993-1-1:2005+A1:2014, 6.3.4(1)]

This method is only valid for nominally straight components subject to in-plane monoaxial bending and/or compression

In this method χop should be taken as the minimum value

of χ and χLT Where χ is determined in accordance with

BS EN 1993-1-1:2005+A1:2014, 6.3.1 for lateral buckling and χLT is

determined in accordance with BS EN 1993-1-1:2005+A1:2014, 6.3.2

for lateral torsional buckling

NA.2.23 Vertical deflections

[BS EN 1993-1-1:2005+A1:2014, 7.2.1(1)B]

Table NA.2 gives suggested limits for calculated vertical deflections

of certain members under the characteristic load combination due to variable loads and should not include permanent loads Circumstances may arise where greater or lesser values would be more appropriate Other members may also need deflection limits

On low pitch and flat roofs the possibility of ponding should be investigated

Table NA.2 Suggested limits for vertical deflections

Vertical deflection

Beams carrying plaster or other brittle finish Span/360

Other beams (except purlins and sheeting rails) Span/200

Purlins and sheeting rails To suit the characteristics of particular cladding

Trang 11

NA.2.24 Horizontal deflections

[BS EN 1993-1-1:2005+A1:2014, 7.2.2(1)B]

Table NA.3 gives suggested limits for calculated horizontal deflections

of certain members under the characteristic load combination due to variable load Circumstances may arise where greater or lesser values would be more appropriate Other members may also need deflection limits

Table NA.3 Suggested limits for horizontal deflections

Horizontal deflection

Tops of columns in single-storey buildings except

portal frames

Height/300

Columns in portal frame buildings, not

supporting crane runways

To suit the characteristics of the particular cladding

In each storey of a building with more than one

storey

Height of that storey/300

[BS EN 1993-1-1:2005+A1:2014, 7.2.3(1)B]

Reference should be made to specialist literature as appropriate For

floor vibrations see NA.4.

NA.2.26 Hollow section buckling lengths in lattice girders

[BS EN 1993-1-1:2005+A1:2014, BB.1.3(3)B]

The recommended values may be used and further information is

given in NA.4.

NA.2.27 Selection of execution class

[BS EN 1993-1-1:2005+A1:2014, C.2.2(3) and C.2.2(4)]

BS EN 1993-1-1:2005+A1:2014, Table C.1 should not be adopted Decisions for the selection of reliability class and consequences class are given in clause NA.2.27.2

Decisions for the selection of execution class (EXC) are given in clause NA.2.27.3

NA.2.27.2 Selection of reliability class and consequences class

If the application of design rules in a particular part of BS EN 1993 is specified in terms of reliability class (RC) or consequences class (CC), such classes should apply

Otherwise it should be assumed that the design rules in BS EN 1993 are safe for classes up to and including RC2 and CC2, as defined in

BS EN 1990.

Trang 12

NA.2.27.3 Selection of execution class

Execution class should be selected taking into account the parts of

BS EN 1993 and other Eurocodes that are applicable to the design of the structure

The selection of execution class is given in Table NA.4

NOTE 1 In order to ensure full compatibility with the design resistance values in BS EN 1993, technical requirements in BS EN 1090-2 relating to certain execution classes might need to be enhanced Guidance is given

in PD 6705-2 for designs to BS EN 1993-2 Subject to the limitations in its scope of materials and processes, PD 6705-2 might also be used to provide guidance for other designs covered by Table NA.4 If BS EN 1998 applies to a design, Quantified Service Categories F71, F90 and F112 might

be deemed to apply to yielding/dissipative elements with ductility classes DCL, DCM and DCH respectively.

Table NA.4 Scope and conditions of application of execution class

Parts of BS EN 1993 which are

applicable to the design of the

structure(1)

All relevant Parts except Part 1-9 or Part 1-12

All relevant Parts including Part 1-9 and/or Part 1-12

Other Eurocodes

applicable to the

design of the

structure(1) (in addition

to BS EN 1990 and

BS EN 1991)

Optional BS EN 1994 BS EN 1994 BS EN 1994

Execution classes RC1, CC1,

RC2, CC2

Minimum EXC2 Generally EXC3 Generally EXC3

Note:

(1) Or a distinct, clearly identifiable zone of a structure

No guidance on the scope of application of EXC1 is given The scope

of application of EXC1 in the NOTE to BS EN 1993-1-1:2005+A1:2014, C.2.2(4) is not endorsed for general use

NOTE 2 The use of EXC1 generally provides a lower level of assurance

of attaining the design resistance values in BS EN 1993 If the proposed specification of EXC1 by a specifier, either in full or in part, does not take this into account, its use might result in a higher probability of structural failure than is normally accepted for most structures in the UK.

NA.3 Decisions on the status of informative

annexes

NA.3.1 BS EN 1993-1-1:2005+A1:2014, Annex A

BS EN 1993-1-1:2005+A1:2014, Annex A may be used The scope

of Method 1 given in Annex A should be limited to doubly symmetric sections