Tài liệu ADC KRONE - Technical Reference - HB25 to KM8 LInk Performance ppt
... 2005 ADC Telecommunications, Inc. All Rights Reserved Web Site: www .adc. com From North America, Call Toll Free: 1-8 0 0-3 6 6-3 891 • Outside of North America: + 1-9 5 2-9 3 8-8 080 Fax: + 1-9 5 2-9 1 7-3 237 ... channel and components guaranteed to meet or exceed TIA/EIA 568-B. 2-1 Category 6 standards. Channel consisted of AirES ® cable, AirES patch cord, Highban...
Ngày tải lên: 20/12/2013, 22:15
... 19.8 16.8 300 36.6 16.8 - - 37.2 35.2 18.2 15.2 350 40.0 16.3 - - 36.2 34.2 16.9 13.9 400 43.2 15.9 - - 35.3 33.3 15.7 12.7 Note: The above listed discrete frequency performance values are ... CM Part #: 6499 1 030-XX Electrical Characteristics cont’d: Freq. Attenuation Return Loss Pr-Pr ACR Power Sum ACR Pr-Pr NEXT Power Sum NEXT Pr-Pr...
Ngày tải lên: 24/01/2014, 03:20
... -0 1 = Grey -0 2 = Blue General Specifications Conductor: 0.5mm Dia. (24 AWG) copper Insulation Polyethylene Jacket PVC Complies to: ISO/IEC11801 TIA/EIA 568-B.2 IEC60332.1 Technical ... Solid UTP 6499 1 028-XX Product Description and Application This Category 5e, UTP 4 Pair cable is an unscreened cable, designed to provide Cat 5 Enhanced Link and Channel p...
Ngày tải lên: 10/12/2013, 02:15
Tài liệu ADC KRONE Network News - Vol.01 No.2 - 2006 pptx
... Laboratory Queensland Medical Laboratory (QML) moves to new premises and installs ADC KRONE s solutions to create a network platform with the capacity to meet future needs of Queensland’s doctors ... you to visit the site and join today. We have also created the TrueNet Integrator program for our installer partners. Members receive ADC KRONE accreditation, allowing them t...
Ngày tải lên: 10/12/2013, 02:15
Tài liệu ADC KRONE Network News - Vol.01 No.3 - 2006 ppt
... the 1-Test Cord Method is faster and easier to set up. The loss due to the method of reference setting in both the 1 and 3-Test Cord Methods is considered to be 2 x Reference to Non -reference ... TIA/EIA 568-B. 2-1 • A-Tick AS/ACIF S008 compliant • UL 1863 certified • Wire can be terminated with either an ADC KRONE or 110 tool • 45 degree silver-plated IDCs provide sec...
Ngày tải lên: 10/12/2013, 02:15
Tài liệu ADC KRONE - Guide - Data Center - TIA 942 Standard Overview pptx
Ngày tải lên: 10/12/2013, 03:15
Tài liệu ADC KRONE - Datasheet - Cat 6 - Cable - 4pr UTP INDOOR pptx
... nominal Complies to: ISO11801 TIA/EIA 568-B.2 IEC33 2-3 Technical Specifications Mechanical Characteristics: Minimum bending radius: - During installation 50mm - After installation ... and electrical performance up to 250MHz. Supplied in a 305m box Note: XX in part number = Jacket colour -0 1 = Grey -0 3 = Blue General Specification and Features...
Ngày tải lên: 11/12/2013, 03:15