1. Trang chủ
  2. » Tất cả

S970196 riso comcolor

2 41 0

Đang tải... (xem toàn văn)

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 2
Dung lượng 127,54 KB

Các công cụ chuyển đổi và chỉnh sửa cho tài liệu này

Nội dung

Microsoft Word CXT 019 How to identify the defective position of S97 0176 1 doc ISSUE NO CXT 019 Page of 1 2 Attached Issued By Overseas Technical Sec , Riso Kagaku Corp ComColor Technical Bulletin S9.

Trang 1

ISSUE NO : CXT-019

Page of

1 2

Attached:

Issued By Overseas Technical Sec., Riso Kagaku Corp

ComColor Technical Bulletin

S97-0196 How to identify the blowout of a fuse for HDR PCB

Data Category Field Modification Trouble Shooting General Information Safety Advice

Proceeding Grade Parts Compatibility Handling of Modified Parts

Action ASAP Compatible Free of Charge

Action as given Conditionally Compatible Conditionally Chargeable Action if required Not Compatible Chargeable

Refer in need Old Obsolete

Our Ref

SUBJECT:

[Brief]

If the fuse of Print Head Voltage (39V Line) is blowout, S97-0196 error is displayed

S97-0196-01: Voltage error was detected by head control PCB KC

S97-0196-02: Voltage error was detected by head control PCB MY

Each of Connectors has two fuses Please refer the below list and pictures and check by circuit tester whether the fuse is blowout or not

If the fuse is blowout, you need to replace the HDR PCB

CN J4 J10 J5 J11 J6 J12 J7 J13 J8 J14 J9 J15

FUSE F4,F26 F14,F16 F6,F7 F18,F19 F3,F5 F15,F17 F8,F10 F20,F22 F12,F13 F24,F25 F9,F11 F21,F23

Trang 2

ISSUE NO : CXT-019

Page of

2 2

Attached:

Issued By Overseas Technical Sec., Riso Kagaku Corp

ComColor Technical Bulletin

[How to identify the cause of the blowout fuse]

For Example) The Fuse F26 of Connector J4 is blowout

- Unplug the cable of J4 print head from J4 connector, and attach the cable of J4 to J10 connector

- Keep Power OFF and check the condition of other fuse You should connect the one test pin of tester for GND, and touch another test pin for other fuse, (e.g F4) If the internal of print head is short circuit condition, the tester shows that the meter is approximately zero ohm In this case, you need to replace the print head

-If the print head is still short circuit condition, the replaced HDR PCB will also be broken again

-Therefore, you should check the condition of print head before replacing the HDR PCB