BSI Standards Publication UK National Annex to Eurocode 3 Design of steel structures Part 1 1 General rules and rules for buildings NA+A1 2014 to BS EN 1993 1 1 2005+A1 2014 NA+A1 2014 to BS EN 1993 1[.]
Trang 1BSI Standards Publication
UK National Annex to Eurocode 3: Design of steel structures
Part 1-1: General rules and rules for buildings
Trang 2Publishing and copyright information
The BSI copyright notice displayed in this document indicates when the document was last issued
© The British Standards Institution 2015
Published by BSI Standards Limited 2015 ISBN 978 0 580 86667 8
ICS 91.080.10 The following BSI references relate to the work on this standard:
Committee reference CB/203 Draft for comment 15/30301400DC
Publication history
First published December 2008
Amendments issued since publication
30 June 2015 National amendment A1:2014 See Introduction
for details
Trang 3Contents
Introduction 1
NA.1 Scope 1 NA.2 Nationally Determined Parameters 1 NA.3 Decisions on the status of informative annexes 8 NA.4 References to non-contradictory complementary information 9
Bibliography 10
Tables
Table NA.1 – Selection of buckling curve for a cross-section 5 Table NA.2 – Suggested limits for vertical deflections 6 Table NA.3 – Suggested limits for horizontal deflections 7 Table NA.4 – Scope and conditions of application of execution class 8
Trang 4This page deliberately left blank
Trang 5National Annex (informative) to
BS EN 1993-1-1:2005, Eurocode 3: Design
of steel structures – Part 1-1: General rules and rules for buildings
Introduction
This National Annex has been prepared by BSI Subcommittee CB/203,
Design & execution of steel structures It is to be used in conjunction
with BS EN 1993-1-1:2005+A1:2014
NA+A1:2014 to BS EN 1993-1-1:2005+A1:2014 supersedes
NA to BS EN 1993-1-1:2005, which is withdrawn
The start and finish of text introduced or altered by National Amendment 1 is indicated in the text by tags Minor editorial changes are not tagged
NA.1 Scope
This National Annex gives:
a) the decisions for the National Determined Parameters described
in the following subclauses of BS EN 1993-1-1:2005+A1:2014:
• 2.3.1(1) • 5.3.2(3) • 6.3.2.4(2)B
• 3.1(2) • 5.3.2(11) • 6.3.3(5)
• 3.2.1(1) • 5.3.4(3) • 6.3.4(1)
• 3.2.2(1) • 6.1(1) • 7.2.1(1)B
• 3.2.3(1) • 6.1(1)B • 7.2.2(1)B
• 3.2.3(3)B • 6.3.2.2(2) • 7.2.3(1)B
• 3.2.4(1)B • 6.3.2.3(1) • BB.1.3(3)B
• 5.2.1(3) • 6.3.2.3(2) • C.2.2(3)
• 5.2.2(8) • 6.3.2.4(1)B • C.2.2(4)
b) Decisions on the status of BS EN 1993-1-1:2005+A1:2014 informative annexes; and
c) References to non-contradictory complementary information
NA.2 Nationally Determined Parameters
Decisions for the Nationally Determined Parameters decided in
BS EN 1993-1-1:2005+A1:2014 are given in clauses NA.2.2 to NA.2.27.
NA.2.2 Actions and environmental influences
[BS EN 1993-1-1:2005+A1:2014, 2.3.1(1)]
There are no additional regional, climatic or accidental situations
to consider
Trang 6NA.2.3 Other Steel material and products
[BS EN 1993-1-1:2005+A1:2014, 3.1(2)]
If other steels are used, due allowance should be made for variations in properties, including ductility and weldability Further information on the ductility requirements for steel is given in
BS EN 1993-1-1:2005+A1:2014, 3.2.2(1).
Steel castings and forgings may be used for components in bearings, junctions and other similar parts Castings should conform to
BS EN 10293 and forgings should conform to BS EN 10250-2 Further guidance on steel castings is given in reference [1]
For higher strength steels see BS EN 1993-1-12
NA.2.4 Material properties
[BS EN 1993-1-1:2005+A1:2014, 3.2.1(1)]
The nominal values of the yield strength fy and the ultimate strength
fu for structural steel should be those obtained from the product standard The ultimate strength fu should be taken as the lowest value
of the range given for Rm in the product standard Further information
on the yield and ultimate strength for structural steel is also given in
NA.4.
NA.2.5 Ductility requirements
[BS EN 1993-1-1:2005+A1:2014, 3.2.2(1)]
a) Elastic global analysis The limiting values for the ratio fu/fy, the elongation at failure and the ultimate strain εu for elastic global analysis are given below
fu/fy, H 1.10;
Elongation at failure not less than 15%;
εu H 15εy b) Plastic global analysis Plastic global analysis should not be used for bridges For buildings the limiting values for the ratio fu/fy, the elongation at failure and the ultimate strain εu for plastic global analysis are given below
fu/fy H 1.15;
Elongation at failure not less than 15%;
εu H 20εy
[BS EN 1993-1-1:2005+A1:2014, 3.2.3(1)]
For buildings and other quasi-statically loaded structures the lowest service temperature in the steel should be taken as the lowest air temperature which may be taken as −5°C for internal steelwork and
−15°C for external steelwork
For bridges the lowest service temperature in the steel should be determined according to the NA to BS EN 1991-1-5 for the bridge location For structures susceptible to fatigue it is recommended that the requirements for bridges should be applied
Trang 7In other cases (e.g the internal steelwork in cold stores) the lowest service temperature in the steel should be taken as the lowest air temperature expected to occur within the intended design life of the structure
NA.2.7 Toughness properties for members in compression
[BS EN 1993-1-1:2005+A1:2014, 3.2.3(3)B]
The recommendations given in the NA to BS EN 1993-1-10 should
be used
NA.2.8 Through-thickness properties
[BS EN 1993-1-1:2005+A1:2014, 3.2.4(1)B]
The recommendations given in the NA to BS EN 1993-1-10 should
be used
NA.2.9 Effects of deformed geometry of the structure
[BS EN 1993-1-1:2005+A1:2014, 5.2.1(3)]
For plastic analysis of clad structures provided that the stiffening effects of masonry infill wall panels or diaphragms of profiled steel sheeting are not taken into account:
αcr H 10 For plastic analysis of portal frames subject to gravity loads only with frame imperfections:
αcr H 5 provided the following conditions are satisfied:
a) The span, L, does not exceed 5 times the mean height of the columns
b) hr satisfies the criterion:
(hr/sa)2 + (hr/sb)2 G 0.5
in which sa and sb are the horizontal distances from the apex
to the columns
NOTE For a symmetrical frame this expression simplifies to
hr G 0.25L.
NA.2.10 Structural stability of frames
[BS EN 1993-1-1:2005+A1:2014, 5.2.2(8)]
This method should only be used for frames that comply with 5.2.2(6)
In such cases the sway moments in the beams and beam-to-column connections should be multiplied by kr unless a smaller value is shown
to be adequate by analysis kr may be evaluated using the following expression provided that acr H 3.0:
kr= 1
1− 1
αcr
Trang 8NA.2.11 Design values of initial local bow imperfection
[BS EN 1993-1-1:2005+A1:2014, 5.3.2(3)]
For elastic analysis of the cross-section, the initial imperfections for an individual section about a particular axis should be back-calculated from the formula for the buckling curves given in
BS EN 1993-1-1:2005+A1:2014, 6.3 using the elastic section modulus.
For plastic analysis of the cross-section, the initial imperfections for an individual section about a particular axis should be back-calculated from the formula for the buckling curves given
in BS EN 1993-1-1:2005+A1:2014, 6.3 using the full plastic section
modulus
NA.2.12 Amplitude of imperfections
[BS EN 1993-1-1:2005+A1:2014, 5.3.2(11)]
The method given in BS EN 1993-1-1:2005+A1:2014, 5.3.2(11) should
not be used for buildings
NA.2.13 Imperfections for lateral-torsional bucking in bending
[BS EN 1993-1-1:2005+A1:2014, 5.3.4(3)]
The value of k should be taken as 1.0
NA.2.14 Partial factors for structures not covered by BS EN 1993
Part 2 to Part 6 [BS EN 1993-1-1:2005+A1:2014, 6.1(1)]
For structures not covered by BS EN 1993 Part 2 to Part 6, the partial factors should be appropriate for the structure and agreed with the client
NA.2.15 Partial safety factors for buildings
[BS EN 1993-1-1:2005+A1:2014, 6.1(1)]
For buildings the following partial factors should be used:
γM0 = 1.00
γM1 = 1.00
γM2 = 1.10
NA.2.16 Imperfection factors for lateral torsional buckling
[BS EN 1993-1-1:2005+A1:2014, 6.3.2.2(2)]
The recommended values given in BS EN 1993-1-1:2005+A1:2014, Table 6.3 and Table 6.4 should be used
Trang 9NA.2.17 Lateral torsional buckling for rolled
sections or equivalent welded sections [BS EN 1993-1-1:2005+A1:2014, 6.3.2.3(1)]
For buildings and bridges the following values of λLT,0 and β should be used:
a) For rolled sections and hot-finished and cold-formed hollow sections:
λLT,0 = 0.4
β = 0.75 b) For welded sections:
λLT,0 = 0.2
β = 1.00
BS EN 1993-1-1:2005+A1:2014, Table 6.5 should be replaced with Table NA.1:
Table NA.1 Selection of buckling curve for a cross-section
curve
Rolled doubly symmetric I and H sections and hot-finished
hollow sections
h/b G 2 2.0 < h/b G 3.1 h/b > 3.1
b c d Angles (for moments in the major principal plane)
All other hot-rolled sections
d d Welded doubly symmetric sections and cold-formed
hollow sections
h/b G 2 2.0 G h/b < 3.1
c d
NA.2.18 Modification factor, f
[BS EN 1993-1-1:2005+A1:2014, 6.3.2.3(2)]
The recommended expression for f should be used in which kc is given by:
kc= 1
C1 where:
C1=Mcr for the actual bending moment diagram
Mcr for a uniform bending moment diagram values of C1 are given in the references listed in NA.4
NA.2.19 The slenderness limit λc0
[BS EN 1993-1-1:2005+A1:2014, 6.3.2.4(1)B]
For I, H, channel and box sections used in buildings the value of λc0
should be taken as 0.4
Trang 10NA.2.20 Modification factor, kfl
[BS EN 1993-1-1:2005+A1:2014, 6.3.2.4(2)B]
The value of the modification factor kfl should be taken as:
kfl = 1.0 for hot rolled I-sections;
kfl =1.0 for welded I-sections with h/b G 2;
kfl = 0.9 for other sections
NA.2.21 Interactions factors kyy, kyz, kzy and kzz
[BS EN 1993-1-1:2005+A1:2014, 6.3.3(5)]
The interaction factors kyy, kyz, kzy, kzz for doubly symmetric sections may be determined using either alternative Method 1 (given in
BS EN 1993-1-1:2005+A1:2014, Annex A) or alternative Method 2 (given in BS EN 1993-1-1:2005+A1:2014, Annex B) Alternative Method 2 (given in BS EN 1993-1-1:2005+A1:2014, Annex B) may also
be used for sections that are not doubly symmetric when modified in
accordance with NA.3.2
NA.2.22 General method for lateral and lateral
torsional buckling of structural components [BS EN 1993-1-1:2005+A1:2014, 6.3.4(1)]
This method is only valid for nominally straight components subject to in-plane monoaxial bending and/or compression
In this method χop should be taken as the minimum value
of χ and χLT Where χ is determined in accordance with
BS EN 1993-1-1:2005+A1:2014, 6.3.1 for lateral buckling and χLT is
determined in accordance with BS EN 1993-1-1:2005+A1:2014, 6.3.2
for lateral torsional buckling
NA.2.23 Vertical deflections
[BS EN 1993-1-1:2005+A1:2014, 7.2.1(1)B]
Table NA.2 gives suggested limits for calculated vertical deflections
of certain members under the characteristic load combination due to variable loads and should not include permanent loads Circumstances may arise where greater or lesser values would be more appropriate Other members may also need deflection limits
On low pitch and flat roofs the possibility of ponding should be investigated
Table NA.2 Suggested limits for vertical deflections
Vertical deflection
Beams carrying plaster or other brittle finish Span/360
Other beams (except purlins and sheeting rails) Span/200
Purlins and sheeting rails To suit the characteristics of particular cladding
Trang 11NA.2.24 Horizontal deflections
[BS EN 1993-1-1:2005+A1:2014, 7.2.2(1)B]
Table NA.3 gives suggested limits for calculated horizontal deflections
of certain members under the characteristic load combination due to variable load Circumstances may arise where greater or lesser values would be more appropriate Other members may also need deflection limits
Table NA.3 Suggested limits for horizontal deflections
Horizontal deflection
Tops of columns in single-storey buildings except
portal frames
Height/300
Columns in portal frame buildings, not
supporting crane runways
To suit the characteristics of the particular cladding
In each storey of a building with more than one
storey
Height of that storey/300
[BS EN 1993-1-1:2005+A1:2014, 7.2.3(1)B]
Reference should be made to specialist literature as appropriate For
floor vibrations see NA.4.
NA.2.26 Hollow section buckling lengths in lattice girders
[BS EN 1993-1-1:2005+A1:2014, BB.1.3(3)B]
The recommended values may be used and further information is
given in NA.4.
NA.2.27 Selection of execution class
[BS EN 1993-1-1:2005+A1:2014, C.2.2(3) and C.2.2(4)]
BS EN 1993-1-1:2005+A1:2014, Table C.1 should not be adopted Decisions for the selection of reliability class and consequences class are given in clause NA.2.27.2
Decisions for the selection of execution class (EXC) are given in clause NA.2.27.3
NA.2.27.2 Selection of reliability class and consequences class
If the application of design rules in a particular part of BS EN 1993 is specified in terms of reliability class (RC) or consequences class (CC), such classes should apply
Otherwise it should be assumed that the design rules in BS EN 1993 are safe for classes up to and including RC2 and CC2, as defined in
BS EN 1990.
Trang 12NA.2.27.3 Selection of execution class
Execution class should be selected taking into account the parts of
BS EN 1993 and other Eurocodes that are applicable to the design of the structure
The selection of execution class is given in Table NA.4
NOTE 1 In order to ensure full compatibility with the design resistance values in BS EN 1993, technical requirements in BS EN 1090-2 relating to certain execution classes might need to be enhanced Guidance is given
in PD 6705-2 for designs to BS EN 1993-2 Subject to the limitations in its scope of materials and processes, PD 6705-2 might also be used to provide guidance for other designs covered by Table NA.4 If BS EN 1998 applies to a design, Quantified Service Categories F71, F90 and F112 might
be deemed to apply to yielding/dissipative elements with ductility classes DCL, DCM and DCH respectively.
Table NA.4 Scope and conditions of application of execution class
Parts of BS EN 1993 which are
applicable to the design of the
structure(1)
All relevant Parts except Part 1-9 or Part 1-12
All relevant Parts including Part 1-9 and/or Part 1-12
Other Eurocodes
applicable to the
design of the
structure(1) (in addition
to BS EN 1990 and
BS EN 1991)
Optional BS EN 1994 BS EN 1994 BS EN 1994
Execution classes RC1, CC1,
RC2, CC2
Minimum EXC2 Generally EXC3 Generally EXC3
Note:
(1) Or a distinct, clearly identifiable zone of a structure
No guidance on the scope of application of EXC1 is given The scope
of application of EXC1 in the NOTE to BS EN 1993-1-1:2005+A1:2014, C.2.2(4) is not endorsed for general use
NOTE 2 The use of EXC1 generally provides a lower level of assurance
of attaining the design resistance values in BS EN 1993 If the proposed specification of EXC1 by a specifier, either in full or in part, does not take this into account, its use might result in a higher probability of structural failure than is normally accepted for most structures in the UK.
NA.3 Decisions on the status of informative
annexes
NA.3.1 BS EN 1993-1-1:2005+A1:2014, Annex A
BS EN 1993-1-1:2005+A1:2014, Annex A may be used The scope
of Method 1 given in Annex A should be limited to doubly symmetric sections