1. Trang chủ
  2. » Giáo án - Bài giảng

pilot study of a rapid and minimally instrumented sputum sample preparation method for molecular diagnosis of tuberculosis

8 0 0

Đang tải... (xem toàn văn)

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Tiêu đề Pilot Study of a Rapid and Minimally Instrumented Sputum Sample Preparation Method for Molecular Diagnosis of Tuberculosis
Tác giả Tanya M. Ferguson, Kris M.. Weigel, Annie Lakey Becker, Delia Ontengco, Masahiro Narita, Ilya Tolstorukov, Robert Doebler, Gerard A.. Cangelosi, Angelika Niemz
Trường học University of Washington
Chuyên ngành Medical Microbiology, Molecular Diagnostics
Thể loại Research Article
Năm xuất bản 2016
Thành phố Seattle
Định dạng
Số trang 8
Dung lượng 514,23 KB

Các công cụ chuyển đổi và chỉnh sửa cho tài liệu này

Nội dung

Pilot study of a rapid and minimally instrumented sputum sample preparation method for molecular diagnosis of tuberculosis Tanya M.. In conjunction with this sputum disinfection and liq

Trang 1

Pilot study of a rapid and minimally instrumented sputum sample

preparation method for molecular diagnosis of tuberculosis

Tanya M Ferguson1, Kris M Weigel2,3, Annie Lakey Becker2,3, Delia Ontengco3,4, Masahiro Narita6, Ilya Tolstorukov5, Robert Doebler1, Gerard A Cangelosi2,3 &

Angelika Niemz5

Nucleic acid amplification testing (NAAT) enables rapid and sensitive diagnosis of tuberculosis (TB), which facilitates treatment and mitigates transmission Nucleic acid extraction from sputum constitutes the greatest technical challenge in TB NAAT for near-patient settings This report presents preliminary data for a semi-automated sample processing method, wherein sputum is disinfected and liquefied, followed by PureLyse® mechanical lysis and solid-phase nucleic acid extraction in a

miniaturized, battery-operated bead blender Sputum liquefaction and disinfection enabled a >10 4 fold

reduction in viable load of cultured Mycobacterium tuberculosis (M.tb) spiked into human sputum, which

mitigates biohazard concerns Sample preparation via the PureLyse® method and a clinically validated

manual method enabled positive PCR-based detection for sputum spiked with 10 4 and 10 5 colony

forming units (cfu)/mL M.tb At 103 cfu/mL sputum, four of six and two of six samples amplified using the comparator and PureLyse® method, respectively For clinical specimens from TB cases and controls, the

two methods provided 100% concordant results for samples with ≥1 mL input volume (N = 41) The

method, but is faster, minimally instrumented, and can be integrated into TB molecular diagnostic platforms designed for near-patient low-resource settings.

Tuberculosis (TB) is a major health threat worldwide with an estimated 9 million incident active TB cases and 1.5 million TB-associated deaths in 20131, mainly in resource-limited settings within high-burden coun-tries in Africa, Asia, and Eastern Europe Despite international efforts2, active TB continues to be significantly under-diagnosed, or is diagnosed long after becoming symptomatic and infectious, which compromises the abil-ity to effectively treat patients and curb transmission3–5

In most endemic regions, diagnosis of active pulmonary TB relies on smear microscopy, which is relatively simple and low cost, but suffers from insufficient sensitivity and specificity6,7 Culture-based methods, the current gold standard for TB diagnosis, are highly sensitive but expensive, require biosafety level 3 (BSL3) laboratory infrastructure, and the time to result is usually several weeks As a result, neither microscopy nor culture is suffi-cient for effective case finding, patient management, and containment of TB transmission

Nucleic acid amplification testing (NAAT) is becoming more integral to TB diagnostics in developed and developing countries8 NAAT enables sensitive and specific TB diagnosis4,9,10, can identify drug resistance muta-tions, and in principle can provide results during the same patient visit, which reduces loss to follow-up However, worldwide implementation of TB NAAT is hampered by its relatively high cost and complexity8 TB NAATs in use or in the development pipeline vary in complexity11 and entail either laboratory-developed tests12–14, or com-mercial systems9,15–19 based on the polymerase chain reaction (PCR)9,12,19–21, or isothermal amplification methods,

1Claremont BioSolutions, LLC, Upland, CA 2University of Washington, Department of Environmental and Occupational Health Sciences, Seattle, WA 3Seattle Biomedical Research Institute, Seattle, WA 4University of Santo Tomas Graduate School, Manila, Philippines 5Keck Graduate Institute of Applied Life Sciences, Claremont, CA

6Public Health - Seattle & King County, TB Control Program, Seattle, WA Correspondence and requests for materials should be addressed to A.N (email: aniemz@kgi.edu)

Received: 30 July 2015

Accepted: 16 November 2015

Published: 20 January 2016

OPEN

Trang 2

such as loop-mediated isothermal amplification (LAMP)15,22, transcription-mediated amplification (TMA)18, cross-priming amplification (CPA)16, or helicase-dependent amplification (HDA)17,23

The GeneXpert MTB/RIF is the most widely used TB NAAT system, following WHO endorsement for TB diagnosis and rifampin resistance testing, and global roll-out starting in 201124 This highly automated platform performs nucleic acid sample preparation and hemi-nested PCR amplification with real-time detection25,26, with all reagents on board The GeneXpert is recommended for use in district and sub-district level laboratories of countries where TB and MDR-TB are prevalent However, the instrument and consumables cost remains sub-stantial, and the infrastructure required cannot be accommodated in low-resource microscopy centers and pri-mary care settings that serve the majority of the affected patient population Several other NAAT systems are in late-stage development or on the market for TB diagnosis8,15,16 However, these systems lack integration of sample preparation with amplification and detection in a fully automated format, posing implementation challenges in low-resource, remote primary care settings Methods with cumbersome and lengthy multi-step processes are error-prone, require skilled users, and in most cases additional consumables and laboratory instrumentation (e.g centrifuges and heat baths) which may not be readily available27 Furthermore, low-resource settings often do not have uninterrupted power, which is required to operate such instruments7 The integration of sample preparation therefore is a significant challenge and bottleneck in enabling TB NAAT in near-patient low-resource settings Minimally instrumented, fully enclosed, and battery-operated sample preparation technologies with a small foot-print are ideal for such settings

Many current TB NAAT methods process sputum specimens analogous to culture-based protocols26 First, raw sputum is liquefied, usually using N-acetyl-L-cysteine (NALC) and/or NaOH, to enable manipulation of the viscous matrix Culture-based TB diagnosis requires sample decontamination, which preserves at least some live mycobacteria but inactivates other microorganisms which would otherwise overgrow the slow-growing myco-bacteria However, to protect the operator in low-resource settings with limited biosafety precautions, it is prefer-able for TB NAAT to disinfect the sputum, i.e to render all pathogens including mycobacteria non-viprefer-able Several

reagents have been reported to effectively render Mycobacterium tuberculosis (M.tb) non-viable including sodium

hypochlorite, povidone iodine, and hydrogen peroxide28,29, or in the case of the GeneXpert MTB/RIF assay, iso-propanol with NaOH26 For some TB NAAT methods, the liquefied sputum is centrifuged to pellet bacteria12,13,22, and the pellet is then washed and re-suspended, to remove impurities and in some cases concentrate the bacte-ria in a smaller volume30 This approach resembles culture- and microscopy-based TB diagnostic methods, but centrifugation is difficult to automate In the GeneXpert MTB/RIF assay, bacteria in the processed sputum are separated and concentrated through automated filtration and washing9,25

Mycobacteria have thick waxy cell envelopes that are resistant to many conventional chemical or enzymatic lysis methods Lysis of mycobacteria in most cases entails either heating the sample to ≥ 80 °C for 20 min to

1 h12,31, or mechanical disruption through sonication25,32,33 or high-energy bead beating32,34 If mycobacteria have been isolated from sputum prior to lysis, the lysed material is typically used directly for nucleic acid amplifi-cation Alternatively, if mycobacteria are lysed in the sputum sample, the DNA can be purified by removing inhibitors e.g through adsorption to a zeolite matrix15, through standard solid-phase extraction methods13,14 or sequence-specific capture23,35

Claremont BioSolutions (ClaremontBio) developed a miniaturized, battery-operated bead beating system for mechanical pathogen lysis, called the OmniLyse® device In previous work, this device was shown to effectively

disrupt tough-walled microorganisms, such as M.tb complex bacteria and Bacillus subtilis spores and liberate

their nucleic acids in a format suitable for PCR amplification34 ClaremontBio’s miniaturized bead beating system (Fig. 1) can also perform solid-phase DNA extraction, using the PureLyse® technology36, which does not require chaotropic salts or organic solvents that can inhibit downstream polymerase amplification37,38

This report describes a novel nucleic acid sample preparation method from sputum which can be coupled

with PCR to detect M.tb genomic DNA The method incorporates sample disinfection and liquefaction, followed

by mechanical lysis and solid-phase extraction of liberated nucleic acids using the PureLyse® technology This semi-automated approach is compared to a clinically validated manual sample preparation method of sputum liquefaction, isolation of bacteria via centrifugation, and heat lysis to liberate nucleic acids, developed by the Wadsworth Center at the New York State Department of Health12 The method described herein can be completed

in < 20 min, much faster than the comparator method, uses disposable battery-operated components, protects users by disinfecting samples at the outset, and is suitable for automation In ongoing efforts, we are integrat-ing this method with DNA amplification and detection in a disposable cartridge and portable battery-operated instrument39,40, which has the potential to facilitate near-patient diagnosis of TB in resource-limited settings

Results

We developed a sputum disinfection and liquefaction method, based on trisodium phosphate (TSP) as lique-faction reagent33 and povidone iodine (PVI) as disinfectant28,29 Various formulations of these components were explored, along with necessary incubation times to achieve sample liquefaction and mycobactericidal

proper-ties We conducted a kill study to quantify the effectiveness of the protocol at inactivating M.tb complex cells in sputum, as described in the Methods section Sputum samples spiked with M.tb H37Rv were treated using the

disinfection/liquefaction protocol, and replicates of undiluted and 10-fold diluted samples were plated Treated

spiked sputum samples contained a few M.tb colonies (< 10) on some plates streaked with undiluted sample,

but no colonies were observed for the diluted samples (Table 1) Based on control experiments in buffer without disinfection, each spiked sample contained > 106 cfu/mL M.tb H37Rv in the final suspension, of which > 105 cfu

M.tb H37Rv were plated for the undiluted samples Therefore, we obtained a > 4-log reduction in viability relative

to these controls Furthermore, non-mycobacterial colonies observed in unprocessed sputum controls were not observed in the disinfected samples, suggesting a broad microbicidal effect

Trang 3

In conjunction with this sputum disinfection and liquefaction method, a rapid sputum sample preparation method was employed, using ClaremontBio’s PureLyse® system to lyse M.tb and extract nucleic acids in a

min-iaturized and minimally instrumented format, with a 3-step protocol that takes less than 10 minutes to complete The PureLyse® cartridge (Fig. 1) contains a micro-motor equipped with a precision-cut impeller capable of oper-ating at up to 30,000 rpm with power supplied by a 6 V battery pack The cartridge is packed with beads to gen-erate shear forces sufficient for mechanical lysis of tough-walled organisms, and to bind and release DNA under specific buffer conditions which enables solid-phase nucleic acid extraction34,36

The PureLyse® protocol (liquefaction, disinfection, and nucleic acid extraction) was compared to an estab-lished and clinically validated protocol for nucleic acid extraction from sputum for molecular TB diagnosis,

developed by Halse et al.12 For initial analytical validation, cultured M.tb H37Ra was spiked into M.tb-negative

human sputum at three concentrations and processed using the PureLyse® and comparator sample preparation methods Nucleic acid from samples purified by each method were amplified and detected via the qPCR protocol

of Halse et al (Fig. 2)12 The PureLyse® and comparator sample preparation methods performed comparably for sputum samples spiked with 104 and 105 cfu/mL H37Ra (Fig. 3) At these two concentrations, 100% of the samples (N = 6) ampli-fied by both methods, with comparable Cq values [no statistically significant difference, p = 0.283 (104 cfu/mL) and p = 0.054 (105 cfu/mL), paired sample T-test, 2-tailed] At 103 cfu/mL, four of six samples amplified using the comparator method whereas two of six samples amplified using the PureLyse® method A sample’s extract was considered positive if at least one of two qPCR technical replicates yielded a positive result We observed

no substantial inhibition for either extraction method, as the average internal amplification control Cq’s were comparable for samples processed via the PureLyse® method (30.37 ± 0.31), comparator method (29.99 ± 0.24), and for the DNA standards and no template controls (29.83 ± 0.15), with no statistically significant difference (p = 0.0564 (PureLyse®), p = 0.328 (comparator), One-way ANOVA] None of the negative controls showed false amplification

Figure 1 Disposable miniaturized battery-operated PureLyse® bead blender for mechanical cell lysis and solid-phase nucleic acid extraction Sample in binding buffer, wash, and elution buffer are introduced at the

sample inlet (a) and flow through the PureLyse® chamber (b) containing beads, micro-motor, and impeller, exiting via the outlet (c) Battery pack (Bat-Pac) (d) connected to blender motor via connectors (e, f) Printed

with permission from Claremont BioSolutions

Run

Number of M.tb colonies after sputum disinfection

Sputum dilution Replicate undiluted 10 −1 10 −2 10 −3

1 a

2 b

Table 1 Microbiological verification of sputum disinfection aUntreated control cell concentration

3 × 106 cfu/mL; bUntreated control cell concentration 1.7 × 106 cfu/mL

Trang 4

To test the performance of the PureLyse® protocol on clinical sputum specimens from TB positive and nega-tive patients, a similar experimental approach was used to analyze 46 sputum specimens collected from patients

of the Seattle-King County Tuberculosis Control Clinic Smear and culture results were not available for each of these individual specimens Smear and culture analysis was only performed on three initial samples used for lab-oratory diagnosis, which were collected before the study samples were obtained Some of the study samples from

patients with active TB were therefore expected to be negative for M.tb DNA by the Purelyse® and comparator

Bacterial pelleting via centrifugation

M.tb (H37Ra)

+

1 mL sputum

Concentrations

105, 104, 103, 0 cfu/mL sputum (n=6)

<10

min

PureLyse® Method Comparator Method

15 min

Sputum Liquefaction/

Decontamination

10 min

Sputum Pre-Processing

15 min

Bacterial Lysis and DNA extraction Heat lysis and

disinfection

60 min

Figure 2 Schematic diagram of the experimental design comparing the comparator 12 and PureLyse®

sample preparation methods TB-negative pooled sputum (~1 mL) samples were spiked with 105, 104, 103, or

0 cfu M.tb H37Ra and processed by both methods Extracted nucleic acids were then amplified and detected using qPCR, as described by Halse et al.12

30 35 40 45

1.E+02 1.E+03 1.E+04 1.E+05

H37Ra M.tb (cfu/mL sputum)

Figure 3 qPCR detection of M.tb H37Ra spiked into sputum, extracted via the comparator (black

diamond) and PureLyse® methods (white square): mean and standard deviation from six biological replicates, with two technical replicates each At 105 and 104 cfu/mL, all replicate samples amplified At

103 cfu/mL, four of six samples and two of six samples amplified for the comparator and PureLyse® methods, respectively

Trang 5

methods due to normal fluctuations in bacillary load Of the 30 specimens obtained from TB positive subjects, 24 samples were positive and five samples were negative following sample preparation by the comparator method One sample was excluded from further analysis due to a technical error during processing All 16 specimens from TB-negative subjects gave negative qPCR results using both methods

Of the 24 samples determined to be positive based on the comparator method, 22 yielded positive qPCR results following PureLyse® sample preparation, while two samples yielded negative qPCR results Both of the PureLyse® method “false negatives” had sample input volumes < 1 mL (a deviation from the standard protocol) and also gave weak signals after extraction via the comparator method Overall, this pilot clinical study resulted

in a true positive fraction (sensitivity relative to the comparator method) of 91.7% (95% Confidence Interval (CI): 71.5–98.5%) when considering all samples (Table 2, “All Samples”), or 100% (95% CI: 80–100%) when consid-ering only samples with input volume > 1mL (Table 2, “Samples of ≥ 1 mL volume”) The true negative fraction (specificity) relative to the comparator method was 100% in both cases (95% CI: 80.8–100%) Comparable aver-age internal amplification control Cq values were observed for the PureLyse® method (28.33 ± 0.42), comparator method (28.04 ± 0.78), and for the DNA standards and no template controls (28.25 ± 0.34), which indicates neg-ligible inhibition for either sample extraction method

Discussion

This report presents preliminary analytical and clinical studies, comparing semi-automated PureLyse® sputum sample preparation to an established and clinically validated manual sample preparation method described by

Halse et al.12 In the analytical evaluation, the comparator method performed slightly better for sputum spiked

with M.tb H37Ra at 103 cfu/mL, the lowest concentration tested, while identical performance was observed at

104 and 105 cfu/mL Both methods gave concordant results when performed on patient-derived clinical samples, except when the sputum sample input volume was less than 1 mL, for which some samples did not amplify fol-lowing PureLyse® sample preparation, and amplified late following the comparator sample preparation method Since substantial inhibition was not observed using either method, discrepancies are likely linked to the DNA extraction yield Ongoing optimization to improve the sensitivity of the PureLyse®-based sputum sample prepa-ration method achieved promising results through refinements in disinfection and liquefaction composition, lysis and binding configuration, and buffer composition

The PureLyse® sputum sample preparation method described herein improves the occupational safety of DNA extraction from sputum for molecular diagnosis of TB In addition to a > 104-fold reduction in M.tb

via-bility, other microorganisms in sputum were rendered uncultivable on Middlebrook media after < 10 minutes of treatment In contrast, many sputum sample preparation protocols, including the comparator method, are not microbicidal until further downstream in the process The GeneXpert MTB/RIF assay includes a sample disin-fection step, enabling > 106 fold reduction in viable M.tb bacterial load26 Through further improvements to our current disinfection method, we anticipate that a similar efficacy can be obtained

While there are limitations attributed to small data sets for both the analytical and clinical studies and further validation of the PureLyse® extraction system is required following subsequent optimization efforts, the prelimi-nary data demonstrate the potential utility in TB NAAT diagnostics The PureLyse® sputum sample preparation method is battery powered, minimally instrumented, and does not require additional equipment such as centri-fuges and heat baths In ongoing efforts, the PureLyse® protocol and mechanical design are being incorporated into a cartridge to enable fully integrated sample preparation, isothermal amplification and lateral flow detec-tion, controlled by a portable, inexpensive instrument39,40 Such devices could enable rapid TB diagnosis at the point-of-care in low-resource, high-burden areas globally

Methods

Sample Sources and General Study Design Analytical studies were performed using as matrix pooled

human sputum purchased from BioreclamationIVT (Westbury, NY), confirmed by us to be negative for M.tb com-plex genomic DNA via the qPCR method of Halse et al.12 M.tb H37Ra (ATCC 25177, cultured in Difco Middlebrook

7H9 broth with 0.2% glycerol, 40 mM sodium pyruvate, 10% [v/v] ADC enrichment and 0.05% Tween 80) was spiked into TB-negative sputum to a final concentration of 103, 104, or 105 cfu/mL For each concentration, plus a TB-negative sputum control spiked with media only, six 1 mL aliquots were processed via the PureLyse® and com-parator sample preparation method,12 followed by amplification and detection using qPCR12, as described below

All Samples

Comparator Method b

45 24 21 PureLyse® Method a pos 22 22 0

Samples of ≥ 1 mL volume

41 20 21 PureLyse® Method a pos 20 20 0

Table 2 Clinical laboratory evaluation of PureLyse® sputum sample preparation aPureLyse® sputum sample preparation of clinical sputum samples, bsample preparation of clinical sputum samples using the

comparator method described by Halse et al.12 followed by qPCR analysis

Trang 6

Clinical sputum specimens were collected at the Public Health–Seattle & King County TB Clinic (Seattle, WA) from de-identified male and female subjects 18 years or older able to provide spontaneous sputum specimens Protocols and consent forms were approved by Institutional Review Boards at the University of Washington and Claremont Graduate University Informed consent was obtained from all subjects, and sample collection was car-ried out in accordance with the approved protocol Up to ten specimens were collected per subject, with at least eight hours between each sample For subjects with active TB, samples were collected within seven days of treat-ment initiation Of the 46 specimens included in this study, 30 were obtained from 17 subjects subsequently diag-nosed by microbiological culture and clinical criteria as active pulmonary TB cases; and 16 specimens came from ten patients who microbiologically and clinically did not have active TB Each clinical sputum sample was divided into two aliquots of equal volume, typically ~1 mL, which were then processed respectively via the PureLyse® and comparator sample preparation method12, followed by qPCR amplification and detection12 For five of the 46 sam-ples, aliquots < 1 mL (750–900 μ L) were used due to insufficient total sample volume One low-volume specimen was subsequently excluded from data analysis due to a technical problem during process execution

PureLyse ® Sputum Nucleic Acid Sample Preparation Method Samples were processed using the PureLyse® kit (Claremont BioSolutions LLC), modified for sputum nucleic acid sample preparation to enable sputum liquefaction and disinfection, followed by miniaturized mechanical cell disruption and solid-phase

nucleic acid extraction Sputum liquefaction and disinfection: A disinfection/liquefaction reagent containing PVI

(Rite Aid Corporation) and TSP was prepared within ≤ 2 min before use and vortexed within ≤ 10 sec before adding 0.334 mL to each ~1 mL sputum sample Sample tubes were then vortexed briefly and incubated at room

temperature for 10 minutes Nucleic acid extraction: An equal volume of 2× binding buffer was added to the

disin-fected and liquefied sample, followed by vortexing The sample was then pumped through the PureLyse® blender using a programmable syringe pump (KD Scientific, KDS-250) at a flow rate of 1 mL/min, with the PureLyse®

motor activated, enabling cell lysis and DNA binding to the beads Next, 4 mL wash buffer (0.2× binding buffer) was pumped through the PureLyse® blender at a flow rate of 0.75 mL/min with the motor activated, followed by

1 mL of air purging, with the motor de-activated To elute the nucleic acids from the beads, the PureLyse® cham-ber was filled with ~150 μ L elution buffer, the motor was activated for 30 seconds, and then the syringe pump was used to pump another ~150 μ L elution buffer through the chamber at a flow rate of 0.33 mL/min The final eluate was stored on ice for immediate downstream amplification by qPCR

Verification of Sample Disinfection To evaluate the effectiveness of sputum sample disinfection, M.tb

H37Rv (ATCC 25618, cultured in Difco Middlebrook 7H9 broth with 10% [v/v] ADC enrichment and 0.05% Tween 80) was spiked into pooled TB-negative human sputum to a final concentration of ~107 cfu/mL (estimated

by optical density), and 1 mL spiked sputum aliquots were processed using the sputum liquefaction and disinfec-tion protocol Disinfecdisinfec-tion was stopped after the 10 min incubadisinfec-tion by diluting the sample to 50 mL with sterile phosphate buffered saline (PBS), followed by inversion and vortexing Cells and other particulates were pelleted at

4000 × g for 20 minutes, supernatants were removed, and the pellets re-suspended in 1 mL PBS Ten-fold dilution

series of each cell suspension were prepared in PBS Six replicate 100 μ L aliquots (3 replicates each of 2 separate experiments) of undiluted and diluted samples were plated on Difco Middlebrook 7H10 agar with 10% (v/v) OADC enrichment, incubated at 37 °C for 6–8 weeks, then colonies were counted

In parallel with the spiked sputum experiments, the number of M.tb H37Rv cells remaining after identical

processing but in the absence of disinfection was determined microbiologically These controls were designed to isolate the effect of disinfection from confounding causes of cell loss (e.g adherence to sample tubes and pipette tips, aspiration, etc.) and thereby quantify the effect of disinfection alone Sputum was not used as matrix since

overgrowth with non-mycobacterial organisms present in sputum would confound the results Here, M.tb H37Rv

was spiked into 1 mL PBS aliquots, and processed as described above Six replicate 100 μ L aliquots (3 replicates each of 2 separate experiments) of undiluted and 10× diluted samples were plated and incubated, and colonies were counted Six unprocessed sputum controls (unspiked and untreated) were also plated directly After incuba-tion for 6–8 weeks, these unprocessed sputum samples formed diverse colonies too numerous to count

Comparator Method for Sputum Nucleic Acid Sample Preparation As a comparative nucleic acid

extraction method, sputum samples were processed as described by Halse et al.12 Briefly, an equal volume of 3.5% NaOH was added to each ~1 mL sputum sample Samples were vortexed and incubated for 15 min at room tem-perature to liquefy and decontaminate the sputum Decontamination was stopped by diluting the samples with PBS (pH 6.8) to a final volume of 50 mL, followed by inversion mixing The contents were pelleted by

centrifuga-tion (15 min, 3000 × g), and supernatants were carefully removed by aspiracentrifuga-tion Pellets were resuspended in 1 mL

PBS, heated at 80 °C for 1 hr to lyse the mycobacteria, and stored on ice until qPCR was performed

PCR Amplification and Detection We used a qPCR method for detecting M tuberculosis complex (MTBC) DNA, with internal amplification control, as described by Halse et al.12, with 0.8 mg/mL BSA added to

the master-mix This qPCR method targets the MTBC-specific insertion element IS6110 and a sequence within

an engineered internal control plasmid (pIC) flanked with identical primer binding sites The IS6110 and pIC amplicons can be differentiated with FAM and VIC labeled sequence-specific hydrolysis probes Each sample was

analyzed in two separate reactions: one with only the IS6110-FAM probe, the other with the IS6110-FAM probe,

the pIC-VIC probe, and 1 fg/μ L pIC The degree of PCR inhibition was assessed by comparing Cq values for the internal amplification control (pIC-VIC probe) relative to those in uninhibited reactions receiving water or puri-fied genomic DNA as template PCR amplification and detection was executed at two sites, using either a CFX96 (Bio-Rad) or StepOnePlus (Applied Biosystems)

Trang 7

1 World Health Organization Global tuberculosis report 2014 (World Health Organization, 2014) at http://apps.who.int/iris/ bitstream/10665/137094/1/9789241564809_eng.pdf?ua= 1 Date of Access: 03/09/2015.

2 World Health Organization The Global Plan to Stop TB 2011-2015 (WHO, 2011) at http://www.stoptb.org/assets/documents/ global/plan/TB_GlobalPlanToStopTB2011-2015.pdf Date of Access: 01/24/2014.

3 McNerney, R & Daley, P Towards a point-of-care test for active tuberculosis: obstacles and opportunities Nat Rev Micro 9, 204–213

(2011).

4 Perkins, M D & Cunningham, J Facing the Crisis: Improving the Diagnosis of Tuberculosis in the HIV Era The Journal of Infectious

Diseases 196, S15–S27 (2007).

5 Uys, P W., Warren, R., Helden, P D., van, Murray, M & Victor, T C Potential of Rapid Diagnosis for Controlling Drug-Susceptible

and Drug-Resistant Tuberculosis in Communities Where Mycobacterium tuberculosis Infections Are Highly Prevalent J Clin

Microbiol 47, 1484–1490 (2009).

6 Urdea, M et al Requirements for high impact diagnostics in the developing world Nature 444, 73–79 (2006).

7 Yager, P., Domingo, G J & Gerdes, J Point-of-Care Diagnostics for Global Health Annual Review of Biomedical Engineering 10,

107–144 (2008).

8 Niemz, A & Boyle, D S Nucleic acid testing for tuberculosis at the point-of-care in high-burden countries Expert Review of

Molecular Diagnostics 12, 687–701 (2012).

9 Boehme, C C et al Rapid Molecular Detection of Tuberculosis and Rifampin Resistance New England Journal of Medicine 363,

1005–1015 (2010).

10 Niemz, A., Ferguson, T M & Boyle, D S Point-of-care nucleic acid testing for infectious diseases Trends Biotechnol 29, 240–250

(2011).

11 Pai, M & Schito, M Tuberculosis Diagnostics in 2015: Landscape, Priorities, Needs, and Prospects J Infect Dis 211, S21–S28 (2015).

12 Halse, T A et al Combined Real-Time PCR and rpoB Gene Pyrosequencing for Rapid Identification of Mycobacterium tuberculosis

and Determination of Rifampin Resistance Directly in Clinical Specimens J Clin Microbiol 48, 1182–1188 (2010).

13 Aldous, W K., Pounder, J I., Cloud, J L & Woods, G L Comparison of six methods of extracting Mycobacterium tuberculosis DNA

from processed sputum for testing by quantitative real-time PCR J Clin Microbiol 43, 2471–2473 (2005).

14 Gomez, D I et al Rapid DNA extraction for specific detection and quantitation of Mycobacterium tuberculosis DNA in sputum

specimens using Taqman assays Tuberculosis 91 Suppl 1, S43–48 (2011).

15 Mitarai, S et al Evaluation of a simple loop-mediated isothermal amplification test kit for the diagnosis of tuberculosis The

International Journal of Tuberculosis and Lung Disease 15, 1211–1217 (2011).

16 Fang, R et al Cross-Priming Amplification for Rapid Detection of Mycobacterium tuberculosis in Sputum Specimens J Clin

Microbiol 47, 845–847 (2009).

17 Ao, W et al Rapid Detection of rpoB Gene Mutations Conferring Rifampin Resistance in Mycobacterium tuberculosis J Clin

Microbiol 50, 2433–2440 (2012).

18 Pfyffer, G E., Kissling, P., Wirth, R & Weber, R Direct detection of Mycobacterium tuberculosis complex in respiratory specimens

by a target-amplified test system J Clin Microbiol 32, 918–923 (1994).

19 Hida, Y et al Rapid Detection of the Mycobacterium tuberculosis Complex by Use of Quenching Probe PCR (geneCube) J Clin

Microbiol 50, 3604–3608 (2012).

20 Choi, Y J et al Evaluation of peptide nucleic acid probe-based real-time PCR for detection of Mycobacterium tuberculosis complex

and nontuberculous mycobacteria in respiratory specimens Ann Lab Med 32, 257–263 (2012).

21 Bogard, M et al Multicenter Study of a Commercial, Automated Polymerase Chain Reaction System for the Rapid Detection of

Mycobacterium tuberculosis in Respiratory Specimens in Routine Clinical Practice Eur J Clin Microbiol Infect Dis 20, 724–731

(2001).

22 Boehme, C C et al Operational Feasibility of Using Loop-Mediated Isothermal Amplification for Diagnosis of Pulmonary

Tuberculosis in Microscopy Centers of Developing Countries J Clin Microbiol 45, 1936–1940 (2007).

23 Torres-Chavolla, E & Alocilja, E C Nanoparticle based DNA biosensor for tuberculosis detection using thermophilic

helicase-dependent isothermal amplification Biosens Bioelectron 26, 4614–4618 (2011).

24 Lawn, S D et al Advances in tuberculosis diagnostics: the Xpert MTB/RIF assay and future prospects for a point-of-care test The

Lancet Infectious Diseases 13, 349–361 (2013).

25 Blakemore, R et al Evaluation of the Analytical Performance of the Xpert MTB/RIF Assay J Clin Microbiol 48, 2495–2501 (2010).

26 Helb, D et al Rapid Detection of Mycobacterium tuberculosis and Rifampin Resistance by Use of On-Demand, Near-Patient

Technology J Clin Microbiol 48, 229–237 (2010).

27 Denkinger, C M., Kik, S V & Pai, M Robust, reliable and resilient: designing molecular tuberculosis tests for microscopy centers in

developing countries Expert Rev Mol Diagn 13, 763–767 (2013).

28 Best, M., Sattar, S A., Springthorpe, V S & Kennedy, M E Comparative mycobactericidal efficacy of chemical disinfectants in

suspension and carrier tests Appl Environ Microbiol 54, 2856–2858 (1988).

29 Rikimaru, T et al Efficacy of common antiseptics against multidrug-resistant Mycobacterium tuberculosis Int J Tuberc Lung Dis

6, 763–770 (2002).

30 Warren, J R., Bhattacharya, M., De Almeida, K N., Trakas, K & Peterson, L R A minimum 5.0 ml of sputum improves the

sensitivity of acid-fast smear for Mycobacterium tuberculosis Am J Respir Crit Care Med 161, 1559–1562 (2000).

31 Blackwood, K S et al Viability testing of material derived from Mycobacterium tuberculosis prior to removal from a Containment

Level-III Laboratory as part of a Laboratory Risk Assessment Program BMC Infectious Diseases 5, 4 (2005).

32 Lanigan, M D., Vaughan, J A., Shiell, B J., Beddome, G J & Michalski, W P Mycobacterial proteome extraction: comparison of

disruption methods Proteomics 4, 1094–1100 (2004).

33 Yáñez, M A et al Determination of mycobacterial antigens in sputum by enzyme immunoassay J Clin Microbiol 23, 822–825

(1986).

34 Vandeventer, P E et al Mechanical Disruption of Lysis-Resistant Bacterial Cells by Use of a Miniature, Low-Power, Disposable

Device J Clin Microbiol 49, 2533–2539 (2011).

35 Piersimoni, C., Gherardi, G., Nista, D & Bornigia, S Impact of a Chemistry-Based DNA Extraction Method on Performance of a

Commercial Amplification Assay for Detection of Mycobacterium tuberculosis Complex J Clin Microbiol 47, 282–283 (2009).

36 Doebler, R W et al Continuous-Flow, Rapid Lysis Devices for Biodefense Nucleic Acid Diagnostic Systems Journal of Laboratory

Automation 14, 119–125 (2009).

37 Vandeventer, P E., Mejia, J., Nadim, A., Johal, M S & Niemz, A DNA Adsorption to and Elution from Silica Surfaces: Influence of

Amino Acid Buffers J Phys Chem B 10742–10749 (2013).

38 Vandeventer, P E et al Multiphasic DNA Adsorption to Silica Surfaces under Varying Buffer, pH, and Ionic Strength Conditions J

Phys Chem B 116, 5661–5670 (2012).

39 Roskos, K et al Simple System for Isothermal DNA Amplification Coupled to Lateral Flow Detection PLoS ONE 8, e69355 (2013).

40 Lu, H.-W., Roskos, K., Hickerson, A I., Carey, T & Niemz, A System for portable nucleic acid testing in low resource settings Proc

SPIE 8615, 86150I–86150I–12 (2013).

Trang 8

We thank Kimberlee Musser for advice related to the Halse et al.12 qPCR method, and for supplying the internal control plasmid We further thank Meg Savlov and Sergio Steele at Public Health - Seattle & King County for the collection of clinical sputum samples

Author Contributions

T.M.F., K.M.W., A.L.B., R.D., G.A.C and A.N planned the experiments, T.M.F., K.M.W., A.L.B., D.O and I.T executed the experiments, M.N oversaw the collection of clinical sputum specimens, T.M.F and K.M.W performed the majority of the data analysis, T.M.F., A.N., G.A.C and K.M.W wrote the manuscript, all authors were involved in manuscript review and editing

Additional Information

Competing financial interests: T.M.F is an employee and R.D is president and co-founder of Claremont

BioSolutions, the company commercializing the PureLyse technology Both have equity interests in the company K.M.W., A.L.B., D.O., M.N., I.T., G.A.C and A.N declare no potential conflict of interest

How to cite this article: Ferguson, T M et al Pilot study of a rapid and minimally instrumented sputum sample

preparation method for molecular diagnosis of tuberculosis Sci Rep 6, 19541; doi: 10.1038/srep19541 (2016).

This work is licensed under a Creative Commons Attribution 4.0 International License The images

or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/

Ngày đăng: 04/12/2022, 15:57

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN

🧩 Sản phẩm bạn có thể quan tâm